Go to page of
Similar user manuals
-
Indoor Fireplace
Dimplex None
2 pages 0.16 mb -
Indoor Fireplace
Dimplex CASTILLO CASTILLO CS3540
16 pages 0.39 mb -
Indoor Fireplace
Dimplex BF45DXP
14 pages 0.67 mb -
Indoor Fireplace
Dimplex DFI23TRIMX
12 pages 1.16 mb -
Indoor Fireplace
Dimplex EF3003
4 pages 0.15 mb -
Indoor Fireplace
Dimplex DF3003
19 pages 0.74 mb -
Indoor Fireplace
Dimplex DFG3033
22 pages 0.9 mb -
Indoor Fireplace
Dimplex COMPACT FIREPLACE
11 pages 0.25 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Dimplex DFI2309, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Dimplex DFI2309 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Dimplex DFI2309. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Dimplex DFI2309 should contain:
- informations concerning technical data of Dimplex DFI2309
- name of the manufacturer and a year of construction of the Dimplex DFI2309 item
- rules of operation, control and maintenance of the Dimplex DFI2309 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Dimplex DFI2309 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Dimplex DFI2309, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Dimplex service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Dimplex DFI2309.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Dimplex DFI2309 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
PARTS AND SERVICE MANUAL FOR THE 23” INSERT FIREPLACE MODEL NUMBER: DFI2309[...]
-
Page 2
TABLE OF CONTENTS O P E R A T I O N P A G E 1 PARTS DRAWING PAGE 3 P A R T S L I S T P A G E 4 WIRING DIAGRAM PAGE 5 LIGHT BULB REPLACEMENT PAGE 6 MAIN ON/OFF SWITCH REPLACEMENT PAGE 8 LOW HEAT ON/OFF SWITCH REPLACEMENT PAGE 9 HIGH HEAT ON/OFF SWITCH REPLACEMENT PAGE 10 FLAME MOTOR/FLAME ROD REPLACEMENT PAGE 11 HEATER ASSEMBLY REPLACEMENT PAGE 12 L[...]
-
Page 3
1 DFI2309 OPERATION MAIN ON/OFF FLAME ON/OFF SWITCH The ON/OFF switch supplies power to all unit functions. When this switch is in the ON position the flame effect operates without heat. LOW HEAT SWITCH The LOW HEAT ON/OFF SWITCH supplies power to the heat er fan and the heater element. When the switch is in the ON position the heater operates on L[...]
-
Page 4
2 DFI2309 REMOTE CONTROL The remote control has a range of approxim ately 50ft. (15.25m) it does not have to be pointed at the fireplace and can pass through most obstacles (including walls). It is supplied with one of 243 i ndependent frequencies to prevent interference with other units. The frequency designation is indicate d on the back of the t[...]
-
Page 5
3 DFI2309 10 9 6 4 11 1 2 3 7 8 5 12[...]
-
Page 6
4 DFI2309 REPLACEMENT PARTS 23” FIREPLACE INSERT REPLACEMENT PART REPLACEMENT PART NO. 1. MAIN ON/OFF SWITCH 2800090100RP* 2. LOW HEAT ON/OFF SWITCH 2800090100RP* 3. HIGH HEAT ON/O FF SWITCH 2800090100RP* 4. CORDSET 4100090101RP 5. HEATER ASSEMBLY 2200490300RP 6. CUTOUT 2300270200RP 7. MIRROR 5900350100RP 8. LOGSET 0438200200RP 9. FLICKER MOTOR 2[...]
-
Page 7
5 DFI2309 WIRING DIAGRAM[...]
-
Page 8
6 DFI2309 If unit was operating prior to servicing allow at least 10 minutes for light bulbs and heating element to cool off to av oid accidental burning of skin. Disconnect power before attempting any main tenance or cleaning to reduce the risk of electric shock or damage to persons. Light bulbs need to be replaced when you notice a dark section o[...]
-
Page 9
7 DFI2309 If unit was operating prior to servicing allow at least 10 minutes for light bulbs and heating element to cool off to av oid accidental burning of skin. Disconnect power before attempting any main tenance or cleaning to reduce the risk of electric shock or damage to persons. BULB REQUIREMENTS Quantity 2 clear chandelier or candelabra bulb[...]
-
Page 10
8 DFI2309 If unit was operating prior to servicing allow at least 10 minutes for light bulbs and heating element to cool off to av oid accidental burning of skin. Disconnect power before attempting any main tenance or cleaning to reduce the risk of electric shock or damage to persons. TO REPLACE MAIN ON/OFF SWITCH 1. Remove the trim and firebox fro[...]
-
Page 11
9 DFI2309 If unit was operating prior to servicing allow at least 10 minutes for light bulbs and heating element to cool off to av oid accidental burning of skin. Disconnect power before attempting any main tenance or cleaning to reduce the risk of electric shock or damage to persons. TO REPLACE LOW HEAT ON/OFF SWITCH 1. Remove the trim and firebox[...]
-
Page 12
10 DFI2309 If unit was operating prior to servicing allow at least 10 minutes for light bulbs and heating element to cool off to av oid accidental burning of skin. Disconnect power before attempting any main tenance or cleaning to reduce the risk of electric shock or damage to persons. TO REPLACE HIGH HEAT ON/OFF SWITCH 1. Remove the trim and fireb[...]
-
Page 13
11 DFI2309 If unit was operating prior to servicing allow at least 10 minutes for light bulbs and heating element to cool off to av oid accidental burning of skin. Disconnect power before attempting any main tenance or cleaning to reduce the risk of electric shock or damage to persons. TO REPLACE FLAME MOTOR/FLAME ROD 1. Remove the trim and firebox[...]
-
Page 14
12 DFI2309 If unit was operating prior to servicing allow at least 10 minutes for light bulbs and heating element to cool off to av oid accidental burning of skin. Disconnect power before attempting any main tenance or cleaning to reduce the risk of electric shock or damage to persons. TO REPLACE HEATER ASSEMBLY 1. Remove the trim and firebox from [...]
-
Page 15
13 DFI2309 If unit was operating prior to servicing allo w at least 10 minutes for light bulbs and heating element to cool off to av oid accidental burning of skin. Disconnect power before attempting any main tenance or cleaning to reduce the risk of electric shock or damage to persons. TO REPLACE LIGHT HARNESS 1. Remove the trim and firebox from m[...]
-
Page 16
14 DFI2309 If unit was operating prior to servicing allow at least 10 minutes for light bulbs and heating element to cool off to av oid accidental burning of skin. Disconnect power before attempting any main tenance or cleaning to reduce the risk of electric shock or damage to persons. TO REPLACE POWER CORD 1. Remove the trim and firebox from mante[...]