Emerson Process Management TF396 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Emerson Process Management TF396, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Emerson Process Management TF396 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Emerson Process Management TF396. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Emerson Process Management TF396 should contain:
- informations concerning technical data of Emerson Process Management TF396
- name of the manufacturer and a year of construction of the Emerson Process Management TF396 item
- rules of operation, control and maintenance of the Emerson Process Management TF396 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Emerson Process Management TF396 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Emerson Process Management TF396, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Emerson Process Management service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Emerson Process Management TF396.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Emerson Process Management TF396 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    COMBINA TION pH SENSOR Instruction Manual PN 51-TF396/rev .G June 2012 MODEL TF396 with mating cable Model TF396[...]

  • Page 2

    CAUTION SENSOR/PROCESS APPLICA TION COMP A TIBILITY The wetted sensor materials may not be comp atible with process com position and operating conditions. Application comp at ibility is entirely the responsibility of the user . DANGER HAZARDOUS AREA INST ALLA TION This sensor is not Intrinsically Safe. or Explosion Proof. Installations near flammab[...]

  • Page 3

    i MODEL TF396 T ABLE OF CONTENTS MODEL TF396 COMBINA TION pH SENSOR T ABLE OF CONTENTS Section Title Page 1.0 DESCRIPTION AND SPECIFICA TIONS ................................................................. 1 1.1 Features and Applications ........................................................................................ 1 1.2 S pecifications[...]

  • Page 4

    MODEL TF396 T ABLE OF CONTENTS LIST OF FIGURES Number Title Page 2-1 Dimensional Drawing ............................................................................................... 4 2-2 Flow-Through T ee with Adapter ................................................................................ 4 2-3 Flow-Through and Insertion Installations [...]

  • Page 5

    greater than typical teflon or ceramic junctions) is made of micron-sized reference pathways allowing for ionic exchange but preventing plugging by larger particles and will continue to send a steady pH signal, even in the dirtiest of applications. The field-proven TUpH reference junction tech- nology results in greatly reduced maintenance requirem[...]

  • Page 6

    MODEL TF396 SECTION 1.0 DESCRIPTIONS AND SPECIFICA TIONS The Model TF396 TUpHFET Non-glass ISFET pH Sensor is housed in a molded reinforced polypropylene body with 1 in. MNPT threads suit able for insertion, submersion or flow through installation, or housed in a 316SST body for use with a 2.0 inch T ri-Clamp fitting. The sensor includes an ion-sel[...]

  • Page 7

    3 MODEL TF396 SECTION 2.0 INST ALLA TION SECTION 2.0 INST ALLA TION In most cases, the pH sensor can simply be installed as shipped and readings with an accuracy of ± 0.6 pH may be obtained. T o obtain greater accuracy or to ver- ify proper operation, the sensor must be calibrated as a loop with its comp atible analyzer or transmitter . 2.2.1 Flow[...]

  • Page 8

    4 MODEL TF396 SECTION 2.0 INST ALLA TION FIGURE 2-1. Dimensional Drawing DWG . NO. REV . 4TF39604 B MILLIMETER INCH FIGURE 2-2. Flow-Through T ee with Adapter (PN 915240-xx*) MILLIMETER INCH xx* Process Connection Threads 03 3/4 inch 04 1 inch 05 1-1/2 inch SENSOR CABLE WITH CONNECTOR - NOT SHOWN[...]

  • Page 9

    MODEL TF396 SECTION 2.0 INST ALLA TION DWG . NO. REV . 4TF39601 A 5 FIGURE 2-4. Model TF396 with Insertion Mounting Adapter PN 23242-02 FIGURE 2-3. Flow-Through and Insertion Inst allations DWG . NO. REV . 40396P05 C[...]

  • Page 10

    MODEL TF396 SECTION 2.0 INST ALLA TION FIGURE 2-5. Submersion Inst allations WHEN INCH AND METRIC DIMS ARE GIVEN MILLIMETER INCH DWG . NO. REV . 4TF39602 A DWG . NO. REV . 4TF39603 B 6 PN 23550-00 (WITHOUT PREAMP)[...]

  • Page 11

    7 MODEL TF396 SECTION 2.0 INST ALLA TION FIGURE 2-7. Jet Spray Cleaner PN 12707-00 MILLIMETER INCH LOW FLOW CELL PN 24091-00 Inlet and outlet connections are stainless steel and take 1/4-inch OD tubing. Flow cell is polycarbonate with 1/4-inch FNPT fittings. WETTED MA TERIALS: BODY - ACRYLIC NUT - CPVC FITTINGS - 316 SST SEALS - BUNA N FLOW CELL RA[...]

  • Page 12

    8 Wiring. The Model TF396 has a mating cable with built-in preamplifier and is offered with a shielded cable. The cable should be handled carefully and kept dry and free of corrosive chemicals at all times. Extreme care should be used to prevent it from being twisted, damaged or scraped by rough, sharp edges or surfaces. Please refer to Figures 3-1[...]

  • Page 13

    9 MODEL TF396 SECTION 3.0 WIRING - MODEL TF396 FIGURE 3-1. Wiring to Model 1055. DWG . NO. REV . 14055103 B DWG . NO. REV . 41055102 B[...]

  • Page 14

    10 MODEL TF396 SECTION 3.0 WIRING - MODEL TF396 FIGURE 3-2. Wiring to Model 54e. DWG . NO. REV . 40054E04 A FIGURE 3-2. Wiring to Models 3081, 4081, & 5081. DWG . NO. REV . 40508114 A[...]

  • Page 15

    Recommended pH Sensor St andardization: For maximum accuracy , the sensor can be standardized online or with a process grab sample after a buf fer calibra- tion has been performed and the sensor has been condi- tioned to the process. S t andardization account s for the sensor junction potential and other interferences. S t andardization will not ch[...]

  • Page 16

    12 MODEL TF396 SECTION 5.0 MAINTENANCE The Model TF396 Sensors require minimum mainte- nance. The sensor should be kept clean and free of debris and sediment at all times. The frequency of cleaning by wiping or brushing with a soft cloth or brush is determined by the nature of the solution being measured. The sensor should be removed from the proce[...]

  • Page 17

    13 MODEL TF396 SECTION 6.0 RETURN OF MA TERIAL SECTION 6.0 RETURN OF MA TERIAL 6.1 GENERAL. T o expedite the repair and return of instruments, prop- er communication between the customer and the fac- tory is important. Before returning a product for repair , call 1-949-757-8500 for a Return Materials Authorization (RMA) number . 6.2 W ARRANTY REP A[...]

  • Page 18

    FROM: RETURN BILL T O: _____________________________ _____________________________ _____________________________ _____________________________ _____________________________ _____________________________ _____________________________ _____________________________ _____________________________ CUSTOMER/USER MUST SUBMIT MA TERIAL SAFETY SHEET (MSDS) O[...]

  • Page 19

    W ARRANTY Seller warrants that the firmware will execute the programming instructions provided by Seller , and that the Goods manufactured or Services provided by Seller will be free from defects in materials or workmanship under normal use and care until the expira- tion of the applicable warranty period. Goods are warranted for twelve (12) months[...]

  • Page 20

    Credit Cards for U.S. Purchases Only . The right people, the right answers, right now . ON-LINE ORDERING NOW A V AILABLE ON OUR WEB SITE http://www .rosemountanalytical.com Specifications subject to change without notice. 8 Emerson Process Management 2400 Barranca Parkway Irvine, CA 92606 USA T el: (949) 757-8500 Fax: (949) 474-7250 http://www .ros[...]