Go to page of
Similar user manuals
-
Power Supply
Eaton Electrical ASY0674
124 pages 1.59 mb -
Automobile Parts
Eaton Electrical MTR3
8 pages 0.12 mb -
Power Supply
Eaton Electrical 10000L(XL)
29 pages 0.89 mb -
Automobile Parts
Eaton Electrical TR3
8 pages 0.12 mb -
Dishwasher
Eaton Electrical CA04801001E
38 pages 1.37 mb -
Switch
Eaton Electrical Disconnect Switches
34 pages 7.09 mb -
Calculator
Eaton Electrical MN05401014E
20 pages 0.71 mb -
Switch
Eaton Electrical D77A
62 pages 2.49 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Eaton Electrical PVH131/141, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Eaton Electrical PVH131/141 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Eaton Electrical PVH131/141. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Eaton Electrical PVH131/141 should contain:
- informations concerning technical data of Eaton Electrical PVH131/141
- name of the manufacturer and a year of construction of the Eaton Electrical PVH131/141 item
- rules of operation, control and maintenance of the Eaton Electrical PVH131/141 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Eaton Electrical PVH131/141 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Eaton Electrical PVH131/141, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Eaton Electrical service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Eaton Electrical PVH131/141.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Eaton Electrical PVH131/141 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
Revised 05/01/97 M-2209-S PVH131/141 V ariable Displacement Piston Pump - 1 1 Design Service Data Vickers ® Piston Pumps[...]
-
Page 2
Eaton Hydraulics, Incorporated 2000 All Rights Reserved 473833 Screw (2 req’d) T orque 257-315 N.m. (190-232 lb. ft.) 473806 Screw (4 Req’d) T orque 103-127 N.m. (76-94 lb. ft.) 396093 O-ring (2 Req’d) V alve block (see table) Pump control (see controls pages) 471512 Pin (2 Req’d) 248935 Pin 689461 Plug (2 Req’d) T orque 12.7-[...]
-
Page 3
NOTE Right hand rotation shown. View is opposite for left hand rotation. Please refer to Overhaul Manual M-2210-S. NOTE Use shims as required to obtain 0.01 – 0.10 mm (.0004 – .004 in.) axial shaft end play . 473764 Screw (4 Req ’ d) T orque 31-37 N.m. (23-27 lb. ft.) 526758 Limiter (2 Req ’ d) Piston & Shoe[...]
-
Page 4
02 – 125160 02 – 125162 C CM Control Kit 70-250 Bar 40-130 Bar Pressure range 627391 Plug (2 Req ’ d) T orque 29-32 N.m. (21-24 lb. ft.) 396096 O-Ring (2 Req ’ d) 857672 Pressure limiter spool 857673 Load sense spool 177969 O-Ring (3 Req ’ d) 857733 CV Body 857734 Spring guide 857681 Control spring 857734 Spring guide 860750 Adj. [...]
-
Page 5
860750 Adj. screw 860748 Plug T orque 75-83 N.m. (55-60 lb. ft.) 396100 O-Ring 860606 Spring guide (2 Req ’ d) 626157 Spring Control Kit Threads Body 02 – 151906 inch 883386 02 – 151907 metric 860628 Body (see table) 398071 Plug (3 Req ’ d) T orque 9.8-10.2 N.m. (7.2-7.5 lb. ft.) 396092 O-Ring (3 Req ’ d) 407533 Plug T orque 12.1-[...]
-
Page 6
Model designation LAF – 11 – C* LAM – 11 – C* RAF – 11 – C* RAM – 11 – C* LAF – 11 – CT LAM – 11 – CT RAF – 11 – CT RAM – 11 – CT 928713 928714 928736 928737 860843 860844 860834 860835 V alve block w/ SAE ‘‘ A ’’ Pad ‘‘ A ’’ Thru – drive ‘‘ B ’’ & ‘‘ C ’’ Thru – drive Adap[...]
-
Page 7
T ypical Cross Section Position inner shaft seal facing bearing Position outer shaft seal facing shaft end Pump Startup Make sure the reservoir and circuit are clean and free of dirt and debris prior to filling with hydraulic fluid. Fill the reservoir with filtered oil to a level sufficient to prevent vortexing at suction connection to pump inlet. [...]
-
Page 8
3 4 5 8 7 6 9 10 1 2 11 12 13 14 15 16 17 1 2 Piston pump, variable displacement Maximum geometric displacement 131 - 131.1 cm 3 /r (8.0 in 3 /r) 141 - 141.6 cm 3 /r (8.64 in 3 /r) Application style Blank - Mobile application (rated speed & 250/280 bar (3600-4000 psi) pressures) QI - Quiet industrial application (1500 - 1800 rpm & 250/280 b[...]
-
Page 9
Form No. 00-000 Copyright Eaton Corporation, 0000 All rights reserved. Printed in U.S.A Eaton Hydraulics 15151 Highway 5 Eden Prairie, MN 55344 Telephone: 612 937-7254 Fax: 612 937-7130 www.eatonhydraulics.com 46 New Lane, Havant Hampshire PO9 2NB England Telephone: (44) 170-548-6451 Fax: (44) 170-548-7110[...]