Go to page of
Similar user manuals
-
Fan
Emerson CF690CK00
12 pages 0.28 mb -
Fan
Emerson CF252CRM00
20 pages 0.29 mb -
Fan
Emerson CF705SAW02
8 pages 0.12 mb -
Fan
Emerson CF787GBZ00
12 pages 0.27 mb -
Fan
Emerson CF770TG01
8 pages 0.17 mb -
Fan
Emerson CF772ORB00
16 pages 0.29 mb -
Fan
Emerson CF905ORB00
16 pages 0.39 mb -
Fan
Emerson CF704SAW02
8 pages 0.12 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Emerson CF705AB04, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Emerson CF705AB04 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Emerson CF705AB04. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Emerson CF705AB04 should contain:
- informations concerning technical data of Emerson CF705AB04
- name of the manufacturer and a year of construction of the Emerson CF705AB04 item
- rules of operation, control and maintenance of the Emerson CF705AB04 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Emerson CF705AB04 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Emerson CF705AB04, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Emerson service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Emerson CF705AB04.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Emerson CF705AB04 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
Part No. F40BP72240007 Form No. BP7224-7 U.L. Model No.: CF705 READ AND SA VE THESE INSTRUCTIONS Model No. CF705AB04 CF705AGW04 CF705A W04 CF705BC04 CF705BS04 CF705BZH04 CF705CK04 52” NOR THWIND ® Net Weight: 16.5 Lbs. Ceiling Fan Owner's Manual LIMITED WARRANTY What The Warranty Covers: This warranty covers the motor and the other componen[...]
-
Page 2
2 U.L. Model No.: CF705 W ARNING ! WARNING: To avoid fire, shock, and serious personal injury, follow these instructions. Safety Instructions 1. Read your owner’s manual carefully and keep it for future reference. 2. Before servicing or cleaning unit, switch power off at service panel and lock service panel disconnecting means to prevent power fr[...]
-
Page 3
1. Check to see that you have received the following parts: NOTE: If you are uncertain of part description, refer to exploded view illustration. a. Fan motor assembly b. One switch housing assembly c. Five fan blades d. One ceiling cover e. Five blade flanges f. One hanger ball/downrod assembly g. One hanger bracket h. One loose parts bag containin[...]
-
Page 4
NOTE: Take care not to scratch fan housing when installing blades. NOTE: Remove and discard the four shipping spacers and screws from the motor hub. 7. Turn the fan assembly upside down in preparation for mounting the fan blade assemblies. 8. Rotate the motor hub until the flange screw hole is next to the cutout in the switch housing plate. Attach [...]
-
Page 5
5 U.L. Model No.: CF705 11. Remove the three switch housing mounting screws (Figure 4) from the switch housing plate. Position the switch housing assembly on the switch housing plate and align the holes in the switch housing assembly with the holes in the plate. Secure the switch housing assembly by installing the three mounting screws (Figure 5). [...]
-
Page 6
6 U.L. Model No.: CF705 OUTLET BOX HANGER BRACKET HANGER BALL/ DOWNROD ASSEMBL Y Figure 3 NOTE: CEILING COVER, SUPPL Y WIRES AND F AN WIRES OMITTED FOR CLARITY . Figure 8 2. Carefully lift the fan and seat the hanger ball/ downrod assembly on the hanger bracket that was just attached to the outlet box (Figure 8). Be sure the groove in the ball is l[...]
-
Page 7
5. Secure the ceiling cover in place by sliding lock- washers over the threaded studs and installing the two knurled knobs (supplied). (Figure 10.) Tighten the knurled knobs securely until the ceiling cover fits snugly against the ceiling and the hole in the ceiling cover is clear of the downrod. Your fan is now wired to be turned on and off from t[...]
-
Page 8
1. Restore electrical power to the outlet box by turning the electricity on at the main fuse box. 2. Check the operation of the fan by gently pulling on the pull chain switch. All fans are shipped from the factory with the revers- ing switch positioned “down” to circulate air downward. If airflow is desired in opposite direc- tion, turn your fa[...]
-
Page 9
9 U.L. Model No.: CF705 T r ouble Shooting TROUBLE PROBABLE CAUSE SUGGESTED REMEDY 1. Fan will not start. 1. Fuse or circuit breaker blown. 1. Check main and branch circuit fuses or circuit breakers. 2. Loose power line connections to the fan, or loose 2. Check line wire connections to fan and switch switch wire switch wire connections in the switc[...]
-
Page 10
18 10 9 16 17 15 13 12 8 7 6 4 5 1 2 3 11 14 Repair Par ts Before discarding packaging material, be certain all parts have been removed. HOW TO ORDER REP AIR P ARTS WHEN ORDERING REPAIR PARTS, ALWAYS GIVE THE FOLLOWING INFORMATION: • PART NUMBER • NAME OF ITEM • PART DESCRIPTION • MODEL NUMBER The model number of your Fan will be found on a[...]
-
Page 11
11 U.L. Model No.: CF705 Key Model No. N o. Description CF705WW04 CF705PB04 CF705AB04 CF705BS04 CF705SCB04 CF705HTW04 * Hanger Ball Assembly, 760750-3 760750-1 760750 760750-24 760750-36 760750-34 Consisting of: 1 Hanger Bracket — — — — — — 2 Hanger Ball — — — — — — 3 Downrod — — — — — — * Parts Bag Containing: 7[...]
-
Page 12
Air Comfort Products &+8+5+101('/'4510'.'%64+%%1 9(NQTKUUCPVć5V.QWKU/1 Part No. F40BP72240007 Printed in China 09/07 Form No. BP7224-7 U.L. Model No.: CF705[...]