Go to page of
Similar user manuals
-
Stud Sensor
Emerson Process Management 00809-0100-4952 Rev BA
24 pages 0.43 mb -
Stud Sensor
Emerson Process Management T-SERIES
20 pages 1.89 mb -
Stud Sensor
Emerson Process Management TF396
20 pages 0.45 mb -
Stud Sensor
Emerson Process Management DVS205
4 pages 0.06 mb -
Stud Sensor
Emerson Process Management 53eA
116 pages 0.99 mb -
Stud Sensor
Emerson Process Management 396PVP
40 pages 8.15 mb -
Stud Sensor
Emerson Process Management 369P
40 pages 8.15 mb -
Stud Sensor
Emerson Process Management 381
32 pages 0.48 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Emerson Process Management T-SERIES, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Emerson Process Management T-SERIES one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Emerson Process Management T-SERIES. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Emerson Process Management T-SERIES should contain:
- informations concerning technical data of Emerson Process Management T-SERIES
- name of the manufacturer and a year of construction of the Emerson Process Management T-SERIES item
- rules of operation, control and maintenance of the Emerson Process Management T-SERIES item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Emerson Process Management T-SERIES alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Emerson Process Management T-SERIES, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Emerson Process Management service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Emerson Process Management T-SERIES.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Emerson Process Management T-SERIES item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
Micro Motion ® T -Series Sensor Inst allation Manual Inst allation Manual P/N 20002172, Rev . B July 2008[...]
-
Page 2
©2008, Micro Motion, Inc. All right s reserved. ELITE and ProLink are registered tr ademarks, and MVD and MVD Direct Connect are trademarks of Micro Motion, Inc., Boulder , Colorado. Micro Motion is a registered tra de name of Micro Motion, Inc., Boul der , Colorado. The Micro Motion and Emerson lo gos are trademarks and service ma rks of Eme rson[...]
-
Page 3
1 Before Y ou Begin Before Y ou Begin This manual describes ho w to install a Micro Motion ® T -Series sensor . The followi ng informat ion is provided in this manual: Customer service For technical assistance, phone the Micr o Motion Customer Service depa rtment: • In the U.S.A., phone 800-522-MASS (800-522-6277) (toll free) • In Canada and L[...]
-
Page 4
2 Before Y ou Begin Definitions The term MVD ™ transmitt er refers to the follo wing transmitter models: • Models 1500, 170 0, 2500, an d 2700 • Models 3500 and 3700 with sensor interf ace code 5 or 6 European installations This Micro Motion prod uct complies w ith all applicable European direct i ves when properly installed in accordance wit[...]
-
Page 5
3 Before Y ou Begin Figure 1 T -Series sensor with core processor Figure 2 T -Series sensor with integrally mounted Model 1700/2700 transmitter Approv al tag Flow direction arrow Core processor housing Calibration tag Process connection Approv al tag Flow direction arrow Core processor housing Calibration tag Process connection Model 1700/2700 tran[...]
-
Page 6
4 Determining a Location Figure 3 T -Series sensor with junction box Step 1 Determining a Location Choose a location for the sensor based on the requirements described in th is section. The foll o wing general guidelines can help you select an appropriate locatio n for the sensor . Full flow tubes For op timal performance, the sensor t ubes should [...]
-
Page 7
5 Determining a Locati on Figure 4 T -Series sensor ambient an d process temperat ure limits Hazardous area approv als may impose additional limits on ambient and process temperature. For the A TEX “T” rating, refer to the A TEX documentation shipped w ith the sensor or av ailable on the Micro Motion web site at www .micromotion.com . UL and CS[...]
-
Page 8
6 Determining a Location Maximum wiring distances If the transmitter is mounted remote ly from the sensor , the maximum di stance between the sensor and transmitter depends on cable type. See T able 2. Pipe run Micro Motion sensors d o not require a straight run of pipe upstream or downstream. Va lv e s After the sensor and transmitter ha ve been i[...]
-
Page 9
7 Orienting the Sensor Step 2 Orienting the Sensor The sensor will function proper ly in an y orientation if the sensor tube s remain f illed with process fluid. Micro Motion recommends orienting the sensor in a v ertical pipeline, with process flu id flo w ing upwa rd through the sensor (see Figure 5). Figure 5 Recommended se nsor orientation Self[...]
-
Page 10
8 Orientin g the Se nsor Figure 6 Eccentric redu cer • The gap between the ele ctronics housing and se nsor body shou ld be inspected period ically . Man ually clean this gap when necessary . • The ASME Bioprocess Equipment Standard (ASME BPE-19 97), section SC-3.12.1, includes recommendations re garding ho w to install process piping to ensure[...]
-
Page 11
9 Mounti ng the Sensor Step 3 Mounting the Sensor Use your commo n practices to minimize to rque and bendi ng load on process connections. T o reduce the risk of condensation or excessiv e moisture , the conduit opening should not point upward (if possible). The conduit opening of the junction box or core processo r can be rotated freely to facilit[...]
-
Page 12
10 Wiring Step 4 Wiring Hazardous area installations If you are installing the sensor in a hazardous location, verify that the hazardous classif ication information printed on the sensor tag matches the en vironm ent in which the sensor will be installed. Failure to comply with the requirements f or intrin sic safety in a hazardous area could resul[...]
-
Page 13
11 Wiring Figure 8 Micro Motion cable g land and he at shrink 4. For conn ection at the core processor housing, pr epare shielded cable as follo ws (for armored cable, omit steps d, e, f, and g): a. Strip 4 1/2 inches ( 114 mm) of c able jack et. b . Remove the clear wrap that is inside the cable jacket, and remo ve the filler material between the [...]
-
Page 14
12 Wiring Figure 10 Applying the heat shrink g. Position gland clamping inse rt so the interior end is flush with the heat shrink. h. Fold the cl oth shield or braid and drain wires o ve r the clamping insert and approximately 1/8 inch (3 mm) past the O-ring. Figure 11 Folding the cloth shield i. Install the gland body into the co re processor ho u[...]
-
Page 15
13 Wiring Figure 13 Connecting the wires at th e core processor 7. Reinstall and tighten the co re processor housing co ver . 8. Additional wiring instructions for the tran smitter can be found in the transmitter manual. Note: Never gr ound the 4-wire cable shield an d shield dr ain wir e(s) at the transmitter . Junction box to a 9-wire remote tr a[...]
-
Page 16
14 Grounding Step 5 Grounding The sensor can be grounde d via the piping if the joints in the pipeline are ground- bonded. If the sen sor is not grounded via the piping, connect a groun d wire to the in ternal or exter nal grounding scre w , which is located on the core processo r housing or junction box. Improper gr ounding can cause measurement e[...]
-
Page 17
15 Purge Fittings 4. Connect the supp ly of nitrogen or ar gon g as to the inlet pur ge connection or open inlet pur ge line. Leav e the outlet connec tion open. • Exercise caution to a voi d introducing dirt, moisture, rust, or other contaminants into the sensor case. • If the purge g as is heav ier than air (such as argo n), locate the inlet [...]
-
Page 18
16 Return Policy Return Policy Micro Motion procedu res must be followed when retu rning equipment. These procedures ensure le gal compliance with go vernment transpor tation agencies and help pro vide a safe working en vironment for Micro Motion employees. F ailure to follo w Micro Motion proced ures will result in your equipment being refused del[...]
-
Page 19
[...]
-
Page 20
Micro Motion Inc. USA Worldwide Headqu arters 7070 Winchester Circle Boulder , Colorado 80301 T +1 303-527-5200 +1 800-522-6277 F +1 303-530-8459 Micro Motion Europe Emerson Process Management Neonstraat 1 6718 WX Ede The Netherlands T +31 (0) 318 495 555 F +31 (0) 318 495 556 Micro Motion Japan Emerson Process Management 1-2-5, Higashi Shinagawa S[...]