Bunn 40119.0000G manual

1
2
3
4
5
6
7
8
9

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Bunn 40119.0000G, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Bunn 40119.0000G one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Bunn 40119.0000G. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Bunn 40119.0000G should contain:
- informations concerning technical data of Bunn 40119.0000G
- name of the manufacturer and a year of construction of the Bunn 40119.0000G item
- rules of operation, control and maintenance of the Bunn 40119.0000G item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Bunn 40119.0000G alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Bunn 40119.0000G, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Bunn service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Bunn 40119.0000G.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Bunn 40119.0000G item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    TIT AN DUAL™ INST ALLA TION & OPERA TING GUIDE BUNN-O-MA TIC CORPORA TION POST OFFICE BO X 3227 SPRINGFIELD , ILLINOIS 62708-3227 PHONE: (217) 529-6601 F AX: (217) 529-6644 40119.0000G 5/12 ©2007 Bunn-O-Matic Corporation T o ensure you have the latest revision of the manual or to obtain the illustrated parts catalog, please visit the Bunn-O-[...]

  • Page 2

    Page 2 INTRODUCTION This equipment will brew coffee into an awaiting server or airpot. The brewer may have an auxillar y hot water faucet. It is only for indoor use on a sturdy and level counter or shelf. Please install in an area where there are no water jet devices. This brewer can be programmed to adjust different functions of the brewing proces[...]

  • Page 3

    Page 3 40119 010412 #00656.0001 As directed in the International Plumbing Code of the International Code Council and the Food Code Manual of the Food and Drug Administration (FDA), this equipment must be installed with adequate backflow prevention to comply with federal, state and local codes. For models installed outside the U.S.A., you must compl[...]

  • Page 4

    Page 4 40119 080108 ELECTRICAL REQUIREMENTS WARNING - If the power cord is ever damaged, it must be replaced by the manufacturer or its service agent with a special cord available from the manufacturer or its service agent in order to avoid a hazard. Refer to Data Plate on the Brewer , and local/national electrical codes to determine circuit requir[...]

  • Page 5

    Page 5 40119 010412 PLUMBING REQUIREMENTS This brewer must be connected to a cold water system with operating pressure between 20 and 90 psi (138 and 620 kPa) with a minimum of 4.0 gpm from a 1⁄2" or larger supply line. A shut-off valve should be installed in the line before the brewer . Install a regulator in the line when pressure is great[...]

  • Page 6

    Page 6 40119 080108 A. MAIN ON/OFF SWITCH This switch, located under the brewer in front of the right rear leg, turns power on and off to all components in the brewer . B. ON/OFF SWITCH (ENABLE BREW) Pressing the "ON/OFF" switch will alternately turn the selected brewing side on and off. Pressing this switch during the brew cycle will int[...]

  • Page 7

    Page 7 INITIAL SET -UP CAUTION – The brewer must be disconnected from the power source throughout the initial setup, except when specified in the instructions. 1. Insert an empty funnel into the funnel rails of one of the brew stations. 2. Place an empty server under the funnel. 3. Connect the brewer to the power source. Make sure the correspond[...]

  • Page 8

    Page 8 COFFEE BREWING 1. Begin each brew cycle with a clean empty brew funnel. 2. Insert a BUNN filter into the funnel. NOTE: The funnels are equipped with 4 wire loops that can be folded over top edge of filter if desired, to prevent filter from folding in during the brew cycle. 3. Pour the fresh coffee into the filter and level the bed of gro[...]

  • Page 9

    Page 9 40119 010412 CLEANING 1. The use of a damp cloth rinsed in any mild, nonabrasive, liquid detergent is recommended for cleaning all surfaces on Bunn-O-Matic equipment. Do NOT clean this equipment with a water jet device. 2. Check and clean each sprayhead. The sprayhead holes must always remain open. NO TE: Any buildup on the sprayhead may res[...]