Go to page of
Similar user manuals
-
Plumbing Product
Delta Dryden 75118
4 pages 0.23 mb -
Plumbing Product
Delta 142913
1 pages 0.1 mb -
Plumbing Product
Delta T17285
1 pages 0.46 mb -
Plumbing Product
Delta RP20049
6 pages 0.44 mb -
Plumbing Product
Delta 319-DST
12 pages 2.03 mb -
Plumbing Product
Delta 103
40 pages 3.49 mb -
Plumbing Product
Delta T14285-H2O
1 pages 0.85 mb -
Plumbing Product
Delta D2501 Series
8 pages 0.6 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Delta 4540 Series, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Delta 4540 Series one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Delta 4540 Series. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Delta 4540 Series should contain:
- informations concerning technical data of Delta 4540 Series
- name of the manufacturer and a year of construction of the Delta 4540 Series item
- rules of operation, control and maintenance of the Delta 4540 Series item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Delta 4540 Series alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Delta 4540 Series, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Delta service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Delta 4540 Series.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Delta 4540 Series item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
TWO HANDLE MINI-WIDESPREAD LA V A T OR Y F A UCETS LLA VES DE LA V AMANOS DE DOS MANIJ AS DE MINI-EXTENSIÓN R OBINETS DE STYLE “À ENTRAXE LONG” À DEUX POIGNÉES POUR LA V ABO ST AND ARD 1 ® U P C Write purchased model number here. Escriba aquí el número del modelo comprado. Inscrivez le numér o de modèle ici. Models/Modelos/Modèles 454[...]
-
Page 2
CLEANING AND CARE Care should be given to the cleaning of this product. Although its finish is extremely durable, it can be damaged by harsh abrasives or polish. T o clean, simply wipe gently with a damp cloth and blot dry with a soft towel. All par ts and finishes of the Delta ® faucet are warranted to the original consumer purchaser to be free f[...]
-
Page 3
Contact your distributor f or handle and accent options/finishes. Comuníquese con su distr ib uidor para obtener opciones en el tipo de manija y detalles (acentos)/ acabados. P our obtenir des renseignements sur les poignées, les garnitures et les finis livrables, veuillez communiquer avec votre distributeur . RP26533 ▲ Metal Pop-Up Assembly Le[...]
-
Page 4
4 53907 Rev . A RP24097 1/4 T urn Stop P arada (T ope) a un 1/4 de Rotación Butée 1/4 de tour RP4993 Seats & Springs Asientos y Resortes Sièges et ressorts RP42590 ▲ Handle Base, Snap Ring & Gasket Base de la Manija, Aro de Resorte y Empaque Embase de poignée, segment d’arrêt et joint RP26148 Bonnet Nuts Bonetes/Capuchones Chapeaux[...]
-
Page 5
FRONT FRON T FRONT T Inser t body (1) through sink and snap into place using plastic "umbrella" (2). NO TE: The front of the valve is labeled (3). Install gasket (1), base (2), and snap ring (3) over each end valv e (4). Be sure snap ring is fully seated in groove (5). B. A. 1 Remov e "umbrella" (1) and be sure snap rings seat i[...]
-
Page 6
2 T o install the handles (1): be sure glide ring (2) is properly seated in bottom of handle bef ore installing. Thread stem extender (3) into valv e stem (4). Place handle base (1) o ver stem extender and secure with set screw (5). Thread handle blade (6) onto the e xposed por tion of the set scre w . E. E. 1 2 3 1/2" (12.7mm) IPS Choose hook[...]
-
Page 7
Remov e stopper (1) and flange (2). Screw nut (1) all the wa y down. Push washer (2) and gask et (3) down. Remov e tailpiece (1) from body (2), add T eflon ® tape (3), replace tailpiece. C. B. A. 3 Apply silicone to underside of flange (1). Inser t body (2) into sink. Screw flange (1) into body (2). Pivot (1) must face f aucet. Pull assembly (2) d[...]
-
Page 8
Maintenance If faucet leaks from spout outlet–Shut off water supplies– Replace Seats and Spr ings (1).* If leak persists–Shut off water supplies–Replace Stem Unit Assemb ly (2).* Quite el aireador (1) y gire las manijas de la llav e (2) comple- tamente a la posición abier ta. Abra los suministros de agua caliente y fría (3) y deje que el [...]