Go to page of
Similar user manuals
-
Carbon Monoxide Alarm
Emerson Process Management MMI-20020979
38 pages 3.31 mb -
Carbon Monoxide Alarm
Emerson Process Management 3410
0 pages 5.66 mb -
Carbon Monoxide Alarm
Emerson Process Management MAN-0114
24 pages 1.16 mb -
Carbon Monoxide Alarm
Emerson Process Management 2051CF
24 pages 2.73 mb -
Carbon Monoxide Alarm
Emerson Process Management 3420
0 pages 5.66 mb -
Carbon Monoxide Alarm
Emerson Process Management XFC
2 pages 0.45 mb -
Carbon Monoxide Alarm
Emerson Process Management 760004-A
118 pages 2.23 mb -
Carbon Monoxide Alarm
Emerson Process Management Rosemount
4 pages 1.16 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Emerson Process Management 2051CF, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Emerson Process Management 2051CF one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Emerson Process Management 2051CF. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Emerson Process Management 2051CF should contain:
- informations concerning technical data of Emerson Process Management 2051CF
- name of the manufacturer and a year of construction of the Emerson Process Management 2051CF item
- rules of operation, control and maintenance of the Emerson Process Management 2051CF item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Emerson Process Management 2051CF alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Emerson Process Management 2051CF, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Emerson Process Management service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Emerson Process Management 2051CF.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Emerson Process Management 2051CF item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
www.rosemount.com ¢00825-0100-4101¤ Quick Installation Guid e 00825-0100-4101, Rev EA June 2010 Rosemount 2051 Sta r t End Step 1: Mount the T ransmitter Step 2: Consider Housing Rotation Step 3: Set the Jumpers Step 4: Connect the Wiring and Power Step 5: V erify Configuration Step 6: T rim the T ransmitt er Safety Instrumented Systems Product C[...]
-
Page 2
Quick Installation Guide 00825-0100-4101, Rev EA June 2010 Rosemount 2051 2 © 2010 Rosemo unt Inc. All rights re served. All marks property o f owner. Rosemount and the Rosemount logotype are registered trad emarks of Rosemount Inc. Rosemount Inc. 8200 Market B oulevard Chanhassen, M N USA 55317 T (US) (800 ) 9 99 -9307 T (Intnl) (952) 906-8888 F [...]
-
Page 3
Quick Installation Guid e 00825-0100-4101, Rev EA June 2010 Rosemount 2051 3 S TE P 1: M OUNT THE T RANSMITTER A. Applications Liquid Flow Application s 1. Place taps to the side of the line. 2. Mount beside or below the taps. 3. Mount the transmitter so that the drain/vent valves are oriented upward. Gas Flow Applicatio ns 1. Place taps in the top[...]
-
Page 4
Quick Installation Guide 00825-0100-4101, Rev EA June 2010 Rosemount 2051 4 S TE P 1 CONTI NUED ... B. Optional Mounting Brackets When installing the transmitter to one of the optional mounting brackets, torque the bracket bolts to 125 in.-lbs. (0,9 N-m). Rosemount 2051C Panel Mount (1) (1) Panel bolts are customer supplied. Pipe Mount Coplanar Fla[...]
-
Page 5
Quick Installation Guid e 00825-0100-4101, Rev EA June 2010 Rosemount 2051 5 S TE P 1 CONTI NUED ... C. Bolting Considerations If the transmitter installation requires assembly of the process flanges , manifolds, or flange adapters, follow these assembly guidelines to ensure a tight seal for optimal performance characteristics of the transmitte rs.[...]
-
Page 6
Quick Installation Guide 00825-0100-4101, Rev EA June 2010 Rosemount 2051 6 S TE P 1 CONTI NUED ... Figure 2. T orque values for the fl ange an d f lange adapter bolts D. O-rings with Flange Adapters W ARNING Whenever the flanges or adapters are removed, vi su ally inspect the o-rings. Replace them if there are any signs of damage, such as nicks or[...]
-
Page 7
Quick Installation Guid e 00825-0100-4101, Rev EA June 2010 Rosemount 2051 7 E. Inline Gage T ransmitte r Orientat ion The low side pressure port (atmospheric referenc e) on the inline gage transmitter is located in the neck of the transmitter , behind the housing. T he vent path is 360° around the transmitter between the housing and sensor . (See[...]
-
Page 8
Quick Installation Guide 00825-0100-4101, Rev EA June 2010 Rosemount 2051 8 Figure 4. 2051 T ransmitter Electronics Board 4-20 mA HART Without LCD Meter With LCD Display 1-5 Vdc HART Low Power Without LCD Meter With LCD Display Security Alarm Alarm Security 4101_QIG_RevEA.fm Page 8 Tuesd a y, June 29, 2010 9:26 AM[...]
-
Page 9
Quick Installation Guid e 00825-0100-4101, Rev EA June 2010 Rosemount 2051 9 S TE P 4: C ONNECT THE W IRING AND P OWER Use the following steps to wire the transmitter: 1. Remove the housing cover on the FIELD TERMINALS side. 2. Connect the positive lead to the “+” termi nal (PWR/COMM) and the negative lead to the “–” terminal. Figure 5. 4[...]
-
Page 10
Quick Installation Guide 00825-0100-4101, Rev EA June 2010 Rosemount 2051 10 Figure 7. Wiring NOTE Do not connect the powered signal wiring to the test terminals. Power could damage the test diode in the test connection. Shielded twisted pa ir cable should be used for best results. Use 24 A WG or larg er wire and do not exceed 5,000 feet (1500 mete[...]
-
Page 11
Quick Installation Guid e 00825-0100-4101, Rev EA June 2010 Rosemount 2051 11 Power Supply for 4-20 mA HART T ransmitter operates on 10.5 - 42.4 Vdc. The dc power supply should provide power with less than two percent ripple. Figure 8. Load Limitati on The total resistance load is the sum of the resistance of the signal leads and the load resistanc[...]
-
Page 12
Quick Installation Guide 00825-0100-4101, Rev EA June 2010 Rosemount 2051 12 S TE P 5: V ERIFY C ONFIGURATI ON NOTE: A check (P) indicates the basic configuration parameters. At minimum, these parameters should be verified as part of the configuration and startup procedure. T able 1. Field Communicator Fast Key Se quence Function 4-20 mA HART 1-5 V[...]
-
Page 13
Quick Installation Guid e 00825-0100-4101, Rev EA June 2010 Rosemount 2051 13 S TE P 6: T RIM THE T RANSMITTE R NOTE T ransmitte rs are shipped fully calibrated per reques t or by the factory default of full scale (span = upper range limit). Zero T rim A zero trim is a single-point adjustment used for compensating mounting posit ion ef fects. When [...]
-
Page 14
Quick Installation Guide 00825-0100-4101, Rev EA June 2010 Rosemount 2051 14 S AFETY I NSTRUMENTED S YSTEMS The following section applies to 2051 tr ansmitters used in SIS applicatio ns. NOTE T ransmitter output is not safety-rated during t he following: configuration changes, multidrop, loop test. Alternative means should be used to ensure process[...]
-
Page 15
Quick Installation Guid e 00825-0100-4101, Rev EA June 2010 Rosemount 2051 15 Operation and Maintenance Proof T est and Ins pection The following proof tests are recommended. Proof test results and corrective actions taken must be documented at www .emersonprocess.com/rosemount/safety/certtechdocumentation.htm in the event that an error is found in[...]
-
Page 16
Quick Installation Guide 00825-0100-4101, Rev EA June 2010 Rosemount 2051 16 2051 Safety Failure V alues Safety accuracy: 2% (1) Safety response time- 1.5 sec Product Life 50 years – based on worst case component wear-out mechanisms – not based on wear-out process wetted materials P RODUCT C E RTIFICATIONS Approved Manufacturi ng Locations Emer[...]
-
Page 17
Quick Installation Guid e 00825-0100-4101, Rev EA June 2010 Rosemount 2051 17 HART Protocol Hazardou s Lo ca ti ons Certifications North American Certifications FM Approvals E5 Explosion-Proof for Class I, Division 1, Groups B, C, and D. Dust-Ignition-Proof for Class II, Division 1, Groups E, F , and G . Du st-Ignition-Proof for Cl ass III, Divisio[...]
-
Page 18
Quick Installation Guide 00825-0100-4101, Rev EA June 2010 Rosemount 2051 18 N1 A TEX T ype n Certification No. Baseefa08A TEX0130X II 3 G Ex nAnL IIC T4 (–40 T a +70 °C) U i = 42.4 Vdc max IP66 Special Conditions for Safe Use (X): When the optional transient protection terminal block is installed, the apparatus is not capable of withsta[...]
-
Page 19
Quick Installation Guid e 00825-0100-4101, Rev EA June 2010 Rosemount 2051 19 IECEx Certifications I7 IECEx Intrinsic Safety Certification No. IECExBAS08.0045X Ex ia IIC T4 (–60 T a +70 °C) 11 8 0 Special Conditions for Safe Use (X): When the optional transient protection terminal block is installed, the apparatus is not capable of withs[...]
-
Page 20
Quick Installation Guide 00825-0100-4101, Rev EA June 2010 Rosemount 2051 20 TIIS Certifications E4 TIIS Flame-Proof Ex d IIC T6 Inmetro Certifications E2 Flame-Proof BR-Ex d IIC T6/T5 I2 Intrinsic Safety BR-Ex ia IIC T4 GOST (Russia) Certifications IM Intrinsic Safety Ex ia IIC T4 EM Flame-Proof Ex d IIC T5/T6 China (NEPSI) Certifications E3 Flame[...]
-
Page 21
Quick Installation Guid e 00825-0100-4101, Rev EA June 2010 Rosemount 2051 21 Combinations of Certifications S tainless steel certification t ag is provided when optional appr oval is specified. Once a device labeled with multiple approval types is installed, it shou ld not be r einst alled using any other approval types. Permanently mark the appro[...]
-
Page 22
Quick Installation Guide 00825-0100-4101, Rev EA June 2010 Rosemount 2051 22 4101_QIG_RevEA.fm Page 22 Tu esday, June 29, 2010 9:26 AM[...]
-
Page 23
Quick Installation Guid e 00825-0100-4101, Rev EA June 2010 Rosemount 2051 23 4101_QIG_RevEA.fm Page 23 Tu esday, June 29, 2010 9:26 AM[...]
-
Page 24
Quick Installation Guide 00825-0100-4101, Rev EA June 2010 Rosemount 2051 24 4101_QIG_RevEA.fm Page 24 Tu esday, June 29, 2010 9:26 AM[...]