Go to page of
Similar user manuals
-
Uninterruptible power supply (
BlueWalker PowerWalker VI 850 SE
98 pages -
Uninterruptible power supply (
BlueWalker PowerWalker VI 850 LCD
7 pages -
Uninterruptible power supply (
BlueWalker VI 2000 PSW
64 pages -
Uninterruptible power supply (
BlueWalker VFI 2000R LCD
98 pages -
Uninterruptible power supply (
BlueWalker PowerWalker VFI 3000RM LCD
140 pages -
Uninterruptible power supply (
BlueWalker PowerWalker VI 2000RT LCD
40 pages -
Uninterruptible power supply (
BlueWalker 10120176
64 pages -
Uninterruptible power supply (
BlueWalker PowerWalker VI 2200
32 pages
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of BlueWalker PowerWalker VI 1000 LCD, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of BlueWalker PowerWalker VI 1000 LCD one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of BlueWalker PowerWalker VI 1000 LCD. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of BlueWalker PowerWalker VI 1000 LCD should contain:
- informations concerning technical data of BlueWalker PowerWalker VI 1000 LCD
- name of the manufacturer and a year of construction of the BlueWalker PowerWalker VI 1000 LCD item
- rules of operation, control and maintenance of the BlueWalker PowerWalker VI 1000 LCD item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of BlueWalker PowerWalker VI 1000 LCD alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of BlueWalker PowerWalker VI 1000 LCD, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the BlueWalker service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of BlueWalker PowerWalker VI 1000 LCD.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the BlueWalker PowerWalker VI 1000 LCD item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
EN Line In ter activ e UPS P owerW alk er VI 650 L CD/UK P owerW alk er VI 850 L CD/UK P owerW alk er VI 1000 LCD/UK P owerW alk er VI 150 0 LCD/UK P owerW alk er VI 2 000 LCD/U K Quick Sta rt Guide[...]
-
Page 2
EN IMPORT ANT SAFETY INS TRUCTIONS SA VE TH ESE INS TRUCTIONS – Thi s manual cont ains important ins tructions f or mo dels Powe rW alk er VI 650/ 850/ 1000/ 1500/ 2000 LCD /UK that should be followed duri ng installation and maint enance of the UPS and bat teries . This product is s pecially designed for PCs and it is not recommend ed f or u[...]
-
Page 3
EN Servicing of bat terie s should be performed or supervised by personnel knowledge able of bat teries and the r equire d pr ecautions. Keep unauthoriz ed pers onnel away from bat teries . When replacing bat terie s, replace with the same type and number of the sealed lea d -acid bat teries . The maximum ambient temperature rating is 4[...]
-
Page 4
EN 1. Introdu ction Pow erWal ker VI series is an intelligent an d compact line int eractive UPS (Uninterruptible Power Supply) which is designed to prote ct your per sonal computer or sensitive electronic equipments from all forms of power inte rfer ence, including complete power failure s. It is equipped with many fe atur es that allow an y att a[...]
-
Page 5
EN 4 . Product O v erview Front P anel: Back Panel: VI 650/ 850 LCD/UK VI 1000 LCD/UK VI 1500/ 2000 LCD/UK Output recep tacles AC input Modem or phone surg e prot ection USB port Output recep tacles AC i nput Cir cuit break er Modem or phone surg e prot ection USB port Output recep tacles AC input Cir[...]
-
Page 6
EN 4 . Insta llation and Init ial Startup Bef ore ins tallation, ple ase inspect the unit. Be sure that nothing is damag ed. I: Placement & St orag e Conditions Inst all the UPS in a prot ected ar ea that i s free of ex ces sive dust and has ad equate air flow . Plea se place the UPS aw ay from other u nits at le ast 20 cm to av oid int erfe re[...]
-
Page 7
EN VI: T urn On/Off the Unit T urn on t he UPS unit by pressing the power swit ch. T urn off the UPS unit by pressing again the power swit ch. 6. Audib le alarm from t he UPS When UPS swit ches from A C mode to Batt ery Mode to back up power s upply: sounding every 10 s econds When bat tery is low: sounding every s econd When UPS is ove[...]
-
Page 8
EN 8 . Specificatio ns Model VI 650 LC D /UK VI 850 LC D /UK CAP ACITY 650 V A / 360 W 850 V A / 480 W INPUT V olt age 220~240 V AC V olt age Range 162~290 V AC Freque ncy Range 50/ 60Hz±1Hz OUTPUT V olt age R egulation +/ - 10% T r ansf er T ime T ypic al 2-6 ms, 10 ms max. Wa ve form Simulat ed Si ne Wa ve Prot ectio n Short cir cuit and ov erlo[...]