Go to page of
Similar user manuals
-
Fan
Emerson CF4801AP00
16 pages 0.42 mb -
Fan
Emerson CF4801VNB00
16 pages 0.42 mb -
Stereo System
Emerson ES1
31 pages 0.55 mb -
Flat Panel Television
Emerson LC195EMX
115 pages 26.1 mb -
Pacemaker
Emerson MMI-20011276
78 pages 0.99 mb -
Satellite Radio
Emerson 3350
24 pages 2.08 mb -
Ice Maker
Emerson IM93B
9 pages 3.11 mb -
Fan
Emerson CF755BZH05
12 pages 0.18 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Emerson C199, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Emerson C199 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Emerson C199. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Emerson C199 should contain:
- informations concerning technical data of Emerson C199
- name of the manufacturer and a year of construction of the Emerson C199 item
- rules of operation, control and maintenance of the Emerson C199 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Emerson C199 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Emerson C199, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Emerson service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Emerson C199.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Emerson C199 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
1 99 Series Rev . 3 / 99 USER MANUAL FOR THE METRO C199 AND FL199 SERIES INSULA TED HEA TED CABINETS Recommended Food Holding Guidelines Listed on pages 5 & 6. ® ® InterMetro Industries Corporation Wilkes-Barre, P A 18705 570-825-2741[...]
-
Page 2
1 I. INTRODUCTION A. IDENTIFYING YOUR CABINET Y our cabinet assembly has been shipped in two cartons. The first car ton contains the cabinet with module. The other carton contains the slide racks. There ar e several component numbers which you may want to recor d for future r eference: the cabinet model number , the module model number along with t[...]
-
Page 3
2 B. FEA TURES — ALL MODELS In order to utilize your new cabinet to its full potential, take a minute to identify the following features which have been provided for your convenience. • The module has been placed at the base of the cabinet for easy accessibility and efficient operation. • Clearly-marked control panel for easy viewing and allo[...]
-
Page 4
3 CVSN/-T/-H — Model V (adjustable) The Model V Slide Rack can be installed in either an inboard or outboar d position. Center spacing on slides can be either 3" or 4 1 / 2 ". Slides can be r emoved by lifting upward and sliding the rivet heads out of the keyhole slots. T o install, select spacing, inser t the rivet heads into the keyho[...]
-
Page 5
4 It is not necessary at the end of the operating day to disrupt the TEMPERA TURE setting in order to turn the unit OFF . By switching the POWER switch to OFF , the unit is no longer operating. By switching the POWER switch to ON when resuming operations, the cabinet setting will be at the previous set point. C2. FL2000 HIGH HUMIDITY HOLDING MODULE[...]
-
Page 6
5 9. T o install the module, reverse step 8. When installing the module into the cabinet, the cord must be fed thr ough the opening in the cabinet back panel. Be car eful that the seals on the side of the module go inside the module slides. T o descale the humidity generator: T o clean the humidity generator , use a commercially available descaling[...]
-
Page 7
6 III. FOOD HOLDING GUIDELINES A. HM2000/HM15L W Recommended Food Holding Guidelines Food Product Covered/Uncovered T emperature Setting °F* Baked Fish Uncovered 175 Baked Potatoes Uncovered 180 Biscuit Uncovered 180 Broccoli Covered 170-175 Chicken Nuggets Uncovered 175 Corn on the Cob Covered 170-175 Croissants Uncovered 175 Egg Patties Covered [...]
-
Page 8
7 I V . CLEANING INSTRUCTIONS CAUTION A T NO TIME SHOULD THE MODULE OR CABINET BE W ASHED OR FLOODED WITH W A TER OR LIQUID SOLUTION. NEVER STEAM CLEAN. SEVERE DAMAGE OR ELECTRICAL HAZARD COULD RESUL T . 1. T ur n off master switch. 2. Disconnect the unit from its power sour ce. W ARNING ALLOW THE UNIT TO COOL BEFORE CLEANING, AS THE INTERIOR OF TH[...]
-
Page 9
8 16 13 10 9 23 25 1 19 22 8 2 5 28 VI. REPLACEMENT P ARTS, PROCEDURES AND WIRING DIAGRAMS A. CABINET — ALL MODELS Refer to the Cabinet Replacement Parts Diagram on next page to identify the replacement parts. C199 Series Cabinet Replacement Parts Diagram (see page 9 for parts list)[...]
-
Page 10
9 CABINET REPLACEMENT P AR TS LIST ( 1 / 2 & 3 / 4 height cabinet parts not shown) Item No. Part No. Description 1 RPC199P-1102T T op Door 2 RPC199P-1102B Bottom Door 3 RPC199HP-1102 Door ( 1 / 2 height cabinet) 4 RPC199TP-1102 Door ( 3 / 4 height cabinet) 5 RPC06-809 Gasket (double door units) 6 RPC06-811 Gasket ( 1 / 2 height cabinet) 7 RPC06[...]
-
Page 11
10 B. MODULE Y our module has been designed to be user - servicable, assuming a basic knowledge of the operation of electrical devices. This section has been written to guide the user step by step, and in layman ’ s ter ms, through the dismantling and servicing of the module. Before attempting to service your module, read the appr opriate Module [...]
-
Page 12
11 Holding Module Replacement Parts Diagram REPLACEMENT PARTS LIST Item No. Part No. Description 1 RPC13-017 Power Cord — 15 AMP (HM15L W only) 2 RPC13-083 Strain Relief — 15 AMP (HM15L W only) 3 RPC06-313 Thermostat Knob 4 RPHM20-P AN Water Pan 5 RPC13-127 Power Switch 6 RPC13-129 T emperature Thermostat 7 RPC13-105 Y ellow Indicator Light 8 R[...]
-
Page 13
12 HOLDING WIRING DIAGRAM VI. WIRING SCHEMA TICS[...]
-
Page 14
13 FL2000 High Humidity Module Replacement Parts Diagram AIR DUCT 3 6 4 19 20 19 18 AIR INT AKE COVER 17 5 CONTROL P ANEL THERMOST A T BULB THERMOMETER SENSOR TOP P AN 9 10 DEFLECTOR PLA TE 11 12 16 COVER 23 15 1 2 14 25 24 20 21 22 8 7 13 REPLACEMENT PARTS LIST Item # Part # Description 1 RPC13-099 Power Cord — 20 AMP 2 RPC13-098 Strain Relief ?[...]
-
Page 15
14 FL2000 HIGH HUMIDITY MODULE WIRING DIAGRAM WIRE NUT (TYP) BLACK 4 6 1 6 5 4 3 2 0 1 2 8 - + 6V DC OUTPUT POWER SUPPLY THERMOMETER TRANSFORMER 24V AC PERCENTAGE TIMER SWITCHING 110V AC 24V AC RELAY 100K POTENTIOMETER CAPILLARY SENSOR THERMOSTAT HEAT TIMER PERCENTAGE 24VAC LOAD + - RED BLUE YELLOW WHITE BLACK BLACK BLACK WHITE WHITE SWITCH CUT-OUT[...]
-
Page 16
15 CUT ALONG DOTTED LINE CUT ALONG DOTTED LINE CUSTOMER INFORMA TION 1. Which one of the following best describes your establishment? a. ❑ Full Service Restaurant b. ❑ Fast Food Restaurant c. ❑ Hotel/Motel d. ❑ Hospital/Nursing Home e. ❑ College/University f. ❑ School g. ❑ Employee Feeding h. ❑ Other Thank you for purchasing a Metro[...]
-
Page 17
FOLD HERE — DO NOT DET ACH ST APLE HERE ST APLE HERE BUSINESS REPL Y MAIL FIRST -CLASS PERMIT NO. 121 WILKES-BARRE, PA NO POST AGE NECESSARY IF MAILED IN THE UNITED ST A TES POST AGE WILL BE PAID BY INTERMETRO INDUSTRIES CORPORA TION ATTN: CUSTOMER SER VICE P O BOX A WILKES-BARRE P A 1870 5-9968 ST APLE HERE[...]
-
Page 18
W arranty W ARRANTY , EXCLUSION OF W ARRANTIES AND LIMIT A TION OF LIABILITY . InterMetro Industries Cor poration (hereinafter ref erred to as “Seller”) warrants to the original purchaser that all products in its catalog, or custom products, delivered hereunder will be free from def ects in workmanship and mater ial. THE FOREGOING W ARRANTY IS [...]
-
Page 19
InterMetro Industries Corporation North Washington Str eet, Wilkes-Barr e, P A 18705 For Product Information Call: 1-800-433-2232 Visit Our W eb Site: www .metro.com L01-386 Rev . A 03 / 03 Information and specifications are subject to change without notice. Please confirm at time of order . ®[...]