Desa VM36EP manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Desa VM36EP, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Desa VM36EP one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Desa VM36EP. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Desa VM36EP should contain:
- informations concerning technical data of Desa VM36EP
- name of the manufacturer and a year of construction of the Desa VM36EP item
- rules of operation, control and maintenance of the Desa VM36EP item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Desa VM36EP alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Desa VM36EP, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Desa service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Desa VM36EP.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Desa VM36EP item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Sav e this manual for future reference. For more information, visit www .desatech.com MODELS M36E(B,H), M42E(B ,H), VM36E(B,H) AND VM42E(B ,H) NA TURAL GAS MODELS M36EP(B,H), M42EP(B ,H), VM36EP(B,H) AND VM42EP(B,H) PROP ANE/LP GAS B-V ENT DE CORA TIV E E LEC TR ONI C I GNI TION GA S F IRE PLA CE OWNER’S OPERA TION AND INST ALLA TION MANUAL FOR Y[...]

  • Page 2

    www .desatech.com 108796-01K 2 W ARNING: Improper installation, adjustment, altera- tion, service or maintenance can cause injury or prop- erty damage. Refer to this manual for correct installation and operational procedures. For assistance or addi- tional information consult a qualified installer , service agency or the gas supplier . NOT FOR USE[...]

  • Page 3

    www .desatech.com 108796-01K 3 SAFETY INFORMA TION W ARNING: This product c o n t a i n s a n d / o r g e n e r a t e s chemicals known to the State of California to cause cancer or birth defects or other reproduc- tive harm. IMPORTANT: Read this owner’s man ual caref ully an d co mpl etel y before trying to assemble, op- erate or service this ?[...]

  • Page 4

    www .desatech.com 108796-01K 4 11. Keep the area around your fireplace clear of combustible materials, gasoline and other flammable vapor and liquids. Do not run fire- place where these are used or stored. Do not place items such as clothing or decorations on or around fireplace. 12. Do not use this fireplace to cook food or burn paper or othe[...]

  • Page 5

    www .desatech.com 108796-01K 5 W ARN ING: Ins tall atio n of this appliance should be done by a qualified service person well trained in the installation of such appliances. Y ou will also need a building permit from your local Building and Safety Commissioner before installing this appliance; otherwise your insurance co. may not c over this appli[...]

  • Page 6

    www .desatech.com 108796-01K 6 Model 36 Model 42 Mo del 3 6 Mo de l 42 Mo del 3 6 Model 42 A 29" 36" I 40 1 / 4 " 44 1 / 4 " Q 13 7 / 8 " 14" B 5/8" 5/8" J 21" 24" R 10 1 / 2 " 12 1 / 2 " C 41" 48" K 8" 9" S 2 1 / 2 " 2 1 / 2 " D 12" 14" L 34 3 / 4 &[...]

  • Page 7

    www .desatech.com 108796-01K 7 PRE-INST ALLA TION PREP ARA TION CLEARANCES Minimum clearances to combustibles are: • Back and Sides of Outer Surround . . . 0" min. • Drywall to Sides of Front Face (Nailing Flanges) . . . . . . . . . . . . . . 0" min. • “B” V ent Surfaces . . . . . . . . . . . . . . . . 1" min. • Ceiling t[...]

  • Page 8

    www .desatech.com 108796-01K 8 PRE-INST ALLA TION PREP ARA TION Continued FRAMING 1. Frame appliance enclosure as illustrated in Figures 7 and 8. Note: If a wall covering is used to line the enclosure, then all measurements must be from the surface of the covering. 2. Place the appliance into the framing and secure it. Note: If appliance is to be r[...]

  • Page 9

    www .desatech.com 108796-01K 9 INST ALLING TRANSITION PIPE AND ST ARTER COLLAR The transition pipe and starter collar shown in Figu re 9 are sup plie d wit h the firep lace , una ttac hed and read y fo r ins tal lat ion . Rem ove the star ter col lar and set asid e. Sli de the tran siti on pip e over the vent collar and attach with a minimum of th[...]

  • Page 10

    www .desatech.com 108796-01K 10 Maintain Listed Clearance 12' Min. 12' Min. 45 45 6' 8' 12' Min. 60 45 Position Firestop Position Firestop Position Firestop Listed V ent Cap Listed V e nt Cap Listed V e nt Cap Maintain Listed Clearance Maintain Listed Clearance Maintain Listed Clearance Maintain Listed Clearance Maintain Li[...]

  • Page 11

    www .desatech.com 108796-01K 1 1 CHECKING FOR PROPER VENTING After completing and checking the electrical, gas and vent connections, follow the lighting instructions and allow the main burner to run for approximately 5 minutes. Hold a lighted match or cigarett e near the top edge of the firepla ce opening and play it along the entire length of the[...]

  • Page 12

    www .desatech.com 108796-01K 12 3" Min. (76 mm) Side W all Of Appliance GAS LINE HOOK-UP W ARNING: Gas line hookup should be done by your gas supplier or a qualified service person. W ARNING: Before you pro- cee d, m ake sur e yo ur gas su pply is OFF . A manual shutof f valve has been included in the applianceʼ s gas supply system. Y ou may[...]

  • Page 13

    www .desatech.com 108796-01K 13 P I L O T ON OFF IN OUT Figure 19 - Connecting Flexible Gas Line to Millivolt V alve Gas Shutoff V alve Flexible Gas Line Do NOT Kink 1/2" NPT Incoming Gas Line Note: 1) Wire Connections Not Shown for Clarity 2) * 1/8" NPT Plugged T apping Red Surface Indicates For Propane/LP Use Only Pilot Adj Inlet Pressu[...]

  • Page 14

    www .desatech.com 108796-01K 14 0.5" 0.5" Figure 22 - Pan and Ember Material Clearances Grate Burner Pan Pan and Ember Material INST ALLA TION Continued LO G P LA CEM EN T F OR M 36E , M36 EP , VM E36 AN D VM 36E P MO DE LS 1. Pla ce sm all front righ t lo g (lo g 1) on rig ht fr ont of grate as shown in Figure 23. 2. Pl ace la rge bac k [...]

  • Page 15

    www .desatech.com 108796-01K 15 INST ALLA TION Continued LO G P LA CEM EN T F OR M 42E , M42 EP , VM E42 AN D VM 42E P MO DE LS 1. Place lar ge back log (log 1) onto grate making sure notches rest over grate (see Figure 27). 2. Ins ert l owe r end o f lo g 2A betw ee n th e first two grat e finger s and positi on the upper end into the notc h on [...]

  • Page 16

    www .desatech.com 108796-01K 16 INST ALLA TION Continued COMBUSTION AIR KIT MODEL AK4 (OPTIONAL) The outside air kit may be installed on the left side of the fireplace only . The vent can be installed through any outside wall a minimum of three feet below fireplace termination cap. The handle to operate the damper door for the outside air inlet w[...]

  • Page 17

    www .desatech.com 108796-01K 17 6. Repeat the process for the opposite door assembly . 7. T o adjust the doors, slide them partially open. Using a screwdriver , loosen the hold-down screws in the spring clip (see Figure 34) and pivot plate. 8. Close both doors until evenly joined at the middle and note the gap at the outer edges of the face. 9. Reo[...]

  • Page 18

    www .desatech.com 108796-01K 18 OPERA TING FIREPLACE FOR YOUR SAFETY READ BEFORE LIGHTING W ARNING: If you do not fol- low these instructions exactly , a fire or explosion may result causing property damage, per- sonal injury or loss of life. A. This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instruc[...]

  • Page 19

    www .desatech.com 108796-01K 19 TO TURN OFF GAS TO APPLIANCE 1. T urn off the wall switch. 2. T urn off all electric power to the appliance if service is to be performed. 3. Fully open glass doors if installed. 4. Remove front hearth brick and control access panel. 5. T urn gas control knob clockwise to “OFF”. Do not force. 6 . Replace fr ont r[...]

  • Page 20

    www .desatech.com 108796-01K 20 CLEANING AND MAINTENANCE W ARNING: Installation and repair should be done by a quali - fied service person. The appli- ance sho uld be ins pect ed b efor e each use and at least annually by a qualified service person. More frequent cleaning may be required due to excessive lint from carpeting, bedding mate- rial, p[...]

  • Page 21

    www .desatech.com 108796-01K 21 Robertshaw MODEL SP745 IGNITION CONTROL STEP DOWN TRANSFORMER PV GND PV/MV TR MV TH VENT SAFETY SHUTOFF SWITCH MANUAL DAMPER SWITCH IGN EV2 SUPPL Y INCOMING MAIN GAS EV1 TO GAS LINE BURNER 24V AC 120V AC 120V AC INCOMING OR BREAKER) (FUSE BOX OFF ON (SUPPLIED) WALL SWITCH GREEN BLACK WHITE 120v , 60Hz, 0.7A ELECTRICA[...]

  • Page 22

    www .desatech.com 108796-01K 22 TROUBLESHOO TING Note: Before troubleshoot ing the system, make sure the gas shutoff valve is ON. The two most common causes of a malfunctioning gas appliance are: 1. Loose wiring connections 2. Construction debris clogging the pilot and/or gas control valve filter OBSERVED PROBLEM Ignitor will not spark or pilot wi[...]

  • Page 23

    www .desatech.com 108796-01K 23 TROUBLESHOO TING Continued W ARNING: If you smell gas • Shut off gas supply . • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor ’ s phone. Follow the gas supplier ’ s instructions. • If y[...]

  • Page 24

    www .desatech.com 108796-01K 24 ILL USTRA TED P ARTS BREAKDO WN MODELS M36E(B,H), M36EP(B,H), M42E(B,H), M42EP(B,H), VM36E(B,H), VM36EP(B,H), VM42E(B,H) AND VM42EP(B,H) 51 21 3 25 2 1 10 1 1 6 57 57 22 50 18 9 8 17 70 68 65 67 52 13 61 14 45 43 48 59/60 62 44 4 40 64 69 39 66 71 42 41 67 56 23 7 46 19 47 7 47 54 55 5 17 16 12 15 52 33 31 28 32 27 1[...]

  • Page 25

    www .desatech.com 108796-01K 25 P ARTS LIST This list contains replaceable parts used in your heater . When ordering parts, follow the instructions listed under Replacement Parts on page 20 of this manual. ** Not a field replaceable part. KEY NO. M 3 6E (P ) ( B, H) V M 36 E( P ) (B ,H ) M 4 2E (P ) ( B, H) V M 42 E( P ) (B ,H ) DE SCR IP TI ON Q [...]

  • Page 26

    www .desatech.com 108796-01K 26 KEY NO. M3 6(B ,H ) VM 36( B, H) M4 2(B ,H ) VM 42( B, H) D ESC RIP TI ON QTY 12 106658-02 107812-02 Left Refractory , Std. Brick (M36EB/ME42B) 1 108164-02 108169-02 Left Refractory , Herringbone (M36EH/M42EH) 1 106658-01 107812-01 Left Refractory , Std. Brick (VM36EB/VM42EB) 1 108164-01 108169-01 Left Refractory , H[...]

  • Page 27

    www .desatech.com 108796-01K 27 ILL USTRA TED P ARTS BREAKDO WN LOGSETS FOR MODELS M36(B,H), M36P(B,H), VM36(B,H) AND VM36P(B,H) KEY NO. P ART NUMBER DESCRIPTION QTY . - 107999-01 Log Set 1 108724-01 Right Front 9" Split Log 1 2 901098-01 Rear Log 1 3 108720-01 T op Right Log - 1 1 3 / 4 " 1 4 108721-01 T op Right Log - 16" 1 5 10872[...]

  • Page 28

    www .desatech.com 108796-01K 28 KEY NO. P ART NUMBER DESCRIPTION QTY . - 107999-02 Log Set 1 901098-02 Rear Log 1 2A 108723-01 Left Front Log - 1 1" 1 2B 108839-01 Right Front Log - 15 3 / 4 " Round 1 3 108722-01 T op Left Log - 13 1 / 2 " Y -Log 1 4 108838-01 Inside T op Left Log - 15 3 / 4 " Split 1 5 108721-01 Inside T op Rig[...]

  • Page 29

    www .desatech.com 108796-01K 29 ACCESSORIES NOTICE: All accessories may not be available for all fireplace models. Purchase these firebox accessories from your local dealer . If they can not supply these accessories, call DESA ʼ s Sales Department at 1-866-672-6040 for information. Y ou can also write -to the address listed on the back page of t[...]

  • Page 30

    www .desatech.com 108796-01K 30 _____________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ____________________________________________[...]

  • Page 31

    www .desatech.com 108796-01K 31 _____________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ____________________________________________[...]

  • Page 32

    LIMITED WARRANTY VENT -FREE FIREBO X DESA warrants this product to be free from defects in materials and components for four (4) years from the date of first purchase, provided that the product has been properly installed, operated and maintained in accordance with all applicable instructions. T o make a claim under this warranty the Bill of Sale [...]