Go to page of
Similar user manuals
-
Switch
Enterasys Networks 6H3xx
430 pages 4.48 mb -
Switch
Enterasys Networks 4G4205-72
100 pages 2.73 mb -
Switch
Enterasys Networks D2G124-12
496 pages 3.79 mb -
Switch
Enterasys Networks A2H124-24FX
82 pages 1.36 mb -
Switch
Enterasys Networks C1H124-24
64 pages 0.65 mb -
Switch
Enterasys Networks C2G124-48P
82 pages 1.52 mb -
Switch
Enterasys Networks 7G4205-72
96 pages 2.72 mb -
Switch
Enterasys Networks 6E2xx
430 pages 4.48 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Enterasys Networks A2H254-16, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Enterasys Networks A2H254-16 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Enterasys Networks A2H254-16. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Enterasys Networks A2H254-16 should contain:
- informations concerning technical data of Enterasys Networks A2H254-16
- name of the manufacturer and a year of construction of the Enterasys Networks A2H254-16 item
- rules of operation, control and maintenance of the Enterasys Networks A2H254-16 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Enterasys Networks A2H254-16 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Enterasys Networks A2H254-16, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Enterasys Networks service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Enterasys Networks A2H254-16.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Enterasys Networks A2H254-16 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
7.5x9-inch cover with bleed on 4 sides Secur eStack A2 Fast Ether net Switches Hardware Installation Guide A2H254-16 P/N 9034173[...]
-
Page 2
[...]
-
Page 3
i Notice Enterasys Networks reserves the right to make changes in specifications and ot her information contained in this document and its web site without prior notice. The reader should in all cases consult Enterasys Ne [...]
-
Page 4
ii Regulatory Compliance Information Federal Communications Commission (FCC) Notice This device com plies with Pa r t 15 of the FCC rules. Operation is subject to the following tw o conditions: (1) this devic e may not cause harmful interference, [...]
-
Page 5
iii Electromagnetic Compatibility (EMC) This product complies with the following : 47 CFR Par t s 2 and 15, CSA C108.8, 89/336/EEC, EN 55022, EN 6100 0 ‐ 3 ‐ 2, EN 61000 ‐ 3 ‐ 3, EN 55024, AS/NZS CISPR 22, VCCI V ‐ 3. Compatibil[...]
-
Page 6
iv European Waste Electrical and Electronic Equipment (WEEE) Notice In accordance with Directive 200 2/96/EC of the European P arliament on was te elect rical and electronic equipmen t (WEEE): 1. The symbol above indi cates that separate coll ection of elect[...]
-
Page 7
v Declaration of Conformity Application of Co uncil Directiv e(s): 89/336/EEC 73/23/EEC Manufacturer’s Na me: Enterasys Networks, Inc. Manufacturer ’ s Address: 50 Minuteman Road Andover, MA 01810 USA European Representativ e Address: Enterasys Networks, Lt d. Nexus House, Newb[...]
-
Page 8
vi Enterasys Networks, Inc. Firmware License Agreement BEFORE OPENING OR UTILIZIN G THE ENCLOSED PRODUCT, CAREFULLY READ THIS LICENSE AGREEMENT. This document is an agreement (“ Agreement”) betwee n the end user (“Y ou”) and Enterasys Netw orks, Inc. on behalf of itself[...]
-
Page 9
vii 3. APPLICABLE LAW. This Agreem ent shall be interpreted and governed under the laws and in the state and federal courts of the Commonwealth of Massachusetts without regard to its conflicts of laws provisions. You a[...]
-
Page 10
viii 8. AUDIT RIGHTS. You here by acknowled ge that the inte llectual property rights associated with the Program are of critical value to Enterasys and, accordingly, You hereby agree to maintain complete books, records and ac[...]
-
Page 11
ix Contents About This Guide Who Should Use This G uide ........ ................... .................... ................... ................... ................ .......... xiii How to Use This Guide ................ ................... .................... ................ ................... ............... ........... .. xiv Related Documents .[...]
-
Page 12
x Configuring Switches in a Stack .................. ................... .................... ................... ................... .... ... 3-12 About SecureStack A2 Switch Op eration in a Stack ................. ................... ................... .......... 3-12 Recommended Procedures for New and Existing Stacks ......... .................[...]
-
Page 13
xi Figures 1-1 A2H254-16 Stackable Switch..... ................... ....................... ................... ................... ............ 1 -3 3-1 Mini-GBIC with RJ45 Connector ......... .................... ...................... .................... ................... .. 3-4 3-2 Mini-GBIC with MT-RJ Connec tor ........... ................ [...]
-
Page 14
xii[...]
-
Page 15
SecureStack A2 Inst allation Guide xiii About This Guide This guide provides an ov erview of installation, troubleshooting, and specificat ions for the Enterasys ® SecureStack A2H254 ‐ 16 stackable Ethernet switch. For information about the Command Li ne [...]
-
Page 16
How to Use This Guide xiv About This Guide How to Use This Guide Read through this guide completely to familiarize you rs el f with its contents and gain an understanding of the features and capabilities of the stackable Ethernet switch. A genera[...]
-
Page 17
Conventions Used in This Guide SecureStack A2 Installation Guide x v Conventions Used in This Guide The following conventions are used in this guide: Note: Calls the reader ’s attention to any item of information that may be of special import ance. Caution: Contains information essential to avoid damage to the equ ipme[...]
-
Page 18
Conventions Used in This Guide xvi About This Guide[...]
-
Page 19
SecureStack A2 Installation Guide 1-1 1 Introduction This chapter introduces the A2H254 ‐ 16 stackable Fast Ethernet switch. Overview The A2H254 ‐ 16 is a stackable Fast Ethernet switch, which can be adapted and scaled to help meet you r [...]
-
Page 20
Overview 1-2 Introduction The switch also suppo rts the use of a redundant DC power supply to help prev ent downtime due to an internal pow er supply failure in the switch or AC power source. Yo u can install the Secur[...]
-
Page 21
Overview SecureStack A2 Installation Guide 1-3 Figure 1- 1 A2H254-16 S ta ckable Switch S tack Connections The switch has front ‐ panel RJ45 ports 17 and 18 for connections in a stack configuration. The stacking cables used for the connections are standard[...]
-
Page 22
Connectivity 1-4 Introduction Connectivity The SecureStack A2 switch connects to Ethernet networks or w orkstations via the fixed front panel MT ‐ RJ and RJ45 ports and the tw o SFP uplink ports that support optional Mini ‐ GBICs. At [...]
-
Page 23
Management SecureStack A2 Installation Guide 1-5 Management Management of the mod ule can be either in ‐ band or out ‐ of ‐ band. In ‐ band remote management is possible using Te l n e t , Enterasys Netw orks’ NetSight ® management application, or [...]
-
Page 24
Getting Help 1-6 Introduction Getting Help For additional support related to the SecureStack A2 or this document, contact Enterasys Netw orks using one of the following methods: Before contacting Enterasys Networks for technical support, have [...]
-
Page 25
SecureStack A2 Installation Guide 2-1 2 Network Requirements Before inst alling the device, review the requirements and spec ifications in this chapter concerning the following: 10BASE-TX T wisted Pair Network When connecting a 10BASE ‐ TX segment to one of th[...]
-
Page 26
100BASE-TX Twisted Pair Network 2-2 Network Requirements 100BASE-TX T wisted Pair Network When connecting a 100BASE ‐ TX segment to one of the fixed RJ45 ports (odd numbered ports 1 ‐ 15), use Category 5 UTP cabling. The device at the other e[...]
-
Page 27
1000BASE-FX Fiber-Optic Network SecureStack A2 Installation Guide 2-3 1000BASE-FX Fiber-Optic Network The Mini ‐ GBIC port sockets 19 and 20 on the A2H254 ‐ 16 enable yo u to va r y the type of 1 ‐ Gbps port connection. At the printing of this docu[...]
-
Page 28
1000BASE-FX Fiber-Optic Network 2-4 Network Requirements[...]
-
Page 29
SecureStack A2 Installation Guide 3-1 3 Hardware Installation This chapter provides instructions to install the A2H254 ‐ 16. Follow the order of the sections listed below to correctly install the switch . Electrical Hazard: Only qualified perso nnel should perform ins[...]
-
Page 30
Considerations Prior to Installation 3-2 Hardware Installation Considerations Prior to Inst allation When installing the switch , note the following : •B e f o r e starting the installation procedure, notify the network administrator of the installation. •F o l l o w the ?[...]
-
Page 31
Installing Optional Mini-GBICs SecureStack A2 Installation Guide 3-3 Inst alling Optional Mini-GBICs This section describes how to install Mini ‐ GBICs in the SFP port slots 19 and 20 on the A2H254 ‐ 16. It is recommended that the optional Mini ‐ G[...]
-
Page 32
Installing Optional Mini-GBICs 3-4 Hardware Installation Inst allation To install a Mini ‐ GBIC that has an RJ45 connector, refer to Figure 3 ‐ 1 ; for a Mini ‐ GBIC with an MT ‐ RJ connector , refer to Figure 3 ‐ 2 ; for a Mini ‐ GBI[...]
-
Page 33
Installing Optional Mini-GBICs SecureStack A2 Installation Guide 3-5 Figure 3-2 Mini-GBIC with MT -RJ Connector 1 SFP Slot 3 Release tab 2 Mini-GBIC (MGBIC-MT01) 4 Link/Activity LED[...]
-
Page 34
Installing Optional Mini-GBICs 3-6 Hardware Installation Figure 3-3 Mini-GBIC with LC Connector Removing the Mini-GBIC 1 SFP Slot 3 Release tab 2 Mini-GBIC (MGBIC-LC01,-LC03, -LC09, MGBIC-08) 4 Link/Activity LED Caution: Do NOT remove a Mini-GBIC from a slot without relea sing the locking tab located under the front bottom end of the Mi ni-GBIC. Th[...]
-
Page 35
Installing the Switch on a Flat Surface SecureStack A2 Installation Guide 3-7 To re move a Mini ‐ GBIC from a port slot, refer back to Figure 3 ‐ 1 , Figure 3 ‐ 2 , or Figure 3 ‐ 3 , and proceed as follows: 1. Attach you r antistatic wrist strap [...]
-
Page 36
Installing the Switch on a Flat Surface 3-8 Hardware Installation Figure 3-4 Chassis Bottom, Rubber Feet Placement Guidelines for Flat Surface Inst allation Locate the switch within 152 cm (5 ft) of its pow er source and on a surface as shown in Figure 3 ‐ 5 . A ?[...]
-
Page 37
Rack Mounting the Switch SecureStack A2 Installation Guide 3-9 If you are installing sev eral switch es in a stack, proceed to “ Connecting Sta cking Cables ” on page 3 ‐ 11. If the switch is being installed as a standalone switch , pro[...]
-
Page 38
Rack Mounting the Switch 3-10 Hardware Installation Guidelines for Rackmount Inst allation The installation site must be withi n reach of the network cablin g and meet the requirements listed below: • Appro priate grounded pow er receptacles must be located ?[...]
-
Page 39
Connecting Stacking Cables SecureStack A2 Installation Guide 3-11 2. With the mou nting brackets attached, position the switch between the vert ical frame members of the 19 ‐ inch rack as shown in Figure 3 ‐ 7 . Then fa sten the switch secure[...]
-
Page 40
Configuring Switches in a Stack 3-12 Hardware Installation Figure 3-8 S tacking Cable Conn ections After connecting the cables to the stacking ports, proceed to “ Configuring Switches in a Stack ” on page 3 ‐ 12 for instructions. Configuring Switches in a S t ack The [...]
-
Page 41
Configuring Switches in a Stack SecureStack A2 Installation Guide 3-13 Once installed in a stack, the switches behave and perform as a single switch. As such, you can start with a single switch and add more switches as yo ur network ?[...]
-
Page 42
Configuring Switches in a Stack 3-14 Hardware Installation Recommended Procedures for New and Existing S tacks Inst alling a New St ackable Syst em of Up to Eight Switches Use the following procedure to install a new stack of up to eight switches out of the box. Before appl[...]
-
Page 43
Connecting AC and RPS-SYS Power SecureStack A2 Installation Guide 3-15 Adding a New Switch to an Existing St ack Use the following procedure to install a new switch to an existing stack configuration. This procedure assumes that the new switch being added ha[...]
-
Page 44
Connecting AC and RPS-SYS Power 3-16 Hardware Installation Figure 3-9 Switch Rear V iew 3. Observe the pow er CPU LED (not shown), located on the front panel. During the initialization, the CPU LED will start by illuminating sol id amber, then start [...]
-
Page 45
Connecting AC and RPS-SYS Power SecureStack A2 Installation Guide 3-17 C2RPS-SYS Redundant Power System If you are installing an optional re dundant power system (C2RPS ‐ SYS), refer to the installation instructions supplied with the Secure Stack RPS. The switch ?[...]
-
Page 46
Connecting to Console Port for Local Management 3-18 Hardware Installation S tack Initialization Overview When you install and connect all the stacking cables to the switches in the stack before applying power to the swi tches, the following occurs: •T h e[...]
-
Page 47
Connecting to Console Port for Local Management SecureStack A2 Installation Guide 3-19 Using a DTE modem DB9 female ‐ to ‐ DB25 female cable, you can connect products equipped with a DB9 DTE male console port to a VT series terminal or VT [...]
-
Page 48
Connecting to Console Port for Local Management 3-20 Hardware Installation When these parameters are set, the Startup screen will display . Proceed to “ Connecting to the Network ” on page 3 ‐ 23 . Figure 3-12 Connecting an IBM PC or Comp atible Connecting to a VT Series [...]
-
Page 49
Connecting to Console Port for Local Management SecureStack A2 Installation Guide 3-21 When these parameters are set, the Startup screen will display . Proceed to “ Connecting to the Network ” on page 3 ‐ 23 . Figure 3-13 Connecting a VT Series T erminal Connecting to a M[...]
-
Page 50
Connecting to Console Port for Local Management 3-22 Hardware Installation When these parameters are set, the Startup screen will display . If the switch es ar e in a stacked configuration, proceed to “ Connecting to the Network ” on page 3 ?[...]
-
Page 51
Connecting to the Network SecureStack A2 Installation Guide 3-23 Connecting to the Network This section provides the procedure to connect fiber ‐ optic cables from the fi xed front panel MT ‐ RJ ports to the network or other devi ces. In addition thi[...]
-
Page 52
Connecting to the Network 3-24 Hardware Installation 2. Insert the MT ‐ RJ cable connector into the MT ‐ RJ front panel port unti l it clicks into place. Figure 3-15 Connecting a Fiber-Opt ic Cable Segment to MT -RJ Port Caution: Do not touch the ends of the fiber-op tic strands, and d[...]
-
Page 53
Connecting to the Network SecureStack A2 Installation Guide 3-25 3. V erify that a link exists by chec king that the Link/Act ivity LED is ON (solid green or blinking green). If the Link/ Activity LED is OFF , perform the following st eps [...]
-
Page 54
Connecting to the Network 3-26 Hardware Installation To connect an MT ‐ RJ cable to a fixed MT ‐ RJ connector of a Mini ‐ GBIC: 1. Remove the protectiv e covers from the Mini ‐ GB IC MT ‐ RJ fiber ‐ optic port and from the connectors [...]
-
Page 55
Connecting to the Network SecureStack A2 Installation Guide 3-27 Connecting Fiber-Optic Cabl es to LC Mini -GBIC Port s This section describes how to connect •a 100 0BASE ‐ SX multimode fiber ‐ optic segment from the netwo rk or other devices to an LC port con[...]
-
Page 56
Connecting to the Network 3-28 Hardware Installation To connect an LC cable connector to a fixed LC connector of a Mi ni ‐ GBIC: 1. Remove the protectiv e covers from the Mini ‐ GB IC LC fiber ‐ optic po rt and from the connectors on ?[...]
-
Page 57
Connecting to the Network SecureStack A2 Installation Guide 3-29 Connecting UTP Cabl es to RJ45 Port s The fixed RJ4 5 front panel 10/100 Mbps ports and the RJ45 Mini ‐ GBIC (MGBIC ‐ 02) Gigabit ports are both internally crossed. When connecting a works ta t[...]
-
Page 58
Connecting to the Network 3-30 Hardware Installation 3. V erify that a link exists by chec king that the Link/Act ivity LED is ON (solid green or blinking green). If the Link/ Activity LED is OFF , perform the following st eps until i[...]
-
Page 59
Connecting to the Network SecureStack A2 Installation Guide 3-31 Figure 3-17 Four-Wire Crossov er Cable RJ45 Pinouts f or 10/100BASE-TX Figure 3-18 Four-Wire S traight-Through Cable RJ45 Pinout s for 10/100BASE-TX 1 RJ45 switch port 3 RJ45-to-RJ45 crossover cable 2 Other device port 4 RX+/RX- and TX+/TX-connecti ons These connections must share a c[...]
-
Page 60
Connecting to the Network 3-32 Hardware Installation Figure 3-19 Eight-W ire Crossover Cable RJ45 Pinout s for 10/100/1000BASE-TX Figure 3-20 Eight-W ire Straight- Through Cable RJ45 Pinout s for 10/100/ 1000BASE-TX 1 RJ45 device port 3 RJ45-to-RJ45 crossover c able 2 Other device port 1 RJ45 device port 3 RJ45-to-RJ45 straight-through cable 2 Othe[...]
-
Page 61
Completing the Installation SecureStack A2 Installation Guide 3-33 Completing the Inst allation After installing the switch and making the connections to the net work, access the switch management, as described below . Initial Logon to Switch Management To initially access [...]
-
Page 62
Completing the Installation 3-34 Hardware Installation[...]
-
Page 63
SecureStack A2 Installation Guide 4-1 4 T roubleshooting This chapter provides information concerning the following: This device contains a battery that is not considered a user replaceable part. If the battery needs to be replaced, contact c[...]
-
Page 64
Using LANVIEW 4-2 Troubleshooting Using LANVIEW The A2H254 ‐ 16 supports the Enterasys Netw orks bui lt ‐ in LANVIEW LED visual diagnostic and status monitoring system. The LANVIEW LEDs on the A2H254 ‐ 16 are located as shown in Figure [...]
-
Page 65
Using LANVIEW SecureStack A2 Installation Guide 4-3 T able 4-1 LANVIEW LEDs LED Color State Recommended Acti on CPU Off Power disconnected. If the LED remains off after connecting AC power or DC power from an RPS, check the following: 1. Make sure there is power at the power source (AC source and RPS if applicable). 2. Replac e the power cord with [...]
-
Page 66
Using LANVIEW 4-4 Troubleshooting DOWN Off No valid connection to switch stackup connector . 1. Make sure the switch connected to the stackup connector is powered on. 2. Replace cable with a known goo d one. 3. If the problem still exists, contact Enterasys Networks for technical support. Green Solid . V alid connection to switch stackup connector [...]
-
Page 67
Using LANVIEW SecureStack A2 Installation Guide 4-5 RPS Off The RPS LED remains off regardless if the RPS is atta ched or not. The L ED being in its off st ate is not a n indication that the RPS is not functioning properly and won’t supply power in the event of an AC power supply failure. See Amber state below . None. Amber Solid .The switch inte[...]
-
Page 68
Troubleshooting Checklist 4-6 Troubleshooting T roubleshooting Checklist If the device is not work in g properly , refer to Ta b l e 4 ‐ 2 for a checklist of problems, possible causes, and recommended actions to resolve the problem. T able 4-2 T rouble[...]
-
Page 69
Troubleshooting Checklist SecureStack A2 Installation Guide 4-7 Cannot contact the SecureS tack A2 through in-band management. IP address not assigned. Refer to the SecureSt ack A2 Configuration Guide for the IP address assignment procedure. Port is disabled . This is normal if the swi tch is a Member in a stack. If operating as a standalone sw itc[...]
-
Page 70
Using the Reset Password Button 4-8 Troubleshooting Using the Reset Password Button If you forget the SecureSt ack A2 login passw ord, use the Reset Pas s w o rd button as described in the following procedure. Figure 4-2 Reset Password Button To reset the Secure[...]
-
Page 71
SecureStack A2 Installation Guide A-1 A Specifications This appendix provides information about the foll owing: Enterasys Netw orks reserves the right to change the specifications at any time without notice. Switch S pecifications Ta b l e A ‐ 1 provides the ?[...]
-
Page 72
Switch Specifications A-2 Specifications Dimensions 44.1 cm (17.36 in.) W x 4.4 cm (1.73 in.) H x 21.0 cm (8. 27 in.) D Approximate Weight Gross: Net: 3.5 kg (7.68 lb) (shipping carton containing one module) 2.7 kg (5.94 lb) (one module without packaging) Heat Dissipation (maximum) 174 BTU/HR Power Amperage 1 10 V/0.5 A; 220 V/0.47 A Power Consumpt[...]
-
Page 73
Mini-GBIC Input/Output Specifications SecureStack A2 Installation Guide A-3 Mini-GBIC Input/Output S pecifications The Mini ‐ Gigabit Ethernet Card (Mini ‐ GBIC) port interface slots can support 1 ‐ Gbps fiber ‐ optic connections as described in Ta b l e A ‐ 2 . The ?[...]
-
Page 74
Gigabit Ethernet Specifications A-4 Specifications Gigabit Ethernet S pecifications The following specifications for the Mini ‐ GBICs shown in Ta b l e A ‐ 3 through Ta b l e A ‐ 11 meet or exceed the IEEE 802.3z ‐ 1998 standard. MGBIC-LC01/MGBIC-MT01 S pec ificatio[...]
-
Page 75
Gigabit Ethernet Specifications SecureStack A2 Installation Guide A-5 MGBIC-LC09 S pecific ations (1000BASE-LX) T able A-6 MGBIC-LC03 Operating Range Item Modal Bandwid th @ 1310 nm Range 62.5 µm MMF 160 MHz/km 2,000 Meters 50 µm MMF 400 MHz/km 2,000 Meters T able A-7 MGBIC-LC09 Optical S pecifications Item 62.5 µm MM F 50 µm MMF 10 µm SMF T r[...]
-
Page 76
Gigabit Ethernet Specifications A-6 Specifications MGBIC-08 Specificati ons (1000BASE-ELX) MGBIC-02 Specifications (1000BASE-T) T able A-9 MGBIC-08 Optical Spec ifications Item T ransmit Power (minimum) -0 dBm, min. +2 dBm, typical +5 dBm, max. Receive Sensitivity -24 dBm, min. -26 dBm, typical Maximum Input Power -3 dBm Link Power Budget 1 (Full D[...]
-
Page 77
Console Port Pinout Assignments SecureStack A2 Installation Guide A-7 Console Port Pinout Assignment s The Console port is a DB9 serial communications port for local access to Local Management. Refer to Figure A ‐ 1 for the Co nsole port pin assignment[...]
-
Page 78
Regulatory Compliance A-8 Specifications[...]
-
Page 79
Index-1 Index Numerics 1000BASE-FX requirements 2-3 1000BASE-T requirements 2-2 100BASE-FX requirements 2-2 100BASE-T requirements 2-2 10BASE-T requirements 2-1 A A2H254-16 overview of 1-2 C Cable fiber budget A-3 Cable specifications 1000BASE-FX network 2-3 1000BASE-T network 2-2 100BASE-FX network 2-2 100BASE-T network 2-2 10BASE-T network 2-1 CL[...]
-
Page 80
Index-2 P Pinout assignments UTP 4-wire crossover cable 3-3 1 UTP 4-wire straight-through cable 3-31 UTP 8-wire crossover cable 3-3 2 UTP 8-wire straight-through cable 3-32 Power connection AC 3-15 RPS DC 3-17 R Rackmount installation guidelines for 3-10 Receive/Transmit LEDs viewing of 4-2 Redundant Power Supply Capability introduction to 1-3 Regu[...]