Go to page of
Similar user manuals
-
Ventilation Hood
Gaggenau AH 590-720
10 pages 0.43 mb -
Ventilation Hood
Gaggenau AH 530-720
18 pages 0.79 mb -
Ventilation Hood
Gaggenau VL 041-107
9 pages 0.26 mb -
Ventilation Hood
Gaggenau AW 201-790
20 pages 0.91 mb -
Ventilation Hood
Gaggenau AH 600-190
19 pages 1.05 mb -
Ventilation Hood
Gaggenau 900791
48 pages 2.35 mb -
Ventilation Hood
Gaggenau VL 040-107
9 pages 0.26 mb -
Ventilation Hood
Gaggenau AW 230 790
64 pages 2.08 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Gaggenau AH 590-720, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Gaggenau AH 590-720 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Gaggenau AH 590-720. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Gaggenau AH 590-720 should contain:
- informations concerning technical data of Gaggenau AH 590-720
- name of the manufacturer and a year of construction of the Gaggenau AH 590-720 item
- rules of operation, control and maintenance of the Gaggenau AH 590-720 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Gaggenau AH 590-720 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Gaggenau AH 590-720, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Gaggenau service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Gaggenau AH 590-720.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Gaggenau AH 590-720 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
Operating and assembly instructions AH 590-720 Freely Suspended Insular Hood[...]
-
Page 2
1 AH 590-720 6. Assembly instructions Page 13-19 6.1 T echnical data Page 13 6.2 Installation Page 14-19[...]
-
Page 3
13 6.1 T echnical data W eight without support frame and LK: 35 kg W eight with support frame and LK: max. 60 kg Dimensions: 47 3 / 16 ´ ´ x 27 1 / 2 ´´ / 1 198 x 700 mm Electrical connection Pay attention to the rating plate data. The appliance must only be connected by an authorised specialist . The specialist is respon- sible for perfect fun[...]
-
Page 4
6.2 Installation W ARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJUR Y TO PERSONS, OBSER VE THE FOLLOWING: a.) Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction. b.) Sufficient air is needed for proper combustion end exhaus[...]
-
Page 5
15 Flexible aluminium pipes, corrosion-protected sheet metal pipes and exhaust air pipes whose material conforms to fire B1 in accordance with DIN 4102 can be used. Exhaust air pipes should have a nominal diameter of 6 ´ ´ / 150 mm. Pay particular attention to ensuring that – the exhaust air ducts and pipes are kept as short as possible – the[...]
-
Page 6
Installation above gas cooker / gas hob Installation of the appliance above a gas cooking device must conform to national safety regulations. A minimum distance of 30 ´´ / 762 mm between the hood and gas appliance must be observed. Gas appliances may only be used under the extractor hood when pots and pans are placed on them! Operation above gas [...]
-
Page 7
17 Installation: 1. Using the drilling template mark the position of the screws on the ceiling. 2. Drill 4 holes Ø 8 mm for the wall plugs. Push the plugs flush with the ceiling (Fig. 19). 3. T urn two screws to a 10 mm gap. Both screws are placed in a position, in which at a later stage of the installation the key-holes of the suppor- ting frame [...]
-
Page 8
18 6. Adjust the support frame to the desired height and secure with 8 screws. The length of the support frame can be adjusted in steps of 3 / 4 ´´ / 20 mm from 15 3 / 16 ´´ / 386 mm to 25 7 / 16 ´´ / 646 mm (Fig. 21). Note: ensure that the minimum distance between the hob and the extractor hood is maintained – 24 ´´ / 600 mm for an elect[...]
-
Page 9
11 . Adjust the hood to the final position and attach it with all 4 screws to the ceiling (Fig. 23). 12. Connect the air outlet pipe. 13. Connect the hood to the electricity supply . 14. Pull the top duct unit up into its final position. Secure the top duct unit with 4 screws on the support frame (Fig. 24). Note: avoid scratches when pulling the el[...]
-
Page 10
5551 McFADDEN AVENUE HUNTINGTON BEACH, CA 92649 USA Y (800) 828-9165 · FAX (714) 901-0979 www.gaggenau.com/us GAGGENAU HAUSGERÄTE GMBH P.O. BOX 10 02 50 · D - 80076 MÜNCHEN GERMANY Y (0 89) 45 90-01 FAX (0 89) 45 90-23 47[...]