Go to page of
Similar user manuals
-
Computer Drive
Cisco Systems GEM318P
74 pages 0.81 mb -
Computer Drive
Cisco Systems A03D600GA2
80 pages 3.3 mb -
Computer Drive
Cisco Systems 2008M-8i
13 pages 0.21 mb -
Computer Drive
Cisco Systems WUSB54GC
33 pages 1.91 mb -
Computer Drive
Cisco Systems CPDX650K9
146 pages 4.5 mb -
Computer Drive
Cisco Systems UCSCRAIDMZ220
13 pages 0.21 mb -
Computer Drive
Cisco Systems A03D600GA2
146 pages 4.5 mb -
Computer Drive
Cisco Systems ST373307LC
74 pages 0.81 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Cisco Systems A03D600GA2, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Cisco Systems A03D600GA2 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Cisco Systems A03D600GA2. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Cisco Systems A03D600GA2 should contain:
- informations concerning technical data of Cisco Systems A03D600GA2
- name of the manufacturer and a year of construction of the Cisco Systems A03D600GA2 item
- rules of operation, control and maintenance of the Cisco Systems A03D600GA2 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Cisco Systems A03D600GA2 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Cisco Systems A03D600GA2, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Cisco Systems service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Cisco Systems A03D600GA2.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Cisco Systems A03D600GA2 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
C ISCO S YSTEMS P UBLICATION H ISTORY 170 W EST T ASMAN D R S AN J OSE , CA, 95134 R EV C.18 D ECEMBER 17, 2013 WWW . CISCO . COM Spec Sheet Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)[...]
-
Page 2
Cisco UCS C220 M3 High-Density R ack Serv er (Small Form Fact or Disk Drive Model) 2 OVERVIEW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 DETAILED VIEWS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Chassis Front View . . . . . . . . . . . . . . . . . . . [...]
-
Page 3
Cisco UCS C220 M3 High-Dens ity Rac k Serv er (Small Form Factor Disk D rive Model) 3 CONTENTS Power Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76 Environmental Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79 Compliance Requir[...]
-
Page 4
Cisco UCS C220 M3 High-Density R ack Serv er (Small Form Fact or Disk Drive Model) 4[...]
-
Page 5
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) OVERVIEW 5 OVER VIEW The Ci sco® U CS C22 0 M3 rac k serve r is de signed for performance and density over a wide range of business workloads from web serving to distributed database. The enterprise-class UCS C220 M3 server extends th e capabilities of Cisco?[...]
-
Page 6
Cisco UCS Cisco UCS C22 0 M3 High-Density Rac k Server (Small Form Factor Disk Drive Model) 6 DETAILED VIEWS DET AILED VIEWS Chassis Front Vi ew Figure 2 shows the Cisco UCS C220 M3 Hig h-Density SFF Rack Server . Figure 2 Chassis Front V iew For more information about th e KVM cable connection, see KVM CAB LE, page 74 . 1 P ower button/power statu[...]
-
Page 7
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) DETAILED VIEWS 7 Chassis Rear Vi ew Figure 3 shows the externa l features of the rear panel. Figure 3 Chassis Rear V iew 1 P ower supplies (up to two) 6 One 10/100/1000 Ethernet dedicated management port 2 Slot 2: Low-profile PCIe slot on riser: (half-height, [...]
-
Page 8
Cisco UCS Cisco UCS C22 0 M3 High-Density Rac k Server (Small Form Factor Disk Drive Model) 8 BASE SERVER STANDARD CA PABILITIES and FEATURES BASE SER VER ST ANDARD CA P ABILITIES and FEA TURES Ta b l e 1 lists the capabilities and features of the base server . Details abou t how to configure the server for a particular feature or capability (f or [...]
-
Page 9
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) BASE SERVER STANDARD CAPABILITIES an d FEATURES 9 Vid eo The Emulex Pi lot 3 Integrated Basebo ard Management Cont roller provides video: ■ Matrox G200e video controller ■ Integrated 2D graphics core with hardware acceleration ■ Supports all display reso[...]
-
Page 10
Cisco UCS Cisco UCS C22 0 M3 High-Density Rac k Server (Small Form Factor Disk Drive Model) 10 BASE SERVER STANDARD CA PABILITIES and FEATURES Interfaces ■ Re a r p a n e l • One RJ45 serial port connector • T wo USB 2.0 port connectors • One DB15 VGA connector • T wo RJ-45 10/100/1000 Ethernet port connectors • One RJ-4 5 10/100/1000 E[...]
-
Page 11
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) CONFIGURING the SERVER 11 CONFIGURING the SER VER Follow these steps to configure the Cisco UCS C220 M3 High-Density SFF Rack Server: ■ STEP 1 VERIFY SERVER SKU, page 12 ■ STEP 2 SELECT CPU(s), page 13 ■ STEP 3 SELECT MEMOR Y , page 16 ■ STEP 4 SELECT [...]
-
Page 12
Cisco UCS Cisco UCS C22 0 M3 High-Density Rac k Server (Small Form Factor Disk Drive Model) 12 CONFIGURI NG the SERV ER STEP 1 VERIFY SER VER SKU V erify the product ID (PID) of the server as show n in Ta b l e 2 . The Cisco C220 M3 server: ■ Includes one tool-less rail kit (UCSC-RAIL1) ■ Does not include power supply , CPU, memory , ha rd disk[...]
-
Page 13
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) CONFIGURING the SERVER 13 STEP 2 SELECT CPU(s) The standa rd CPU fea tures are: ■ Intel Xeon E5-2600 v2 and E5-2600 series proc essor family CPUs (see the fo llowing link for instructions on how to upgrade your server fr om Intel Xeo n E5-2600 to Intel Xeon [...]
-
Page 14
Cisco UCS Cisco UCS C22 0 M3 High-Density Rac k Server (Small Form Factor Disk Drive Model) 14 CONFIGURI NG the SERV ER Intel Xeon E5-2600 2 UCS-CPU-E5-2690 E5-2690 2.90 135 20 8 8 GT/s 1600 UCS-CPU-E5-2680 E5-2680 2.70 130 20 8 8 GT/s 1600 UCS-CPU-E5-2670 E5-2670 2.60 115 20 8 8 GT/s 1600 UCS-CPU-E5-2667 E5-2667 2.90 130 15 6 8 GT/s 1600 UCS-CPU-E[...]
-
Page 15
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) CONFIGURING the SERVER 15 Approved Configurations (1) 1-CPU conf igurations: ■ Select any one CPU listed in Ta b l e 3 . (2) 2-CPU Configur ations: ■ Select two identical CPUs fr om any one of the rows of Ta b l e 3 on page 13 . Caveats ■ Y ou can select[...]
-
Page 16
Cisco UCS Cisco UCS C22 0 M3 High-Density Rac k Server (Small Form Factor Disk Drive Model) 16 CONFIGURI NG the SERV ER STEP 3 SELECT MEMOR Y The standar d memory feat ures are: ■ DIMMs — Clock speed: 1866, 16 00, or 1333 MHz — Ranks per DIMM: 1, 2, or 4 — Operational voltage: 1.5 V or 1.35 V — R egistered or unbuffered ECC DDR3 DIMMs (RD[...]
-
Page 17
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) CONFIGURING the SERVER 17 Select DIMMs and Memory Mirroring Select the memory configuration and whether or not you want the memory mirroring option. The available memory DIMMs and mi rroring option are listed in Ta b l e 4 . NOTE: When memory mirroring is enab[...]
-
Page 18
Cisco UCS Cisco UCS C22 0 M3 High-Density Rac k Server (Small Form Factor Disk Drive Model) 18 CONFIGURI NG the SERV ER Approved Configurations (1) 1-CPU conf iguration wi thout memory mirroring: ■ Select from 1 to 8 DIMMs. Refer to Memory Population Rules, page 60 , for more detailed information. (2) 1-CPU configuration with memory mirroring: ?[...]
-
Page 19
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) CONFIGURING the SERVER 19 (4) 2-CPU configuration with memory mirroring: ■ Select 2, 4, 6, or 8 identical DI MMs per CPU. The DIMMs will be placed by the factory as shown in the following table. ■ Select the memory mirroring opti on (N01-MMIRROR) as show n[...]
-
Page 20
Cisco UCS Cisco UCS C22 0 M3 High-Density Rac k Server (Small Form Factor Disk Drive Model) 20 CONFIGURI NG the SERV ER Caveats ■ System speed is depende nt on how many DIMMs are populated per channel. See Ta b l e 5 for details. ■ For optimum performanc e, do not mix D IMMs wi th different frequencies. If you mix DIMM frequencies, the system d[...]
-
Page 21
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) CONFIGURING the SERVER 21 ■ By default, starting with UCSM 2.0.4, DIMM s run in memory performance mode (1.5v) by BIOS default, which yields fast er memory speeds than when the BIOS is set for the memory to run in power-savings mode. Memory sp eed is dep end[...]
-
Page 22
Cisco UCS Cisco UCS C22 0 M3 High-Density Rac k Server (Small Form Factor Disk Drive Model) 22 CONFIGURI NG the SERV ER STEP 4 SELECT RAID CONFIGURA TION The RAID contr oller choi ces are: (1) Embedded RAID (on motherboard) (2) Mezzanine RAID controller cards (n ot supported in 1-CPU conf igur ation s) (3) PCIe RAID controllers Cisco can provide fa[...]
-
Page 23
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) CONFIGURING the SERVER 23 Select RAID Options Select one of the following (these cho ices ar e dependent on the number of CPUs installed): ■ One embedded RAID upgrade option for internal drives, or ■ One mezzanine RAID controlle r for internal drives, or ?[...]
-
Page 24
Cisco UCS Cisco UCS C22 0 M3 High-Density Rac k Server (Small Form Factor Disk Drive Model) 24 CONFIGURI NG the SERV ER UCSC-RAID-11-C220 Cisco UCSC RAID SAS 2 008M-8i Mezzanin e Card (RAID 0, 1, 5, 10, and 50 supported), operating at 6 Gbs. ■ Supports up to eight internal SAS+SA T A drives. SAS and SA T A drives can be mixed. ■ Factory-configu[...]
-
Page 25
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) CONFIGURING the SERVER 25 UCS-RAID-9285CV -E or UCS-RAID9286CV -8E LSI MegaRAID SAS 9285CV -8e or 92 86CV -8e (RAID 0, 1, 5, 6, 10) ■ Supports from one to eight external SA S ports (up to 24 0 external drives). ■ Includes an chassi s-mount (remote) superca[...]
-
Page 26
Cisco UCS Cisco UCS C22 0 M3 High-Density Rac k Server (Small Form Factor Disk Drive Model) 26 CONFIGURI NG the SERV ER Approved Configurations The C220 M3 SFF server has an 8-drive backplane. ■ ROM5 and ROM55 embedded RAID upgrade op tions support up to 8 internal drives. ■ Mezzanine card (UCSC-RAID-11-C220) su pports up to 8 internal drives. [...]
-
Page 27
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) CONFIGURING the SERVER 27 See Ta b l e 9 for a summary of the supported RAID configuration options. T able 9 Supported RAID Configur ations Server # CPUs Embedded RAID Mezz RAID 1 Notes . . . 1. Never disable OPROM for the m ezzanine slot if the mezzanine card[...]
-
Page 28
Cisco UCS Cisco UCS C22 0 M3 High-Density Rac k Server (Small Form Factor Disk Drive Model) 28 CONFIGURI NG the SERV ER Caveats ■ Note that only a single Cisco VIC card (the half-height Ci sco VIC 1225 PCIe card) is supported and it must be installed in the full-height PCIe slot (slot 1) on riser 1. So take this into account when populating RAID [...]
-
Page 29
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) CONFIGURING the SERVER 29 STEP 5 SELECT HARD DISK DRIVES (HDDs) or SOLID ST A TE DRIVES (SSDs) The standard disk drive features are: ■ 2.5-inch small form factor ■ Hot-pluggable ■ Sled-mounted Select Drives The available drives are listed in Ta b l e 10 [...]
-
Page 30
Cisco UCS Cisco UCS C22 0 M3 High-Density Rac k Server (Small Form Factor Disk Drive Model) 30 CONFIGURI NG the SERV ER Approved Configurations (1) Onboard RAID, Mezza nine Cards, and all PCIe RAID Contro llers ■ If you have not selected an onboard RAID upgrade option (ROM5 or RO M55), a mezzanine card, or a PCIe RAID controller for internal dr i[...]
-
Page 31
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) CONFIGURING the SERVER 31 STEP 6 SELECT PCIe OPTION CARD(s) The standard PCie ca rd offerings are: ■ Converged Network Adapters (CNAs) ■ Network Interface Cards (NICs) ■ Host Bus Adapters (HBAs) ■ UCS Storage Accelerators Select PCIe Option Cards The a[...]
-
Page 32
Cisco UCS Cisco UCS C22 0 M3 High-Density Rac k Server (Small Form Factor Disk Drive Model) 32 CONFIGURI NG the SERV ER Approved Configurations (1) No PCIe RAID controller ■ If you did not choose a PCIe RAID controller (f or example, you are using embedded RAID or a mezzanine RAID controller ), you can select up to one PCie option card (for 1-CPU[...]
-
Page 33
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) CONFIGURING the SERVER 33 — Both PCIe slots (slo ts 1 and 2) and the mezza nine card slot are supp orted — Only a single VIC card (the half-height Ci sco VIC 1225 PCIe card) is supported and it must be installed in slot 1 (the full height slot). — Only a[...]
-
Page 34
Cisco UCS Cisco UCS C22 0 M3 High-Density Rac k Server (Small Form Factor Disk Drive Model) 34 CONFIGURI NG the SERV ER STEP 7 ORDER OPTIONAL NETWOR K CARD ACCESSORIES Copper twinax cables and SFP optical modules may be ordered to support the two-port network cards that are available with the server . Choose Optional T winax Cables Ta b l e 12 list[...]
-
Page 35
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) CONFIGURING the SERVER 35 Approved Configurations (1) Choose Up to T wo SFP+ Modules for Each Network Card Ordered ■ Y ou may choose one or two SF P+ optical module s cables for each compatible PCIe network card ordered. Y ou would normally order two modules[...]
-
Page 36
Cisco UCS Cisco UCS C22 0 M3 High-Density Rac k Server (Small Form Factor Disk Drive Model) 36 CONFIGURI NG the SERV ER T able 14 PCIe Card Compatibility PCIe Cards Tw i n a x Cables Cisco SFP Modules SFP-10G-SR DS-SFP-FC8G-SW Converged Network Adapters (CNAs) UCSC-PCIE-BSFP (Broadcom 57712 Dual P ort 10Gb SFP+ w/T OE iSCSI) Ye s Ye s No UCSC-PCIE-[...]
-
Page 37
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) CONFIGURING the SERVER 37 Figure 5 Network Card Connections[...]
-
Page 38
Cisco UCS Cisco UCS C22 0 M3 High-Density Rac k Server (Small Form Factor Disk Drive Model) 38 CONFIGURI NG the SERV ER STEP 8 ORDER POWER SUPPL Y The C220 M3 SFF server accommodates two power supplies. A lightly loaded server can operate from one 650 W power supply . A fully loaded server might need to be powered with two 450 W or two 650 W power [...]
-
Page 39
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) CONFIGURING the SERVER 39 STEP 9 SELECT AC POWER CORD(s) Using Ta b l e 16 , sele ct the appropriate AC powe r cords. Y ou can select a m inimum of no power cords and a maximum of two. If you select th e option R2XX-DMYMPWRCORD, no power cord is shipped with t[...]
-
Page 40
Cisco UCS Cisco UCS C22 0 M3 High-Density Rac k Server (Small Form Factor Disk Drive Model) 40 CONFIGURI NG the SERV ER SFS-250V -10A-AR P ower Cord, SFS, 250V , 10A, Argentina CAB-9K10A-AU P ower Cord, 250V AC 10A 31 12 Plug, Australia SFS-250V -10A-CN P ower Cord, SFS, 250V , 10A, China CAB-250V -10A-CN AC P ower Cord - 250V , 10A - PRC CAB-9K10A[...]
-
Page 41
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) CONFIGURING the SERVER 41 CAB-9K10A-IT P ower Cord, 250V AC 10A CEI 23-16/VII Plug, Italy CAB-9K10A-SW P ower Cord, 250V AC 10A MP232 Plug, Switzerland CAB-9K10A-UK P ower Cord, 250V AC 10A BS136 3 Plug (13 A fuse), UK CAB-9K12A-NA P ower Cord, 125V AC 13A NEM[...]
-
Page 42
Cisco UCS Cisco UCS C22 0 M3 High-Density Rac k Server (Small Form Factor Disk Drive Model) 42 CONFIGURI NG the SERV ER STEP 10 ORDER OPTIONAL REVERSIBLE CABLE MANAGEMENT ARM The reversible cable management ar m mounts on either the right or left slide rails at the rear of the server and is used for cable management. Use Ta b l e 17 to order a cabl[...]
-
Page 43
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) CONFIGURING the SERVER 43 STEP 11 ORDER A TRUSTED PLA TFORM MODULE (OPTIONAL) T rusted Platform Module (TPM) is a computer ch ip (microcontroller) that can securely stor e artifacts used to authenticate the platform (server). These ar tifacts can inc lude pass[...]
-
Page 44
Cisco UCS Cisco UCS C22 0 M3 High-Density Rac k Server (Small Form Factor Disk Drive Model) 44 CONFIGURI NG the SERV ER STEP 12 ORDER CISCO FLEXIBLE FLASH SD CARD MODULE (OPTIONAL) Y ou can order up to two optio nal preloaded 16 GB Cisco Flexi ble Flash secure di gital (SD) c ards. The first SD card contains preloaded software for simplified server[...]
-
Page 45
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) CONFIGURING the SERVER 45 STEP 13 ORDER OPTIONAL USB 2.0 DRIVE Y ou can order one optional USB 2.0 drive. The USB drive ordering inf ormation is listed in Ta b l e 21 . See Figure 6 on page 57 for the location of the USB connector . T able 21 USB 2.0 Drive Pro[...]
-
Page 46
Cisco UCS Cisco UCS C22 0 M3 High-Density Rac k Server (Small Form Factor Disk Drive Model) 46 CONFIGURI NG the SERV ER STEP 14 SELECT OPERA TING SYSTEM AND V ALUE-ADDED SOFTW ARE Several operating systems and value-added software programs are available. Select as desired from Ta b l e 22 . T able 22 OSs and V alue-Added Software (for 2-CP U server[...]
-
Page 47
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) CONFIGURING the SERVER 47 Red Hat Enterprise Linux RHEL-2S-1G- 1A RHEL/2 Socket/1 Guest/1Yr Svcs R equired RHEL-2S-1G- 3A RHEL/2 Socket/1 Guest/3Yr Svcs R equired RHEL-2S-4G- 1A RHEL/2 Socket/4 Guest/1Yr Svcs R equired RHEL-2S-4G- 3A RHEL/2 Socket/4 Guest/3Yr [...]
-
Page 48
Cisco UCS Cisco UCS C22 0 M3 High-Density Rac k Server (Small Form Factor Disk Drive Model) 48 CONFIGURI NG the SERV ER VMware 5 VMW -VS5-STD-1A VMware vSphere 5 Standard for 1 P rocessor , 1 Y ear , Support Rqd VMW -VS5-STD-2A VMware vSphere 5 Standard for 1 P rocessor , 2 Y ear , Support Rqd VMW -VS5-STD-3A VMware vSphere 5 Standard for 1 P roces[...]
-
Page 49
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) CONFIGURING the SERVER 49 STEP 15 SELECT OPERA TING SYSTEM MEDIA KIT Select the optional operating system media listed in Ta b l e 23 . Ta b l e 2 3 O S M e d i a Product ID (PID) PID Description RHEL-6 RHEL 6 R ecovery Media Only (Multilingual) SLES-11 SLES 1[...]
-
Page 50
Cisco UCS Cisco UCS C22 0 M3 High-Density Rac k Server (Small Form Factor Disk Drive Model) 50 CONFIGURI NG the SERV ER STEP 16 SELECT SER VICE and SUPPOR T LEVEL A variety of service opti ons are available, as des cribed in this section. Unified Computing W arranty , No Contr act If you have noncritical implementations and choose to have no servic[...]
-
Page 51
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) CONFIGURING the SERVER 51 SMAR Tnet for UCS Hardware Only Serv ice For faster parts replacement than is provided wi th the standard Cisco Un ified Computing System warranty , Cisco offers the Cisco SMAR Tnet for UCS Hardware Only Service. Y ou can choose from [...]
-
Page 52
Cisco UCS Cisco UCS C22 0 M3 High-Density Rac k Server (Small Form Factor Disk Drive Model) 52 CONFIGURI NG the SERV ER P artner Support Service for UCS provides hardwa re a nd software suppo rt, including triage support for third party software, backed by Ci sco technical resource s and level three support. See Ta b l e 26 . P artner Support Servi[...]
-
Page 53
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) CONFIGURING the SERVER 53 Y ou can choose a service lis ted in Ta b l e 28 . Unified Computing Drive Retention Service With the Cisco Unified Computing Drive R etentio n (UCDR) Service, you can obtain a new disk drive in exchange for a faulty drive without ret[...]
-
Page 54
Cisco UCS Cisco UCS C22 0 M3 High-Density Rac k Server (Small Form Factor Disk Drive Model) 54 CONFIGURI NG the SERV ER For more service and support info rmation, see the following URL: http://www .cisco.com/en/US /ser v ices/ps2961/ps1 0312/Unified_Computing_Se rvices_Overv iew .pdf For a complete listing of available services f or Cisco Unified C[...]
-
Page 55
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) OPTIONAL STEP - ORDE R RACK(s) 55 OPTIONAL STEP - ORDER RACK(s) The optional R42610 rack is available from Cis co for the C-Series servers, including the C220 M3 SFF server . This rack is a standard 19-inch rack and can be ordered with a variety of options, as[...]
-
Page 56
Cisco UCS Cisco UCS C22 0 M3 High-Density Rac k Server (Small Form Factor Disk Drive Model) 56 OPTIONAL STEP - ORDER PDU OPTIONAL STEP - ORDER PDU An optional power distribution unit (PDU) is avai lable from Cisco for the C-Series rack serve rs, including theC220 M3 server . This PDU is available in a zero rack unit (RU) style (s ee Ta b l e 30 ). [...]
-
Page 57
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) SUPPLEMENTAL MATERIAL 57 SUPPLEMENT AL MA TERIAL CHASSIS An internal view of the C220 M3 chassis with the top co ver removed is shown in Figure 6 . Figure 6 C220 M3 SFF With T op Cover Off 1 Drives (hot-swappable, accessed through front panel) 10 T rusted plat[...]
-
Page 58
Cisco UCS Cisco UCS C22 0 M3 High-Density Rac k Server (Small Form Factor Disk Drive Model) 58 SUPPLEMENTAL MATERI AL CPUs and DIMMs Physical Layout Each CPU has four DIMM channels: ■ CPU1 has channels A, B, C, and D ■ CPU2 has channels E, F , G, and H Each DIMM channel has two banks: bank 1 a nd bank 2. The blue-colore d DIMM slots a re for ba[...]
-
Page 59
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) SUPPLEMENTAL MATERIAL 59 Figure 7 Physical Layout of CPU DIMM Chan nels and Banks C1 C2 D1 D2 B2 B1 A2 A1 G1 G2 H2 H1 F2 F1 E1 E2 Front of Server CPU1 CPU2 331707[...]
-
Page 60
Cisco UCS Cisco UCS C22 0 M3 High-Density Rac k Server (Small Form Factor Disk Drive Model) 60 SUPPLEMENTAL MATERI AL Memory P opulation Rules When considering the memory config uration of your server , you should consider the following items: ■ Each channel has two DIMM slots (fo r example, channel A = slots A1 an d A2). — A channel can operat[...]
-
Page 61
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) SUPPLEMENTAL MATERIAL 61 DIMM P opulation Order P opulate the DIMMs for a CPU according to Ta b l e 33 . T able 33 DIMM P opulation Order per CPU DIMMs per CPU Po p u l a t e CPU 1 Slots Po p u l a t e CPU 2 Slots 1 A1 E1 2 A1, B1 E1, F1 3 A1, B1, C1 E1, F1, G[...]
-
Page 62
Cisco UCS Cisco UCS C22 0 M3 High-Density Rac k Server (Small Form Factor Disk Drive Model) 62 SUPPLEMENTAL MATERI AL Recommended Memory Configur ation This section ex plains the reco mmended DIMM population order rules for the C220 M3 server . ■ All DIMMs must be DDR3 DIMM s. ■ Do not mix: — DIMMs with different sizes or clock rates in a cha[...]
-
Page 63
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) SUPPLEMENTAL MATERIAL 63 Supported DIMM P opulations The supported DIMM populations are listed in Ta b l e 35 . T able 35 Supported DIMM Configur ations CPU 1 DIMMs T otal DIMMs for CPU 1 CPU 1 Capacity CPU 2 DIMMs To t a l D I M M s for CPU 2 CPU 2 Capacity T[...]
-
Page 64
Cisco UCS Cisco UCS C22 0 M3 High-Density Rac k Server (Small Form Factor Disk Drive Model) 64 SUPPLEMENTAL MATERI AL Low-V oltage DIMM Consider ations The C220 M3 server can be ordered with dual-volta ge (1.5/1.35 V) DIMMs o nly . Note the following consideratio ns: ■ Low-voltage DIMMs within the server must ha ve the identical manufacturer , ty[...]
-
Page 65
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) SUPPLEMENTAL MATERIAL 65 RAID Details The available RAID conf iguratio ns are shown in this section. (1) 1-CPU Configur ations Mezzanine cards are not supported for 1-CPU config urations, Therefore, only the following RAID controllers are supported for single-[...]
-
Page 66
Cisco UCS Cisco UCS C22 0 M3 High-Density Rac k Server (Small Form Factor Disk Drive Model) 66 SUPPLEMENTAL MATERI AL RAID Option ROM (OPROM) Settings The server contains an Option ROM (OPROM) for the PCIe slots. The server has a finite amount of option ROM with which it can boot up devices. Go into the BI OS and disa ble the O PROM on the PCIe slo[...]
-
Page 67
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) SUPPLEMENTAL MATERIAL 67 Serial P ort Details The pinout details o f the rear RJ-45 serial por t connector are shown in Figure 9 . Figure 9 Serial P ort (F emal e RJ-45 Connector) Pinout 1 2 3 4 5 6 7 8 Pin Serial P or t (RJ-45 F emale Connector) Signal RTS (R[...]
-
Page 68
Cisco UCS Cisco UCS C22 0 M3 High-Density Rac k Server (Small Form Factor Disk Drive Model) 68 SUPPLEMENTAL MATERI AL Upgr ade and Serv icing-Related P arts This section lists the upgrade and serv icing-related part s you may need during the life of your server . Some of these parts are configured with every server , and some may be ordered when ne[...]
-
Page 69
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) SUPPLEMENTAL MATERIAL 69 Drive Blanking P anels A drive blanking panel (N20-BBLKD=) must be instal led if you remove a disk drive from a UCS server . These panels are required to main tain system temperatures at safe operat ing levels, and to keep dust away fr[...]
-
Page 70
Cisco UCS Cisco UCS C22 0 M3 High-Density Rac k Server (Small Form Factor Disk Drive Model) 70 SUPPLEMENTAL MATERI AL http://www .cisco.com/en/US/docs/unified_computing/ucs/c/hw/C220/install/ replace.html#wp1233864 Thermal Grease (with syringe appl icator) for CPU to Heatsink Seal Thermal grease must be applied to the top of the CPU where it comes [...]
-
Page 71
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) SUPPLEMENTAL MATERIAL 71 RACKS The Cisco R42610 rack (see Figure 10 ) is certified for Cisco UCS insta llation at customer site s and is suitable for the following equipment: ■ Cisco UCS B-Series servers and fa bric interc onnects ■ Cisco UCS C-Series and [...]
-
Page 72
Cisco UCS Cisco UCS C22 0 M3 High-Density Rac k Server (Small Form Factor Disk Drive Model) 72 SUPPLEMENTAL MATERI AL Figure 10 Cisc o R42610 R ack Front view - door closed Front view - door open Front view - door removed[...]
-
Page 73
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) SUPPLEMENTAL MATERIAL 73 PDUs Cisco RP Series P ower Distribution Units (PDUs) offer power distribution with branch circuit protection. Cisco RP Series PDU models distri bute power to up to 24 outlets. The ar chitecture organize s power distribution, simplifie[...]
-
Page 74
Cisco UCS Cisco UCS C22 0 M3 High-Density Rac k Server (Small Form Factor Disk Drive Model) 74 SUPPLEMENTAL MATERI AL KVM CABLE The KVM cable provides a connection into the server , providing a DB9 serial connector , a VGA c onnector for a monitor , and dual USB ports for a keyboard and mo use. With this cable, you can create a direct connection to[...]
-
Page 75
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) SUPPLEMENTAL MATERIAL 75 Motherboard USB and SD P orts, and RAID Card Backup Location The C220 M3 SFF motherboard has a general-purpose USB socket, an d two SD so ckets as shown in Figure 13 . The mounting location for the RAID SuperCap da ta cache power backu[...]
-
Page 76
Cisco UCS Cisco UCS C22 0 M3 High-Density Rac k Server (Small Form Factor Disk Drive Model) 76 TECHNICAL SPECIFIC ATIONS TECHNICAL SPECIFICA TIONS Dimensions and Weight P ower Specifications The general power specifications for the C220 M3 SFF server 450 W (AC) power supply are l isted in Ta b l e 40 . T able 39 UCS C220 M3 Dimensions and We ight P[...]
-
Page 77
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) TECHNICAL SPECIFICATIONS 77 The general power specifications for the C220 M3 SFF server 650 W (AC) power supply are l isted in Ta b l e 41 . Po w e r s u p p l y o u t p u t v o l t a g e Main power: 12 VDC Standby power: 12 VDC P ower supply efficiency CSCI P[...]
-
Page 78
Cisco UCS Cisco UCS C22 0 M3 High-Density Rac k Server (Small Form Factor Disk Drive Model) 78 TECHNICAL SPECIFIC ATIONS The general power specifications for the C220 M3 SFF server 930 W (DC) power supply are listed in Ta b l e 42 For configuration-specif ic power specifications, use the Cisco UCS P ower Ca lculator at this URL: https://express.sal[...]
-
Page 79
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) TECHNICAL SPECIFICATIONS 79 Env ironmental Specifications The power specifications for the C220 M3 server are listed in Ta b l e 43 . T able 43 UCS C220 M3 Environmental Specifications Pa r a m e t e r Minimum T emperature operating 41 to 104° F (5 to 40 ° C[...]
-
Page 80
Cisco UCS Cisco UCS C22 0 M3 High-Density Rac k Server (Small Form Factor Disk Drive Model) 80 TECHNICAL SPECIFIC ATIONS Compliance Requirements The regulatory compliance requirements for C-Series servers are listed in Ta b l e 44 . T able 44 UCS C-Series Regul atory Compliance Requirements Pa r a m e t e r Description R egulatory Compliance P rodu[...]