Go to page of
Similar user manuals
-
Air Conditioner
Bard PA13482-A
24 pages 0.71 mb -
Air Conditioner
Bard 1 W48A1
25 pages 0.48 mb -
Air Conditioner
Bard HL5S2KA
12 pages 0.45 mb -
Air Conditioner
Bard W42L2
11 pages 0.45 mb -
Air Conditioner
Bard P1224A2
35 pages 0.54 mb -
Air Conditioner
Bard W38A1
12 pages 0.28 mb -
Air Conditioner
Bard W17A1
25 pages 0.34 mb -
Air Conditioner
Bard WL701-C
21 pages 0.71 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Bard w17a2, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Bard w17a2 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Bard w17a2. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Bard w17a2 should contain:
- informations concerning technical data of Bard w17a2
- name of the manufacturer and a year of construction of the Bard w17a2 item
- rules of operation, control and maintenance of the Bard w17a2 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Bard w17a2 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Bard w17a2, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Bard service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Bard w17a2.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Bard w17a2 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
Manual 2100-581B Page 1 of 26 INST ALLA TION INSTRUCTIONS W ALL MOUNTED P ACKAGE AIR CONDITIONERS MODELS W17A2 W17L2 W18A2 W18L2 W24A2 W24L2 W30A2 W30L2 W36A2 W36L2 W42A2 W42L2 W48A2 W48L2 W60A2 W60L2 W70A2 W70L2 Manual : 2100-581B Supersedes: 2100-581A File: V olume III T ab 16 Date: 1 1-25-13 Bard Manufacturing Company , Inc. Bryan, Ohio 43506 Si[...]
-
Page 2
Manual 2100-581B Page 2 of 26 Contents Figures Figure 1 Fresh Air Damper Assembly ..................... 5 Figure 2 Unit Dimensions ....................................... 7 Fi g u r e 3 A Mounting Instructions ............................... 8 Figure 3B Mounting Instructions - W17 – 36 ................ 9 Figure 3C Mounting Instructions - W42, 48,[...]
-
Page 3
Manual 2100-581B Page 3 of 26 GETTING OTHER INFORMA TION AND PUBLICA TIONS These publications can help you install the air conditioner or heat pump. Y ou can usually nd these at your local library or purchase them directly from the publisher . Be sure to consult current edition of each standard. National Electrical Code ....................... A[...]
-
Page 4
Manual 2100-581B Page 4 of 26 W ALL MOUNT GENERAL INFORMA TION AIR CONDITIONER W ALL MOUNT MODEL NOMENCLA TURE W 42 A 2 – A 10 X X X X X A NOTE: Vent options X, B and M are without exhaust capability . May require separate eld supplied barometric relief in building. SHIPPING DAMAGE Upon receipt of equipment, the carton should be checked for ex[...]
-
Page 5
Manual 2100-581B Page 5 of 26 DUCT WORK All duct work, supply and return, must be properly sized for the design airow requirement of the equipment. Air Conditioning Contractors of America (ACCA) is an excellent guide to proper sizing. All duct work or portions thereof not in the conditioned space should be properly insulated in order to both con[...]
-
Page 6
Manual 2100-581B Page 6 of 26 Clearances Required for Service Access and Adequate Condenser Airow MODELS LEFT SIDE RIGHT SIDE DISCHARGE SIDE W17A, W18A, W24A, W30A, W36A 15" 20" 10' W17L, W18L, W24L, W30L, W36L 20" 15" 10' W42A, W48A, W60A, W70A 20" 20" 10' W42L, W48L, W60L, W70L 20" 20" 10&[...]
-
Page 7
Manual 2100-581B Page 7 of 26 Dimensions of Basic Unit for Architectural and Installation Requirements (Nominal) MODEL WIDTH (W) DEPTH (D) HEIGHT (H) SUPPL Y RETURN A B C B E F G I J K L M N O P Q R S T W17A, L W18A, L W24A, L 33.300 17.125 70.563 7.88 19.88 1 1.88 19.88 35.00 1 1.00 25.75 20.56 26.75 28.06 29.25 27.00 2.63 34.13 22.06 10.55 4.19 1[...]
-
Page 8
Manual 2100-581B Page 8 of 26 FIGURE 3A W17A2, W17L2, W18A2, W18L2, W24A2, W24L2 MOUNTING INSTRUCTIONS 12" 12" 12" 12" 12" 20" 20" 1" 3" 4" Typ. 8" 20 1 2 " 12" 1" 3 1 8 " 4" Typ. 5" 7 8 " 3 13 16 " 2" 2" 7 1 16 " 1 16 " 7 CONTRO LS AN[...]
-
Page 9
Manual 2100-581B Page 9 of 26 FIGURE 3B W30A2, W30L2, W36A2, W36L2 MOUNTING INSTRUCTIONS 28" A C D C 12" 12" 12" 12" 12" 5 1 16 " B E 14" 4 11 16 " 4 11 16 " 4" Ty p. 2 7 8 " 7 8 " 7 8 " 4" Ty p. 7 8 " 3 1 8 " W* R UN IT SH OWN, W* L UN IT MIS-3158 EN TI RE L EN GT[...]
-
Page 10
Manual 2100-581B Page 10 of 26 FIGURE 3C W42A2, W42L2, W48A2, W48L2, W60A2, W60L2, W70A2, W70L2 MOUNTING INSTRUCTIONS D 16" 16" 16" 16" 16" 1 7 8 " 6 1 2 " 6 1 2 " 2 1 8 " 7 8 " 1" 3" 4" Typ. 4" Typ. 6 1 2 " 30" E 16" A C C 3 1 8 " B Wall Opening and Hole Loca[...]
-
Page 11
Manual 2100-581B Page 1 1 of 26 FIGURE 4 ELECTRIC HEA T CLEARANCE W30A2, W30L2, W36A2, W36L2, W42A2, W42L2, W48A2, W48L2, W60A2, W60L2, W70A2, W70L2 W ARNING A minimum of 1/4 inch clearance must be maintained between the supply air duct and combustible materials. This is required for the rst 3 feet of ducting. It is important to insure that the [...]
-
Page 12
Manual 2100-581B Page 12 of 26 FIGURE 5 W ALL MOUNTING INSTRUCTIONS FIGURE 6 W ALL MOUNTING INSTRUCTIONS DUCT O PE NI NG RET URN AIR SU PP L Y AIR W OO D FRAM E W A LL I NST A LL A TI ON O PE NI NG WA LL BE FO RE MO UN T ON UN IT O PE NI NG BE FOR E I NSTA LL ATION BO TT OM MO UN TI NG CONCRET E BLO CK WA LL I NS TA LL ATI ON BRAC KE T. MO UN T ON [...]
-
Page 13
Manual 2100-581B Page 13 of 26 FIGURE 7 COMMON W ALL MOUNTING INST ALLA TIONS LOWER ED R AISE D FLOOR RA FT E RS SU PP L Y AIR C EI LING S UR FA CE WA LL S L EEVE RET URN AIR CLO SE T WA LL GRI LLE FL AS HI NG RET URN AIR FL AS HI NG SU PP LY DUC T M AYBE LOCATED I N A N A TT IC OR BE LOW C EI LING RA FT ER S AS S HO WN SU PP LY DUC T M AY BE LOCAT[...]
-
Page 14
Manual 2100-581B Page 14 of 26 WIRING – MAIN POWER Refer to the unit rating plate for wire sizing information and maximum fuse or “HACR” type circuit breaker size. Each outdoor unit is marked with a “Minimum Circuit Ampacity”. This means that the eld wiring used must be sized to carry that amount of current. Depending on the installed [...]
-
Page 15
Manual 2100-581B Page 15 of 26 ST ART UP THESE UNITS REQUIRE R-410A REFRIGERANT AND POL YOL ESTER OIL. GENERAL: 1. Use separate service equipment to avoid cross contamination of oil and refrigerants. 2. Use recovery equipment rated for R-410A refrigerant. 3. Use manifold gauges rated for R-410A (800 psi/250 psi low). 4. R-410A is a binary blend of [...]
-
Page 16
Manual 2100-581B Page 16 of 26 ST ART UP (Continued) IMPORT ANT INST ALLER NOTE For improved start up performance wash the indoor coil with a dish washing detergent. HIGH PRESSURE SWITCH All W**A/W**L wall mounted air conditioner series models are supplied with a remote reset for the high and low pressure switch. If tripped, this pressure switch ma[...]
-
Page 17
Manual 2100-581B Page 17 of 26 SEQUENCE OF OPERA TION COOLING – Circuit R-Y makes at thermostat pulling in compressor contactor , starting the compressor and outdoor motor . (See NOTE under Condenser Fan Operation if equipped with Low Ambient Control.) The G (indoor motor) circuit is automatically completed by the thermostat on any call for cooli[...]
-
Page 18
Manual 2100-581B Page 18 of 26 TROUBLESHOOTING FIGURE 8 F AN BLADE SETTING T ABLE 1 F AN BLADE DIMENSION R-410A REFRIGERANT CHARGE This unit was charged at the factory with the quantity of refrigerant listed on the serial plate. AHRI capacity and efciency ratings were determined by testing with this refrigerant charge quantity . The following pr[...]
-
Page 19
Manual 2100-581B Page 19 of 26 T ABLE 2 COOLING PRESSURE T ABLE Air T emperature Entering Outdoor Coil °F Low side pressure ± 4 PSIG High side pressure ± 10 PSIG T ables are based upon rated CFM (airow) across the evaporator coil. If there is any doubt as to correct operating charge being in the system, the charge should be removed, system ev[...]
-
Page 20
Manual 2100-581B Page 20 of 26 T ABLE 3 j Maximum size of the time delay fuse or HACR type circuit breaker for protection of eld wiring conductors. Based on 75C copper wire. All wiring must conform to the National Electrical Code and all local codes. These “Minimum Circuit Ampacity” values are to be used for sizing the eld power c[...]
-
Page 21
Manual 2100-581B Page 21 of 26 T ABLE 4 j Maximum size of the time delay fuse or HACR type circuit breaker for protection of eld wiring conductors. Based on 75C copper wire. All wiring must conform to the National Electrical Code and all local codes. These “Minimum Circuit Ampacity” values are to be used for sizing the eld power c[...]
-
Page 22
Manual 2100-581B Page 22 of 26 T ABLE 5 RECOMMENDED AIRFLOW T ABLE 6 INDOOR BLOWER PERFORMANCE T ABLE 7 MAXIMUM ESP OF OPERA TION ELECTRIC HEA T ONL Y V alues shown are for units equipped with standard 1-inch throwaway lter or 1-inch washable lter . Derate ESP by .15 for 2-inch pleated lters. Model Nominal Rated CFM * Nominal Rated ESP * R[...]
-
Page 23
Manual 2100-581B Page 23 of 26 T ABLE 8 ELECTRIC HEA T Models 240V -1 208V-1 240V -3 208V -3 460V-3 KW Amps BTUH Amps BTUH Amps BTUH Amps BTUH Amps BTUH 4 16.7 13650 14.4 10240 5 20.8 17065 18.1 12800 6 14.4 20500 12.5 15360 7.2 20500 8 33.3 27300 28.8 20475 9 21.7 30600 18.7 23030 10.8 30700 10 41.6 34130 36.2 25600 12 14.4 40950 15 62.5 51250 54.[...]
-
Page 24
Manual 2100-581A Page 24 of 26 W17/18A2-A W24 A2 -A W24 A2 -B W24 A2 -C W30 A2 -A W30 A2 -B W30 A2 -C W36 A2 -A W36 A2 -B W36 A2 -C W42 A2 -A W42 A2 -B W42 A2 -C W48 A2 -A W48 A2 -B W48 A2 -C W60 A2 -A W60 A2 -B W60 A2 -C W70 A2 -A W70 A2 -B W70 A2 -C T ABLE 9A OPTIONAL ACCESSORIES — RIGHT HAND EHW A02-A05 X X EHW02A-A08 X X EHW A02A-A10 X X EHW [...]
-
Page 25
Manual 2100-581B Page 25 of 26 T ABLE 9B OPTIONAL ACCESSORIES — LEFT HAND W17/18L2-A W24 L2 -A W24 L2 -B W30 L2 -A W30 L2 -B W30 L2 -C W36 L2 -A W36 L2 -B W36 L2 -C W42 L2 -A W42 L2 -B W42 L2 -C W48 L2 -A W48 L2 -B W48 L2 -C W60 L2 -A W60 L2 -B W60 L2 -C W70 L2 -A W70 L2 -B W70 L2 -C EHW A02A-A05L X X EHW02A-A08L X X EHW A02-A10L X X EHW A24-B06L[...]
-
Page 26
Manual 2100-581B Page 26 of 26 T ABLE 10 VENT & CONTROL OPTIONS W17, W18, W24 W30, W36 W42, W48, W60, W70 Part Number Description CMC-14 ODT X X X CMC-15 Start Kit (230V 1-Phase) X X X CMC-23 DDC X X CMC-24 DDC X CMC-28 LAC X X X BF AD-2 Barometric Fresh Air Damper - Standard X BOP-2 Blank Off Plate X MF AD-2 Motorized Fresh Air Damper X CRV -2[...]