Go to page of
Similar user manuals
-
Indoor Fireplace
Desa E32LH
28 pages 2.42 mb -
Indoor Fireplace
Desa VMH26TPB 14
28 pages 0.77 mb -
Indoor Fireplace
Desa BHDV37N/P
44 pages 1.29 mb -
Indoor Fireplace
Desa Wall Mantel and Base W26LT
8 pages 0.61 mb -
Indoor Fireplace
Desa (V)G42H/50H
16 pages 1.49 mb -
Indoor Fireplace
Desa VF48H(i)(R)
20 pages 1.97 mb -
Indoor Fireplace
Desa (V)V36P-B SERIES, VV36PC1 SERIES
40 pages 4.93 mb -
Indoor Fireplace
Desa CF26PR
30 pages 1.03 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Desa (V)B36L, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Desa (V)B36L one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Desa (V)B36L. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Desa (V)B36L should contain:
- informations concerning technical data of Desa (V)B36L
- name of the manufacturer and a year of construction of the Desa (V)B36L item
- rules of operation, control and maintenance of the Desa (V)B36L item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Desa (V)B36L alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Desa (V)B36L, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Desa service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Desa (V)B36L.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Desa (V)B36L item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
For more information, visit www .desatech.com SA VE THIS BOOK This book is valuable. In addition to instructing you on how to install and maintain your appliance, it also contains information that will enable you to obtain re- placement parts or accessory items when needed. Keep it with your other important papers. ?[...]
-
Page 2
www .desatech.com 109034-01G 2 SAFETY the manufacturer's instructions [...]
-
Page 3
www .desatech.com 109034-01G 3 SPECIFICA TIONS 8.125" 12.875" 10.188" 9.625" 37.25" 33" 38" 36" 21.5" 32" 6.75" 34.75" 14.438" 19.375" 1" 14" 38" 1.75" 0.750" 22.5" 21.125" 0" TO BOTTOM OUTSIDE AIR (LEFT SIDE ONL Y) TOP SP ACERS 0.75" [...]
-
Page 4
www .desatech.com 109034-01G 4 FIREPLACE INST ALLA TION SELECTING LOCA TION T o det erm ine saf est and mos t efci ent loc ati on for replace, you must take into consideratio n the following guidelines: 1. Locat ion must allow for proper cleara nces (see Figures 1 and 2). 2. Consider a location where replace will not be affected by drafts,[...]
-
Page 5
www .desatech.com 109034-01G 5 HEARTH ExTENSION A hearth extension projecting a minimum of 16" in front of and a minimum of 8" beyond each side of replace opening is required to protect combustible oor construction in front of replace. Fabricate a hearth extension using a material which meets the following specications: a laye[...]
-
Page 6
www .desatech.com 109034-01G 6 FI RE PL AC E I NS T AL LA TIO N Continued Figure 4 - Mantel Clearances to Combustible Material Electrical Bushing Electrical Cover Plate Rocker Switch Figure 6 - Fan Switch-Electrical Bushing Electrical Housing Wire Nut (3x) (Not Supplied) Outer Wrapper of Fireplace Electrical Cover Plate and Electrical Bushing Firep[...]
-
Page 7
www .desatech.com 109034-01G 7 Figure 8 - Lineal Gain LINEAL GAIN P ART NO. DESCRIPTION GAIN 36" Fireplace 37 1 / 2 " 12-8DM 12-8HT Pipe Section 10 5 / 8 " 18-8DM 18-8HT Pipe Section 16 5 / 8 " 24-8DM 24-8HT Pipe Section 23 5 / 8 " 36-8DM 36-8HT Pipe Section 34 5 / 8 " 48-8DM 48-8HT Pipe Section 46 5 / 8 " RT -8DM[...]
-
Page 8
www .desatech.com 109034-01G 8 VENTING INST ALLA TION Continued Figure 9 - T ypical Offset Installation Return Elbow Offset Elbow Return Elbow Offset Elbow 6' Max. 6' Max. 6' Max. 6' Max. 6' Max. 6' Max. Return Elbow Offset Elbow Offset Elbow Return Elbow A B C Offset Elbow Ceiling Support Pipe 12S-8DM Return Elbow [...]
-
Page 9
www .desatech.com 109034-01G 9 Figure 1 1 - Elbow Offset B A Screws Figure 10 - Ceiling Support Pipe 12S-8DM RISE A B 48" 24" 18" 12" 4 3 / 8 " 16 3 / 8 " ELBOW SET ONL Y 9 3 / 4 " 25 1 / 2 " 1 12 3 / 4 " 30 3 / 4 " 1 15" 3[...]
-
Page 10
www .desatech.com 109034-01G 10 VENTING INST ALLA TION Continued 14 3 / 8 " (36.5 cm) 30" (76.2 cm) 1" (2.5 cm) 1" (2.5 cm) Minimum Measurements 1" (2.5 cm) Opening "A" Pitch Slope Opening Flat 0° 15" V6F-8D[...]
-
Page 11
www .desatech.com 109034-01G 1 1 Nail Only Outer Perimeter of Flashing Storm Collar Underlap Shingles at Bottom Overlap Shingles T op and Sides Only Figure 15 - Flashing Installation Figure 16 - Storm Collar Chimney Pipe W aterproof Caulk Storm Collar Flashing Storm Collar Installation (SC1 or SC2) Place storm collar over pipe and slide down until [...]
-
Page 12
www .desatech.com 109034-01G 12 10' 2' Min. 10' 3' Min. 2' Min. 3' Min. Level of Flue Gas Outlet Figure 19 - 10 Foot Rule All ue gas outlet chimney terminations must extend a minimum of 3 feet in height above high est poin t where it passes thro ugh roof and must be at least 2 fe[...]
-
Page 13
www .desatech.com 109034-01G 13 OPTIONAL GAS LINE INST ALLA TION Figure 21 - Gas Line Knockout Side Firebrick Finished Side Refractory Knockout Plug Outside of Fireplace Gas Line Conduit Insulation Gas Conduit Cover 1/2" Dowel Gas line hook up should be done by your supplier or a qualied service person. Note: Before you proceed, make sure y[...]
-
Page 14
www .desatech.com 109034-01G 14 OPTIONAL GAS LINE INST ALLA TION Continued has been used for wood burn- be cleaned of soot, creosote and ?[...]
-
Page 15
www .desatech.com 109034-01G 15 Figure 24 - Damper Handle Location OPERA TION AND MAINTENANCE Continued Damper handle, which opens and closes damper blade, is located inside rebox at cen ter t ow ard s bac k wal l (s ee Fi gur e 24 ). Pushing handle back into keyway slot will[...]
-
Page 16
www .desatech.com 109034-01G 16 P ARTS 1 1 27 30 23 22 24 10 14 25 4 17 3 2 1 18 5 20 28 12 7 15 9 16 13 8 26 6 29 19 21[...]
-
Page 17
www .desatech.com 109034-01G 17 P ARTS This list contains replaceable parts used in your replace. NO. PART NO. DESCRIPT[...]
-
Page 18
www .desatech.com 109034-01G 18 ACCESSORIES ?[...]
-
Page 19
www .desatech.com 109034-01G 19 BLOWER KIT - BK SLIP SECTION ?[...]
-
Page 20
DESA Heating, LLC 2701 Industrial Drive P .O. Box 90004 Bowling Green, KY 42102-9004 www .desatech.com 1-866-672-6040 109034-01 Rev . G 01/08[...]
-
Page 21
FO YER À BOIS MANUEL DE FONCTIONNEMENT ET D'INST ALLA TION DU PROPRIÉT AIRE MODÈLES (V)B36, (V)B36I, (V)B36L, (V)B36LI ET CWB36C ICC-ES #ESR-2542 Pour plus de détails, visitez le site www .desatech.com CONSERVEZ CE MANUEL Ce manuel est important. En plus de fournir des ins- tructions sur l'installation et l'entretien de cet appar[...]
-
Page 22
www .desatech.com 109034-01G 2 SÉCURITÉ POUR VOTRE SÉCURITÉ • N'entreposez pas et n'utilisez pas d'essence ou d'autres va- à proximité de cet appareil ou de tout autre appareil. • Cet appareil produit des tem- pératures[...]
-
Page 23
www .desatech.com 109034-01G 3 CARACTÉRISTIQUES 20,6 cm (8,125 po) 32,7 cm (12,875 po) 25,9 cm (10,2 po) 24,4 cm (9,625 po) 94,6 cm (37,25 po) 83,8 cm (33 po) 96,5 cm (38 po) 91,4 cm (36 po) 54,6 cm (21,5 po) 81,3 cm (32 po) 17,1 cm (6,75 po) 86,3 cm (34,75 po) 36,6 cm (14,4 po) 49,2 cm (19,4 po) 35,6 cm (14 po) 96,5 cm (38 po) 4,4 cm (1,75 po) 1,[...]
-
Page 24
www .desatech.com 109034-01G 4 INST ALLA TION DU FO YER SÉLECTION D'UN EMPLACEMENT Pour déterminer l'emplacement du foyer le plussûr et le plus efcace, vous devez tenir compte des consignes suivantes : 1. L'emplacement doit permettre les déga- gementsappropriés(voirgures1et2). 2[...]
-
Page 25
www .desatech.com 109034-01G 5 Z (non fou rni) do it être fab riqué selon la hauteur de la plateforme. Le protecteur cont re les brais es doit dépa sser sou s le foye r d' une d ista nce m inim um de 4 c m (1 1 / 2 po ). Le pr ote cte ur cont re les br ais es do it êtr e fabr iqu é en t?[...]
-
Page 26
www .desatech.com 109034-01G 6 IN ST A LLA TI ON D U FO YE R suite Figure 4 - Dégagements du manteau de foyer par rapport aux matériaux combustibles T raversée électrique Plaque- couvercle électrique Interrupteur à bascule Figure 6 - Traversée électrique d'interrupteur de ventilateur MANTEAUX DE FOYER Un ma nt eau de foy er peu t êt r[...]
-
Page 27
www .desatech.com 109034-01G 7 Figure 7 - Prêt-à-monter de gaine d'air extérieur Fixez aux colliers avec du ruban métallique, des vis ou des attaches (dimensions minimalesde0,635x51cm(1/4x20po)) L'emplacement de la prise d'air doit tenir compte des buissons et de la neige Hotte de ventilation requise po[...]
-
Page 28
www .desatech.com 109034-01G 8 ASSEMBLAGE ET INST ALLA TION D'UN SYSTÈME DE CHEMINÉE À DOUBLE P AROI Chaque section de cheminée à double paroi consiste en un conduit extérieur galva- nisé, un conduit de fumée intérieur en acier inoxydable et une entretoise métallique. Les sections de conduit doivent être assemblées indépendamment [...]
-
Page 29
www .desatech.com 109034-01G 9 INST ALLA TION DU SY STÈME DE VENTILA TION suite Figure 9 - Installation représentative d'un décalage UTILISA TION DE COUDES DE 1. An d'obtenir le décalage voulu, vous pouvez installer toute combinaison de sections de conduit[...]
-
Page 30
www .desatech.com 109034-01G 10 Figure 1 1 - Coude de décalage INST ALLA TION DU SY STÈME DE VENTILA TION suite B A Vis T A B L E AU DE S D É C AL A GE S (H A UT E UR D U SY S TÈ M E : 6, 7 à 1 5, 2 m [ 2 2 à 50 p i] ) DÉCALAGE MONTÉE LONGUEUR DE LA CHEMINÉE A B 122 cm (48 po) 91,5 cm 61 cm (24 po) 45,7 cm (18 po) [...]
-
Page 31
www .desatech.com 109034-01G 1 1 INST ALLA TION DU SY STÈME DE VENTILA TION suite Dimensions Minimales 76,2 cm (30 po) Ouverture « A » 36,5 cm (14 3 / 8 po) 2,5 cm (1 po) 2,5 cm (1 po) 2,5 cm (1 po) Inclinaison Pente Ouverture « A » max. N o de modèle des solins utilisés Plane 0 ° 38,1 cm (15po) V6F-8DM 0-6/12 26,6 ° 16 1 / 8 " V6F[...]
-
Page 32
www .desatech.com 109034-01G 12 Figure 15 - Installation des solins Figure 16 - Mitre Installation de solins sur une toiture en métal L'in stall ation de solins sur une toitur e en métal exige l'utilisation de ruban de mastic entre les solins et la toiture. Les solins doivent être xés à la toiture à l'aide [...]
-
Page 33
www .desatech.com 109034-01G 13 Des termina isons avec section coulis sante de 40,6cm (16po)sont disponibles.Les modè - les RTT -8DM et RTTL-8DM sont approuvés pour les inst alla tion s de soli ns. S'il y a lieu, ces terminaisons réglables peuvent être utilisées avec un assemblage de conduits pour obtenir la hauteur a[...]
-
Page 34
www .desatech.com 109034-01G 14 IN ST A LLA TI ON D' UN E CAN AL ISA TI ON DE G AZ E N OPT ION Figure 21 - Alvéole défonçable de la canalisation de gaz Le raccordement de la canalisation de gaz doit être ef fectué par le fournisseur ou par du personnelqualié. Remarque : avant de commencer , assurez- vous que l'approvisionnemen[...]
-
Page 35
www .desatech.com 109034-01G 15 3. Acheminez une canalisation de gaz en fernoir de1,27 cm(1/2 po)dansle foyer par l'arrière par le manchon de conduit de canalisation de gaz (ajoutez de la hauteur si vous utilisez une plate-forme d'élévation). Prévoyez une longueur sufsante de conduit?[...]
-
Page 36
www .desatech.com 109034-01G 16 FONCTIONNEMENT ET ENTRETIEN Figure 23 - Portes vitrées Nettoyage du verre Nettoyez le verre à l'aide d'un produit de nettoyag e commercia l pour le verre ou à l'eau savonneuse. N'utilisez pas de produit abrasif pour nettoyer le verre. Ne nettoyez pas le ver re avec de l'ea u froid e si le [...]
-
Page 37
www .desatech.com 109034-01G 17 Figure 24 - Emplacement de la poignée du clapet FONCTIONNEMENT ET ENTRETIEN suite FONCTIONNEMENT DE LA POIGNÉE DU CLAPET La poignée du clapet, qui ouvre et ferme la pale du clapet, est située dans la chambre de combustion au centre vers le mur arrière (voir gure 24). Poussez la poignée dans[...]
-
Page 38
www .desatech.com 109034-01G 18 PIÈCES 1 1 27 30 23 22 24 10 14 25 4 17 3 2 1 18 5 20 28 12 7 15 9 16 13 8 26 6 29 19 21[...]
-
Page 39
www .desatech.com 109034-01G 19 PIÈCES Cette liste comprend les pièces de rechange utilisées dans votre foyer . Nº Nº DE PIÈCE DESCRIPTION QTÉ 1 ** Pl[...]
-
Page 40
www .desatech.com 109034-01G 20 SOLINS DE TOITURE INCLINAISON 0 À 6/12 - V6F-8DM INCLINAISON 6/12 À 12/12 - V12F-8DM ACCESSOIRES CONDUIT À DOUBLE P AROI 12-8DM 12-8HT 18-8DM 18-8-HT 24-8DM 24-8HT 48-8DM 48-8HT ÉCRAN DE TIRAGE (terminaison à tête ronde uniquement) ADS-8DM ?[...]
-
Page 41
www .desatech.com 109034-01G 21 PR ÊT -À -MO NT ER D E SOU FF LE UR - B K TERMINAISONS À TÊTE RONDE RT -8DM, RTL-8DM, RT -8HT , RL T -8HT TERMINAISONS À TÊTE RONDE A VEC SECTION COULISSANTE RTT -8DM, RTTL- 8DM, RTT -8HT , RTTL -8HT PRÊT -À-MONTER DE GAINE D'AIR EXTÉRIEUR POUR INST ALLA TION SUR UN MUR LA TÉRAL - AK4 PRÊT -À-MONTER [...]
-
Page 42
www .desatech.com 109034-01G 22 _____________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ____________________________________________[...]
-
Page 43
www .desatech.com 109034-01G 23 _____________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ____________________________________________[...]
-
Page 44
DESA Heating, LLC 2701 Industrial Drive P .O. Box 90004 Bowling Green, KY 42102-9004, États-Unis www .desatech.com 1-866-672-6040 NOT A UPC 109034-01 Rev . G 01/08 109034 01[...]