Go to page of
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Delta VFB080D4H1, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Delta VFB080D4H1 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Delta VFB080D4H1. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Delta VFB080D4H1 should contain:
- informations concerning technical data of Delta VFB080D4H1
- name of the manufacturer and a year of construction of the Delta VFB080D4H1 item
- rules of operation, control and maintenance of the Delta VFB080D4H1 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Delta VFB080D4H1 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Delta VFB080D4H1, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Delta service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Delta VFB080D4H1.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Delta VFB080D4H1 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
READ AND SA VE THESE INSTRUCTIONS Address: 4405 Cushing Parkway , Fremont, CA 94538 US T oll Free Number: 1-888-979-9889 T ABLE OF CONTENTS Package Contents 2 General Safety Information 3 Preparation and Wiring Diagrams 4 Assembly Instructions - New Construction 5 Assembly Instructions - Existing Construction 6 Grille Installation 8 Humidity Sensin[...]
-
Page 2
2 Model : VFB 080D4H 1 1 6 2 3 4 5 P ART DESCRIPTION QTY Fan Body 1 Grille 1 Suspension Bracket I 1 Suspension Bracket II 1 Suspension Bracket III 1 Duct Connector 1 P ACKAGE CONTENTS A B HARDW ARE CONTENTS (Images are to scale) X 4 X 3 Long Wood Screw ( 4 x 25) Short Machine Screw (M4 x 12) 1 2 3 4 5 6[...]
-
Page 3
3 Model : VFB 080D4H 1 READ AND SA VE THESE INSTRUCTIONS GENERAL SAFETY INFORMA TION 1. Make sure that the electric service supply voltage is AC 120V , 60Hz. 2. Follow all local electrical and safety codes, as well as the National Electrical Code (NEC) and the Occupational Safety and Health Act (OSH Act). 3. Always disconnect the power source befor[...]
-
Page 4
4 Model : VFB 080D4H 1 PREP ARA TION T ool s Required f or A ssembly (no t included) : Hamme r , Flathead S cre wd ri ve r , Wi r e Nut s , Nails, Du ct T a p e, Phillips Head Screwdriver , Utility Knife Helpful T ools (not included): Electric Drill, Drill Bits W ARNING: T urn off electricity at breaker box before beginning installation. Carefully [...]
-
Page 5
5 Model : VFB 080D4H 1 ASSEMBL Y INSTRUCTIONS BEFORE INST ALLA TION T urn off power source. Review all safety precautions. 1. If spacing between joists is 12 in. apart, use four long wood screws (provided) to attach the fan body to ceiling joists. Hardware A Long wood screw 2. For joist spacing 16 in. - 24in., insert suspension bracket I into the b[...]
-
Page 6
6 Model : VFB 080D4H 1 ASSEMBL Y INSTRUCTIONS 5. Remove the fan junction box cover a . Using wire nuts (not supplied), connect house wires to fan wires b as shown in the wiring diagram on page 4. Wire connections are as follows: black to live switch wire, white to neutral, green to ground. Reattach fan junction box cover c . 6. Connect a 4 in. circ[...]
-
Page 7
1 7 Model : VFB 080D4H 1 ASSEMBL Y INSTRUCTIONS 3. If this fan is not replacing an old fan, be sure to cut a 10.25 in. x 10.25 in. opening for the fan body . 4. Place the duct connector through the ceiling cut out. Connect a 4 in. circular duct (not supplied) a and vent to the outside. Secure it with duct tape (not supplied) or clamp (not supplied)[...]
-
Page 8
8 Model : VFB 080D4H 1 GRILLE INST ALLA TION HUMIDITY SENSING F AN OPERA TION Attach grille by pinching mounting springs a and insert into the narrow rectangular slots in fan body . 1. Humidity Sensing Mode: Flip wall switch to “ON” position. The LED indicator light in the fan will be BLUE. The fan will automatically start when the humidity lev[...]
-
Page 9
9 Model : VFB 080D4H 1 See safety information before proceeding. Routine maintenance should be done at least once a year . • Never use solvents, thinner or harsh chemicals when cleaning the fan. • Do not allow water to enter the motor . • Do not immerse metal parts in water . • Do not immerse resin parts in water over 140º Fahrenheit. T ur[...]
-
Page 10
10 Model : VFB 080D4H 1 TROUBLESHOOTING PROBLEM POSSIBLE CAUSE CORRECTIVE ACTION The fan is not turning on 1. Power off 2. Faulty switch 3. Faulty wire connection 1. Make sure power supply is on. 2. T est or replace switch. 3. Check wire in switch box. The fan seems louder than it should 1. CFM too great 2. Damper not working properly or damaged 3.[...]
-
Page 11
1 1 Model : VFB 080D4H 1 DIMENSIONS PRODUCT SPECIFICA TIONS SPECIFICA TIONS Model No. VFB080D4H1 80 CFM Noise ≤ 0.3 Sones V oltage 1 10-220V Hertz 50-60Hz Power Consumption 9.0 W Duct diameter 4 in. Weight 7.52 lbs. Dimension Ceiling opening – length 10.25 in. Ceiling opening – width 10.25 in. Ceiling opening – height 8.5 in. Housing dimens[...]
-
Page 12
12 Model : VFB 080D4H 1 W ARRANTY DEL T A ELECTRONICS THREE YEAR LIMITED W ARRANTY Delta Electronics Inc. (“Delta Electronics”) warrants to the original consumer purchaser in the USA that the Breez ventilation fan products will be free from defects in material or workmanship. This warranty is limited to three (3) years from the original date of[...]