Go to page of
Similar user manuals
-
Calculator
Calculated Industries 4325
52 pages -
Calculator
Calculated Industries Qualifier Plus IIIx
77 pages -
Calculator
Calculated Industries Time Master II
37 pages -
Calculator
Calculated Industries 4087
70 pages -
Calculator
Calculated Industries 4225
52 pages -
Calculator
Calculated Industries 4054
52 pages -
Calculator
Calculated Industries 4080
39 pages -
Calculator
Calculated Industries 4020
39 pages
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Calculated Industries ConversionCalc Plus, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Calculated Industries ConversionCalc Plus one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Calculated Industries ConversionCalc Plus. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Calculated Industries ConversionCalc Plus should contain:
- informations concerning technical data of Calculated Industries ConversionCalc Plus
- name of the manufacturer and a year of construction of the Calculated Industries ConversionCalc Plus item
- rules of operation, control and maintenance of the Calculated Industries ConversionCalc Plus item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Calculated Industries ConversionCalc Plus alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Calculated Industries ConversionCalc Plus, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Calculated Industries service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Calculated Industries ConversionCalc Plus.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Calculated Industries ConversionCalc Plus item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
Model 8030 F AS T . ACCU RATE. RELIABLE. C O NVERSION C A L C P LUS ™ U L TIMA TE P ROFESSIONAL C ONVERSION C ALCULA TOR PRG8030E-A.indd 1 8/21/2012 11:39:49 AM[...]
-
Page 2
P ocket R efeRence G uide — 3 CONVERSIONCALC PLUS™ The ConversionCalc Plus ™ is an easy-to -use and power ful handheld ca lc ulat or th at pr ovid es m ore t ha n 50 0 conversion combinations using 70 buil t- in St an dar d, Me tr ic an d oth er unit s of me asu re. Wor k in a nd c onver t bet we en li nea r , are a and vo lum e uni ts, plus [...]
-
Page 3
P ocket R efeRence G uide — 3 The C onve rsionCalc Plus ™ is the professional choice for: • Hea lth C ar e Prof es sio nal s • Sc ient is ts • Phar ma ci sts • Nut r iti oni st s • Lab T ec hn ic ians • Spe ci er s • Importers/Expor ters Wit h th e ConversionCalc Plus ™ you c an c onver t: • Flow R ate • Weight • Line [...]
-
Page 4
P ocket R efeRence G uide — 5 T ABLE OF CONTENTS GETTING ST ARTED 6 Key Denitions 6 Bas ic Funct io n Keys 6 Misce llaneous F unct ion Ke ys 7 Co nvers io n Funct io n Keys 9 Preference Settings 14 Calculating Percentages 16 Using Exponential Notation 17 Memory Operation 19 Paperless T ape Function 20 USING THE CONVERSION CALC PL US 21 Using t[...]
-
Page 5
P ocket R efeRence G uide — 5 V olume Conv ersion 25 Weigh t Conve rsion 28 Weigh t / V olume Con version 29 T emperature Conversion 31 Flow R ate C onver si on 31 Pressure Conv er sion 32 V elocit y Conv ersion 33 T orq ue Conversion 33 Ener gy C onver si on 34 Power C onver si on 34 APPENDIX 35 Default Settings 35 Auto Shut-Off 36 Accuracy/Erro[...]
-
Page 6
P ocket R efeRence G uide — 7 GETTING ST ARTED Y ou may want to p rac ti c e get t ing a fee l for yo ur c alc ul ator keys by rea ding t hr oug h the key de ni tio ns and l ear ni ng how t o ente r dat a, how to st ore va lue s, etc ., befo re pro c eed ing t o the exa mpl es. KEY DEFINITIONS Basic Function Keys O On /C le ar Key — T ur ns [...]
-
Page 7
P ocket R efeRence G uide — 7 (cont’d) / Fr act io n Ba r — Used t o enter f rac ti on s. Fract io ns ca n be ente red as pr op er ( 1/2, 1/8, 1/ 16) o r impr op er (3/2 , 9/8). If the de no mina tor (b ot tom) is not entered , the calculator ’ s fr act io nal a cc ur acy s et tin g is automatically used. S a nd T Used with the dimensional [...]
-
Page 8
P ocket R efeRence G uide — 9 (cont’d) SB Squ ar e Ro ot ( ! ) — Cal cul ate s the Squ are Ro ot of th e numb er in t he di sp lay . S= Pap e rl es s Tape ( T ap e) — Ac ce ss es th e Paper l es s T ape M ode, w hic h kee ps tra ck of yo ur pa st 20 e ntr i es. Usef ul fo r ch ec ki ng st r ing s of numbers. T/ Preference Settings (Prefs ) [...]
-
Page 9
P ocket R efeRence G uide — 9 (cont’d) S. T ota l Co st (C os t) — Cal cul ate s tota l c ost b ase d on ent r y o f per u nit c os t. S% x 2 — Squ are s the va lue o n t h e d i s p l a y. S/ Exp onential Notati on x(1 0 y ) — Enter s expo ne nti al not ati on va lue s. A lso u sed t o tog gle b et we en exp one nti al and n on - exp on [...]
-
Page 10
P ocket R efeRence G uide — 11 Centimeter c Millimete r M Kilometer k Miles N Acre S5 Hectare S4 Boa rd Fe et (B d - Ft) S0 Acr e Fee t (Ac r e - Ft) S6 Gallon G Flui d O unc e F Quar t Tm Pint Tc Cup TM T ablespoo n (t bs p) Tk T easpoon (ts p) TN Dram ( dr) Ti Minim (min ) Tf Liters l Milliliter L Decilit er (d l ) TG Centilit er (c l ) TF Micr[...]
-
Page 11
P ocket R efeRence G uide — 11 (cont’d) Weight Keys UNIT KEY To n s t Pou nd s p Dr y Ou nc e d Kilogram K Grams g Milligram (mg ) Td Microgram (mc g) TK Nanogram (ng) Tg Me t ri c T on s (met tons) S1 Grains Tt Scruples (s c) Tp V elocity Keys UNIT KEY Fee t pe r Minute (ft /min) Sy In ch es p e r Second (i n /se c) Si Fee t pe r Second (f t /[...]
-
Page 12
P ocket R efeRence G uide — 13 Me te r s p er Second (m/s e c) Sc Millimete rs per Second (mm /s ec) SM Kilometers pe r Ho ur (k m / h) Sk Flow Rate Keys UNIT KEY Ga ll on s pe r Minute (g pm ) SG Ou nc es p e r Second (oz /s ec) SF Lit e rs p e r Second (l it er s /s e c) Sl Milliliter s per Second (mL /s ec) SL Pressure Keys UNIT KEY Poun ds p [...]
-
Page 13
P ocket R efeRence G uide — 13 T orque Keys UNIT KEY Inch- Pounds (i n - l bs) S7 Foot - Pounds (f t - l bs) S8 Newton - Meter s (N - m) S9 T emperature Keys UNIT KEY Celsius (°C) S2 Fahre nheit (°F) S3 Kel vi n (K) T1 Rankine (°R) T2 Réaumur (°r ) T3 Energy Keys UNIT KEY Joules (J ) T4 Britis h The r ma l Un it s (BT U) T5 Kilocalories (kca[...]
-
Page 14
P ocket R efeRence G uide — 15 PREFERENCE SETTINGS Pres s T , the n / to acc e ss t he Preferences menu . Continue pressing / to toggle through different Preferences. Press + o r - ke ys to tog gl e bet we en op tio ns of t he different Preferences. Press O to exit Pref ere nc es. Y our c alc ul ator w ill keep your Pre fer enc e Set t ing s unti[...]
-
Page 15
P ocket R efeRence G uide — 15 Thi rd pr es s of / : (Volume An swer Format) VOL S td . + VOL 0. CU Y D + VOL 0. CU FE ET + VOL 0. CU M + (repeats options ) VOL St d. Four t h pr es s of / : (Exponential Mo de) E XP O n + E XP O FF + (repeats options ) E XP O n Fif t h pre ss o f / : (Metri c Rounding) ME TR 0.0 0 0 M + ME TR FLOAt M + (repeats o[...]
-
Page 16
P ocket R efeRence G uide — 17 CALCULA TING PERCENT AGES The % key c an be u sed f or ndin g a given p er ce nt of a num be r or fo r wor ki ng ad d - on, d isc o unt or d ivi si on per ce nt age c al cu lat io ns. It c a n be use d wit h any t yp e of num be r , in any dime nsi on (fe et, in ch, m ill imet er , etc . ) and any t y pe of c o [...]
-
Page 17
P ocket R efeRence G uide — 17 USING EXPONENTIAL NOT A TION Y o ur c alc ula tor i s defa ulte d to have expo nent ia l not ati on s et to “on.” Ther efo re, any inte ge r valu e excee din g seven di git s wi ll dis pl ay in exp one nti al fo rm at. W he n expo nent ia l not ati on i s of f, th e calculator adjusts dimensio ned value s to a h[...]
-
Page 18
P ocket R efeRence G uide — 19 (cont’d) Enter 2 ,3 5 6 and c hang e to exponential notation: KEYST ROKE D I S P L AY 2356= 2356. / 2.35600 03 Enter 0 .0 0 0 5 6 and c han ge to exponential notation: .00056= 0. 00056 / 5.60000 - 04 MEMOR Y OPERA TION Whenever the P key is pr es se d, the d isp layed val ue wi ll b e add ed to the M e mor y . O t[...]
-
Page 19
P ocket R efeRence G uide — 19 (cont’d) Whe n M emo r y i s rec al le d ( rP ), co nse cu ti ve pre ss es of P w ill disp lay th e c alc ula ted Avera ge an d tot al C o unt o f th e ac c umu lat ed va lu es . Using M+ KEYST ROKE D I S P L AY 45P M+ 4 5. & 25P M+ 25 . & 15SP M- 15. & rP T TL 55. & P A VG 1 8.33333 & P CNT 3.[...]
-
Page 20
P ocket R efeRence G uide — 21 Y ou can replace a value in one of these Memory registers by storing a new value in place of the stored value. — Sto re sin gl e value i n M 0 — Cle ar M 0 — Rec all M 0 Sto re 212.5 into M 0 , r eca ll th e valu e and then clear the v alue. KEYST ROKE D I S P L AY 212.5 Sr0 M- 0 212 . 5 oO 0. r 0 M- 0 212 . 5[...]
-
Page 21
P ocket R efeRence G uide — 21 KEYST ROKE D I S P L AY O O 0. 1 5 L + 15 . mL 2 5 L + 40 . mL 4 5 L = 85 . mL r = 85 . mL + 15 . mL + 25. mL + 45 . mL = 85 . mL USING THE CONVERSIONCALC PLUS USING THE 2 ND AND 3 RD FUNCTION KEY S The p r imar y keys are us ed to ac c es s miscellane ous calculator func tions and to ente r num er ic val ues a nd u[...]
-
Page 22
P ocket R efeRence G uide — 23 ENTERING DIMENSIONS AND UNITS When entering feet-inch dimensional value s, you m ust e nter t he la rge st dime nsi on r st — feet b efo re inc he s, inc he s bef ore f ra ct io ns. T o enter f ra ct io ns of an i nc h, ente r th e nume rat or (value a bove th e lin e ), pr es s / (Frac ti on B ar key) and the[...]
-
Page 23
P ocket R efeRence G uide — 23 (cont’d) 5 feet 1-1 /2 i nch 5f1i1/2 10 y a r ds 10y 1 7. 5 m e t e r s 17 .5m Square and Cubic Dimensions For square dimensions, enter the value and press the unit key twice. For cubic dimensions, press the unit key three times. DIMENSIO N KEYST ROKE 33 s quar e mete rs 33mm 5.5 cubic met ers 5. 5mmm 1 3 0 sq uar[...]
-
Page 24
P ocket R efeRence G uide — 25 375L+ 385L+ 65L= 375 . mL 760 . mL 825 . mL 2. C onver t to oth er uni ts: Tl ( microliters ) 8250 0 0. mc L f (c u b i c f e e t) 0 . 0 2 913 5 CU FE ET i (cubic in ches) 50.34459 CU I NC H F ( ui d oun ces) 27 .8 9 65 7 F- OZ G (gallons) 0.217942 GAL Not e: C on tin ue d pr ess es of o the r un its o f vol um e[...]
-
Page 25
P ocket R efeRence G uide — 25 (cont’d) c 5655.31 CM M 5 6 5 5 3 .1 MM k 0.05 6 55 3 k M N 0.03 51 4 MILE Area Conversion Enter 125 squar e me ters a nd c onver t to oth er un its of a rea: KEYST ROKE D I S P L AY OO 0. 125mm 12 5 SQ M y 1 49.4988 SQ Y D f 13 4 5 . 4 8 9 SQ FE ET i 193 75 0 . 39 SQ I NC H N 0.00 0 0 48 SQ M IL E c 1 250000. SQ [...]
-
Page 26
P ocket R efeRence G uide — 27 m 2 .1 2 3 7 6 3 CU M S0 (Board Feet) 90 0. BDFT S6 (Acre Feet) 0.001722 ACF T Enter 15 lit ers an d co nver t t o oth er uni ts of vo lum e: KEYST ROKE D I S P L AY OO 0. 1 5 l 1 5 L F ( ui d oun ces) 507 . 2103 F- OZ Tm (qu a r t) 1 5. 85 0 32 QT L (milliliters ) 1 5000. mL Enter 3 . 5 cup s and co nver t to o [...]
-
Page 27
P ocket R efeRence G uide — 27 25Ti (d r a m s) 25 DRAM L (milliliters ) 9 2 . 417 2 8 mL Tl ( microliters) 924 17 .2 8 mcL TL ( nanoliters ) 9 . 2 417 3 07 nL Ty (drops o r gt ts) 1 386.259 GTT S Adj ust t he def aul t to 20 d ro ps pe r cub ic c enti me ter . En ter 25 d ram s and co nver t to o ther u ni ts of vo lum e. KEYST ROKE D I S P L AY[...]
-
Page 28
P ocket R efeRence G uide — 29 Weight Conversion Enter 1,2 0 0 pou nds an d co nver t t o othe r uni ts of we igh t: KEYST ROKE D I S P L AY OO 0. 1200p 1 200 LB t 0. 6 To n S1 (metric tons ) 0. 54431 1 ME T To n d 1 920 0. D- OZ K 54 4.3 10 8 k G g 5443 10 . 84 GRAM Enter 75 0 mi ll igr am s and c onver t to othe r uni ts of we igh t: KEYST ROKE[...]
-
Page 29
P ocket R efeRence G uide — 29 Weight/V olume Conversions The C onve rsionCalc Plus can co nver t b et we en Weig ht and Volum e. T o re c all Wei ght p er Volume f ac tor press T% . Co nti nue pr es sin g % to dis play as p oun ds, g rai ns, m etr ic tons, kilograms, grams, mill igrams or tons . The d efau lt wei ght p er Volume fac t or i s: ?[...]
-
Page 30
P ocket R efeRence G uide — 31 T o c han ge t he Weig ht pe r Volume fac tor, enter th e value, t he n pre ss T% . Th e r st p res s wi ll ent er th e Weight a s the c a lc ulato r ’s cur ren t set ti ng. T o ch ang e th e Weight p er Volume fa cto r , c ont inu e to pr es s the % key to cyc le t hro ugh t he f act or s show n ab ove. Whe n [...]
-
Page 31
P ocket R efeRence G uide — 31 (cont’d) *Continue pre ssing % unt il L B Per C U FEET is shown. 6TM (Cup ) 6 CUP p 2. 8 52 40 9 LB Not e: To retur n we ig ht /vo lu me f ac tor t o def aul t se t ti ng of 6 2 .4279 6 p ou nds p er cu bi c foo t, p er for m a C lea r Al l by pr ess i ng S * . T emperature Conversion Enter 212° Fahr enh eit a nd[...]
-
Page 32
P ocket R efeRence G uide — 33 Sl (li ters p er second) 0.0 82017 L/S SL (mill il ite rs p er second) 82 . 01 72 6 m L /S Pressure Conversion Enter 3 4 5 ki lo pas cal s and c onver t to other units of pressure : KEYST ROKE D I S P L AY OO 0. 345 SK (kilopascals) 34 5 K PA Co nver t to o ther u ni ts of pr ess ur e: Sg (megapascals ) 0.3 4 5 M PA[...]
-
Page 33
P ocket R efeRence G uide — 33 (cont’d) 150Sk (kilometers per hour) 1 5 0 KM/H SN (mi l es per hour) 93.2056 8 MPH Sm (me te r s per minut e) 2500. M/M Sc (me te r s per second) 4 1.66667 M/S SM ( millimeters per second) 4 1666.67 MM/S Sy (feet per minute ) 8202. 1 FPM Sf (fee t per second) 1 36 .70 1 7 FPS Si (inches per second) 1 64 0.42 IPS [...]
-
Page 34
P ocket R efeRence G uide — 35 Energy Conversion Enter 2 25 ki lo ca lor ie s and c onver t to Jou les a nd B ri tis h the rm al un its: KEYST ROKE D I S P L AY OO 0. 225T6 (kilocalories) 225 KCA L Co nver t to o ther u ni ts of en erg y: T4 ( Joules) 941 40 0. JOUL T5 (Br i tis h thermal units ) 892 .8 721 BTU Power Conversion Enter 175 kilowa t[...]
-
Page 35
P ocket R efeRence G uide — 35 APPENDIX DEF AUL T SETTINGS Af te r a Cle ar A ll ( S* ), your ca lc ulato r wi ll ret ur n to th e fol low in g settings: STOR ED VALUES DEF AUL T V ALUE Weight p er Vo l u m e 62 . 42 79 6 LB/ CU F T Dro ps (gt t s ) p er cubic centimeter 15 . P er CU CM If you r epl ac e your b at ter y or pe r f or m a Full Rese[...]
-
Page 36
P ocket R efeRence G uide — 37 A UTO SHUT -OFF Y o ur c alc ula tor w ill s hut it se lf of f af ter abo ut 8 -1 2 mi nute s of no n- u se. ACCURA CY/ERRORS Accuracy/Display Capacity Y o ur c alc ula tor h as a t wel ve dig it disp lay. This is ma de up of e ig ht dig its (norm al di spl ay ) a nd fo ur fr ac ti ona l digi ts . Y o u may ente r o[...]
-
Page 37
P ocket R efeRence G uide — 37 Auto-Range If an “ove r ow ” i s cr eate d be ca use of a c alc ula tio n wi th sm all u nit s th at are o ut of th e st and ard d igi t ran ge of th e disp lay , t he an swer w ill b e auto mat ic all y expr es sed i n the n ex t lar ger u nit s (ins tead o f show in g “ O FLO ” ) – e.g., 20,0 0 0, 0 [...]
-
Page 38
P ocket R efeRence G uide — 39 RESET If you r ca lc ulat or sh oul d ever “ lo ck up, ” p res s Res et – a sma ll ho le loc at ed be low t he o key – to per for m a to tal r es et. RE PAIR A N D R E TU R N RETURN GUIDELINES 1. Pl eas e rea d th e War rant y in thi s Use r ’s Guide t o deter m ine i f your Cal cul ate d Indu str i es p r[...]
-
Page 39
P ocket R efeRence G uide — 39 (cont’d) W ARRANTY Cal cul ate d Indu str i es ( “C I” ) war ra nts thi s pro du ct ag ain st def ec ts in mate ri als a nd wo rk man shi p for a per i od of o ne (1 ) year f ro m the d ate of original consumer purchase in the U.S . If a def ec t exis ts du ri ng th e war ran t y per i od, CI , at it s opt io [...]
-
Page 40
P ocket R efeRence G uide — 41 A rep aire d or r epl ac em ent pr od uct assumes the remaining warrant y of th e or igi nal p ro duc t or 9 0 d ays, whichever is longer . Non-W arranty Repair Service — U.S.A. No n- wa rr ant y r epa ir c over s ser vic e beyon d the wa r rant y p er io d, or ser vic e re que ste d due to d ama ge res ult ing f [...]
-
Page 41
P ocket R efeRence G uide — 41 Disclaimer CI M A KES N O WAR R A N T Y O R REPR ESE NT A TI ON , EITH ER E XPR ES S OR I M PLIED, WI TH RES PECT TO THE PR OD UCT ’ S QUA LIT Y , PERFO RM A N CE, MER CH A NT A BI LIT Y , OR FIT N ESS FOR A PARTI CU L A R PU RP OS E. AS A RES UL T , T HI S PRO DU CT , IN CLU DI NG BU T NOT LI MI TED TO, KEYST ROK[...]
-
Page 42
P ocket R efeRence G uide — 43 Som e st ates d o not a llo w the exc lusi on or limi tation of implied warranties or liab ili t y for i nc ide nt al or c o nse que ntia l dama ge s, so t he ab ove lim ita ti on or exclus io n may not ap pl y to you. T his war ran t y give s you sp ec i c r igh ts, a nd you may al so have ot her r i ght s, wh i[...]
-
Page 43
P ocket R efeRence G uide — 43 4840 Hytech Drive Carson City , NV 89706 U.S.A. 1-775-885-4900 Fax: 1-775-885-4949 E-mail: info@calculated.com www .calculated.com PRG8030E-A.indd 43 8/21/2012 11:39:53 AM[...]
-
Page 44
Desi gn ed in the United St at es of A mer ica. PR G 8030 E- A Printed in China PRG8030E-A.indd 44 8/21/2012 11:39:53 AM[...]