Emerson CF452GBZ00 manual

1
2
3
4
5
6
7
8
9
10
11
12

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Emerson CF452GBZ00, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Emerson CF452GBZ00 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Emerson CF452GBZ00. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Emerson CF452GBZ00 should contain:
- informations concerning technical data of Emerson CF452GBZ00
- name of the manufacturer and a year of construction of the Emerson CF452GBZ00 item
- rules of operation, control and maintenance of the Emerson CF452GBZ00 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Emerson CF452GBZ00 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Emerson CF452GBZ00, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Emerson service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Emerson CF452GBZ00.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Emerson CF452GBZ00 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Part No. F40BP73980001 Form No. BP7398-1 U.L. Model No.: CF452 READ AND SA VE THESE INSTRUCTIONS 52” Ceiling F an Owner's Manual CF452AW00 - Summer W hite CF452AP00 - Antique P ewter CF452BS00 - Br ushed Steel CF452GBZ00 - Gilded Br onze CF452GES00 - Golden Espr esso CF452ORB00 - Oil R ubbed Br onze Model Number s CARRERA BELLA ™ Net W eig[...]

  • Page 2

    WARNING: To avoid fire, shock, and serious personal injury, follow these instructions. Safety Instructions 1. Read your owner’s manual carefully and keep it for future reference. 2. Before servicing or cleaning unit, switch power off at service panel and lock service panel disconnecting means to prevent power from being switched on accidentally. [...]

  • Page 3

    1. Check to see that you have received the following parts: NOTE: If you are uncertain of part description, refer to exploded view illustration. a. Fan motor assembly b. One switch housing assembly c. One ceiling cover d. Five blade flanges e. One hanger ball/4.5” downrod assembly f. One hanger bracket g. One coupling cover h. Five fan blades i. [...]

  • Page 4

    2. Mount blade flanges to fan blades using three M5 x 6mm washer head blade screws (Figure 2). NOTE: Take care not to scratch fan housing when installing blades. 4 1. Rotate the motor hub to align the hub motor area over each of the five shipping retainers. One by one unscrew each of the five screws and discard screws and shipping retainers (Figure[...]

  • Page 5

    SWITCH HOUSING MOUNTING SCREW (3) SWITCH HOUSING ASSEMBL Y MOTOR CONNECTOR SWITCH HOUSING CONNECTOR 5 Figure 4 4. The blade flanges have an interlocking feature that must be fully engaged before tightening the screw. Make sure all the flanges are properly engaged and then tighten the flange screws. If one of the flanges does not seat properly on th[...]

  • Page 6

    CEILING COVER HANGER BALL PIN SETSCREW Figure 9 It is critical that the pin in the hanger ball is properly installed and the setscrew securely tightened. Failure to verify that the pin and setscrew are properly installed could result in the fan falling. WARNING ! 12. The fan comes with blue, black and white leads that are 80” long. Before install[...]

  • Page 7

    7 Ho w to Hang Y our Ceiling F an The fan must be hung with at least 7' of clearance from floor to blades (Figure 10). A T LEAST 7' CEILING FLOOR Figure 10 WARNING ! The outlet box and joist must be securely mounted and capable of supporting at least 50 lbs. Use only a U.L. outlet box listed as “Acceptable for Fan Support”. WARNING ! [...]

  • Page 8

    8 U.L. Model No.: CF452 If you feel that you do not have enough electrical wiring knowledge or experience, have your fan installed by a licensed electrician. 1. Connect the green grounding lead from the hanger ball and the green grounding lead from the hanger bracket to the grounding conductor of supply (this may be a bare wire or wire with green c[...]

  • Page 9

    1. Restore electrical power to the outlet box by turning the electricity on at the main fuse box. 2. Check the operation of the fan by gently pulling on the pull chain switch. 3. All fans are shipped from the factory with the reversing switch positioned “down” to circulate air downward. If airflow is desired in opposite direction, turn your fan[...]

  • Page 10

    10 WARNING: For your own safety, turn off power at fuse box or circuit breaker before trouble shooting your fan. T rouble Shooting TROUBLE PROBABLE CAUSE SUGGESTED REMEDY 1. Fan will not start. 1. Fuse or circuit breaker blown. 1. Check main and branch circuit fuses or circuit breakers. 2. Loose power line connections to the fan, 2. Check line wire[...]

  • Page 11

    11 20 6 5 9 13 12 19 16 10 14 17 18 21 7 8 11 1 2 3 15 4 U.L. Model No.: CF452 Before discarding packaging material, be certain all parts have been removed. HOW TO ORDER REP AIR P ARTS WHEN ORDERING REPAIR PARTS, ALWAYS GIVE THE FOLLOWING INFORMATION: • PART NUMBER • PART DESCRIPTION • NAME OF ITEM • MODEL NUMBER For repair parts, phone 1-8[...]

  • Page 12

    U.L. Model No.: CF452 Part No. F40BP73980001 Printed in China 07/09 Form No. BP7398-1 Air Comfort Products DIVISION OF EMERSON ELECTRIC CO. 8100 W. Florissant • St. Louis, MO 63136 LIMITED WARRANTY What The Warranty Covers: This warranty covers the motor and the other components and accessories of your Emerson ceiling fan against all defects in w[...]