Cleveland Range KDT-12-T manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Cleveland Range KDT-12-T, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Cleveland Range KDT-12-T one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Cleveland Range KDT-12-T. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Cleveland Range KDT-12-T should contain:
- informations concerning technical data of Cleveland Range KDT-12-T
- name of the manufacturer and a year of construction of the Cleveland Range KDT-12-T item
- rules of operation, control and maintenance of the Cleveland Range KDT-12-T item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Cleveland Range KDT-12-T alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Cleveland Range KDT-12-T, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Cleveland Range service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Cleveland Range KDT-12-T.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Cleveland Range KDT-12-T item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    SE95008 Rev . 3 Operators Manual Installation, Operation & Service Direct Steam T able T op Kettles T able-T op Direct Steam Kettles MODELS: KDT- 1 - T KDT- 3 - T KDT- 6 - T KDT-12 - T KDT-20 - T SD Stands MODELS: SD - 450 SD - 650 SD - 760 SD -1050 SD -1200 SD -1600 SD -1800 Kettles on SD Stands MODELS: SD - 450 - K 6 SD - 650 - K 12 SD - 760 [...]

  • Page 2

    T ABLE OF CONTENTS Installation General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Inspection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Shipping Damage Instruction . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Clearance Requir ements . . . . . .[...]

  • Page 3

    1 GENERAL Installation of the unit must be accomplished by qualified installation personnel working to all applicable local and national codes. Improper installation of product could cause injury or damage. This unit is built to comply with applicable standards for manufactur ers. Included among those approval agencies ar e: UL, NSF , ASME/Ntl.Bd.,[...]

  • Page 4

    2 STEAM All steam plumbing to and from the kettle and steam boiler should be thoroughly cleaned and inspected for dirt and debris before final connection to the kettle are made. Generally , kettles r equire 1/2" i.p.s. pipe, 10-45 psi steam pressur e. If the steam supply pressur e exceeds 45 psi, a pressur e reducing valve is requir ed. The st[...]

  • Page 5

    OPERA TION 1. Ensur e that ther e is an adequate steam supply to the kettle. 2. T urn the steam control valve to the open position by turning the knob counter -clockwise, then allow the kettle to preheat. NOTE: When cooking egg and milk products, the kettle should NOT be preheated, as pr oducts of this nature adher e to hot cooking sur faces. These[...]

  • Page 6

    4 CARE AND CLEANING Y our kettle must be cleaned r egularly to maintain its fast, efficient cooking performance, and to ensure its continued safe, r eliable operation. W ARNING: Do not use chloride base detergents. 1. Prepar e a war m water and mild detergent solution in the kettle. 2. Remove food soil inside the kettle using a nylon brush. Do not [...]

  • Page 7

    5 STEAM CONTROL ASSEMBL Y SER VICE P AR TS 1 15 16 2 3 4 5 5 22 6 7 8 9 10 1 13 14 21 20 19 18 17 25 4 23 24 12 4 5 3 21 20 19 18 17 5 6 7 8 9 4 23 7 8 9 23 6 7 8 9 4 23 13 12 5 26 28 7 8 23 30 27 29 11 1 5 4[...]

  • Page 8

    6 STEAM CONTROL ASSEMBL Y ITEM NO . P ART NO . DESCRIPTION QTY . 1. F A11056 Binding Head Screw , 6-32 x 1/2" lg. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 2. KE50458 End Cap, condensate return . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 3. KE50455-1 T runnion, condensate return . . . . .[...]

  • Page 9

    7 3 4 7 6 5 11 1 0 9 8 16 12 13 15 14 22 21 19 18 20 Se e S tea m Co ntr ol Dra wing 2 1 1 1 24 28 1 25 2 6 27 30 Se e S tea m Co ntr ol Dra wing 2 3 17 Steam In Configuration for SD Stand with Two Kettles 2 2 CONDENSATE CONDENSATE RETURN RETURN STEAM STEAM IN IN STEAM IN CONDENSATE RETURN Se e S tea m Co ntr ol Dra wing STEAM STEAM IN IN STEAM IN [...]

  • Page 10

    8 PLUMBING ASSEMBL Y (for SD Stands) ITEM NO . P ART NO . DESCRIPTION QTY . 1. FI00169 T ee, 1/2" NPT . (single kettle units) . . . . . . . . . . . . .1 (twin kettle units) . . . . . . . . . . . . . .3 2. KE51723 Pressur e Relief V alve, 1/2" NPT (single kettle units) . . . . . . . . . . . . .1 (twin kettle units) . . . . . . . . . . . . [...]

  • Page 11

    9 6 7 8 4 5 1 4 2 3 1 2 3 1 1 1 2 9 1 1 1 2 1 0 F AUCET ASSEMBLIES[...]

  • Page 12

    10 F AUCET ASSEMBLIES ITEM NO . P ART NO . DESCRIPTION QTY . 1. KE50825-8 6 gallon . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 KE50825-1 12 gallon . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 KE50825-1 20 gallon . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .[...]

  • Page 13

    PRESSURE RELIEF V AL VE TESTING PROCEDURE The pressur e relief valve (optional on kettles) must be checked at least twice a year as part of the normal maintenance per formed. 1. Open steam valve and preheat kettle. 2. Stand to the side of the pressur e relief valve discharge tube and pull ring three or four times to insure fr ee movement. Hold valv[...]

  • Page 14

    TROUBLESHOOTING GUIDE This section contains information intended for use by Authorized Service Personnel only . PROBLEM A / Kettle heats too slowly or does not come to a boil. Pr obable Cause Remedy 1. Inadequate steam flow . Check for correct steam using chart below . If kettle is connected to a steamer and power ed by a generator the units should[...]

  • Page 15

    9.88" 251mm 1/2" NPT STEAM INLET 1/2" NPT CONDENSATE RETURN 8.00" 203mm 9.38" 238mm 12.25" 311mm 12.50" 318mm 8.13" 207mm 9.31" 236mm 1.56" 40mm 3.50" 89mm 13 SPECIFICA TION DRA WINGS KDT -1-T CLEARANCE REQUIREMENTS TO COMBUSTIBLE AND NONCOMBUSTIBLE SURF A CES: Right - 4" Left - 0 Back - 0[...]

  • Page 16

    14 F G NOTE: INLET AND RETURN NOT INTERCHANGABLE C A B WALL E D H 1/2" NPT STEAM INLET 1/2" NPT CONDENSATE RETURN STEAM CONTROL VALVE K M L N J 1.00" 25mm 1.25"/32mm WALL 2.25" 57mm GAL. LITRE A B C D E F G H J K L M N 3 11 IN 14.00 10.00 15.13 12.50 8.25 10.00 12.50 23.00 7.00 4.00 11.00 15.00 21.00 mm 356 254 384 317 210 [...]

  • Page 17

    15 F G NOTE: INLET AND RETURN NOT INTERCHANGABLE C A B WALL E D 1/2" NPT STEAM INLET 1/2" NPT CONDENSATE RETURN K M J 1.75" 45mm WALL H STEAM CONTROL VALVE 1.25" 32mm 2.25" 57mm L MARINE LOCK GAL. LITRE A B C D E F G H J K L M 3 11 IN 20.50 16.75 23.00 22.25 13.50 19.50 22.00 29.00 6.00 8.75 11.50 29.50 mm 521 425 584 565 3[...]

  • Page 18

    SD ST ANDS WITH KETTLES CLEARANCE REQUIREMENTS TO COMBUSTIBLE AND NONCOMBUSTIBLE SURF A CES: Right - 0 Left - 0 Back - 0 MARINE LOCK SLIDING DRAIN PAN 18.00" 457mm 6.00" 152mm A 27.75" 706mm 22.00" 610mm 1.47" 37mm 1.47" 37mm H C 16.88" 429mm 13.75" 349mm 33.50" 851mm D 5.00" 127mm 3.25" 83mm B[...]