Go to page of
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Eminent EM8622, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Eminent EM8622 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Eminent EM8622. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Eminent EM8622 should contain:
- informations concerning technical data of Eminent EM8622
- name of the manufacturer and a year of construction of the Eminent EM8622 item
- rules of operation, control and maintenance of the Eminent EM8622 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Eminent EM8622 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Eminent EM8622, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Eminent service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Eminent EM8622.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Eminent EM8622 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
EM8622 Wireless Control Panel[...]
-
Page 2
2 | ENGLISH EM8622 - Wireless Control Panel Table of contents 1.0 Introduction ...... ...... ......... ...... ..... ...... ......... ...... ...... ..... ......... ...... ...... ...... ........ ...... .. 3 1.1 Packing content s ...... ......... ...... ...... ..... ......... ...... ...... ...... ........ ...... ...... ...... ...... .... 3 1.2 Control[...]
-
Page 3
3 | ENGLISH 1.0 Introduction Congratulations w ith the purchase of thi s high-quality Eminent product ! This prod uct has undergone ex tensive testing by Eminen t’s technical ex perts. Should you experience any pro blems with this pro duct, you are covered by a five- year Eminent warranty. Please keep this manual and the receipt in a safe place. [...]
-
Page 4
4 | ENGLISH 1.3 Control panel ins ide 2.0 Installation Install the batteries and mount the control panel on the door fra me or the w all before use. Battery contact, plea se check positive and negative terminals Battery compartment Tamper switch Wired cable connection Red wire = + 12V Black wire = - GND[...]
-
Page 5
5 | ENGLISH 1) Remove the screw and open the ca se 2) Install the batteries ac cording to th e positive and negative sign s (Re move the insulating strip be fore the first use) 3) Mount the backcover on the door fr ame or wall 4) Close the case and replace the sc rew Note : Opening the cover will trigger the tamp er switch ! You can disar m it by e[...]
-
Page 6
6 | ENGLISH If there is an intru sion the alarm sy stem will be trigger ed, the siren w ill hoot and the alarm sy stem will send an SMS and au to dial to pre-stored phone numbers to notify u sers. Note : When an en try delay is set, the external control pane l will NOT warn you with an audio signal when a sensor is t riggered. Only the alarm system[...]
-
Page 7
7 | ENGLISH 3.2.2 Using RFID Tag to disarm If direct disar m by RFID tag is disa bled (this is the defaul t power saving mode when using batteries), u ser needs to press [* ] to wake up the control panel and then put RFID tag close to the reade r to di sarm the alar m system.. When the pow er saving function is disabled, user can put the RFID t ag [...]
-
Page 8
8 | ENGLISH 3.2.4 Emergency Call When the control panel is in SOS Speed Dial mode, u ser just holds the [SOS] key for 3 seconds, the LED indicator flashes once, the con trol panel beeps once, and the alarm system alar ms immediately. When the control panel is not in SOS Speed Dial mode , user needs to inpu t user code or admin code befor e holding [...]
-
Page 9
9 | ENGLISH 4.0 Connect to the alarm sy stem Note : The default admin code is : 1 23456. See chapter “Ch ange Ad min Code” to change it. Note : The default user code is : 12 34. See chapter “Change User Code” to change it. Make sure the alar m system is in connection state (pres s code on alarm syste m and press the me mo button). Input the[...]
-
Page 10
10 | ENGLISH 3. Put the RFID tag close to the RFID re ader. If one beep is heard the connecting is successful. When 2 beeps are hea rd, the RFID tag w as already connected to the control panel. To remove all conne cted RFID tag s, input the admin code followed by the # button. Press and hold down the 9 button for six seconds. All RFID tags are clea[...]
-
Page 11
11 | ENGLISH 6.0 Settings Before changing the settings of th e control panel, the control panel sho uld be in “setup-state”. 6.1 Enter Setup-s tate Note : The default adm in code is : 123456 Input the admin code fol lowed by the [#] button to w ake up the control panel. Press [3] to enter the se tup-state. The LED indicator w ill be on. Note : [...]
-
Page 12
12 | ENGLISH After setting a delay time, press the [Arm] button on the con trol pan el. The control panel will send the Arm command to the alarm system afte r the delay time you set in the control panel . Note : This setting will not apply to the Hom e mode. If both the control panel and the alarm system ha ve a delay time set, the a ctual delay ti[...]
-
Page 13
13 | ENGLISH 6.3.1 Disable SO S code Enter Setup-state and input : When one beep i s heard and the L ED indicator keeps on for 10 seconds, the setup is successful. 6.3.2 Enable SOS code Enter Setup-state and input : When one beep i s heard and the L ED indicator keeps on for 10 seconds, the setup is successful. Note : Default setting i s 0, SOS cod[...]
-
Page 14
14 | ENGLISH 6.4 Keyboard tone Keyboard tones can be switched o n or off. If they are switched of f, the beep when a setup is successful w ill also be swit ched off ! 6.4.1 Disable key board tone Enter Setup-state and input : When one beep i s heard and the L ED indicator keeps on for 10 seconds, the setup is successful. 6.4.2 Enable key board tone[...]
-
Page 15
15 | ENGLISH 6.5 Disarm system by RFID tag Users can enable or disable the function of d isarming the alar m system by RFID tag , or disarming silent by RFID tag. 6.5.1 Disable disar ming by RFID tag Enter Setup-state and input : When one beep i s heard and the L ED indicator keeps on for 10 seconds, the setup is successful. 6.5.2 Enable disarming [...]
-
Page 16
16 | ENGLISH 6.5.3 Disarming silently by RFID tag The alarm panel an d siren will hoo t twice when disar ming the alarm system by RFID tag. If set disar ming silently by RFID tag, the alarm syste m and siren will keep silent when disarming. Enter Setup-state and input : When one beep i s heard and the L ED indicator keeps on for 10 seconds, the set[...]
-
Page 17
17 | ENGLISH 6.6.1 Enable power savi g mode Enter Setup-state and input : When one beep i s heard and the L ED indicator keeps on for 10 seconds, the setup is successful. 6.6.2 Disable po wer saving mod e If the control panel is powered by an external 12V pow er supply (not included), i t is recommended to switch of the po wer saving mode. User s c[...]
-
Page 18
18 | ENGLISH 6.7 Change user code A user can use its own code to wake up the control panel and send Ar m, Disarm or Home mode command s to the alarm syste m. The control panel can only hav e one user code. Note : The default user code is 1234. Please change this code at first use ! Enter Setup-state and input : When one beep i s heard and the L ED [...]
-
Page 19
19 | ENGLISH 6.9 Reset the control panel After a reset the u ser code, admin code and all other setting s will be restored to default. Only the connected RFID t ags will remain wo rking. To remove the conne cted RFID tags, please refer to chapter “Connect RFID Tag to control panel”. Enter Setup-state and input : When one beep i s heard and the [...]
-
Page 20
20 | ENGLISH 8.0 Service and su pport This user’s manual has been carefu lly written by Eminen t’s technical experts. If you have problems in stalling or using t he product, please fill out the support for m at the website www .eminent-online.com/supp ort . You can also conta ct us by phone. Below you w ill find a list with phone nu mbers for e[...]
-
Page 21
21 | ENGLISH 9.0 Warning and p oints of attention Due to laws, directive s and regulat ions set out by the Europ ean parlia ment, some (wireless) devices could be subject to limitations concerning i ts use in certain European member states. In certai n European member states the use of su ch devices could be prohibited. Con tact your ( local) gover[...]
-
Page 22
22 | ENGLISH 10.0 Warranty conditions The five-year Eminen t warranty ap plies to all Eminent produc ts, unless mentione d otherwise before or during the momen t of purchase. After buy ing a second -hand Eminent produc t the remaining per iod of warranty is measured from the moment of purchase by the produ ct’s initial ow ner. Eminent warran ty a[...]
-
Page 23
23 | ENGLISH 11.0 Declaration of Conformity Application of Council Dire ctives: Manufacturer’s Na me: Eminent Type of Equip ment: Control panel Equipment Class: Commercial, Light Industrial, Cons umer PRODUCTNUM BER: EM8622 Conforms to the following standar ds: EN 301 489-1 V1.9.2 :2011 EN 301 489-3 V1.4.1 :2002 EN 300 220-1 V2.3.1 :2010 EN 300 2[...]