Drolet 7000 MVRLC manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Drolet 7000 MVRLC, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Drolet 7000 MVRLC one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Drolet 7000 MVRLC. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Drolet 7000 MVRLC should contain:
- informations concerning technical data of Drolet 7000 MVRLC
- name of the manufacturer and a year of construction of the Drolet 7000 MVRLC item
- rules of operation, control and maintenance of the Drolet 7000 MVRLC item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Drolet 7000 MVRLC alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Drolet 7000 MVRLC, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Drolet service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Drolet 7000 MVRLC.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Drolet 7000 MVRLC item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    ULTRA FLAME FIREPLACE GAS INSERT INSTALLATION AND OPERATING INSTRUCTIONS FOR YOUR SAFETY DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE. FOR YOUR SAFETY IF YOU SMELL GAS : 1. OPEN WINDOWS 2. TURN OFF MAIN GAS SUPPLY 3. DON’T TOUCH ELECTRICAL SWITCHES 4. EXTINGUISH ANY OPEN FLAME 5[...]

  • Page 2

    TABLE OF CONTENTS : GENERAL INFORMATION :............................................................................. 2 WARNING :........................................................................................................ 3 SPECIFICATIONS :............................................................................................ 4 TO[...]

  • Page 3

    GENERAL INFORMATION : The ULTRA FLAME is a high efficiency firepl ace gas insert with an input rating of 30 000 Btu/h with natural gas and 26 000 Btu/h with propane. It features a millivolt valve with a constant pilot. This lets you choose between a wall mounted switch, a wireless remote control to turn on or off the main flam e at will. This also [...]

  • Page 4

    WARNING * INSTALLATION SHOULD BE DONE BY A QUALIFIED INSTALLER. * DO NOT BURN WOOD OR ANY OTHER MATERIAL IN THE GAS INSERT. * HOT WHEN IN OPERATION. KEEP, FURNITURE, CLOTHING AND FLAMMABLE MATERIAL AWAY FROM THE APPLIANCE. * ADVISE ADULTS AND CHILDREN TO THE HAZARD OF HIGH SURFACE TEMPERATURES AND THAT THEY S HOULD STAY AWAY TO AVOID BURNS OR CLOTH[...]

  • Page 5

    SPECIFICATIONS : Dimensions : height : 20” width : 28” depth : 15” face plate : 44 5/16” x 27 1/2” glass : 14 1/2 x 30 5/16 1400 ° F clear ceramic F u e l : N a t u r a l G a s P r o p a n e Input : 30 000 26 000 Btu/h Manifold pressure : 3.5 11 in w.c. Min inlet pressure : 5 11 in w.c. Max inlet pressure : 7 14 in w.c. Vent size : 4” [...]

  • Page 6

    TOP, SIDE AND FRONT VIEWS : 5[...]

  • Page 7

    INSTALLATION : 1. When the masonry fireplace that will r eceive the ULTRA FLAME gas insert is thoroughly cold, remove all ashes and vacuum clean. 2. Remove the glass front from the gas insert following page 11 instructions. 3. Remove the burner and firebox bottom plate from the gas insert following page 12 instructions. 4. Remove the draft hood fro[...]

  • Page 8

    11. Secure the liner to the 4” connector on the top of the ULTRA FLAME with three metal screws. 12. Push the ULTRA FLAME back in the fireplace while pulling the draft hood in place. To do so, fix two ropes to the dr aft hood sliders. Make sure the draft hood front lip is squeezed under the steel angl e to prevent any motion. The probe tube must g[...]

  • Page 9

    13. Install a 1/8” NPT plugged tapping for test gauge connection immediately upstream of the gas supply connection to the appliance. 14. Install a shutoff valve to the gas line. Tighten securely using a pipe joint compound. 15. Install a 3/8” flex connector to connect the shutoff valve to the gas valve on the fireplace. Tighten securely using a[...]

  • Page 10

    - Install the wall switch in a convenient location. Route a proper sized wire from the switch or the thermostat to the gas valve. Distance between valve Wire gage and switch 8 ’ 2 2 1 2 ’ 2 0 2 0 ’ 1 8 3 2 ’ 1 6 5 0 ’ 1 4 - Connect the wires in serial with the face plate flame switch ( green wires ). NOTE : DO NOT CONNECT THE WALL SWITCH [...]

  • Page 11

    20. Install the firebox bottom plate and burner following page 12 instructions. 21. Install the 4 logs on the burner as shown on page 13. 22. If so desired, install the embers kits as shown on page 16. 23. Install the glass front following page 11 instructions. 24. Install the face plate according to page 14 instructions. 25. Install a cap on the l[...]

  • Page 12

    GLASS FRONT REMOVAL CLEANING AND INSTALLATION : * To remove the glass front, unscrew the six screws holding it in place as shown. CAUTION : Hold the glass while unscrewing to prevent it from falling. * Clean the glass only with liquid cleaners or soaps and water, do not use abrasive cleaners which could remove the coating on the glass. WARNING : Do[...]

  • Page 13

    BURNER REMOVAL AND INSTALLATION : REMOVAL : 1. Slide the burner to the left and pull toward you. 2. To gain access to the fan, also remove the firebox bottom plate. INSTALLATION : 1. Put the bottom plate back in place. 2. Put the burner assembly back in the firebox and push to the right until it touches the firebox side. Make sure the main orif ice[...]

  • Page 14

    LOG INSTALLATION : 1. Remove the glass front as described on page 11. 2. Install the longer log in back of the firebox with locating grooves on top. 3. Install the 14” log in the front of the fire box and to the right. Make sure the log is pushed against the metal retainer on the burner face. 4. Place the front of the log with a hole in the secon[...]

  • Page 15

    FACE PLATE ASSEMBLY AND INSTALLATION : ASSEMBLY : 1. Bolt the face plate top piece to the left piece using two #10-24 x 1/2 bolts and nuts (B). 2. Place both louver assemblies in position with their pivot rod inserted through the face plate side pieces holes (C). Th e top and bottom louvers are clearly identified. WARNING : Do not invert the top an[...]

  • Page 16

    INSTALLATIONS : 1. Screw the air deflector on the unit as shown using three #10 x 1/2 metal screws. 2. Bring the face plate in position on the gas insert taking care to slip the air deflector between the top louver and the bottom of the top piece. Secure using four #10 x 1/2 metal screws (D). 3. Connect the slip on the terminals on the rocker switc[...]

  • Page 17

    REFRACTORY PANELS INSTALLATIONS : 1. Remove the front glass as described on page 11. 2. Remove the logs from the firebox. 3. Install the two sides refractory panels a nd pull them forward as mush as possible to help insertion of the back panel. 4. Place the back refractory against the back of the firebox. 5. Push the side refractory against the bac[...]

  • Page 18

    OPERATING INSTRUCTIONS LIGHTING INSTRUCTIONS : 1. Open the bottom louvers of the face plate to reach the control. 2. Turn the gas valve knob to the “OFF” position and wait 5 minutes. Note : You have to depress the gas valve knob to turn from “PILOT” to “OFF” or from “OFF” to “PILOT”. 3. Turn the gas valve knob to “PILOT”. 4.[...]

  • Page 19

    MAINTENANCE INSTRUCTIONS : TURN OFF THE GAS WITH THE SHUTDOWN VALVE AND THE ELECTRICAL POWER BEFORE SERVICING THE APPLIANCE. * The venting system and the gas insert should be inspected at least once a year. * Remove the glass front and the logs clean them if necessary. * The control compartment, air circulating passages, firebox, logs and burner sh[...]

  • Page 20

    OPTIONAL PARTS ITEM DESCRIPTION Part No QTY Face plate, silver gray enamel E5422 1 Face plate, black enamel E5420 1 Face plate, gold E5415 1 Face plate, charcoal painted E5416 1 Face plate, black painted E5418 1 Wall switch E5978 1 Remote control E5568 1 Decorative refractory kit E5988 1 REPLACEMENT PARTS ITEM DESCRIPTION Part No QTY Log kit 2232 1[...]

  • Page 21

    ____________________________ LIMITED 5 YEARS WARRANTY ____________________________ DROLET STOVES AND FIREPLACES INC. here by warrants the quality of its fireplace gas insert against manufacturing defects. Th e product shall be delivered to the buyer in good condition and the latter should inform the vendor im mediately of any defect in the product [...]