Chamberlain RESIDENTIAL GATE OPERATOR GA400D manual
- Read online or download the manual
- 48 pages
- 1.87 mb
Go to page of
Similar user manuals
-
Safety Gate
Chamberlain HS670
36 pages 3.28 mb -
Safety Gate
Chamberlain SW 2000-X3
48 pages 4.56 mb -
Safety Gate
Chamberlain GA420D
48 pages 10.19 mb -
Safety Gate
Chamberlain LIFTMASTER PROFESSIONAL SW470
40 pages 1.23 mb -
Safety Gate
Chamberlain RESIDENTIAL GATE OPERATOR GA400D
48 pages 1.87 mb -
Safety Gate
Chamberlain SL 1000-XI
39 pages 1.73 mb -
Safety Gate
Chamberlain LA412-S
48 pages 7.94 mb -
Safety Gate
Chamberlain Swing GATE
54 pages 2.68 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Chamberlain RESIDENTIAL GATE OPERATOR GA400D, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Chamberlain RESIDENTIAL GATE OPERATOR GA400D one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Chamberlain RESIDENTIAL GATE OPERATOR GA400D. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Chamberlain RESIDENTIAL GATE OPERATOR GA400D should contain:
- informations concerning technical data of Chamberlain RESIDENTIAL GATE OPERATOR GA400D
- name of the manufacturer and a year of construction of the Chamberlain RESIDENTIAL GATE OPERATOR GA400D item
- rules of operation, control and maintenance of the Chamberlain RESIDENTIAL GATE OPERATOR GA400D item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Chamberlain RESIDENTIAL GATE OPERATOR GA400D alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Chamberlain RESIDENTIAL GATE OPERATOR GA400D, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Chamberlain service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Chamberlain RESIDENTIAL GATE OPERATOR GA400D.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Chamberlain RESIDENTIAL GATE OPERATOR GA400D item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
RESIDENTIAL GATE OPERATOR Models GA400D and GA420D For Residential Use Only The Chamberlain Group, Inc. 845 Larch Avenue Elmhurst, Illinois 60126-1196 www.chamberlain.com Owner’s Manual ■ Please read this manual and the enclosed safety materials carefully! ■ Periodic checks of the operator are required to ensure safe operation. ■ The model [...]
-
Page 2
Introduction 2 TABLE OF CONTENTS When you see these Safety Symbols and Signal Words on the following pages, they will alert you to the possibility of serious injury or death if you do not comply with the warnings that accompany them. The hazard may come from something mechanical or from electric shock. Read the warnings carefully. When you see this[...]
-
Page 3
Operator Specifications Main Supply (Motor) 12Vdc Battery run. Operational between 11.5Vdc and 14.5Vdc. Accessory Power 12V nominal Class II battery voltage source is limited to: • Solar or AC Cable up to 50' - 500 mA • AC Cable 50' up to 250' - 250mA • AC Cable 250' up to 1000' - 100mA NOTE: Increased accessory power[...]
-
Page 4
Introduction 4 1. READ and FOLLOW all instructions. 2. The gate operator is intended for use with Class I vehicular swing gates. Class I denotes a vehicular gate operator (or system) intended for use in a home of one to four single family dwellings, or a garage or parking area associated therewith. Install the gate operator only when the operator i[...]
-
Page 5
5 Introduction T o pre vent S ERIOUS INJURY or DE ATH from a mov ing g ate : • Inst a ll war ning si gns on t he fr ont a nd ba ck of t he ga te in PL AIN VIE W. • Perm ane ntl y s ecure e ach w arn ing sign in a sui t abl e manner using f as tening hole s. ATTENTION AVERTISSEMENT AVERTISSEMENT AVERTISSEMENT WARNING WARNING CAUTION WARNING WARN[...]
-
Page 6
Carton Inventory This operator comes with the hardware to install on a gate that pulls-to-open . If your application requires the gate to be pushed open , accessory kit 919GA is required. Introduction 6 Hardware Inventory NOTE: Hardware quantities shown below are for GA400D. Quantities are doubled for GA420D. Moving Gate Can Cause Injury or Death K[...]
-
Page 7
All Models: SAFETY SENSORS The Safety Sensors, model 916GA, are intended for installation with the operators covered in this manual. To order call: 1-866-826-4943 or visit www.chamberlain-diy.com. HARDWARE • 5/16" mounting hardware for gate bracket. • The following hardware is needed to mount the control box depending on the mounting surfa[...]
-
Page 8
Movi ng G at e Can Cau se Inju ry or D eat h KE EP C LEA R! Gat e m ay move at any t im e w i t ho ut pr i or warni ng. D o n ot let chi ldre n o per ate t he gate or play i n the gat e area. T hi s e n t r ance is f or v ehi cles onl y P ede s t ri ans m ust use separat e e nt ranc e Preparation and Overview 8 Mo v i ng Gate Ca n Ca u se Injury or[...]
-
Page 9
9 Preparation and Overview Dual Gate Overview Outside Property Inside Property Movi ng G at e C a n Cause Inju ry o r De at h K EE P C L E AR! Gate m ay m ove a t a ny t ime wi thou t pri or w ar ning . Do no t l et childre n o pera te t he g a te or play i n the gat e area. T hi s en t r ance is f or vehi cles onl y P edes t ri ans m ust use s epa[...]
-
Page 10
Check Your Gate Gate MUST swing freely and be supported entirely by its hinges. Remov e ANY/ALL wheels from the bottom of gate . Gate MUST NO T hit or drag across g round. Gate MUST be le v el. Gate and gate post MUST be plumb . Preparation and Overview 10[...]
-
Page 11
Gate Travel Determine how your gate is to be opened. 11 Preparation and Overview Pull-to-Open Push-to-Open Inside P roper t y Inside P roper t y Out side Proper t y Out side Proper t y Dir ec t ion o f Gate T r avel Dir ec t ion o f Gate T r avel Gate opens into the property. Bracket for Pull-To-Open installation is provided. Gate opens away from t[...]
-
Page 12
T ypical T ubular Metal Gate T ypical T ubular Metal Gate T ypical Wood Gate T ypical Wood Gate T ypical F ar m/Ranch Gate T ypical F ar m/Ranch Gate T ypical Chain Link Gate T ypical Chain Link Gate Preparation and Overview 12 Recommended: Mounting Options Mounting locations vary depending on type and style of your gate. NOTES: • The top of oper[...]
-
Page 13
INSTALLATION Attach Operator to Gate 13 Installation Identify Hinge Type The illustrations below show common gate hinges. There are many styles of hinges available. Gate P ost Gate P ost Gate P ost J-Bolt Hinge P oint J-Bolt Hinge P oint Butt Hinge P oint Barrel Hinge P oint J-Bolt Hinge Barrel Hinge Butt Hinge Top View Butt Hinge P oint Gate P ost[...]
-
Page 14
Installation 14 Measuring and Marking for the Gate Bracket Before proceeding, begin with the gate in the fully closed position. There are two methods described to determine proper location of the post brackets: • Paper template (to be cut out) located on the back page of this manual. • Tape measure. Either method will work depending on preferen[...]
-
Page 15
15 Installation Position the Extension Bracket to Post Bracket Hold post bracket in desired position. Align extension bracket to a position as CLOSE AS POSSIBLE above the marker. Assemble post bracket by placing the extension bracket on top of post bracket. Insert bolt through brackets and fasten with flange nut. DO NOT TIGHTEN AT THIS TIME. 3 Left[...]
-
Page 16
“Slowly extend the piston 1/4" (.64 cm) from collar and draw a mark.” THIS SIDE TO GA T E Screws Remove Motor Assembly Remove screws (4) and remove motor assembly. Set motor aside and place in clean, dry location. NOTE: Turn operator over to remove screws. Installation 16 4 5 Determine Maximum Piston Travel To ensure proper operation, it i[...]
-
Page 17
17 Installation Position Gate Bracket Hold the gate operator against the gate. The gate operator (arm) must be level. Clamp bracket to gate. Some installations require a reinforcement be installed on the gate. Attach Brackets to Gate Operator Attach post bracket to gate operator using hex head shoulder bolt and lock nut with nylon insert. Attach ga[...]
-
Page 18
Check Piston Travel Visually check the clearance. Holding the gate firmly, slowly walk the gate to the fully open position. Check for pinch points at the post mount area. Allow a minimum of 1/4" between the post bracket and operator. Adjust gate bracket if the piston marks are not visible in both the open and close direction. Tighten both bolt[...]
-
Page 19
19 Installation Secure the post bracket to gate post using hardware. The gate operator (arm) must be level. Secure Gate Bracket to Gate Remove the operator from the brackets. Mark and drill holes in gate or reinforcement (if necessary) according to gate bracket mounting hardware. Secure the gate bracket to gate using hardware (not provided). NOTE: [...]
-
Page 20
Moving Gate Can Cause Injury or Death KEEP CLEAR! Gate may move at any time without prior warning. Do not let children operate the gate or play in the gate area. This entrance is for vehicles only Pedestrians must use separate entrance THIS SIDE TO GA TE Attach Operator to Gate and Bracket Make sure “ THIS SIDE TO GATE ” label faces the gate wh[...]
-
Page 21
21 Installation The control box MUST be mounted within 5' of the gate operator. Mount the control box as high as possible for best radio reception. Mount the Control Box Open the Control Box Remove screws and open the control box. RE SE T Remove the Control Board Disconnect reset button, alarm and coaxial connector. Loosen screws and remove co[...]
-
Page 22
Mount the Control Box Secure the control box to mounting surface (post, wall, column, etc.) using appropriate hardware (not provided). Install the Control Board Attach antenna. Reinstall batteries, control board, alarm, and reset button. Reconnect coaxial connector. NOTE: Make sure battery leads are on the left side of the control box and not pinch[...]
-
Page 23
Mo vin g G a te C an C ause Movi ng Gate C an Cause I njur y or Death I nj ury or Death KEEP CL EAR! K EE P C LEA R! Ga te may move a t any G ate m ay move at any tim e w ith o u t pri or wa rn in g. ti m e wi tho ut prior w arning. Do n o t le t ch i ld ren op era te th e ga te o r D o n ot l e t c hi l d r e n ope rate th e gate or p lay in th e [...]
-
Page 24
Wiring 24 Connect Operator to Control Board Extend operator cable and wires to GATE 1 connector and connect as shown. Tighten watertight connector nut. Mo vin g G a te C an C aus e I njur y or Death KEEP CL EAR! Ga te may move a t any tim e w ith o u t pri or wa rn in g. Do n o t le t chi ld ren op era te th e ga te or p lay in th e gate area. This[...]
-
Page 25
Occasionally in dual gate installations, one gate would need to open first and close second. This would happen if there was an ornamental overhang on one gate or if using a solenoid lock, for example. This gate is called the Primary gate and needs to be connected to Gate 1 connections on the control board. Thus, it is preferred that the control box[...]
-
Page 26
Connect second Operator to Control Board (Model Ga420D Only) • Before digging, contact local underground utility locating companies. • Trench across driveway to bury the extension cable. • Use PVC conduit to prevent damage to cables. • Insert extension cable through watertight connector nut and through an available watertight connector moun[...]
-
Page 27
27 Wiring Junction Box The f ollowing items are required to complete the junction bo x (not provided) installation: • 4 x 4 Junction Box with 3/4 NPT threaded port holes • Screws • PVC Conduit Open the junction box by removing screws (4) and set aside. Mount the junction bo x within 5' of second operator . 2 M ovin g G at e C an C au se [...]
-
Page 28
Secure Junction Box Put wires inside of junction box. Secure operator and extension cables with watertight nut. Reinstall cover. Connect Wires in Junction Box Remove terminals from operator cable. Strip wires and twist like colored wires together with wire nuts. Wiring 28 3 4 5 Connect Watertight Connectors Route operator cable and extension cable [...]
-
Page 29
29 Wiring Moving G at e C an C au se I njur y o r D e at h KE E P C L E AR ! G a t e m a y m o v e a t a n y t im e w i t h o u t p r i o r wa rn i n g . D o n o t l e t c h il d r e n o p e r a t e th e g a t e o r pl a y i n t h e g a t e a r e a . Th i s e n t r a n c e i s f o r v e h i c l e s o n l y Pe d e s t r ia n s m u s t u se s e p a r[...]
-
Page 30
Wiring 30 18 18 R93 L1 L1 K2 K2 Z22 Z22 P1 P1 F2 F2 MOV1 MOV1 D1 D1 Q12 Q12 U4 U4 OFF OFF MAX MAX OPEN SINGLE BUTTON RESET STOP CHGR OVLD CTRL PWR COM D129 D129 Z4 Z4 U3 U3 D2 D2 D44 D44 C11 C11 C13 C13 C12 C12 D16 D16 F9 F9 R1 R1 Ø 1 R1 R1 ØØ ØØ Q22 Q22 F3 F3 K3 K3 K4 K4 R196 R196 F1 F1 GATE 2 GATE 2 GATE 1 GATE 1 GR GR WH WH YL YL BL BL RD R[...]
-
Page 31
31 Wiring Connect Batteries The batteries are charged in circuit by using the transformer (provided). Locate the two white battery plugs on the left-hand side of the control box. Connect the plug from the battery to connector on the control board. NOTES: Batteries will degrade over time depending on temperature and usage. For best performance, the [...]
-
Page 32
Test the limits by pressing the SBC to open and close the gate. NOTE: If the SET OPEN LIMIT LED is still blinking, the limits were not programmed successfully. Repeat the programming making sure the gate is fully opened and closed for each respective limit. If the problem persists, refer to the Troubleshooting section. PROGRAMMING Program Limits Th[...]
-
Page 33
NOTES: • If one gate is overlapping the other, the gate that is overlapping must be connected to GATE 1 so it will start moving before the other gate; gate 2 may need to be closed fi rst if there is overlap or a gate lock is being used. • The programming can be exited at any time by pressing the RESET button. Programming times-out automaticall[...]
-
Page 34
Force/Timer to Close/Party Mode Controls Without a properly installed safety reversal system, persons (particularly small children) could be SERIOUSLY INJURED or KILLED by a closing gate. • Too much force on gate will interfere with proper operation of safety reversal system. • NEVER increase force beyond minimum amount required to close gate. [...]
-
Page 35
Z22 R91 CLOSE EDGE R94 R92 R93 L1 R1 R2 Z1 K5 K6 K2 F3 10A 32V D1 Ø OPEN EDGE/ PHO T O OPEN PHO T O CLOSE PHO T O R227 R2 Ø 7 Z2 Ø R223 P1 Z9 Z8 F2 F6 D4 R9 R224 U4 CONTROL INPUTS FORCE TIMER TO CLOSE OFF MAX OPEN SINGLE BUTTON RESET STOP SHADOW INTERRUPT CHGR OVLD COM COM COM LOOP INPUTS POWER F1 20A 32V R35 D9 Z3 Z4 U3 C11 C13 C12 D15 C2 R4 R1[...]
-
Page 36
Operation and Maintenance 36 Using Your Gate Operator Your operator will operate with up to nine Security ✚ ® remote controls and one Security ✚ ® Keyless Entry System. If you purchase a new remote, or if you wish to deactivate any remote, follow the instructions in the Programming section. Activate your operator with any of the following: Ha[...]
-
Page 37
Release Pin Gate Brack et 37 Operation and Maintenance Manual Release In case of a power failure, the operator can be disengaged from the gate. Follow the directions below to disconnect and reconnect the operator to the gate. Release 1. Remove the hairpin clip and release pin that secures the gate bracket to the gate. 2. Move operator away from gat[...]
-
Page 38
Operation and Maintenance 38 * Class 2 circuit 15 v maximum output 2. Close edge 3. Open edge/photo e ye 4. Open photo e ye 5. Close photo e ye 6. Control inputs 7. Loop inputs 10. Accessor y power 12. Automatic gate loc k 13. F ault alarm To protect against fire and electrocution: • DISCONNECT power and battery BEFORE installing or servicing ope[...]
-
Page 39
39 Operation and Maintenance Your gate operator is programmed with self-diagnostic capabilities. The diagnostic LED will flash a number of times then pause signifying it has found a potential issue. Consult Diagnostic Chart below. Normal Operation Stop is not connected. • Press the RESET button and make sure the STOP LED turns on. • Check to ma[...]
-
Page 40
Operation and Maintenance 40 SYMPTOM POSSIBLE SOLUTION Operator does not run. • P ower not connected. Make sure the A C/Solar input is connected and that at least Diagnostic LED not on. one batter y is connected with the corresponding fuse intact. • Low or def ective batter y . Chec k the batter y to make sure that the red wire goes to the posi[...]
-
Page 41
41 Operation and Maintenance SYMPTOM POSSIBLE SOLUTION The ar m mov es b ut cannot • Arm does not extend or contr act enough during trav el. The ar m piston must e xtend e xit Learn Limits mode. and contract close to its full length to Learn Limits. Adjust the ar m mounting so that Cannot lear n limits. this can be achiev ed. • Motor cable wire[...]
-
Page 42
Operation and Maintenance 42 SYMPTOM POSSIBLE SOLUTION Gate opens but does not • An open input is continuously activ ated. Check the open loop or v ehicle probe to close. make sure the y are clear of objects . V erify connections and operation f or these de vices. • Low battery . Measure the v oltage across the batter y . V oltage should be abo[...]
-
Page 43
43 Operation and Maintenance 3 6 4 2 1 5 ITEM PART # DESCRIPTION QTY 1 K1A6426 Control Board with Mounting Bracket 1 2 K23-19380 Reset Switch 1 3 K74-34392 Antenna 1 4 922GA Battery with Harness 1 5 K204B0195 Indoor Transformer 1 6 K29-20095 Alarm 1 Not Shown K74-33975 Complete Control Box (without battery) 1 K1A5747 Receiver Module - 315MHz 1 K1A5[...]
-
Page 44
Operation and Maintenance 44 1 2 ITEM PART # DESCRIPTION QTY 1 K-41ADBL-0004 Arm Cover 1 2 K-LA-6 Complete Arm Assembly Includes: Arm, Motor and Plastic Cover 1 Not Shown K-DBL-0095SA Hardware Kit Includes: One Extension Bracket, One Gate Bracket, One Post Bracket and One Hardware Bag) 1 01-33859 Owner’s Manual 1 01-33859SP Owner’s Manual - Spa[...]
-
Page 45
OPEN OPEN CLOSE OPEN OPEN CLOSE OPEN OPEN CLOSE 45 Operation and Maintenance OPEN OPEN CLOSE 940D 956D 953D Automatic Gate Lock: Solenoid-driven lock that automatically unlocks when gate is open and locks when gate is closed. Can be mounted onto gate or post. Can be released in case of emergency. 915GA 921GA Vehicle Exit Sensor: One piece outdoor b[...]
-
Page 46
Warranty 46 HOW TO ORDER REPAIR PARTS OUR L A RGE SERVIC E ORGA NIZ ATION SP ANS A MERIC A INSTALL A TION A ND SERV ICE INF ORM A TION CALL OUR TOLL FRE E NUM BER 1 -866-826- 494 3 w w w.chamber lain.c om WHEN ORDER IN G REP AIR P A RTS PL E AS E SU PP L Y TH E FO LL OW ING I NF ORM ATIO N: P ART N UM BER DESCR IPTION MODE L NU MBE R ADDR ESS ORDER[...]
-
Page 47
NOTES 47 Notes[...]
-
Page 48
© 2009, The Chamberlain Group, Inc. 01-33859D All Rights Reserved TEMPLATE FOR POST BRACKET MOUNTING 1 32 4 5 13 24 5 5 3/4" 5 3/4"[...]