Go to page of
Similar user manuals
-
Ventilation Hood
Field Controls EL-1R
12 pages 0.83 mb -
Ventilation Hood
Field Controls SWG
12 pages 0.61 mb -
Ventilation Hood
Field Controls SWGII
12 pages 0.61 mb -
Ventilation Hood
Field Controls EL-1
12 pages 0.83 mb -
Ventilation Hood
Field Controls PVU-300
16 pages 0.87 mb -
Ventilation Hood
Field Controls PVO-300
12 pages 0.55 mb -
Ventilation Hood
Field Controls TYPE "C"
8 pages 0.94 mb -
Ventilation Hood
Field Controls B-34TJ
8 pages 0.7 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Field Controls PVO-300, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Field Controls PVO-300 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Field Controls PVO-300. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Field Controls PVO-300 should contain:
- informations concerning technical data of Field Controls PVO-300
- name of the manufacturer and a year of construction of the Field Controls PVO-300 item
- rules of operation, control and maintenance of the Field Controls PVO-300 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Field Controls PVO-300 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Field Controls PVO-300, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Field Controls service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Field Controls PVO-300.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Field Controls PVO-300 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
2630 Airport Road · Kin ston, NC 28504 Phone: 252-522-3031· Fax: 252-522-0214 www.fieldcontrols.com POWER VENTER SYSTEM Mode l: PVO-300, PVO-600 Included is one ETL and cETL listed Powe r Vente r to be used primarily with a single 120VAC controlled oil fired furnace, boiler, or water heater. The PVO may be used to common vent multiple appliance s[...]
-
Page 2
Page 2 UNIT SPECIFICATIONS (See Table 1 and Figure 1 ) Table 1 UNIT DIMENSIONS (INCHES) MODEL “H” “W” “D” I/O* PVO-300 7.50 9.25 7.00 4/4 PVO-600 8.75 9.75 8.50 4/4 * Inlet and outlet diameter. ELECTRICAL RATINGS MODEL VAC Hz RPM WATT AM P TP** PVO-300 120 60 3000 145 2.1 YES PVO-600 120 60 3000 167 1.5 YES ** Thermally protected motor.[...]
-
Page 3
Page 3 POWER VENTER SIZING In order to choose the correct size po wer venter for a particu la r installation, the total input firing rate and total equivalen t length of vent pipe to be u sed must be kno wn. Refer to Tabl e 2 to determine the maxim um allowable equivalent feet of pipe for each model used with the pipe diameters shown. When venting [...]
-
Page 4
Page 4 INSTALLATION SAFETY INSTRUCTIONS CAUTION: This devi ce must be install ed by a qualified install e r in accordance with the m anufacturer's installation instructions. Appliances should have a minim um of 75% co mbustion efficiency or have a maximum measured flue gas temperature of 550°F at the inlet of the venter. 1. The power venting [...]
-
Page 5
Page 5 INSTALLATION OF POWER VENTER CAUTION: Failure to inst all, maintain and/or opera te the power venting system in accordan ce with manufacturer' s instructions will result in conditions whic h may produce bodily injury and/or property dam age. 1. Remove power venter from box and inspect unit for damage. If the carton has been crushed or m[...]
-
Page 6
Page 6 Diagram B Diagram C[...]
-
Page 7
Page 7 M ULTIPLE A PPLIA NCE S YSTEMS When using one PVO power vente r to common vent more than on e appliance, a Control Kit is required for e ach additional appliance. 1. Connect the negative pressure port of each air pressure fan proving switch on all Control Kits being used to the provided tee mounted on the PVO. (See Figure 4) 2. Remove the ca[...]
-
Page 8
Page 8 GENERAL INSTALLATION INSPECTION Follow recommende d procedures for safety inspection of a heat ing appliance in accorda nce with the National Fuel Gas Code A.N.S.I. Z223.1. The following procedure will help in evaluat ion of the venti ng system. It is intended as a guide to aid in determining that the applian ce is properly installe d and is[...]
-
Page 9
Page 9 PV SERIES POWER VENTER: VERTICAL VENTING OPTION Diagram D illustrates correct an d incorrec t installation of PV series venter in vertical vent c onfiguration (except PVE- 1200). The correct installation maintain s the required vertical po sition of the pressure switch; the incorrect installation does not. The following conditions mu st also[...]
-
Page 10
Page 10 REPLACEMENT PARTS LIST The following items are available for replacement, if necessary. REPLACEMENT PARTS LIST DESCRIPTION PVO-300 PVO-600 Motor 46032000 46083300 Blower Wheel 46033400 46089400 Post Purge Relay Timer 46144700 4614470 Pressure Switch 46311000 4631 1000 VENTING SYSTEM OPERATIONAL INFORMATIO N Date: Oil Burner Nozzle S ize Oil[...]
-
Page 11
Page 11 NOTES[...]
-
Page 12
Page 12 P/N 46311800 Rev E 11/07[...]