Go to page of
Similar user manuals
-
TV Converter Box
Emerson TCL
78 pages 0.82 mb -
TV Converter Box
Emerson 5081T-FF/FI
24 pages 0.97 mb -
TV Converter Box
Emerson DCS4830
17 pages 0.67 mb -
TV Converter Box
Emerson 951C
64 pages 1.8 mb -
TV Converter Box
Emerson HAS8xE-IM-ATEX
54 pages 2.09 mb -
TV Converter Box
Emerson 5400
42 pages 0.92 mb -
TV Converter Box
Emerson 5300
42 pages 0.92 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Emerson 5081T-FF/FI, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Emerson 5081T-FF/FI one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Emerson 5081T-FF/FI. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Emerson 5081T-FF/FI should contain:
- informations concerning technical data of Emerson 5081T-FF/FI
- name of the manufacturer and a year of construction of the Emerson 5081T-FF/FI item
- rules of operation, control and maintenance of the Emerson 5081T-FF/FI item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Emerson 5081T-FF/FI alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Emerson 5081T-FF/FI, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Emerson service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Emerson 5081T-FF/FI.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Emerson 5081T-FF/FI item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
Model 5081T -FF/FI Instruction Sheet PN 51A-5081T -FF/FI/rev .A November 2005 Y our purchase from Rosemount Analytical, Inc. has result- ed in one of the finest instruments available for your p ar- ticular application. These instrument s have been designed, and tested to meet many national and interna- tional standards. Experience indicates that it[...]
-
Page 2
PHYSICAL SPECIFICA TIONS HOUSING: Epoxy-polyester painted over low-copper alu- minum. Neoprene O-rings on cover . 160.5 mm x 175.3 mm x 161.3 mm (6.3 in. x 6.9 in. x 6.4 in.) DIAMETER: 155.4 mm (6.1 in.) ELECTRICAL CONDUIT OPENINGS: 3/4 in. FNPT POWER SUPPL Y AND LOAD: A power supply voltage of 9 Vdc to 32 Vdc at 22 mA is required; Intrinsically Sa[...]
-
Page 3
3 3 MODEL 5081T -FF/FI SPECIFICA TIONS TRANSMITTER DISPLA Y DURING CALIBRA TION AND PROGRAMMING (FIGURE 1) 1. Continuous display of conductivity , % concentration, or custom reading. 2. Units: µS/cm, mS/cm, ppm, %, or none. 3. Current menu appears here. 4. Submenus, prompts, and diagnostic readings appear hear . 5. Commands available in each subme[...]
-
Page 4
4 U1 7 :! <[9:1 -E< / ! 922<U '"*#=22 /1[[! /9P<U <Q2U 4-SG U<[9:1 2D>[=T '""" 25.0C 12.00mA CAL key PROG key DIAG key HOLD key Model 5081T -FF/FI Process Display Screen µS/cm /-[5ES-U1 /1[[! /9P<U <1P<9S! " U1 7 :! -G6 U1 7 : G5<:[-A <1U>:! /V<= G12->[= PROGRAM Proc[...]
-
Page 5
MODEL 5081T -FF/FI DEF AUL T SETTINGS V ARIABLE NAME MNEMONIC F ACTOR Y SETTINGS CUSTOMER SETTINGS Program Menu T emperature UH OR Auto temperature compensation UDVUQ on ___________ Manual temperature UODP 25.0°C (overridden by auto) ___________ T emperature compensation algorithm /97: ( [LPHDS or P9P1 ) LInEAr ___________ Display GLTRND Y Measure[...]
-
Page 6
6 MODEL 5081T -FF/FI WIRING WIRING Wire sensor as shown below in Figure 2. Keep sensor wiring separate from power wiring. For best EMI/RFI protection, use shielded output signal cable in an earth-grounded metal conduit. Refer to the sensor instruction manual for more det ails. FIGURE 2. Wiring Model 5081T -FF/FI[...]
-
Page 7
7 7 MODEL 5081T -FF/FI WIRING WIRING THROUGH A JUNCTION BOX The sensor can be wired to the analyzer through a remote junction box (PN 23550-00). Wire the extension cable and sensor cable point-to-point. Refer to the sensor instruction manual for more details. Factory-terminated (PN 23747-00) and unterminated (PN 9200275) connecting cable are availa[...]
-
Page 8
8 MODEL 5081T -FF/FI INST ALLA TION INST ALLA TION UNP ACKING AND INSPECTION Inspect the shipping container . If it is damaged, cont act the shipper immediately for instructions. Save the box. If there is no apparent damage, unp ack the container . Be sure all items shown on the packing list are present. If items are missing, notify Rosemount Analy[...]
-
Page 9
9[...]
-
Page 10
10[...]
-
Page 11
11[...]
-
Page 12
1 1 2 2[...]
-
Page 13
13[...]
-
Page 14
1 1 4 4 FM A 5/6/04 J. FLOCK 5/6/04 J. FLOCK .140 ±. 0 0 5 1.30 ±. 0 2 .650 ±. 0 15 .125 2.180 ±. 0 0 5 2.56 ±. 0 2 .120 ±. 0 15 Ø .125 R .25 5-6-04 89 33 4 4 FINISH:SILKSCREEN BLACK EPOX Y PAINT (BAKED). 5081-T-FI-67 MODEL 5081-T-FI HARDNES S BRINEL L 190 . BE ANNEALED & PASSIVATED. MAX IMUM STEEL .015+/-.005 THICK. MATERIAL TO 1 MATERI[...]
-
Page 15
1 1 5 5 5/6/04 J. FLOCK 5/6/04 J. FLOCK 70°C MA X CLASS III, DI V 1 CLASS II, DIV 1, GPS E-G CLASS I, DIV 1, GPS B-D HAZARDOU S AREA 3 R T D C O M 6 R C V S H L D 7 R C V C O M 8 R C V 9 D R V S H L D 1 0 D R V C OM 2 R T D S H L D 5 R T D I N 1 2 N C 1 3 N C 4 R T D S E N S E 1 R E S E R V E D 1 5 H T / F F ( - ) 1 6 H T / F F ( + ) 1 4 N C 1 1 D[...]
-
Page 16
1 1 6 6 FM B La, Lt OR Lo; OR Lc/Rc (La/Ra OR Lo/Ro) AND Li/Ri (L a/Ra OR Lo /Ro) 1. INSTALLATION SHOULD BE IN ACCORDANC E W ITH ANSI /ISA RP12.06 "INSTALLATION OF INTRIN SICALLY SAFE SYSTEMS FOR H AZARD OUS (C LASSIFIED) LOC ATIONS" (EXCE PT CHAPTER 5 FOR FISCO INSTALLATIONS) AND THE NATIONAL ELECTRICAL CODE (A NSI/NFPA 70) SECTIONS 504 [...]
-
Page 17
1 1 7 7 THIS DOCUMENT IS CERTIFIED BY REV REV REV REV REV REV REVISIONS NOT PERMITTED W/O AGENCY APPROVAL DIMENSIONS ARE IN INC HES REMOVE BURRS & SHA RP EDGES .020 MAX MACHINED FILLE T RADII .020 MAX - ITEM PART NO DESCRIPTION QT Y SCALE SIZE REV DW G NO BILL OF M AT ERIAL MATERIAL FINIS H DRAW N CHECKED PROJECT ENGR APVD NOTES: UNLESS OTHERW [...]
-
Page 18
1 1 8 8 Rosemount Analytical, Uniloc Divisi on 2400 Barran ca Pkwy Irvine, CA 92 606 UNLESS OTHERWISE SPECIFIED DIMENSIO NS ARE IN INCHES REMOVE BURRS & S HARP EDGES .02 0 MAX MACHINED F ILLET RADII .0 20 MAX FINISH MATERIAL PROJECT ENGR A PVD SIZE DWG NO. REV TITLE SCALE TYPE This document contains information propriet ary to Rosemount Analyti[...]
-
Page 19
1 1 9 9 9241514-01/ A DIME NSIONS ARE IN I NCHES REMOVE BURRS & SHA RP EDGES .020 MAX MACHINED FILLE T RADII .020 MA X - ITEM PART NO DESCRIPTION QT Y SCALE SIZE REV DW G NO BILL OF M AT ERIAL MATERIAL FINIS H DRAW N CHECKED PROJECT ENGR APVD NOTES: UNLESS OTHERW ISE SPECIFIED REV ECO NO RELEASE DATE LTR ECO REVISIONS DESCRIPTION BY DATE CHK Th[...]
-
Page 20
2 2 0 0 Rosemount Analytical, Uniloc Division 2400 Ba rranca Pk wy Irvine, CA 9 2 606 UNLESS OTHERWISE SPECIFIED DIMENSIONS ARE IN INCHES REMOVE BURRS & SHARP EDGES .020 MAX MACHINED FILLET RADII .020 MAX FINISH MATER IAL PROJECT ENGR APV D SIZE DWG NO. REV TITLE SCALE TYPE This document contains information proprietary to Rosemount Analytical,[...]
-
Page 21
2 2 1 1 OVERVIEW This section gives general procedures for routine maintenance of the 5081-T transmitter . The transmitter needs almost no routine maintenance. TRANSMITTER MAINTENANCE Periodically clean the transmitter window with household ammonia or glass cleaner . The detector for the infrared remote controller is located behind the window at th[...]
-
Page 22
2 2 2 2 Replacement Part s for Model 5081-T -FF/FI T ransmitter Location in Shipping drawing PN Description Weight 1 23992-07 PCB stack consisting of the CPU (p art 3) and analog (part 4) boards, 1 lb/0.5 kg display board is not included, CPU and analog boards are factory- calibrated as a unit and cannot be ordered separately 2 23638-01 LCD display[...]
-
Page 23
2 2 3 3 QUICK-ST ART 1. On the Remote, press PROG , NEXT , ENTER. 2. Use the arrow buttons to select COnduc (conductivity), nAOH (Sodium Hydroxide 0-15%), HCL (Hydrochloric Acid 0-16%), H2SO4L (Sulfuric Acid 0-30%), H2SO4H (Sulfuric Acid 95-99.99%), or CuSt (custom curve) mode. Press ENTER. If you chose CuSt , continue with step 3. If you chose COn[...]
-
Page 24
Credit Cards for U.S. Purchases Only . The right people, the right answers, right now . ON-LINE ORDERING NOW A V AILABLE ON OUR WEB SITE http://www .raihome.com Specifications subject to change without notice. Emerson Process Management Liquid Division 2400 Barranca Parkway Irvine, CA 92606 USA T el: (949) 757-8500 Fax: (949) 474-7250 http://www .r[...]