Dell T310 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Dell T310, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Dell T310 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Dell T310. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Dell T310 should contain:
- informations concerning technical data of Dell T310
- name of the manufacturer and a year of construction of the Dell T310 item
- rules of operation, control and maintenance of the Dell T310 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Dell T310 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Dell T310, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Dell service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Dell T310.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Dell T310 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Dell PowerEdge T 310 T echnical Guid e 0 DELL TM POWEREDGE™ T310 TECHNIC AL GUIDEB OOK[...]

  • Page 2

    Dell PowerEdge T 310 T echnical Guid e 1 White P aper’s Ti tle By (Author’s name) This document is for informational purposes only. Dell reserves the right to make changes without further notice to any products herein. The content provided is as is and without ex press or implied warranties of any kind. Dell, PowerEdge, and ReadyRails are trade[...]

  • Page 3

    Dell PowerEdge T 310 T echnical Guid e 2 Table of Cont ents 1 Overvie w ........................................................................................................................................... 6 1.1 Product Description ................................................................................................................[...]

  • Page 4

    Dell PowerEdge T 310 T echnical Guid e 3 5.5 Maximum Input Amps ............................................................................................................. 31 5.6 Energy Star Compliance ......................................................................................................... 31 6 Proc essors .......................[...]

  • Page 5

    Dell PowerEdge T 310 T echnical Guid e 4 16 Systems Man agement .................................................................................................................... 59 16.1 Overvie w ................................................................................................................................ . 59 16.2 Server Manag[...]

  • Page 6

    Dell PowerEdge T 310 T echnical Guid e 5 Figures Figure 1. PowerEdge T310 Dimensions 14 Figure 2. Front Panel Views and Features 15 Figure 3. Back Panel View and Features 16 Figure 4. Power Supply Indicators for Redundant PSU Only 17 Figure 5. NIC Indicators 17 Figure 6. Side View 19 Figure 7. Hot - Swap HDD Chassis 19 Figure 8. Cabled HDD Chassis [...]

  • Page 7

    Dell PowerEdge T 310 T echnical Guid e 6 1 Overview 1.1 Product Description Dell’s robust and reliable, 1- socket PowerEdge™ T310 tower server offers the performance of Intel ® processors, DDR3 memory, advanced systems management options and the availability of up to four hard drives (3.5” or 2.5”) in a compact tower chassis. The Del l Pow[...]

  • Page 8

    Dell PowerEdge T 310 T echnical Guid e 7 1.2 Product Comparison Table 1 shows a product comparison for the PowerEdge T310, PowerEdge T300, and PowerEdge T410 servers. Table 1. Comparison for PowerEdge Servers Feature/ Spec PowerEdge T310 PowerEdge T300 ( Pr edecessor ) PowerEdge T410 ( Next level up ) Processor Intel ® Xeon ® 3400 series Intel ®[...]

  • Page 9

    Dell PowerEdge T 310 T echnical Guid e 8 Feature/ Spec PowerEdge T310 PowerEdge T300 ( Pr edecessor ) PowerEdge T410 ( Next level up ) SAS 5/iR (For TBU) LSI2032 (For TBU) PERC H800 RAID: SAS 6/iR PERC S300 PERC 6/i PERC 6/E PERC H200 PERC H700 LSI2032 (For TBU) RAID: SAS 5/E SAS 6/iR PERC 6/i PERC 6/E LSI 2032 (For TB U only) SAS 6/E RAID: SAS 6/i[...]

  • Page 10

    Dell PowerEdge T 310 T echnical Guid e 9 Feature/ Spec PowerEdge T310 PowerEdge T300 ( Pr edecessor ) PowerEdge T410 ( Next level up ) (SATA & SAS) SAS 6i/R: RAID 0, 1 (SATA & SAS) PERC 6/i: RAID 0, 1, 5, 6, 10 (SATA, SAS & SSD) PERC H200: RAID 0, 1, 10 (SATA, SAS & SSD) PERC H700: RAID 0, 1, 5, 6, 10 (SATA, SAS & SSD) NIC/LOM 2[...]

  • Page 11

    Dell PowerEdge T 310 T echnical Guid e 10 2 New T echnologies 2.1 Overview A number of new technologies are used in the PowerEdge T310, including: • New Intel 1 -S ocket platform ( Xeon 3400 series processor /Intel desktop processor + Intel 3420 chipset ) • Intel desktop processor s: • Intel Core i3 540 3.06GHz/2C/4M • Intel Core i3 530 2.9[...]

  • Page 12

    Dell PowerEdge T 310 T echnical Guid e 11 2.2.3 Software RAID Dell Software RAID is a chipset RAID - enhanced version based on Intel chipset 3420. PERC S100 is purely a chipset firmware/driver upgrade. PERC S300 contains the same chipset firmwar e/driver upgrade as the PERC S100 and, in addition, adds a RAID chip on the card . While both the PERC S[...]

  • Page 13

    Dell PowerEdge T 310 T echnical Guid e 12 3 Systems Overview Table 2. Product Features Summary FEATURES PowerEdge T310 Form Factor Tower Processors One Quad - core Int el ® Xeon ® 34 00 series process ors One Dual - core Intel ® Core i3 540 , Intel ® Core i3 530 , Intel ® Pentium ® G6950 or, Intel ® Celeron ® G1101 Processor Sockets 1 Front[...]

  • Page 14

    Dell PowerEdge T 310 T echnical Guid e 13 2.5” SAS (10K RP M ): 146 GB or 300GB 2.5” SATA SSD 25GB, 50GB Network Inter fac e Cards Broadcom ® NetXtreme™ 5709 Dual P ort Gigabit Ether net NIC, Copper, w/TOE P CIe x4 Broadcom ® Net X treme™ 5709 Dual Port Gigabit Ethernet NIC, Copper, TOE/iSC SI PCIe x4 Intel ® PRO/1000 PT Singl e Port Ada[...]

  • Page 15

    Dell PowerEdge T 310 T echnical Guid e 14 4 Mechanical 4.1 Chassis Description The PowerEdge T310 chassis design provides capability for hardware redundancy . This new chassis design offers cabled HDD with flexible PSU (redundant PSU or non - redundant PSU) and Hot - Plug HDD with flexible PSU (redundant PSU or non - redundant PSU). Various configu[...]

  • Page 16

    Dell PowerEdge T 310 T echnical Guid e 15 4.3 Front Panel View and Features Figure 2. Front Panel Views and Features[...]

  • Page 17

    Dell PowerEdge T 310 T echnical Guid e 16 4.4 Back Panel View and Features Figure 3. Back Panel View and Features[...]

  • Page 18

    Dell PowerEdge T 310 T echnical Guid e 17 4.5 Power Supply Indicators Figure 4. Power Supply Indicators for Redundant PSU Only Not lit — AC power is not connected. Green — In standby mode, a green light indicates that a valid AC source is connected to the power supply and that the power s upply is operational. When the system is on, a green lig[...]

  • Page 19

    Dell PowerEdge T 310 T echnical Guid e 18 Table 4. NIC LED Activity State LINK LED (Green/Yellow) ACTIVITY LED (Green) No link Off Off D0 initialized (Out of box), D3 cold, S4 (Hibernation) Wake on LAN ( WOL ) disabled Off Off WOL enabled, Link, No Activity Green if the port is operating at maximum port speed; Yellow otherwise Off WOL enabled, Link[...]

  • Page 20

    Dell PowerEdge T 310 T echnical Guid e 19 4.7 Side View Figure 6. Side View 4.8 Internal Chassis Views Figure 7. Hot - Swap HDD C hassis[...]

  • Page 21

    Dell PowerEdge T 310 T echnical Guid e 20 Figure 8. Cabled HDD Chassis 4.9 Fan There is one system fan located at rear of the system. Figure 9. Rear and Internal Views of Fan[...]

  • Page 22

    Dell PowerEdge T 310 T echnical Guid e 21 4.10 Control Panel/ LCD Front control panel features include: • 2x USB • Diagnostic indicator (11G LCD module) • NM I button • Power button • HDD activity LED • System ID button For information on LCD panel features, see the Hardware Owner’s Manual . Figure 10. LCD -F ront P anel ( H ot -S wap[...]

  • Page 23

    Dell PowerEdge T 310 T echnical Guid e 22 4.11 Security 4.11.1 Cover L atch The system coin lock located on the front of the right side cover prov ides security for the entire system, with tool - less operation for opening and closing the cover . Figure 12. System Coin Lock under Cover L atch The bezel lock secures both the bezel and cover latch. F[...]

  • Page 24

    Dell PowerEdge T 310 T echnical Guid e 23 Figure 14. L ock Port on Back of Chassis A lock port located on the back of the chassis provides s ecur ity for the entire system . 4.11.2 Bezel Keys for the PowerEdge T310 are stored on the inside of the bezel. Figure 15. Bezel and Key Storage 4.11.3 Hard Drive Access Hot - Plug h ard drives are only acces[...]

  • Page 25

    Dell PowerEdge T 310 T echnical Guid e 24 4.11.4 Trusted Platform Mod ul e (TPM) TPM is available worldwide with the exception of China, where Trusted Computing Model ( TCM ) is the standard. The PowerEdge T310 offers a TPM 1.2 compliant encryption chip solution on system board w ith BIOS support . TPM 1.2 c hip was validated/supported with Windows[...]

  • Page 26

    Dell PowerEdge T 310 T echnical Guid e 25 Figure 17. Internal USB Connectors 4.13 Battery Battery placement on the motherboard is shown in Figure 18, and the batter y holder for the PERC card is shown in Figure 19 . Figure 18. Motherboard B attery ( CR2032 )[...]

  • Page 27

    Dell PowerEdge T 310 T echnical Guid e 26 Figure 19. Battery Holder for PERC Card: L ocated Under the HDD C age 4.14 Field Replaceable Units (FRU) Parts available for field replacement include: • Motherboard • Backplane • Power Distribution board • Processor • Controller Card (SAS card, PERC card ) • Power Source 4.15 User Accessible Ju[...]

  • Page 28

    Dell PowerEdge T 310 T echnical Guid e 27 5 Power , Thermal, Acoustic 5.1 Power Supplies The base system include s one 375W power supply. This unit provide s power to the PowerEdge T310 planar, four internal hard drive bays, and two 5.25” ex ternal drive bays. Power is “soft - switched” ( allowing power cycling through a switch on the front o[...]

  • Page 29

    Dell PowerEdge T 310 T echnical Guid e 28 Table 5. Environmental Specifications and Operating Requirements Environment Oper at ing Requirement s Non - Operating Requirements Temperature Range s (For Altitude ≤900 m or 2952.75 ft) 10 t o 35 °C (50 to 95 °F) - 40 to 65 °C (- 40 to 149 °F) Temperature Range s (For Altitude > 900 m o r 2952.75[...]

  • Page 30

    Dell PowerEdge T 310 T echnical Guid e 29 5.3 Acoustics The acoustical design of the PowerEdge T310 reflects the following: • Adherence to Dell’s high sound quality standards. Sound quality is different from sound power level and sound pressure level in that it describes how humans respond to annoyances in sound, like whistles, hums, etc. One o[...]

  • Page 31

    Dell PowerEdge T 310 T echnical Guid e 30 Table 6. Acoustical Specifications Standby: AC Power is co nnected to Power Su ppl y Units but system is not turned on. Definitions Idle: Reference ISO7779 ( 1999) definition 3.1. 7; system is runnin g in its OS but no other specific activity. Stressed Process or: An operating m ode per ISO7779 (1999 ) defi[...]

  • Page 32

    Dell PowerEdge T 310 T echnical Guid e 31 5.4 Other E nvironment al Requirements 5.4.1 Maximum V ibration Operating : 0.26 G at 5 – 500 Hz for 15 min Storage : 1.54 G at 10 – 250 Hz for 15 min 5.4.2 Maximum S hock Operating: One shock pulse in the positive z axis (one pulse on each side of the system) of 31 G for 2.6 ms in the operational orien[...]

  • Page 33

    Dell PowerEdge T 310 T echnical Guid e 32 6 Processors Processors supported on the PowerEdge T310 server are shown in Table 7 . Table 7. Supported Processors Model Speed Pow er Cache Cores Threads Turbo Memory Process X3470 2.93G Hz 95W 8M 4 8 T DDR3 1333 45nm X3460 2.80G Hz 95W 8M 4 8 T DDR3 1333 45nm X3450 2.67G Hz 95W 8M 4 8 T DDR3 1333 45nm X34[...]

  • Page 34

    Dell PowerEdge T 310 T echnical Guid e 33 7 Memory 7.1 Overview The PowerEdge T310 planar provide s six 72 - bit (240 - pin) sockets for DIMM memory modules. These modules are DDR 3- 800/1066/1333 Register ed/Unbuffered DDR SDRAM DIMMs. The modules are configured as 72 bits wide to provide for error- correcting code ( ECC ) . The memory controller [...]

  • Page 35

    Dell PowerEdge T 310 T echnical Guid e 34 Table 8. Memory Support : U- DIMM U- DIMM DDR3 ECC System Capaci ty DIMM Speed DIMM Capacity # of DIMMs System Speed 1G 1066 1G x1 1066 1G 1333 1G x1 1333 2G 1066 1G x2 1066 2G 1333 1G x2 1333 4G 1066 2G x2 1066 4G 1333 2G x2 1333 4G 1066 1G x4 1066 4G 1333 1G x4 1333 8G 1066 2G x4 1066 8G 1333 2G x4 1333 8[...]

  • Page 36

    Dell PowerEdge T 310 T echnical Guid e 35 Table 9. Memory Support: R - DIMM R- DIMM DDR3 ECC System Capacity DIMM Speed DIMM Capacity # of DIMMs System Speed 1G 1066 1G x1 1066 1G 1333 1G x1 1333 2G 1066 1G x2 1066 2G 1333 1G x2 1333 2G 1066 2G x1 1066 2G 1333 2G x1 1333 4G 1066 2G x2 1066 4G 1333 2G x2 1333 4G 1066 1G x4 1066 4G 1333 1G x4 1333 6G[...]

  • Page 37

    Dell PowerEdge T 310 T echnical Guid e 36 Figure 20. Slots and Risers 7.4 Speed The PowerEdge T310 supports up to 4 UDIMMs (unbuffered DDR3 ECC) as shown in Table 10 and Table 11 . Table 10. 4 DIMM Information DIMM Slots per Channel DIMMs Populated per Channel POR Speeds Ranks per DIMM 2 1 1066,1333 SR, DR 2 1 1066,1033 SR, DR Table 11. 4 DIMM MAX [...]

  • Page 38

    Dell PowerEdge T 310 T echnical Guid e 37 Notes • T310 supports x8 (data width) and does not support x4 DRAM on UDIMM • T310 does not support Quad Rank UDIMM • All channels in a system will run at the fastest common frequency • No mixing of registered and unbuffered DIMMs • Non - ECC UDIMMs are not supported on T310 • Mixing ECC and non[...]

  • Page 39

    Dell PowerEdge T 310 T echnical Guid e 38 7.5 Sparing Not supported. 7.6 Mirroring Not supported. 7.7 RAID The PowerEdge T310 has no specific memory rules in supporting RAID. 7.8 Supported Configurations Table 14. Supported Memory Configurations System Capacity System Me mo ry Speed DIMM TYPE DIMM Capacity NUM DIMM 1 GB 1066 U 1GB 1 1 GB 1333 U 1GB[...]

  • Page 40

    Dell PowerEdge T 310 T echnical Guid e 39 System Capacity System Me mo ry Speed DIMM TYPE DIMM Capacity NUM DIMM 8 GB 1333 U 4GB 2 8 GB 1066 U 2GB 4 8 GB 1333 U 2GB 4 8 GB 1066 R 2GB 4 8 GB 1066 R 4GB 2 8 GB 1333 R 2GB 4 12GB 800 R 2GB 6 12GB 800 R 2GB 6 16 GB 1066 U 4GB 4 16 GB 1333 U 4GB 4 16 GB 800 R 4GB 4 32 GB 800 R 8GB 4 DT processor supports[...]

  • Page 41

    Dell PowerEdge T 310 T echnical Guid e 40 8 Chipset 8.1 Overview The PowerE dgeT310 planar incorporates the Intel 3420 chipset and the Intel 3420 or Platform Controller Hub (PCH) , a highly integrated I/O controller. A number of high - level features are supported by the chipset on PowerEdge T310, as detailed in the following sections. 8.2 Direct M[...]

  • Page 42

    Dell PowerEdge T 310 T echnical Guid e 41 8.7 PCI Inte rface The Intel 3420 PCI interface provides a 33 MHz, Revision 2.3 implementation. The Intel 3420 integrates a PCI arbiter that supports up to four external PCI bus masters in additi on to the internal Intel 3420 requests. This allows for combinations of up to four PCI down devices and PCI slot[...]

  • Page 43

    Dell PowerEdge T 310 T echnical Guid e 42 8.12 Universal S erial B us (USB) Controller s The Intel 3420 contains up to two Enhanced Host Controller Interface (EH CI) host controllers that support USB high - speed signaling. High - speed USB 2.0 allows data transfers up to 480 Mb/s. The PCH also contains two Rate Matching Hubs (RMH) that support USB[...]

  • Page 44

    Dell PowerEdge T 310 T echnical Guid e 43 • Intruder Detect. The Intel 3420 provides an input signal (INTRUDER#) that can be attached to a switch that is activated by the system case being opened. The Intel 3420 can be pro grammed to generate an SMI# or TCO interrupt due to an active INTRUDER# sig nal. 8.17 Sy stem Management Bus (SMBus 2.0) The [...]

  • Page 45

    Dell PowerEdge T 310 T echnical Guid e 44 9 BIOS 9.1 Overview The T310 BIOS is based on the Dell BIOS core, and supports the following features: • 1S Support • Simultaneous Multi - Threading (SMT) support • CPU Turbo Mode support • PCI 2.3 compliant • Plug n’ Play 1.0a compliant • MP (Multiprocessor) 1.4 compliant • Boot from hard d[...]

  • Page 46

    Dell PowerEdge T 310 T echnical Guid e 45 9.3 Power Management Power management features come in two flavors: fixed or generic . Fixed features u se bits defined in the ACPI specification for specific capabilities. The fixed feature bits give the O S complete control over the power management of a device since the location of the bits is given to t[...]

  • Page 47

    Dell PowerEdge T 310 T echnical Guid e 46 Feature Type Enable/Status/ Ctrl bit location Description Power Profile support N/A Processor/ IMC and PCH chipset registers. 11G Servers will be the m ost energy smart servers that D ell will ship. In addi tion to P, C, and T state s, BIOS will expos e the Power Profiles to the OS. Each Power profile will [...]

  • Page 48

    Dell PowerEdge T 310 T echnical Guid e 47 10 I/O Slots 10.1 Overview Table 18. PCIe Slot S pecification All slots are full height and half length. Slot Slot Connector Routing Lanes Technology Silkscreen 1 X8 X8 PCIe 2.0 (5GT/s) SLOT1 PCIE_G2_x8 2 X16 X8 PCIe 2.0 (5GT/s) SLOT2 PCIE_G2_x8 3 X8 X4 PCIe 2.0 (2.5GT/s) SLOT3 PCIE_G2_x4 4 X1 X1 PCIe 2.0 ([...]

  • Page 49

    Dell PowerEdge T 310 T echnical Guid e 48 Table 19. Quantities and Priorities Category Description Bandwidth Max Qty Slot Priority Internal Controllers (Only one internal controller can be installed in a T310 system.) PERC H700 x8 1 Slot 1 PERC H700 NV ( available Mar ch 2010) x8 1 Slot 1 PERC 6/I Adapter x8 1 Slot 1 PERC H200 x8 1 Slot 1,2 SAS 6/i[...]

  • Page 50

    Dell PowerEdge T 310 T echnical Guid e 49 Notes • RBOD is RAID Bunch of Disks • The cards must be installed in the order they are listed (top to bottom) • If multiple adapter part numbers are on one line, install in order shown • The adapter should be installed by Slot Priority in the first available slot (L to R ) • Placement of card(s) [...]

  • Page 51

    Dell PowerEdge T 310 T echnical Guid e 50 11 Storage 11.1 Overview T3 10 supports up to 4 HDD s , using one of the following options: • 4x 3.5 ” cabled SATA from motherboard SATA connector • 4 x 3.5 ” cabled SAS or SATA via add - on storage controller • 4 x 3.5 ” hot - swap SAS or SATA via add- on storage controller • 4 x 2.5 ” hot [...]

  • Page 52

    Dell PowerEdge T 310 T echnical Guid e 51 11.3 RAID Configurations Table 23. Raid Configurations Cabled / Hot Sw ap Config Typ e Configs Description Min HDD Max HDD Cabled NO HDD C0A NCZCBL No HD D, Cabled HDD Chassis 0 0 Hot - Swap NO HDD C0B NCZ No HDD, Hot - Swap HDD Chas sis (SAS 6/iR, H200, PERC 6/I or H700) 0 0 Cabled Embedd e d SATA - NO RAI[...]

  • Page 53

    Dell PowerEdge T 310 T echnical Guid e 52 Cabled / Hot Sw ap Config Typ e Configs Description Min HDD Max HDD RAID (SAS 6/iR or H200) Cabled SAS/SAT A – RAID0 C9 ASSR0C BL Add - in SAS/SATA RAID card, RAID 0 2 4 (SAS 6/iR, H200, PERC 6/i, or H700) Cabled SAS/SAT A – RAID1 C10 ASSR1C BL Add - in SAS/SATA RAID card, RAID 1 2 2 (SAS 6/iR, H200, PE[...]

  • Page 54

    Dell PowerEdge T 310 T echnical Guid e 53 11.3.1 Back- Up D rives (Tape) Tape drives are optional and connect to the planar via SATA/SCSI controller card/SAS controller card. IDE tape drive is no longer supported. The following tape drives are av ailable for usage on the PowerEdge T710: • I nter nal SATA, SCSI, and SAS drive s • External SCSI a[...]

  • Page 55

    Dell PowerEdge T 310 T echnical Guid e 54 12 Vi de o Matrox G200eW w/ 8MB memory integrated in Nuvoton ® WPCM450 (BMC controller) is included with the PowerEdge T310. Features include: • 1280x1024@85Hz for KVM and 1600x1200@60Hz for video out • 640x480 (60/72/75/85 Hz; 8/16/32 - bit color) • 800x600 (60/72/75/85 Hz; 8/16/32 - bit color) • [...]

  • Page 56

    Dell PowerEdge T 310 T echnical Guid e 55 13 Rack Information Dell does not provide a rack for the T3 10. However, there are 3 rd party trays available.[...]

  • Page 57

    Dell PowerEdge T 310 T echnical Guid e 56 14 Operating Systems Table 25. Microsoft OS Support Operating Systems x86 or x6 4 Installation Factory Install Logo/ Cert Windows ® Small Business Serv er 2008 x64 Standard FI N/A Premium FI or DIB Windows ® Essential Business Serv er 2008 x64 Standard, x64 DIB N/A Premium (4 th Server) x86 or x64 Windows[...]

  • Page 58

    Dell PowerEdge T 310 T echnical Guid e 57 Table 26. Linux OS Support Operating S ystems Installation Factory Instal l Logo/ Certificatio n Red Hat ® Enterp rise Linux ® 4.8 ES AP x86 -64 DIB, NFI Yes ES AP x86 DIB, NFI Yes Red Hat ® Enterp rise Linux ® 5.3 x86 -64 FI Yes x86 DIB, NFI Yes SLES11 X86-64 FI Yes SLES10 SP3 x86 -64 DIB, NFI Yes[...]

  • Page 59

    Dell PowerEdge T 310 T echnical Guid e 58 15 V irtualization Table 27. Supported Virtualization OS PowerEdge T310 VMWare ESX 4.0.1 Supported ; offered by drop - in - the - box (DIB); no factory install VMWare ESXi 4.0.1 Supported ; not offered through Dell (No FI nor DIB) VMWare ESX 3.5.1 Supported ; not offered through Dell (No FI nor DIB) VMWare [...]

  • Page 60

    Dell PowerEdge T 310 T echnical Guid e 59 16 Systems Managemen t 16.1 Overview Dell delivers open, flexible, and integrated solutions that help you reduce the complex ity of managing disparate IT assets by building comprehensive IT management solutions. Combining Dell PowerEdge Servers with a wide selection of Dell - developed management solutions [...]

  • Page 61

    Dell PowerEdge T 310 T echnical Guid e 60 16.3 Embedded Server Management The PowerEdge T310 implements circuitry for the next generation of Embedded Server Managem ent. It is Intelligent Platform Management Interface (IPMI) v2.0 compliant. The optional iDRAC (Integrated D ell Remote Access Controller) is responsible for acting as an interface betw[...]

  • Page 62

    Dell PowerEdge T 310 T echnical Guid e 61 16.5 iDRAC6 Express The optional iDRAC6 Express is the first tier of iDRAC 6 upgrades. In addition to upgrading the system with a Lifecycle Controller, the iDRAC6 Express offers the following key features: • Graphical web interface • Standard - based interfaces • Server Sensor monitoring and fault ale[...]

  • Page 63

    Dell PowerEdge T 310 T echnical Guid e 62 Feature BMC iDRAC 6 Expr ess iDRAC6 Enterprise v Flash Media Dynamic DNS     Dedicated NIC   Security and Authenticati on Role - based Authority     Local Users     Active Dire ct ory    SSL Encryption    Remote Managemen t and Remediatio n Remote [...]

  • Page 64

    Dell PowerEdge T 310 T echnical Guid e 63 17 Peripherals 17.1 USB P eripherals Optional USB 1.44MB floppy drive Optional USB DVD - ROM Optional internal USB 17.2 External Storage The following ex t ernal storage options a re available: • PV NAX o PV NX1950 • PV DAS o MD1000 JBOD o MD3000 RBOD o MD1120 JBOD • PV SAN o MD3000i iSCSI RAID array[...]

  • Page 65

    Dell PowerEdge T 310 T echnical Guid e 64 18 Packaging Options PowerEdge T310 is single pack only. Table 30. Dimensions and Weight INSIDE DIMENSIONS OUTSIDE DIMENSIONS WEIGHT Length: 74.6 cm (29.38” ) Width: 60.3 cm (23.75”) Depth: 42.2c m (16.63”) Length: 76.2cm (30.0” ) Width: 61.9 cm (24.38”) Depth: 45.4c m (17.88”) System packed out[...]

  • Page 66

    Dell PowerEdge T 310 T echnical Guid e 65 Appendix A. Regulatory Cert ifications The PowerEdge T3 10 meets the requirements outlined in the EMC, Product Safety and Environmental parts of Dell Compliance Design Standard (Dell P/N: ENG0002520). Regulatory M o del: E09S Regulatory T ype: E09S001 Product Safety, EMC and Environmental Da t asheet are av[...]

  • Page 67

    Dell PowerEdge T 310 T echnical Guid e 66 Appendix B. PowerEdge T 3 10 V ola ti lity T ables The tables that follow provide detailed information regardin g PowerEdge T310 volatility. Table 31. PowerEdge T3 10 Volatility Non - Volatile Volatile RAM Reference Designator Q t y Size Type Planar System BIOS SPI Flash Y U15 1 4MB Flash EEPROM (SPI interf[...]

  • Page 68

    Dell PowerEdge T 310 T echnical Guid e 67 Non - Volatile Volatile RAM Reference Designator Q t y Size Type Truste d Platform Module Y N U_TPM 1 128 bytes EEPROM Chipset CMOS Y U_IBX 1 256B Battery - backed RAM 2.5” Backplane or 3.5" Backplane Storage Controller Processor Y U_SEP 1 32KB Embedded Microcontroller Flash Control Panel Internal US[...]

  • Page 69

    Dell PowerEdge T 310 T echnical Guid e 68 Table 32. Volatility: Data Writing and Purpose Can user programs or operating system w rite data to it during normal operation? Purpose? Planar System BIOS SPI Flash No Boot Code, Sy stem Configuration Inf o rmation, EUFI environment LOM Configuration Data No LAN on Motherboar d configuration and f irmware [...]

  • Page 70

    Dell PowerEdge T 310 T echnical Guid e 69 Can user program s or operating syst em write data to it during normal oper ation? Purpos e? 2.5” Backplane or 3.5" Backplane Storage Controller Processor No Backplane firmware ( HD D status, etc.) Control Panel Internal USB Yes as al l ow ed by OS Normal usage is rea d only software lice nse key, bu[...]

  • Page 71

    Dell PowerEdge T 310 T echnical Guid e 70 How is data input t o t his memory? iDRAC6 Express Internal Flash iDRA C OS: Loading flash m em ory requires a vendor - prov ided firmware f i l e and loader program which i s ex ec uted by booting up t he system from a floppy or OS - based executable containi n g the firmware file and t he loader. System l[...]

  • Page 72

    Dell PowerEdge T 310 T echnical Guid e 71 How is data input t o t his memory? Power Supply PSU Microcontroller Loading flash m em ory re quires a vendor - provi de d firmware file an d loader program whic h is executed by booting u p the system from a f loppy or OS - based executabl e ( Unified Server Configurator) cont ai ning the firmwa re f ile [...]

  • Page 73

    Dell PowerEdge T 310 T echnical Guid e 72 How is this memory w ri t e protected? How i s t he memory clear e d? TPM Binding EEPROM (on China planar only) Locked by BIOS from physical access by anyone after boot N/A - BIOS control only iDRAC6 SDR AM n/a AC cycle for BMC OS and reset / power off server for VGA frame buffer iDRAC6 FRU writes controlle[...]