Bosch Appliances D6100 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Bosch Appliances D6100, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Bosch Appliances D6100 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Bosch Appliances D6100. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Bosch Appliances D6100 should contain:
- informations concerning technical data of Bosch Appliances D6100
- name of the manufacturer and a year of construction of the Bosch Appliances D6100 item
- rules of operation, control and maintenance of the Bosch Appliances D6100 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Bosch Appliances D6100 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Bosch Appliances D6100, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Bosch Appliances service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Bosch Appliances D6100.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Bosch Appliances D6100 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    EN Computer Interface Manual Receiver/Gateway Conettix D6600/D6100[...]

  • Page 2

    Conettix D6600/D6100 | Computer Interface Manual | Trademarks 2 Bosch Security Systems, Inc. | 1/07 | 4998122703-01 Trademarks Microsoft ® , Windows ® , Windows NT ® are either registered trademarks or trademarks of Microsoft Corporation in the United States and/or other countries.[...]

  • Page 3

    Conettix D6600/D6100 | Computer Interface Manual | Contents . Bosch Security Systems, Inc. | 1/07 | 4998122703-01 3 Contents 1.0 System Connection .......................................... 7 1.1 Conettix D6680 Ethernet Network Adapter Connection .......................................................... 7 1.2 Direct Connection – RS-232 .........[...]

  • Page 4

    Conettix D6600/D6100 | Computer Interface Manual | Contents 4 Bosch Security Systems, Inc. | 1/07 | 4998122703-01 Appendix G: ADT SIA Report Codes ................... 149 Appendix H: D6600 RB2000 Messages .................. 151 Appendix I: D6600 SafeCom Messages ................. 158 Figures Figure 1: D6600 System – Standard/Network Automation ..[...]

  • Page 5

    Conettix D6600/D6100 | Computer Interface Manual | Contents . Bosch Security Systems, Inc. | 1/07 | 4998122703-01 5 Table 34: VONK (Message Type V) Byte Description ................................................. 27 Table 35: X-SIA Text (Message Type S) Byte Description ................................................. 27 Table 36: SafeCom (Messa[...]

  • Page 6

    Conettix D6600/D6100 | Computer Interface Manual | Contents 6 Bosch Security Systems, Inc. | 1/07 | 4998122703-01 Table 85: X-SIA text (Message Type <TAB>) Byte Description ................................................. 50 Table 86: X-SIA Printer/LCD output ...................... 50 Table 87: SafeCom (Message Type p) Byte Description .....[...]

  • Page 7

    Conettix D6600/D6100 | Computer Interface Manual | 1.0 System Connection . Bosch Security Systems, Inc. | 1/07 | 4998122703-01 7 1.0 System Connection 1.1 Conettix D6680 Ethernet Network Adapter Connection Use the Conettix D6680 Ethernet Network Adapter to connect a manufacturer’s automation software package to the D6600 when the software cannot [...]

  • Page 8

    Conettix D6600/D6100 | Computer Interface Manual | 2. 0 Making the Right Connection 8 Bosch Security Systems, Inc. | 1/07 | 4998122703-01 2.0 Making t he Right Connect ion 2.1 COM3 DB9 Connector The COM3 Port uses a standard DB9 female connector. The suggested connection to the computer is shown in Figure 4 to Figure 6 . When connecting data termin[...]

  • Page 9

    Conettix D6600/D6100 | Computer Interface Manual | 3.0 Computer Communication Protocols . Bosch Security Systems, Inc. | 1/07 | 4998122703-01 9 3.0 Comput er Communic at ion Prot ocols 3.1 D6500 Mode Messages In D6500 Mode, the line number/group number sent to the computer is only one digit. Refer to Table 2 . Table 2: D6600 Line Number/Group Numbe[...]

  • Page 10

    Conettix D6600/D6100 | Computer Interface Manual | 3.0 Computer Communication Protocols 10 Bosch Security Systems, Inc. | 1/07 | 4998122703-01 3.1.2 Ademco 4-1 Express (Message Type b) D6500 Byte Description 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 4-1 Express Example h b r r l s s s s s s a a a a s E s s s X t Table 4: Message Type[...]

  • Page 11

    Conettix D6600/D6100 | Computer Interface Manual | 3.0 Computer Communication Protocols . Bosch Security Systems, Inc. | 1/07 | 4998122703-01 11 3.1.4 Ademco Contact-ID (Message Type a) D6500 Byte Description 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 Contact ID Example h a r r l s a a a a 1 8 Q X Y Z G G C C C t Table 6: Message Type[...]

  • Page 12

    Conettix D6600/D6100 | Computer Interface Manual | 3.0 Computer Communication Protocols 12 Bosch Security Systems, Inc. | 1/07 | 4998122703-01 3.1.6 ADT SIA (Message Type S) D6500 Byte Description 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 h S r r l [ # a a a a | d a m m - d d - y 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 [...]

  • Page 13

    Conettix D6600/D6100 | Computer Interface Manual | 3.0 Computer Communication Protocols . Bosch Security Systems, Inc. | 1/07 | 4998122703-01 13 3.1.8 CFSK (Message Type i) D6500 Byte Description 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 CFSK Example h i r r l s s s s a a a a a a T T E E s s t Table 10: CFSK (Message Type i) Byte Des[...]

  • Page 14

    Conettix D6600/D6100 | Computer Interface Manual | 3.0 Computer Communication Protocols 14 Bosch Security Systems, Inc. | 1/07 | 4998122703-01 3.1.10 DNIS/ANI (Message Type N) D6500 Byte Description 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 H N r r l s D d d d d d d d d 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 DNIS/ANI Example d d & a a a a a [...]

  • Page 15

    Conettix D6600/D6100 | Computer Interface Manual | 3.0 Computer Communication Protocols . Bosch Security Systems, Inc. | 1/07 | 4998122703-01 15 3.1.12 FBI Super Fast (Message Type F) D6500 Byte Description 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 FBI Super Fast Example h F r r l s s s s s s a a a a T Z Z E s s t Table 14: FBI Super[...]

  • Page 16

    Conettix D6600/D6100 | Computer Interface Manual | 3.0 Computer Communication Protocols 16 Bosch Security Systems, Inc. | 1/07 | 4998122703-01 Table 16: Link Test (Message Type 1) Byte Description # Title Description 1 Header Character ( h ) Optional. Check with the computer auto mation software for compatibility. 2 Message Type 1 3-4 Receiver Numb[...]

  • Page 17

    Conettix D6600/D6100 | Computer Interface Manual | 3.0 Computer Communication Protocols . Bosch Security Systems, Inc. | 1/07 | 4998122703-01 17 3.1.16 Sescoa Super Speed (Message Type 7) D6500 Byte Description 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 Sescoa Super Speed Example h 7 r r l s s s s s s a a a a s I A A C s t Table 18: S[...]

  • Page 18

    Conettix D6600/D6100 | Computer Interface Manual | 3.0 Computer Communication Protocols 18 Bosch Security Systems, Inc. | 1/07 | 4998122703-01 3.1.17 Scancom 4-16-1, 5-16-1, 6-16-1 - Av ailable Upon Request (Message Type g) D6500 Byte Description 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 h g r r l a a a a a a s C C C C s 18 19 20 21 22 23 24 25 26 [...]

  • Page 19

    Conettix D6600/D6100 | Computer Interface Manual | 3.0 Computer Communication Protocols . Bosch Security Systems, Inc. | 1/07 | 4998122703-01 19 3.1.18 Scancom 4-24-1, 5-24-1, 6-24-1 - Av ailable Upon Request (Message Type h) D6500 Byte Description 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 h h r r l a a a a a a s C C C C s C C C C s [...]

  • Page 20

    Conettix D6600/D6100 | Computer Interface Manual | 3.0 Computer Communication Protocols 20 Bosch Security Systems, Inc. | 1/07 | 4998122703-01 3.1.19 Seriee FSK (Message Type k) D6500 Byte Description 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 Seriee FSK Example h k r r l s s s s s s a a a a a s E s Z Z t Table 21: Seriee FSK (Message[...]

  • Page 21

    Conettix D6600/D6100 | Computer Interface Manual | 3.0 Computer Communication Protocols . Bosch Security Systems, Inc. | 1/07 | 4998122703-01 21 3.1.21 SIA (Message Type S) Defined Messages D6500 Byte Description 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 SIA Example h S r r l [ # a a a a | E M M Z Z Z Z / ***] t Table 23: SIA (Messag[...]

  • Page 22

    Conettix D6600/D6100 | Computer Interface Manual | 3.0 Computer Communication Protocols 22 Bosch Security Systems, Inc. | 1/07 | 4998122703-01 3.1.22 Silent Knight FSK0 (Message Type 1) D6500 Byte Description 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 Silent Knight FSK0 Example h 1 r r l s s s s s s a a a a s E s s s Z t Table 25: Sil[...]

  • Page 23

    Conettix D6600/D6100 | Computer Interface Manual | 3.0 Computer Communication Protocols . Bosch Security Systems, Inc. | 1/07 | 4998122703-01 23 Table 27: Silent Knight Automation Format To Automation Report Code Description 2 5 16=0(EEZZ) 2 5 16=1(ZZ) Note 00: Alarm Panic PAss 00 01 to 08: Alarm 01 to 08 sA0x 01 to 08 x=1 to 8 09: Holdup Hass 09 1[...]

  • Page 24

    Conettix D6600/D6100 | Computer Interface Manual | 3.0 Computer Communication Protocols 24 Bosch Security Systems, Inc. | 1/07 | 4998122703-01 3.1.23 Silent Knight FSK2 (Message Type m) D6500 Byte Description 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 Silent Knight FSK2 Example h m r r l s a a a a a a a a “ E E Z Z “ * * * t Table[...]

  • Page 25

    Conettix D6600/D6100 | Computer Interface Manual | 3.0 Computer Communication Protocols . Bosch Security Systems, Inc. | 1/07 | 4998122703-01 25 3.1.25 Telim (Message Type n) D6500 Byte Description 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 h n R R L s A A A A A A s E T T Z 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 Telim Example Z Z Z Z Z Z Z [...]

  • Page 26

    Conettix D6600/D6100 | Computer Interface Manual | 3.0 Computer Communication Protocols 26 Bosch Security Systems, Inc. | 1/07 | 4998122703-01 3.1.27 Varitech FSK 4-1 (Message Type 1) D6500 Byte Description 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 Varitech FSK 4-1 Example h 1 r r l s s s s s s a a a a s E s s s X t Table 32: Varitec[...]

  • Page 27

    Conettix D6600/D6100 | Computer Interface Manual | 3.0 Computer Communication Protocols . Bosch Security Systems, Inc. | 1/07 | 4998122703-01 27 3.1.29 VONK (Message Type V) D6500 Byte Description 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 VONK Example h V r r l A A 1 2 3 4 5 6 7 8 9 A B C D E F G t Table 34: VONK (Message Type [...]

  • Page 28

    Conettix D6600/D6100 | Computer Interface Manual | 3.0 Computer Communication Protocols 28 Bosch Security Systems, Inc. | 1/07 | 4998122703-01 3.1.31 SafeCom (Message Type p) D6500 Byte Description 1 2 3 4 5 6 7 8 9 10 11 12 13 14 ... N-1 N SafeCom Example h p r r l A A A A E E E E . . . data . . . t Table 36: SafeCom (Message Type p) Byte Descript[...]

  • Page 29

    Conettix D6600/D6100 | Computer Interface Manual | 3.0 Computer Communication Protocols . Bosch Security Systems, Inc. | 1/07 | 4998122703-01 29 3.2.2 Ademco Contact-ID (Message Type a) SIA Mode Description Contact-ID Example <LF><CRC><a><sequence#><receiver#><line#>[#aaaa|18QXYZGGCCC]<CR> Table 39: Ademco [...]

  • Page 30

    Conettix D6600/D6100 | Computer Interface Manual | 3.0 Computer Communication Protocols 30 Bosch Security Systems, Inc. | 1/07 | 4998122703-01 3.2.3 Ademco 4-1 Express (Message Type b) SIA Mode Description 4-1 Express Example <LF><CRC><b><sequence#><receiver#><line#>[#aaaa|X]<CR> Table 41: Ademco 4-1 Expres[...]

  • Page 31

    Conettix D6600/D6100 | Computer Interface Manual | 3.0 Computer Communication Protocols . Bosch Security Systems, Inc. | 1/07 | 4998122703-01 31 3.2.4 Ademco 4-2 Express (Message Type c) SIA Mode Description 4-2 Express Example <LF><CRC><c><sequence#><receiver#><line# >[#aaaa|XY]<CR> Table 43: Ademco 4-2 Ex[...]

  • Page 32

    Conettix D6600/D6100 | Computer Interface Manual | 3.0 Computer Communication Protocols 32 Bosch Security Systems, Inc. | 1/07 | 4998122703-01 3.2.5 Ademco High Speed 4-8-1, SCANCOM 4-8-1 (Message Type f) SCANCOM 5-8-1, 6-8-1 - available upon request SIA Mode Description High Speed Example <LF><CRC><f><sequence#><receiver[...]

  • Page 33

    Conettix D6600/D6100 | Computer Interface Manual | 3.0 Computer Communication Protocols . Bosch Security Systems, Inc. | 1/07 | 4998122703-01 33 3.2.6 ADT SIA (Message Type <TAB>) SIA Mode Description ADT SIA Example <LF><CRC><TAB><sequence#><receiver#><line#>[#aaaa|<E><damm-dd- yytihh:mm:ss>dat[...]

  • Page 34

    Conettix D6600/D6100 | Computer Interface Manual | 3.0 Computer Communication Protocols 34 Bosch Security Systems, Inc. | 1/07 | 4998122703-01 3.2.8 CFSK (Message Type I) SIA Mode Description CFSK Example <LF><CRC><I><sequence#><Receiver#><line#>[#aaaaaa|TTEE]<CR> Table 49: CFSK (Message Type I) Byte Descri[...]

  • Page 35

    Conettix D6600/D6100 | Computer Interface Manual | 3.0 Computer Communication Protocols . Bosch Security Systems, Inc. | 1/07 | 4998122703-01 35 Undefined Messages When a common format message contains unprintable hex characters (unprintable characters are out of ASCII range 0x32-0x7E) or without an account block: SIA Mode Description SIA Example &[...]

  • Page 36

    Conettix D6600/D6100 | Computer Interface Manual | 3.0 Computer Communication Protocols 36 Bosch Security Systems, Inc. | 1/07 | 4998122703-01 3.2.11 DSC 4-3 (Message Type d) SIA Mode Description DSC4-3 Example <LF><CRC><d><sequence#><receiver#><line#>[#aaaa|XYY]<CR> Table 53: DSC 4-3 (Message Type d) Byte [...]

  • Page 37

    Conettix D6600/D6100 | Computer Interface Manual | 3.0 Computer Communication Protocols . Bosch Security Systems, Inc. | 1/07 | 4998122703-01 37 3.2.12 FBI Super Fast (Message Type F) SIA Mode Description FBI Super Fast Example <LF><CRC><F><sequence#><receiver#><line# >[#aaaa|TZZE]<CR> Table 57: FBI Super F[...]

  • Page 38

    Conettix D6600/D6100 | Computer Interface Manual | 3.0 Computer Communication Protocols 38 Bosch Security Systems, Inc. | 1/07 | 4998122703-01 3.2.13 ITI (Message Type I) SIA Mode Description ITI Example <LF><CRC><I><sequence#><receiver#><line#>[#aaaaa|GIZZEWN]<CR> Table 61: ITI (Message Type I) Byte Descri[...]

  • Page 39

    Conettix D6600/D6100 | Computer Interface Manual | 3.0 Computer Communication Protocols . Bosch Security Systems, Inc. | 1/07 | 4998122703-01 39 3.2.15 RB2000 (Message Type R) Description SIA Mode Description RB2000 Example <LF><CRC><R><sequence#><receiver#><line#>[<VD S message>]<CR> Table 63: RB2000[...]

  • Page 40

    Conettix D6600/D6100 | Computer Interface Manual | 3.0 Computer Communication Protocols 40 Bosch Security Systems, Inc. | 1/07 | 4998122703-01 3.2.16 Robofon (Message Type j) SIA Mode Description Robofon Example <LF><CRC><j><sequence#><receiver#><line# >[#aaaaaa|EE]<CR> Table 65: Robofon (Message Type j) By[...]

  • Page 41

    Conettix D6600/D6100 | Computer Interface Manual | 3.0 Computer Communication Protocols . Bosch Security Systems, Inc. | 1/07 | 4998122703-01 41 Figure 19: Message sent to printer mm/ddshh:mmsLxxsSCNsACCTsaaaaaa+++sACC saaaaaasCCCCsCCCCsCCCCsCCCCsC For lines that are grouped, Gxx appears instead of Lxx. Table 67: Scancom 4-16-1, 5-16-1, 6-16-1 - Av[...]

  • Page 42

    Conettix D6600/D6100 | Computer Interface Manual | 3.0 Computer Communication Protocols 42 Bosch Security Systems, Inc. | 1/07 | 4998122703-01 3.2.19 Seriee DTMF (Message Type l) SIA Mode Description Seriee DTMF Example <LF><CRC><l><sequence#><receiver#><line# >[#aaaa|*data]<CR> Table 70: Seriee DTMF (Messa[...]

  • Page 43

    Conettix D6600/D6100 | Computer Interface Manual | 3.0 Computer Communication Protocols . Bosch Security Systems, Inc. | 1/07 | 4998122703-01 43 3.2.21 Sescoa Super Speed (Message Type 7) SIA Mode Description Sescoa Super Speed Example Table 72: Sescoa Super Speed (Message Type 7) Byte Description Title Description LF Standard line feed character. [...]

  • Page 44

    Conettix D6600/D6100 | Computer Interface Manual | 3.0 Computer Communication Protocols 44 Bosch Security Systems, Inc. | 1/07 | 4998122703-01 3.2.22 Silent Knight FSK() (Message Type <TAB>) SIA Mode Description Silent Knight FSK0 Example <LF><CRC><TAB><sequence#><receiver#><line#>[#aaaa|data]<CR> Tab[...]

  • Page 45

    Conettix D6600/D6100 | Computer Interface Manual | 3.0 Computer Communication Protocols . Bosch Security Systems, Inc. | 1/07 | 4998122703-01 45 Optional Silent Knight FSK1 (Message Type m) If Menu Item 2.5.16 in the D6600/D6100 Receiver is equal to1, the following output is used. SIA Mode Description Silent Knight FSK1 Example <LF><CRC>[...]

  • Page 46

    Conettix D6600/D6100 | Computer Interface Manual | 3.0 Computer Communication Protocols 46 Bosch Security Systems, Inc. | 1/07 | 4998122703-01 Table 77: Silent Knight FSK1 Optional Outputs (continued) Report Code Description To Automation Note 90 Opening OP00 90 91 to 99 Opening 01 to 09 OP0x 91 to 99 3.2.24 Silent Knight FSK2 (Message Type m) SIA [...]

  • Page 47

    Conettix D6600/D6100 | Computer Interface Manual | 3.0 Computer Communication Protocols . Bosch Security Systems, Inc. | 1/07 | 4998122703-01 47 3.2.25 Silent Knight FSK80 (Message Type E) SIA Mode Description Silent Knight FSK80 Example <LF><CRC><E><sequence#><receiver#><line# >[#AAAA|NBAXY]<CR> Table 79: [...]

  • Page 48

    Conettix D6600/D6100 | Computer Interface Manual | 3.0 Computer Communication Protocols 48 Bosch Security Systems, Inc. | 1/07 | 4998122703-01 3.2.26 Telim (Message Type n) SIA Mode Description Telim Example <LF><CRC><n><sequence#><receiver#><line#>[#aaaaaa|EETTZZZZZZZZZZZZZZZZZZ] <CR> Table 81: Telim (Mess[...]

  • Page 49

    Conettix D6600/D6100 | Computer Interface Manual | 3.0 Computer Communication Protocols . Bosch Security Systems, Inc. | 1/07 | 4998122703-01 49 3.2.28 Varitech FSK 4-2 (Message Type <TAB>) SIA Mode Description Varitech FSK 4-2 Example <LF><CRC><TAB><sequence#><receiver#><line#>[#aaaa|data]<CR> Table [...]

  • Page 50

    Conettix D6600/D6100 | Computer Interface Manual | 3.0 Computer Communication Protocols 50 Bosch Security Systems, Inc. | 1/07 | 4998122703-01 3.2.30 X-SIA text (Message Type <TAB>) SIA Mode Description X-SIA Example <LF><CRC><TAB><sequence#><receiver#><line#>[#aaaa|EMMZZZZ*'TTTTTTTTTTTTT' NM/***][...]

  • Page 51

    Conettix D6600/D6100 | Computer Interface Manual | 3.0 Computer Communication Protocols . Bosch Security Systems, Inc. | 1/07 | 4998122703-01 51 3.2.31 SafeCom (Message Type p) SIA Mode Description SafeCom Example <LF><CRC><p><sequence#><receiver#><line#>[#aaaa|EEEEdata]<CR> Table 87: SafeCom (Message Type [...]

  • Page 52

    Conettix D6600/D6100 | Computer Interface Manual | 3.0 Computer Communication Protocols 52 Bosch Security Systems, Inc. | 1/07 | 4998122703-01 3.3 Input Command Processing Input devices, such as automation systems, send the commands described in Table 88 to the receiver. If the receiver does not recognize a command, it generates a REJECT COMMAND me[...]

  • Page 53

    Conettix D6600/D6100 | Computer Interface Manual | Appendix A: Contact ID Event Code Classifications . Bosch Security Systems, Inc. | 1/07 | 4998122703-01 53 Appendix A : Cont act I D Event Code Classific at ions Figure 24: Contact ID format 1234 E 123 01 123 1 2 3 4 5 1 - Customer (Subscriber Account Number) 2 - Event Qualifier - E = New Event, R [...]

  • Page 54

    Conettix D6600/D6100 | Computer Interface Manual | Appendix A: Contact ID Event Code Classifications 54 Bosch Security Systems, Inc. | 1/07 | 4998122703-01 Table 90: Event Codes (continued) # Event Type Zone 24 Hour Non-Burglary: 150 24 Hour (Auxiliary Alarm-24 Hr. Non-Burg-# 151 Gas Detected Alarm-Gas Detected-# 152 Refrigeration Alarm-Refrigerati[...]

  • Page 55

    Conettix D6600/D6100 | Computer Interface Manual | Appendix A: Contact ID Event Code Classifications . Bosch Security Systems, Inc. | 1/07 | 4998122703-01 55 Table 90: Event Codes (continued) # Event Type Zone Protection Loop: 370 Protection Loop Trouble-Protection Loop-# 371 Protection Loop Open Trouble-Prot. Loop Open-# 372 Protection Loop Short [...]

  • Page 56

    Conettix D6600/D6100 | Computer Interface Manual | Appendix A: Contact ID Event Code Classifications 56 Bosch Security Systems, Inc. | 1/07 | 4998122703-01 Table 90: Event Codes (continued) # Event Type Zone Open/Close: 464 Auto Arm Time Extended Status-Auto Arm Time Ext.- User # (Restore not applicable) 465 Panic Alarm Reset Status-PA Reset (Resto[...]

  • Page 57

    Conettix D6600/D6100 | Computer Interface Manual | Appendix A: Contact ID Event Code Classifications . Bosch Security Systems, Inc. | 1/07 | 4998122703-01 57 Table 90: Event Codes (continued) # Event Type Zone Test/Misc.: 601 Manual Test Test-Manually Triggered (Restore not applicable) 602 Periodic Test Test-Periodic (Restore not applicable) 603 Pe[...]

  • Page 58

    Conettix D6600/D6100 | Computer Interface Manual | A ppendix B: Internal Messages 58 Bosch Security Systems, Inc. | 1/07 | 4998122703-01 Appendix B : Int ernal Messages Table 91: Internal Messages # Internal Messages D6500 Output 2 SIA Output 2 Printer Output 1. Acknowledge Acknowledge 2. Keypad Operation 1 X 0 [NYZ] OPERATOR KEYPAD OPERATION 3. Se[...]

  • Page 59

    Conettix D6600/D6100 | Computer Interface Manual | A ppendix B: Internal Messages . Bosch Security Systems, Inc. | 1/07 | 4998122703-01 59 Table 91: Internal Messages (continued) # Internal Messages D6500 Output 2 SIA Output 2 Printer Output 39. System Reset X 37 [NYW01] SYSTEM RESET 40. System Default 1 X 38 [NYG] SYSTEM DEFAULT 41. System Tempera[...]

  • Page 60

    Conettix D6600/D6100 | Computer Interface Manual | A ppendix B: Internal Messages 60 Bosch Security Systems, Inc. | 1/07 | 4998122703-01 Table 91: Internal Messages (continued) # Internal Messages D6500 Output 2 SIA Output 2 Printer Output 77. C900 Output Deactivated X 94 [NSC0007] C900 OUTPUT DEACTIVATED 78. C900 Input Shorted X 89 [NSC0008] C900 [...]

  • Page 61

    Conettix D6600/D6100 | Computer Interface Manual | App endix C: Modem IIIa2 Messages . Bosch Security Systems, Inc. | 1/07 | 4998122703-01 61 Appendix C : Modem I I Ia 2 Mess ages For lines that are grouped, Gxx appears instead of Lxx. Table 92: Modem IIIa 2 Messages Event Device/Mode Display Explanation Refer to Section C.1 Zonex and Comex Transla[...]

  • Page 62

    Conettix D6600/D6100 | Computer Interface Manual | App endix C: Modem IIIa2 Messages 62 Bosch Security Systems, Inc. | 1/07 | 4998122703-01 Table 92: Modem IIIa 2 Messages (continued) Event Device/Mode Display Explanation Refer to Section C.1 Zonex and Comex Translation on page 137. 12. AC Fail Since Last Call Printer: D6500 Mode: SIA Mode: +++ ACC[...]

  • Page 63

    Conettix D6600/D6100 | Computer Interface Manual | App endix C: Modem IIIa2 Messages . Bosch Security Systems, Inc. | 1/07 | 4998122703-01 63 Table 92: Modem IIIa 2 Messages (continued) Event Device/Mode Display Explanation Refer to Section C.1 Zonex and Comex Translation on page 137. 26. Alarm (points < 255) Printer: D6500 Mode: SIA Mode: dd/dd[...]

  • Page 64

    Conettix D6600/D6100 | Computer Interface Manual | App endix C: Modem IIIa2 Messages 64 Bosch Security Systems, Inc. | 1/07 | 4998122703-01 Table 92: Modem IIIa 2 Messages (continued) Event Device/Mode Display Explanation Refer to Section C.1 Zonex and Comex Translation on page 137. 36. Alarm Door Forced (points > 254) Printer: D6500 Mode: SIA M[...]

  • Page 65

    Conettix D6600/D6100 | Computer Interface Manual | App endix C: Modem IIIa2 Messages . Bosch Security Systems, Inc. | 1/07 | 4998122703-01 65 Table 92: Modem IIIa 2 Messages (continued) Event Device/Mode Display Explanation Refer to Section C.1 Zonex and Comex Translation on page 137. 48. Analog Restoral (points > 254) Printer: D6500 Mode: SIA M[...]

  • Page 66

    Conettix D6600/D6100 | Computer Interface Manual | App endix C: Modem IIIa2 Messages 66 Bosch Security Systems, Inc. | 1/07 | 4998122703-01 Table 92: Modem IIIa 2 Messages (continued) Event Device/Mode Display Explanation Refer to Section C.1 Zonex and Comex Translation on page 137. 63. Battery Low Since Last Call Printer: D6500 Mode: SIA Mode: +++[...]

  • Page 67

    Conettix D6600/D6100 | Computer Interface Manual | App endix C: Modem IIIa2 Messages . Bosch Security Systems, Inc. | 1/07 | 4998122703-01 67 Table 92: Modem IIIa 2 Messages (continued) Event Device/Mode Display Explanation Refer to Section C.1 Zonex and Comex Translation on page 137. 77. Bypass, Remote (Call back) Printer: D6500 Mode: SIA Mode: dd[...]

  • Page 68

    Conettix D6600/D6100 | Computer Interface Manual | App endix C: Modem IIIa2 Messages 68 Bosch Security Systems, Inc. | 1/07 | 4998122703-01 Table 92: Modem IIIa 2 Messages (continued) Event Device/Mode Display Explanation Refer to Section C.1 Zonex and Comex Translation on page 137. 88. Bypass, Sked Printer: D6500 Mode: SIA Mode: dd/dd tt:tt Lxx AC[...]

  • Page 69

    Conettix D6600/D6100 | Computer Interface Manual | App endix C: Modem IIIa2 Messages . Bosch Security Systems, Inc. | 1/07 | 4998122703-01 69 Table 92: Modem IIIa 2 Messages (continued) Event Device/Mode Display Explanation Refer to Section C.1 Zonex and Comex Translation on page 137. 98. Cancel Alarm by Area Printer: D6500 Mode: SIA Mode: dd/dd tt[...]

  • Page 70

    Conettix D6600/D6100 | Computer Interface Manual | App endix C: Modem IIIa2 Messages 70 Bosch Security Systems, Inc. | 1/07 | 4998122703-01 Table 92: Modem IIIa 2 Messages (continued) Event Device/Mode Display Explanation Refer to Section C.1 Zonex and Comex Translation on page 137. 109. Card Deleted (By Programmer) (users > 254) Printer: D6500 [...]

  • Page 71

    Conettix D6600/D6100 | Computer Interface Manual | App endix C: Modem IIIa2 Messages . Bosch Security Systems, Inc. | 1/07 | 4998122703-01 71 Table 92: Modem IIIa 2 Messages (continued) Event Device/Mode Display Explanation Refer to Section C.1 Zonex and Comex Translation on page 137. 123. Closing by Account (ID not reported) (area not reported) Pr[...]

  • Page 72

    Conettix D6600/D6100 | Computer Interface Manual | App endix C: Modem IIIa2 Messages 72 Bosch Security Systems, Inc. | 1/07 | 4998122703-01 Table 92: Modem IIIa 2 Messages (continued) Event Device/Mode Display Explanation Refer to Section C.1 Zonex and Comex Translation on page 137. 135. Closing Early By Area Printer: D6500 Mode: SIA Mode: dd/dd tt[...]

  • Page 73

    Conettix D6600/D6100 | Computer Interface Manual | App endix C: Modem IIIa2 Messages . Bosch Security Systems, Inc. | 1/07 | 4998122703-01 73 Table 92: Modem IIIa 2 Messages (continued) Event Device/Mode Display Explanation Refer to Section C.1 Zonex and Comex Translation on page 137. 147. Closing Late by Area (ID not reported) Printer: D6500 Mode:[...]

  • Page 74

    Conettix D6600/D6100 | Computer Interface Manual | App endix C: Modem IIIa2 Messages 74 Bosch Security Systems, Inc. | 1/07 | 4998122703-01 Table 92: Modem IIIa 2 Messages (continued) Event Device/Mode Display Explanation Refer to Section C.1 Zonex and Comex Translation on page 137. 160. Communicatio ns Trouble Restoral (Route Group and SDI Device#[...]

  • Page 75

    Conettix D6600/D6100 | Computer Interface Manual | App endix C: Modem IIIa2 Messages . Bosch Security Systems, Inc. | 1/07 | 4998122703-01 75 Table 92: Modem IIIa 2 Messages (continued) Event Device/Mode Display Explanation Refer to Section C.1 Zonex and Comex Translation on page 137. 172. Date Changed Printer: D6500 Mode: SIA Mode: dd/dd tt:tt Lxx[...]

  • Page 76

    Conettix D6600/D6100 | Computer Interface Manual | App endix C: Modem IIIa2 Messages 76 Bosch Security Systems, Inc. | 1/07 | 4998122703-01 Table 92: Modem IIIa 2 Messages (continued) Event Device/Mode Display Explanation Refer to Section C.1 Zonex and Comex Translation on page 137. 185. Door Cycled (By User, User not identified) (points > 254) [...]

  • Page 77

    Conettix D6600/D6100 | Computer Interface Manual | App endix C: Modem IIIa2 Messages . Bosch Security Systems, Inc. | 1/07 | 4998122703-01 77 Table 92: Modem IIIa 2 Messages (continued) Event Device/Mode Display Explanation Refer to Section C.1 Zonex and Comex Translation on page 137. 197. Door Locked Printer: D6500 Mode: SIA Mode: dd/dd tt:tt Lxx [...]

  • Page 78

    Conettix D6600/D6100 | Computer Interface Manual | App endix C: Modem IIIa2 Messages 78 Bosch Security Systems, Inc. | 1/07 | 4998122703-01 Table 92: Modem IIIa 2 Messages (continued) Event Device/Mode Display Explanation Refer to Section C.1 Zonex and Comex Translation on page 137. 209. Door Request (Request to Enter) (points > 254) Printer: D6[...]

  • Page 79

    Conettix D6600/D6100 | Computer Interface Manual | App endix C: Modem IIIa2 Messages . Bosch Security Systems, Inc. | 1/07 | 4998122703-01 79 Table 92: Modem IIIa 2 Messages (continued) Event Device/Mode Display Explanation Refer to Section C.1 Zonex and Comex Translation on page 137. 221. Door Secured (Automatic) (points > 254) Printer: D6500 M[...]

  • Page 80

    Conettix D6600/D6100 | Computer Interface Manual | App endix C: Modem IIIa2 Messages 80 Bosch Security Systems, Inc. | 1/07 | 4998122703-01 Table 92: Modem IIIa 2 Messages (continued) Event Device/Mode Display Explanation Refer to Section C.1 Zonex and Comex Translation on page 137. 233. Door Unlocked (Automatic) Printer: D6500 Mode: SIA Mode: dd/d[...]

  • Page 81

    Conettix D6600/D6100 | Computer Interface Manual | App endix C: Modem IIIa2 Messages . Bosch Security Systems, Inc. | 1/07 | 4998122703-01 81 Table 92: Modem IIIa 2 Messages (continued) Event Device/Mode Display Explanation Refer to Section C.1 Zonex and Comex Translation on page 137. 244. Duress Printer: D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC a[...]

  • Page 82

    Conettix D6600/D6100 | Computer Interface Manual | App endix C: Modem IIIa2 Messages 82 Bosch Security Systems, Inc. | 1/07 | 4998122703-01 Table 92: Modem IIIa 2 Messages (continued) Event Device/Mode Display Explanation Refer to Section C.1 Zonex and Comex Translation on page 137. 254. Early Open By Area (ID not reported) Printer: D6500 Mode: SIA[...]

  • Page 83

    Conettix D6600/D6100 | Computer Interface Manual | App endix C: Modem IIIa2 Messages . Bosch Security Systems, Inc. | 1/07 | 4998122703-01 83 Table 92: Modem IIIa 2 Messages (continued) Event Device/Mode Display Explanation Refer to Section C.1 Zonex and Comex Translation on page 137. 267. Extend Close Time by Area (users < 255) Printer: D6500 M[...]

  • Page 84

    Conettix D6600/D6100 | Computer Interface Manual | App endix C: Modem IIIa2 Messages 84 Bosch Security Systems, Inc. | 1/07 | 4998122703-01 Table 92: Modem IIIa 2 Messages (continued) Event Device/Mode Display Explanation Refer to Section C.1 Zonex and Comex Translation on page 137. 279. Fail to Execute (Door Unlocked- Interlock) (points > 254) [...]

  • Page 85

    Conettix D6600/D6100 | Computer Interface Manual | App endix C: Modem IIIa2 Messages . Bosch Security Systems, Inc. | 1/07 | 4998122703-01 85 Table 92: Modem IIIa 2 Messages (continued) Event Device/Mode Display Explanation Refer to Section C.1 Zonex and Comex Translation on page 137. 290. Fail To Call RAM Printer: D6500 Mode: SIA Mode: dd/dd tt:tt[...]

  • Page 86

    Conettix D6600/D6100 | Computer Interface Manual | App endix C: Modem IIIa2 Messages 86 Bosch Security Systems, Inc. | 1/07 | 4998122703-01 Table 92: Modem IIIa 2 Messages (continued) Event Device/Mode Display Explanation Refer to Section C.1 Zonex and Comex Translation on page 137. 302. Fire Alarm (point > 254) Printer: D6500 Mode: SIA Mode: dd[...]

  • Page 87

    Conettix D6600/D6100 | Computer Interface Manual | App endix C: Modem IIIa2 Messages . Bosch Security Systems, Inc. | 1/07 | 4998122703-01 87 Table 92: Modem IIIa 2 Messages (continued) Event Device/Mode Display Explanation Refer to Section C.1 Zonex and Comex Translation on page 137. 313. Fire Restore after Trouble/Missi ng Printer: D6500 Mode: SI[...]

  • Page 88

    Conettix D6600/D6100 | Computer Interface Manual | App endix C: Modem IIIa2 Messages 88 Bosch Security Systems, Inc. | 1/07 | 4998122703-01 Table 92: Modem IIIa 2 Messages (continued) Event Device/Mode Display Explanation Refer to Section C.1 Zonex and Comex Translation on page 137. 326. Fire Supervision Trouble (points < 255) Printer: D6500 Mod[...]

  • Page 89

    Conettix D6600/D6100 | Computer Interface Manual | App endix C: Modem IIIa2 Messages . Bosch Security Systems, Inc. | 1/07 | 4998122703-01 89 Table 92: Modem IIIa 2 Messages (continued) Event Device/Mode Display Explanation Refer to Section C.1 Zonex and Comex Translation on page 137. 338. Fire Trouble (point < 255) Printer: D6500 Mode: SIA Mode[...]

  • Page 90

    Conettix D6600/D6100 | Computer Interface Manual | App endix C: Modem IIIa2 Messages 90 Bosch Security Systems, Inc. | 1/07 | 4998122703-01 Table 92: Modem IIIa 2 Messages (continued) Event Device/Mode Display Explanation Refer to Section C.1 Zonex and Comex Translation on page 137. 351. Fire Walk End (no users) Printer: D6500 Mode: SIA Mode: dd/dd[...]

  • Page 91

    Conettix D6600/D6100 | Computer Interface Manual | App endix C: Modem IIIa2 Messages . Bosch Security Systems, Inc. | 1/07 | 4998122703-01 91 Table 92: Modem IIIa 2 Messages (continued) Event Device/Mode Display Explanation Refer to Section C.1 Zonex and Comex Translation on page 137. 359. Force Close Early by Account (ID not reported) Printer: D65[...]

  • Page 92

    Conettix D6600/D6100 | Computer Interface Manual | App endix C: Modem IIIa2 Messages 92 Bosch Security Systems, Inc. | 1/07 | 4998122703-01 Table 92: Modem IIIa 2 Messages (continued) Event Device/Mode Display Explanation Refer to Section C.1 Zonex and Comex Translation on page 137. 364. Forced Close Early by Area(ID not reported) Printer: D6500 Mo[...]

  • Page 93

    Conettix D6600/D6100 | Computer Interface Manual | App endix C: Modem IIIa2 Messages . Bosch Security Systems, Inc. | 1/07 | 4998122703-01 93 Table 92: Modem IIIa 2 Messages (continued) Event Device/Mode Display Explanation Refer to Section C.1 Zonex and Comex Translation on page 137. 372. Force Close Late (7112 Only) Printer: D6500 Mode: SIA Mode:[...]

  • Page 94

    Conettix D6600/D6100 | Computer Interface Manual | App endix C: Modem IIIa2 Messages 94 Bosch Security Systems, Inc. | 1/07 | 4998122703-01 Table 92: Modem IIIa 2 Messages (continued) Event Device/Mode Display Explanation Refer to Section C.1 Zonex and Comex Translation on page 137. 381. Force Closing by Account Printer: D6500 Mode: SIA Mode: dd/dd[...]

  • Page 95

    Conettix D6600/D6100 | Computer Interface Manual | App endix C: Modem IIIa2 Messages . Bosch Security Systems, Inc. | 1/07 | 4998122703-01 95 Table 92: Modem IIIa 2 Messages (continued) Event Device/Mode Display Explanation Refer to Section C.1 Zonex and Comex Translation on page 137. 388. Forced Point Printer: D6500 Mode: SIA Mode: dd/dd tt:tt Lxx[...]

  • Page 96

    Conettix D6600/D6100 | Computer Interface Manual | App endix C: Modem IIIa2 Messages 96 Bosch Security Systems, Inc. | 1/07 | 4998122703-01 Table 92: Modem IIIa 2 Messages (continued) Event Device/Mode Display Explanation Refer to Section C.1 Zonex and Comex Translation on page 137. 400. Late Opening By Account Printer: D6500 Mode: SIA Mode: dd/dd [...]

  • Page 97

    Conettix D6600/D6100 | Computer Interface Manual | App endix C: Modem IIIa2 Messages . Bosch Security Systems, Inc. | 1/07 | 4998122703-01 97 Table 92: Modem IIIa 2 Messages (continued) Event Device/Mode Display Explanation Refer to Section C.1 Zonex and Comex Translation on page 137. 412. Low Battery Printer: D6500 Mode: SIA Mode: dd/dd tt:tt LOW [...]

  • Page 98

    Conettix D6600/D6100 | Computer Interface Manual | App endix C: Modem IIIa2 Messages 98 Bosch Security Systems, Inc. | 1/07 | 4998122703-01 Table 92: Modem IIIa 2 Messages (continued) Event Device/Mode Display Explanation Refer to Section C.1 Zonex and Comex Translation on page 137. 425. Missing Alarm with Recent Closing Created due to alarm within[...]

  • Page 99

    Conettix D6600/D6100 | Computer Interface Manual | App endix C: Modem IIIa2 Messages . Bosch Security Systems, Inc. | 1/07 | 4998122703-01 99 Table 92: Modem IIIa 2 Messages (continued) Event Device/Mode Display Explanation Refer to Section C.1 Zonex and Comex Translation on page 137. 437. Missing Trouble (Area Not Reported) Printer: D6500 Mode: SI[...]

  • Page 100

    Conettix D6600/D6100 | Computer Interface Manual | App endix C: Modem IIIa2 Messages 100 Bosch Security Systems, Inc. | 1/07 | 4998122703-01 Table 92: Modem IIIa 2 Messages (continued) Event Device/Mode Display Explanation Refer to Section C.1 Zonex and Comex Translation on page 137. 449. No Entry (points > 254, users < 255) (Interlock Deny) [...]

  • Page 101

    Conettix D6600/D6100 | Computer Interface Manual | App endix C: Modem IIIa2 Messages . Bosch Security Systems, Inc. | 1/07 | 4998122703-01 101 Table 92: Modem IIIa 2 Messages (continued) Event Device/Mode Display Explanation Refer to Section C.1 Zonex and Comex Translation on page 137. 461. No Entry (Wrong Arming State) Printer: D6500 Mode: SIA Mod[...]

  • Page 102

    Conettix D6600/D6100 | Computer Interface Manual | App endix C: Modem IIIa2 Messages 102 Bosch Security Systems, Inc. | 1/07 | 4998122703-01 Table 92: Modem IIIa 2 Messages (continued) Event Device/Mode Display Explanation Refer to Section C.1 Zonex and Comex Translation on page 137. 474. Opening by Area Printer: D6500 Mode: SIA Mode: dd/dd tt:tt L[...]

  • Page 103

    Conettix D6600/D6100 | Computer Interface Manual | App endix C: Modem IIIa2 Messages . Bosch Security Systems, Inc. | 1/07 | 4998122703-01 103 Table 92: Modem IIIa 2 Messages (continued) Event Device/Mode Display Explanation Refer to Section C.1 Zonex and Comex Translation on page 137. 487. Opening Late by Area (users > 254) Printer: D6500 Mode:[...]

  • Page 104

    Conettix D6600/D6100 | Computer Interface Manual | App endix C: Modem IIIa2 Messages 104 Bosch Security Systems, Inc. | 1/07 | 4998122703-01 Table 92: Modem IIIa 2 Messages (continued) Event Device/Mode Display Explanation Refer to Section C.1 Zonex and Comex Translation on page 137. 502. Perimeter Delay by Area Printer: D6500 Mode: SIA Mode: dd/dd[...]

  • Page 105

    Conettix D6600/D6100 | Computer Interface Manual | App endix C: Modem IIIa2 Messages . Bosch Security Systems, Inc. | 1/07 | 4998122703-01 105 Table 92: Modem IIIa 2 Messages (continued) Event Device/Mode Display Explanation Refer to Section C.1 Zonex and Comex Translation on page 137. 514. Phone Line 2 Fail Printer: D6500 Mode: SIA Mode: dd/dd tt:[...]

  • Page 106

    Conettix D6600/D6100 | Computer Interface Manual | App endix C: Modem IIIa2 Messages 106 Bosch Security Systems, Inc. | 1/07 | 4998122703-01 Table 92: Modem IIIa 2 Messages (continued) Event Device/Mode Display Explanation Refer to Section C.1 Zonex and Comex Translation on page 137. 527. Point Bus Restoral Printer: D6500 Mode: SIA Mode: dd/dd tt:t[...]

  • Page 107

    Conettix D6600/D6100 | Computer Interface Manual | App endix C: Modem IIIa2 Messages . Bosch Security Systems, Inc. | 1/07 | 4998122703-01 107 Table 92: Modem IIIa 2 Messages (continued) Event Device/Mode Display Explanation Refer to Section C.1 Zonex and Comex Translation on page 137. 537. Point Bypass (point > 254) (supervisory point) Printer:[...]

  • Page 108

    Conettix D6600/D6100 | Computer Interface Manual | App endix C: Modem IIIa2 Messages 108 Bosch Security Systems, Inc. | 1/07 | 4998122703-01 Table 92: Modem IIIa 2 Messages (continued) Event Device/Mode Display Explanation Refer to Section C.1 Zonex and Comex Translation on page 137. 548. Programmer Bypass Printer: D6500 Mode: SIA Mode: dd/dd tt:tt[...]

  • Page 109

    Conettix D6600/D6100 | Computer Interface Manual | App endix C: Modem IIIa2 Messages . Bosch Security Systems, Inc. | 1/07 | 4998122703-01 109 Table 92: Modem IIIa 2 Messages (continued) Event Device/Mode Display Explanation Refer to Section C.1 Zonex and Comex Translation on page 137. 563. RAM Access Fail (No Call Back) Printer: D6500 Mode: SIA Mo[...]

  • Page 110

    Conettix D6600/D6100 | Computer Interface Manual | App endix C: Modem IIIa2 Messages 110 Bosch Security Systems, Inc. | 1/07 | 4998122703-01 Table 92: Modem IIIa 2 Messages (continued) Event Device/Mode Display Explanation Refer to Section C.1 Zonex and Comex Translation on page 137. 573. Relay Reset (by USER) Printer: D6500 Mode: SIA Mode: dd/dd t[...]

  • Page 111

    Conettix D6600/D6100 | Computer Interface Manual | App endix C: Modem IIIa2 Messages . Bosch Security Systems, Inc. | 1/07 | 4998122703-01 111 Table 92: Modem IIIa 2 Messages (continued) Event Device/Mode Display Explanation Refer to Section C.1 Zonex and Comex Translation on page 137. 585. Relay Set (by USER) Printer: D6500 Mode: SIA Mode: dd/dd t[...]

  • Page 112

    Conettix D6600/D6100 | Computer Interface Manual | App endix C: Modem IIIa2 Messages 112 Bosch Security Systems, Inc. | 1/07 | 4998122703-01 Table 92: Modem IIIa 2 Messages (continued) Event Device/Mode Display Explanation Refer to Section C.1 Zonex and Comex Translation on page 137. 597. Remote Bypass (No Call back) (point > 254) Printer: D6500[...]

  • Page 113

    Conettix D6600/D6100 | Computer Interface Manual | App endix C: Modem IIIa2 Messages . Bosch Security Systems, Inc. | 1/07 | 4998122703-01 113 Table 92: Modem IIIa 2 Messages (continued) Event Device/Mode Display Explanation Refer to Section C.1 Zonex and Comex Translation on page 137. 609. Restoral from Alarm (no area) Printer: D6500 Mode: SIA Mod[...]

  • Page 114

    Conettix D6600/D6100 | Computer Interface Manual | App endix C: Modem IIIa2 Messages 114 Bosch Security Systems, Inc. | 1/07 | 4998122703-01 Table 92: Modem IIIa 2 Messages (continued) Event Device/Mode Display Explanation Refer to Section C.1 Zonex and Comex Translation on page 137. 621. RF Receiver Trouble Printer: D6500 Mode: SIA Mode: dd/dd tt:[...]

  • Page 115

    Conettix D6600/D6100 | Computer Interface Manual | App endix C: Modem IIIa2 Messages . Bosch Security Systems, Inc. | 1/07 | 4998122703-01 115 Table 92: Modem IIIa 2 Messages (continued) Event Device/Mode Display Explanation Refer to Section C.1 Zonex and Comex Translation on page 137. 633. RF Transmitter Tamper Restoral (Area Not Reported) Printer[...]

  • Page 116

    Conettix D6600/D6100 | Computer Interface Manual | App endix C: Modem IIIa2 Messages 116 Bosch Security Systems, Inc. | 1/07 | 4998122703-01 Table 92: Modem IIIa 2 Messages (continued) Event Device/Mode Display Explanation Refer to Section C.1 Zonex and Comex Translation on page 137. 646. SDI Device Tamper (used by post- OMNI panels) Printer: D6500[...]

  • Page 117

    Conettix D6600/D6100 | Computer Interface Manual | App endix C: Modem IIIa2 Messages . Bosch Security Systems, Inc. | 1/07 | 4998122703-01 117 Table 92: Modem IIIa 2 Messages (continued) Event Device/Mode Display Explanation Refer to Section C.1 Zonex and Comex Translation on page 137. 655. SDI Restoral Printer: D6500 Mode: SIA Mode: dd/dd tt:tt Lx[...]

  • Page 118

    Conettix D6600/D6100 | Computer Interface Manual | App endix C: Modem IIIa2 Messages 118 Bosch Security Systems, Inc. | 1/07 | 4998122703-01 Table 92: Modem IIIa 2 Messages (continued) Event Device/Mode Display Explanation Refer to Section C.1 Zonex and Comex Translation on page 137. 664. Sensor Reset (relay < 255, user > 254) (OMNI) Printer:[...]

  • Page 119

    Conettix D6600/D6100 | Computer Interface Manual | App endix C: Modem IIIa2 Messages . Bosch Security Systems, Inc. | 1/07 | 4998122703-01 119 Table 92: Modem IIIa 2 Messages (continued) Event Device/Mode Display Explanation Refer to Section C.1 Zonex and Comex Translation on page 137. 678. Service Start (no area) Printer: D6500 Mode: SIA Mode: dd/[...]

  • Page 120

    Conettix D6600/D6100 | Computer Interface Manual | App endix C: Modem IIIa2 Messages 120 Bosch Security Systems, Inc. | 1/07 | 4998122703-01 Table 92: Modem IIIa 2 Messages (continued) Event Device/Mode Display Explanation Refer to Section C.1 Zonex and Comex Translation on page 137. 691. Status: Alarm Printer: D6500 Mode: SIA Mode: dd/dd tt:tt Lxx[...]

  • Page 121

    Conettix D6600/D6100 | Computer Interface Manual | App endix C: Modem IIIa2 Messages . Bosch Security Systems, Inc. | 1/07 | 4998122703-01 121 Table 92: Modem IIIa 2 Messages (continued) Event Device/Mode Display Explanation Refer to Section C.1 Zonex and Comex Translation on page 137. 705. Status: Fire Alarm (points < 255) Printer: D6500 Mode: [...]

  • Page 122

    Conettix D6600/D6100 | Computer Interface Manual | App endix C: Modem IIIa2 Messages 122 Bosch Security Systems, Inc. | 1/07 | 4998122703-01 Table 92: Modem IIIa 2 Messages (continued) Event Device/Mode Display Explanation Refer to Section C.1 Zonex and Comex Translation on page 137. 718. Status: Fire Supervision (Water Flow) (point < 255) Print[...]

  • Page 123

    Conettix D6600/D6100 | Computer Interface Manual | App endix C: Modem IIIa2 Messages . Bosch Security Systems, Inc. | 1/07 | 4998122703-01 123 Table 92: Modem IIIa 2 Messages (continued) Event Device/Mode Display Explanation Refer to Section C.1 Zonex and Comex Translation on page 137. 731. Status: Missing Fire Supervision (points < 255) Printer[...]

  • Page 124

    Conettix D6600/D6100 | Computer Interface Manual | App endix C: Modem IIIa2 Messages 124 Bosch Security Systems, Inc. | 1/07 | 4998122703-01 Table 92: Modem IIIa 2 Messages (continued) Event Device/Mode Display Explanation Refer to Section C.1 Zonex and Comex Translation on page 137. 744. Status:Perimet er Instant by Area Printer: D6500 Mode: SIA M[...]

  • Page 125

    Conettix D6600/D6100 | Computer Interface Manual | App endix C: Modem IIIa2 Messages . Bosch Security Systems, Inc. | 1/07 | 4998122703-01 125 Table 92: Modem IIIa 2 Messages (continued) Event Device/Mode Display Explanation Refer to Section C.1 Zonex and Comex Translation on page 137. 756. Status Rpt/Opening Printer: D6500 Mode: SIA Mode: dd/dd tt[...]

  • Page 126

    Conettix D6600/D6100 | Computer Interface Manual | App endix C: Modem IIIa2 Messages 126 Bosch Security Systems, Inc. | 1/07 | 4998122703-01 Table 92: Modem IIIa 2 Messages (continued) Event Device/Mode Display Explanation Refer to Section C.1 Zonex and Comex Translation on page 137. 768. Status: Trouble (point > 254) Printer: D6500 Mode: SIA Mo[...]

  • Page 127

    Conettix D6600/D6100 | Computer Interface Manual | App endix C: Modem IIIa2 Messages . Bosch Security Systems, Inc. | 1/07 | 4998122703-01 127 Table 92: Modem IIIa 2 Messages (continued) Event Device/Mode Display Explanation Refer to Section C.1 Zonex and Comex Translation on page 137. Test-Off Normal Expaned Printer: dd/dd tt:tt Lxx ACC aaaa TEST-[...]

  • Page 128

    Conettix D6600/D6100 | Computer Interface Manual | App endix C: Modem IIIa2 Messages 128 Bosch Security Systems, Inc. | 1/07 | 4998122703-01 Table 92: Modem IIIa 2 Messages (continued) Event Device/Mode Display Explanation Refer to Section C.1 Zonex and Comex Translation on page 137. Test-Off Normal Expaned SIA Mode: <header>[#aaaa|NRY] <h[...]

  • Page 129

    Conettix D6600/D6100 | Computer Interface Manual | App endix C: Modem IIIa2 Messages . Bosch Security Systems, Inc. | 1/07 | 4998122703-01 129 Table 92: Modem IIIa 2 Messages (continued) Event Device/Mode Display Explanation Refer to Section C.1 Zonex and Comex Translation on page 137. 787. Transmitter Tamper Alarm Printer: D6500 Mode: SIA Mode: dd[...]

  • Page 130

    Conettix D6600/D6100 | Computer Interface Manual | App endix C: Modem IIIa2 Messages 130 Bosch Security Systems, Inc. | 1/07 | 4998122703-01 Table 92: Modem IIIa 2 Messages (continued) Event Device/Mode Display Explanation Refer to Section C.1 Zonex and Comex Translation on page 137. 801. Trouble (with Ground Fault) (point > 254) Printer: D6500 [...]

  • Page 131

    Conettix D6600/D6100 | Computer Interface Manual | App endix C: Modem IIIa2 Messages . Bosch Security Systems, Inc. | 1/07 | 4998122703-01 131 Table 92: Modem IIIa 2 Messages (continued) Event Device/Mode Display Explanation Refer to Section C.1 Zonex and Comex Translation on page 137. 816. User Alarm 7 Printer: D6500 Mode: SIA Mode: dd/dd tt:tt Lx[...]

  • Page 132

    Conettix D6600/D6100 | Computer Interface Manual | App endix C: Modem IIIa2 Messages 132 Bosch Security Systems, Inc. | 1/07 | 4998122703-01 Table 92: Modem IIIa 2 Messages (continued) Event Device/Mode Display Explanation Refer to Section C.1 Zonex and Comex Translation on page 137. 828. User Code Changed Printer: D6500 Mode: SIA Mode: dd/dd tt:tt[...]

  • Page 133

    Conettix D6600/D6100 | Computer Interface Manual | App endix C: Modem IIIa2 Messages . Bosch Security Systems, Inc. | 1/07 | 4998122703-01 133 Table 92: Modem IIIa 2 Messages (continued) Event Device/Mode Display Explanation Refer to Section C.1 Zonex and Comex Translation on page 137. 839. User Code Tamper (Area and ID Not Reported) Printer: D6500[...]

  • Page 134

    Conettix D6600/D6100 | Computer Interface Manual | App endix C: Modem IIIa2 Messages 134 Bosch Security Systems, Inc. | 1/07 | 4998122703-01 Table 92: Modem IIIa 2 Messages (continued) Event Device/Mode Display Explanation Refer to Section C.1 Zonex and Comex Translation on page 137. 851. Valid Remote Access Printer: D6500 Mode: SIA Mode: dd/dd tt:[...]

  • Page 135

    Conettix D6600/D6100 | Computer Interface Manual | App endix C: Modem IIIa2 Messages . Bosch Security Systems, Inc. | 1/07 | 4998122703-01 135 Table 92: Modem IIIa 2 Messages (continued) Event Device/Mode Display Explanation Refer to Section C.1 Zonex and Comex Translation on page 137. 865. Walk Test Start (Invisible Points) (users > 254) Printe[...]

  • Page 136

    Conettix D6600/D6100 | Computer Interface Manual | App endix C: Modem IIIa2 Messages 136 Bosch Security Systems, Inc. | 1/07 | 4998122703-01 Table 92: Modem IIIa 2 Messages (continued) Event Device/Mode Display Explanation Refer to Section C.1 Zonex and Comex Translation on page 137. 873. +5V Troubled Printer: D6500 Mode: SIA Mode: dd/dd tt:tt +5 T[...]

  • Page 137

    Conettix D6600/D6100 | Computer Interface Manual | App endix C: Modem IIIa2 Messages . Bosch Security Systems, Inc. | 1/07 | 4998122703-01 137 C.1 Zonex and Comex Translation These numbered items correspond to the number in the last column in Table 92 starting on page 61. 1. The D7112/D9112 verifies the user identification and point data formats an[...]

  • Page 138

    Conettix D6600/D6100 | Computer Interface Manual | Appendix D: Network Messages (D6600 Only) 138 Bosch Security Systems, Inc. | 1/07 | 4998122703-01 Appendix D : Net work Messages ( D6 6 0 0 Only ) For networked accounts, Nxx appears instead of Lxx in the line number. Table 96: Network Messages Event Device/Mode Display Explanation 1 Alarm-Panel Su[...]

  • Page 139

    Conettix D6600/D6100 | Computer Interface Manual | Appendix D: Network Messages (D6600 Only) . Bosch Security Systems, Inc. | 1/07 | 4998122703-01 139 Table 96: Network Messages (continued) Event Device/Mode Display Explanation 11 Change Of Status (C900 Reboot) Printer: D6500 Mode: SIA Mode: dd/dd tt:tt Nxx ACC aa aa STATUS CHANGED +++ aaaa C900 RE[...]

  • Page 140

    Conettix D6600/D6100 | Computer Interface Manual | Appendix D: Network Messages (D6600 Only) 140 Bosch Security Systems, Inc. | 1/07 | 4998122703-01 Table 96: Network Messages (continued) Event Device/Mode Display Explanation 22 Communications Fail Restore (Poll Restore) Printer: D6500 Mode: SIA Mode: dd/dd tt:tt Nxx ACC aa aa COMM FAIL RESTR +++ A[...]

  • Page 141

    Conettix D6600/D6100 | Computer Interface Manual | Appendix E: Pulse Output . Bosch Security Systems, Inc. | 1/07 | 4998122703-01 141 Appendix E : Pulse Out put Table 97 to Table 105 (on page 145) vary depending on the account number specified and the digit parameter programmed using the drop-down menus in Menu Item 3.1.7 Event 3/1 or 4/1 (Figure 2[...]

  • Page 142

    Conettix D6600/D6100 | Computer Interface Manual | Appendix E: Pulse Output 142 Bosch Security Systems, Inc. | 1/07 | 4998122703-01 Table 98: Pulse 3/1E Menu 3.1. 3.12 3-1 Extended Format = 1 # Event Account Number Reporting Digit Device/Mode Displays 7. ALARM 123 45 Printer: D6500 Mode: SIA Mode: DD/DD TT:TT L01 ACCT 123 ALARM_ZN 45 [10]1011ssssss[...]

  • Page 143

    Conettix D6600/D6100 | Computer Interface Manual | Appendix E: Pulse Output . Bosch Security Systems, Inc. | 1/07 | 4998122703-01 143 Table 100: Pulse 3/2 # Event Account Number Reporting Digit Device/Mode Displays 19. ALARM 123 45 Printer: D6500 Mode: SIA Mode: DD/DD TT:TT L01 ACCT 123 ALARM_ZN 45 [10]1011sssssss123sAss45[13] [10]446B16[9]00150101[...]

  • Page 144

    Conettix D6600/D6100 | Computer Interface Manual | Appendix E: Pulse Output 144 Bosch Security Systems, Inc. | 1/07 | 4998122703-01 Table 102: Pulse 4/1E Menu 3.1.3.3 4/1 Extended = 1 # Event Account Number Reporting Digit Device/Mode Displays 31. ALARM 1234 45 Printer: D6500 Mode: SIA Mode: DD/DD TT:TT L01 ACCT 12 34 ALARM_ZN 45 [10]1011ssssss1234[...]

  • Page 145

    Conettix D6600/D6100 | Computer Interface Manual | Appendix E: Pulse Output . Bosch Security Systems, Inc. | 1/07 | 4998122703-01 145 Table 104: Pulse 4/2 # Event Account Number Reporting Digit Device/Mode Displays 43. ALARM 1234 45 Printer: D6500 Mode: SIA Mode: DD/DD TT:TT L01 ACCT 12 34 ALARM_ZN 45 [10]1011ssssss1234sAss45[13] [10]220516[9]00330[...]

  • Page 146

    Conettix D6600/D6100 | Computer Interface Manual | Appendix F: Format ID (by Message Type) – D6600 Only 146 Bosch Security Systems, Inc. | 1/07 | 4998122703-01 Appendix F: F ormat I D ( by Message T ype ) – D6 6 0 0 Only If D6600 Menu Item 2.5.17 equals 1, the following outputs apply. D6500 Byte Description 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 1[...]

  • Page 147

    Conettix D6600/D6100 | Computer Interface Manual | Appendix F: Format ID (by Message Type) – D6600 Only . Bosch Security Systems, Inc. | 1/07 | 4998122703-01 147 Table 108: Message Examples # Communication Format Mode Message 1. Acron Super Fast SIA: D6500: [10]146D18 9 00120101[#123 |45678912][13] [10] 9 011sssss12345678912[14] 2. Ademco Contact[...]

  • Page 148

    Conettix D6600/D6100 | Computer Interface Manual | Appendix F: Format ID (by Message Type) – D6600 Only 148 Bosch Security Systems, Inc. | 1/07 | 4998122703-01 Table 108: Message Examples (continued) # Communication Format Mode Message 23. Robofon SIA: D6500: [10]2D3B15 j 00280101[#123ABC|12][13] [10] j 011ssss123ABC12ssss[14] 4-16-1 SIA: D6500: [...]

  • Page 149

    Conettix D6600/D6100 | Computer Interface Manual | Appendix G: ADT SIA Report Codes . Bosch Security Systems, Inc. | 1/07 | 4998122703-01 149 Appendix G : AD T S IA Report Codes Table 109: ADT SIA Report Codes Description ADT SIA System Event System Reset Reset Memory AC Fail AA AC Restore AH AC Fail 4 hour AT AC Fail 4 hour Restore AJ TELCO Line T[...]

  • Page 150

    Conettix D6600/D6100 | Computer Interface Manual | Appendix G: ADT SIA Report Codes 150 Bosch Security Systems, Inc. | 1/07 | 4998122703-01 Table 109: ADT SIA Report Codes (Continued) Description ADT SIA Other Supervised Bell Alarm UA Supervised Bell Trouble UT Supervised Bell Restore UR Remote Power Supply Alarm UA Remote Power Supply Trouble UT R[...]

  • Page 151

    Conettix D6600/D6100 | Computer Interface Manual | App endix H: D6600 RB2000 Messages . Bosch Security Systems, Inc. | 1/07 | 4998122703-01 151 Appendix H : D6 6 0 0 R B20 0 0 Mess ages For lines that are grouped, Gxx appears instead of Lxx. Table 110: D6600 RB2000 Messages # Event Device/ Mode Display SIA <header>[<VDS message>]<CR&[...]

  • Page 152

    Conettix D6600/D6100 | Computer Interface Manual | A ppendix H: D6600 RB2000 Messages 152 Bosch Security Systems, Inc. | 1/07 | 4998122703-01 Table 110: D6600 RB2000 Messages (continued) # Event Device/ Mode Display SIA <header>[<VDS message>]<CR> 14. PRO 100 Transmitter Printer MM/DD HH:MM Lxx RB 2 ACCT xxxxxxxxxxxx +++ 0E 00 00 [...]

  • Page 153

    Conettix D6600/D6100 | Computer Interface Manual | App endix H: D6600 RB2000 Messages . Bosch Security Systems, Inc. | 1/07 | 4998122703-01 153 Table 110: D6600 RB2000 Messages (continued) # Event Device/ Mode Display SIA <header>[<VDS message>]<CR> 30. RF Y - Alarm Printer MM/DD HH:MM Lxx RB 2 ACCT xxxxxxxxxxxx +++ 0E 00 02 XY 49[...]

  • Page 154

    Conettix D6600/D6100 | Computer Interface Manual | A ppendix H: D6600 RB2000 Messages 154 Bosch Security Systems, Inc. | 1/07 | 4998122703-01 Table 110: D6600 RB2000 Messages (continued) # Event Device/ Mode Display SIA <header>[<VDS message>]<CR> 47. RF Y Maintenance Printer MM/DD HH:MM Lxx RB 2 ACCT xxxxxxxxxxxx +++ 0E 00 02 XY [...]

  • Page 155

    Conettix D6600/D6100 | Computer Interface Manual | App endix H: D6600 RB2000 Messages . Bosch Security Systems, Inc. | 1/07 | 4998122703-01 155 Table 110: D6600 RB2000 Messages (continued) # Event Device/ Mode Display SIA <header>[<VDS message>]<CR> 64. Personal Sign Out Printer MM/DD HH:MM Lxx RB 2 ACCT xxxxxxxxxxxx +++ 0E 00 00 [...]

  • Page 156

    Conettix D6600/D6100 | Computer Interface Manual | A ppendix H: D6600 RB2000 Messages 156 Bosch Security Systems, Inc. | 1/07 | 4998122703-01 Table 110: D6600 RB2000 Messages (continued) # Event Device/ Mode Display SIA <header>[<VDS message>]<CR> 81. Test Call Printer MM/DD HH:MM Lxx RB 2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 79 SIA [...]

  • Page 157

    Conettix D6600/D6100 | Computer Interface Manual | App endix H: D6600 RB2000 Messages . Bosch Security Systems, Inc. | 1/07 | 4998122703-01 157 Table 110: D6600 RB2000 Messages (continued) # Event Device/ Mode Display SIA <header>[<VDS message>]<CR> 98. Status: Battery Empty Printer MM/DD HH:MM Lxx RB 2 ACCT xxxxxxxxxxxx +++ A2 00[...]

  • Page 158

    Conettix D6600/D6100 | Computer Interface Manual | App endix I: D6600 SafeCom Messages 158 Bosch Security Systems, Inc. | 1/07 | 4998122703-01 Appendix I : D6 6 0 0 S afeCom Messages In D6500 Mode, the line number sent to the computer is only one digit. Refer to Table 111 . If Virtual Line is 00, it is disabled. The D6600 reports the actual D6600 l[...]

  • Page 159

    Conettix D6600/D6100 | Computer Interface Manual | Append ix I: D6600 SafeCom Messages . Bosch Security Systems, Inc. | 1/07 | 4998122703-01 159 Table 112: D6600 SafeCom Messages - Line Card or Account Signals # Event Device/ Mode Display Notes on Auto Output 6500 SIA 1 hprrl00000100t <header>[#0000|0100] 1. System Startup Printer 2 dd/dd tt:[...]

  • Page 160

    Conettix D6600/D6100 | Computer Interface Manual | App endix I: D6600 SafeCom Messages 160 Bosch Security Systems, Inc. | 1/07 | 4998122703-01 Table 112: D6600 SafeCom Messages - Line Card or Account Signals (continued) # Event Device/ Mode Display Notes on Auto Output 6500 SIA 1 hprrl00000112t <header>[#0000|0112] 15. System RF Channel Clear[...]

  • Page 161

    Conettix D6600/D6100 | Computer Interface Manual | Append ix I: D6600 SafeCom Messages . Bosch Security Systems, Inc. | 1/07 | 4998122703-01 161 Table 112: D6600 SafeCom Messages - Line Card or Account Signals (continued) # Event Device/ Mode Display Notes on Auto Output 6500 SIA 1 hprrl0aaa03200304t <header>[#0aaa|03200304] 27. Silent/Medica[...]

  • Page 162

    Conettix D6600/D6100 | Computer Interface Manual | App endix I: D6600 SafeCom Messages 162 Bosch Security Systems, Inc. | 1/07 | 4998122703-01 Table 112: D6600 SafeCom Messages - Line Card or Account Signals (continued) # Event Device/ Mode Display Notes on Auto Output 6500 SIA 1 hprrl0aaa03200600t <header>[#0aaa|03200600] 41. Operator Armed [...]

  • Page 163

    Conettix D6600/D6100 | Computer Interface Manual | Append ix I: D6600 SafeCom Messages . Bosch Security Systems, Inc. | 1/07 | 4998122703-01 163 Table 113: D6600 SafeCom Messages - Intercepted Control Panel Signals (continued) # Event Device/ Mode Display 6500 SIA 1 hprrlaaaa072018qeeeggccc0t <header>[#aaaa|072 018qeeeggccc0] 52. Ademco Conta[...]

  • Page 164

    Conettix D6600/D6100 | Computer Interface Manual | App endix I: D6600 SafeCom Messages 164 Bosch Security Systems, Inc. | 1/07 | 4998122703-01 Table 114: Explanation of Automation Output Items (within Message Body only) Character Meaning aaa Radio account number (in hex), range: 001 to 9C4. i Input number, range: 1 to 8. z Zone number, range: 1 to [...]

  • Page 165

    Conettix D6600/D6100 | Computer Interface Manual | Append ix I: D6600 SafeCom Messages . Bosch Security Systems, Inc. | 1/07 | 4998122703-01 165 Table 115: Explanation of Printer Output Items Character Meaning dd/dd Month and day (MM/DD). tt:tt Time of message receipt (HH:MM). S SafeCom xx Line card number, range: 01 to 08. n Radio channel number, [...]

  • Page 166

    Conettix D6600/D6100 | Computer Interface Manual | App endix I: D6600 SafeCom Messages 166 Bosch Security Systems, Inc. | 1/07 | 4998122703-01 Modem IIe Format DD/MM HH:MM:SS NNN > (DDDD) AA EE ZZZ Modem IIe messages are reported as AA EE ZZZ where AA is the area code, EE is the event code from Table 116 , and ZZZ is the zone or user code. For e[...]

  • Page 167

    Conettix D6600/D6100 | Computer Interface Manual | Append ix I: D6600 SafeCom Messages . Bosch Security Systems, Inc. | 1/07 | 4998122703-01 167 Table 116: Supported Event Codes Code Meaning Code Meaning AA Force perimeter delay by user ZZZ. 7B RF receiver tamper rest oral by SDI device ZZZ. A9 Status = perimeter instant. 7A Status fire alarm point[...]

  • Page 168

    © 2007 Bosch Security Systems, Inc. 4998122703-01 Bosch Security Systems, Inc. 130 Perinton Parkway Fairport, NY 14450-9199 Customer Service: (800) 289-0096 Technical Support: (888) 886-6189[...]