Go to page of
Similar user manuals
-
Thermometer
Braun IRT 4020 ThermoScan
55 pages -
Thermometer
Braun IRT4520USSM
42 pages 1.71 mb -
Thermometer
Braun ThermoScan Pro3000
63 pages 0.49 mb -
Thermometer
Braun PRT 1000 High speed
1 pages 1.92 mb -
Thermometer
Braun PRT 1000
2 pages -
Thermometer
Braun ThermoScan 6013
16 pages -
Thermometer
Braun ThermoScan PRO 6000
37 pages 5.22 mb -
Thermometer
Braun Thermoscan 6026 - IRT 3020 CO
20 pages 0.69 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Braun IRT4020, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Braun IRT4020 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Braun IRT4020. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Braun IRT4020 should contain:
- informations concerning technical data of Braun IRT4020
- name of the manufacturer and a year of construction of the Braun IRT4020 item
- rules of operation, control and maintenance of the Braun IRT4020 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Braun IRT4020 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Braun IRT4020, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Braun service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Braun IRT4020.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Braun IRT4020 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
IRT 4520 IRT 4020 Type 6022 Type 6023 IRT 4520/4020 EK KUR TZ DESIGN 12.02.03 ThermoScan 1 -800-327 -7 226 T ype: 6022 I / O mem 6022435_IRT_Korea_S1 Seite 1 Dienstag, 8. August 2006 10:14 10[...]
-
Page 2
Braun Infolines 0800 783 70 10 1 800 509 448 GB IRL English 4 13 Internet: www .braun.com Manufactured by: Braun GmbH Frankfurter Str . 145 61476 Kronber g / Germany 6-022-435/00/VIII-06 GB/Korea Printed in Germany 6022435_IRT_Korea_S2 Seite 1 Dienstag, 8. August 2006 10:24 10[...]
-
Page 3
10 6 5 4 2 1 7 8 3 b a IRT 4520 IRT 4020 9 11 1 -800-32 7 - 7 226 T ype: 6022 E x a c T e m p ThermoScan ThermoScan x a c T e m p I / O mem 5 4 2 1 3 1 -800-32 7 - 7 226 T ype: 6022 start 7 8 9 ThermoScan x a c T e m p start 6022435_IRT_Korea_S3 Seite 1 Dienstag, 8. August 2006 10:03 10[...]
-
Page 4
4 The Braun ThermoScan thermometer has been carefully developed for accurate, safe and fast temperature measurements in the ear. The shape of the thermometer prevents it from being inserted too far into the ear canal to hurt the eardrum. However, as with any thermometer, proper technique is critical to obtaining accurate temperatures. Therefore, re[...]
-
Page 5
5 Body temperature Normal body temperature is a range. The following table shows that this normal range also varies by site. Therefore, readings from different sites should not be directly compared. • As well, a person’s normal temperature range tends to decrease with age. The following table shows normal ThermoScan ranges by age. However, the [...]
-
Page 6
6 Product description 1. Lens filter 2. Probe 3. Lens filter detector 4. Lens filter ejector 5. Display 6. «I/O» button (On/memory function – IRT 4520 only) 7. «ExacTemp» light 8. «start» button 9. Battery door 10. Protective cover (IRT 4520) 11. Cap (IRT 4020) How to use your Braun ThermoScan? 1. To achieve accurate readings, make sure a n[...]
-
Page 7
7 If the probe has been fitted securely into the ear canal during the complete measuring process, a long beep will signal the end of the measuring process. You can be assured to have taken an accurate temperature reading. The result is shown on the display (5). If you take the temperature of another person, the «ExacTemp» light (7) will be of hel[...]
-
Page 8
8 In these cases, remove the individual from the situation and wait 20 minutes prior to taking a temperature. • Use the untreated ear if prescription ear drops or other ear medications have been placed in the ear canal. Memory mode The last temperature taken is stored in its memory and will be automatically displayed when it is turned on again. T[...]
-
Page 9
9 Care and cleaning The probe tip is the most delicate part of the thermometer. It has to be clean and intact to ensure accurate readings. If the thermometer is ever accidentally used without a lens filter, clean the probe tip as follows: Very gently wipe the surface with a cotton swab or soft cloth moistened with alcohol. After the alcohol has com[...]
-
Page 10
10 Trouble-shooting Error message Situation Solution No lens filter is attached. Attach new, clean lens filter. The thermometer cannot identify a secure position of the probe. An accurate measurement was not possible. POS = position error IRT 4020: Clear the display by pushing the «start» button once. IRT 4520: Clear the display by pushing the «[...]
-
Page 11
11 Trouble-shooting Error message Situation Solution Battery is low, but thermometer will still operate correctly. Insert new batteries. Battery is too low to take correct temperature readings. Insert new batteries. Do you have any further questions? Call Braun Infoline, please see page 2. Replacing the batteries The thermometer is supplied with tw[...]
-
Page 12
12 Product specifications Displayed temperature range: 34 – 42.2 °C (93.2 – 108 °F) Operating ambient temperature range: 10 – 40 °C (50 – 104 °F) Display resolution: 0.1 °C or °F Accuracy for displayed temperature range: ± 0.2 °C (35.5 – 42 °C / 95.9 – 107.6 °F) ± 0.3 °C (outside this temperature range) Clinical repeatabilit[...]
-
Page 13
13 6022435_IRT_Korea_S4-30 Seite 13 Donnerstag, 24. August 2006 2:30 14[...]
-
Page 14
14 6022435_IRT_Korea_S4-30 Seite 14 Donnerstag, 24. August 2006 2:30 14[...]
-
Page 15
15 start E x a c T e n ThermoScan IRT 4020 T e m p a c IRT 4520 6022435_IRT_Korea_S4-30 Seite 15 Donnerstag, 24. August 2006 2:30 14[...]
-
Page 16
16 E x a c T e n 6022435_IRT_Korea_S4-30 Seite 16 Donnerstag, 24. August 2006 2:30 14[...]
-
Page 17
17 6022435_IRT_Korea_S4-30 Seite 17 Donnerstag, 24. August 2006 2:30 14[...]
-
Page 18
18 6022435_IRT_Korea_S4-30 Seite 18 Donnerstag, 24. August 2006 2:30 14[...]
-
Page 19
19 6022435_IRT_Korea_S4-30 Seite 19 Donnerstag, 24. August 2006 2:30 14[...]
-
Page 20
20 1 2 ThermoScan 6022435_IRT_Korea_S4-30 Seite 20 Donnerstag, 24. August 2006 2:30 14[...]
-
Page 21
21 0297 6022435_IRT_Korea_S4-30 Seite 21 Donnerstag, 24. August 2006 2:30 14[...]
-
Page 22
Body temperature • Normal body temperature is a range. The following table shows that this normal range also varies by site. Therefore, readings from different sites should not be directly compared. • However, the range of normal also varies from person to person and fluctuates throughout the day. It is therefore important to determine your and[...]
-
Page 23
1. To achieve accurate readings, make sure a new, clean lens filter is in place before each measurement. 2. IRT 4020: Push the «start» button. IRT 4520: Push the «I/O» button. Then wait for the ready signal beep and the ready symbol in the display. 3. Fit the probe snuggly into the ear canal, then push the «start» button. 4. If the probe has [...]
-
Page 24
°C 38.5 38 37.5 37 36.5 35.5 35 34.5 Axillary Oral Rectal ThermoScan 1 Chamberlain, J. M. T erndrup, T . E., New Light on Thermometer Readings, Contemporary Pediatrics, March 1994. 2 Chamberlain, J. M., et al., Determination of Normal Ear T emperature with an Infrar ed Emission Detection Thermometer; Annals of Emergency Medicine, January 1995. 602[...]
-
Page 25
➘ 6022435_IRT_Korea_S4-30 Seite 28 Donnerstag, 24. August 2006 2:30 14[...]