Go to page of
Similar user manuals
-
Heat Pump
Dometic 630516
16 pages 0.36 mb -
Heat Pump
Dometic 620525
16 pages 0.36 mb -
Heat Pump
Dometic HB 2500
28 pages 2.6 mb -
Heat Pump
Dometic RM2454
16 pages 0.2 mb -
Heat Pump
Dometic 620515
16 pages 0.36 mb -
Heat Pump
Dometic 630515
16 pages 0.36 mb -
Heat Pump
Dometic 620526
16 pages 0.36 mb -
Heat Pump
Dometic 630025.331
10 pages 0.18 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Dometic 630025.331, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Dometic 630025.331 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Dometic 630025.331. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Dometic 630025.331 should contain:
- informations concerning technical data of Dometic 630025.331
- name of the manufacturer and a year of construction of the Dometic 630025.331 item
- rules of operation, control and maintenance of the Dometic 630025.331 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Dometic 630025.331 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Dometic 630025.331, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Dometic service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Dometic 630025.331.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Dometic 630025.331 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
1 INST ALLA TION & OPERA TING INSTRUCTIONS USA SERVICE OFFICE Dometic Corporation 509 South Poplar Street LaGrange, IN 46761 260-463-4858 CANADA Dometic Distribution 866 Langs Drive Cambridge, Ontario CANADA N3H 2N7 519-653-4390 For Service Center Assistance Call: 800-544-4881 Important: These Instructions must stay with unit. Owner read carefu[...]
-
Page 2
2 SAFETY INSTRUCTIONS This manual has safety information and instruc- tions to help users eliminate or reduce the risk of accidents and injuries. RECOGNIZE SAFETY INFORMA TION This is the safety-alert symbol. When you see this symbol in this manual, be alert to the potential for personal injury . Follow recommended precautions and safe op- erating [...]
-
Page 3
3 Model Nominal Electrical Compressor Compressor Fan Motor Fan Motor SC FM -H ig h To tal Refrigerant Minimum AC Circuit Installed Minimum No. Capacity Rating Rated Load Locked Rated Load Locked Sp ee d Static R-22 (Oz.) Wire Size* Pr otection Weight Ge ner at or (BTU/HR) Amps Rotor Amps Rotor Max/Min Max/Min ***User (Pounds) Size** Cooling Amps Am[...]
-
Page 4
4 b. For two unit installations: Install one Air Condi- tioner 1/3 and one Air Conditioner 2/3’s from front of RV and centered from side to side. It is preferred that the air conditioner be installed on a relatively flat and level roof section measured with the RV parked on a level surface. Note: A 8° slant to either side, or front to back, is a[...]
-
Page 5
5 C. Roof Preparation 1. Opening Requirements - Before preparing the ceil- ing opening, read all of the following instructions before beginning the installation. If a roof vent opening will not be used a 14-1/4" x 14- 1/4" (±1/8") opening must be cut through the roof and ceiling of the RV. This opening must be located between the ro[...]
-
Page 6
6 D. Wiring Requirements 1. 120 VAC Supply Line Route a copper 12 AWG, with ground, 120 VAC supply line from the time delay fuse or circuit breaker box to the roof opening. a. This supply line must be located in the front portion of the 14-1/4" x 14-1/4" (±1/8") opening. b. The power MUST be on a separate 20 Amp time delay fuse or H[...]
-
Page 7
7 7. Install ceiling template by sliding lower duct over upper duct. See FIG. 11. If bolts are left loose there may not be an ad- equate roof seal or if over tightened, damage may occur to the air conditioner base or ceil- ing template. Tighten to torque specifications listed in this manual. CAUTION FIG. 11 Slide Lower Air Discharge Duct Over Upper[...]
-
Page 8
8 H. Air Distribution Box Installation 1. Remove the two return air grills and filters. 2. Slide the front end of the air box over the shafts of the thermostat and selector switch. See FIG .13. FIG. 13 Slide Air Box over Controls 3. Install four screws through legs in air box into the pre-punched holes in the ceiling template. 4. Install the return[...]
-
Page 9
9 630025.331 Installation Instructions 4. Under certain conditions, frost may form on the evaporator coil. If this should occur, inspect the filter and clean if dirty. Make sure air louvers are not obstructed. Air conditioners have a greater ten- dency to frost when the outside temperature is relatively low. This may be prevented by adjusting the t[...]
-
Page 10
10 UNIT WIRING DIAGRAM AIR BOX WIRING DIAGRAM 3106220.001 ONLY CONDUCTORS USE COPPER USE COPPER 60 HZ 1 PH 60 HZ 1 PH 115 VAC 115 VAC FIELD WIRING FIELD WIRING FACT ORY WIRING FACT ORY WIRING LINE SPLICE LINE SPLICE ELEC CONN ELEC CONN FROM A/C FROM A/C GRN/YEL 1 2 4 L1 C H 6 5 4 3 2 1 BLK YEL RED 7 8 9 GRY WHT SWITCH ROT ARY 2 1 3 GRN/YEL THERMOST[...]