Go to page of
Similar user manuals
-
Ventilation Hood
Gaggenau AW 230 790
64 pages 2.08 mb -
Ventilation Hood
Gaggenau AH 590-720
10 pages 0.43 mb -
Ventilation Hood
Gaggenau AW 200-790
20 pages 0.91 mb -
Ventilation Hood
Gaggenau AH 600-190
19 pages 1.05 mb -
Ventilation Hood
Gaggenau AW 201-790
20 pages 0.91 mb -
Ventilation Hood
Gaggenau 900791
48 pages 2.35 mb -
Ventilation Hood
Gaggenau AH 530-790
18 pages 0.79 mb -
Ventilation Hood
Gaggenau AH 530-720
18 pages 0.79 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Gaggenau AW 200-790, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Gaggenau AW 200-790 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Gaggenau AW 200-790. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Gaggenau AW 200-790 should contain:
- informations concerning technical data of Gaggenau AW 200-790
- name of the manufacturer and a year of construction of the Gaggenau AW 200-790 item
- rules of operation, control and maintenance of the Gaggenau AW 200-790 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Gaggenau AW 200-790 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Gaggenau AW 200-790, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Gaggenau service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Gaggenau AW 200-790.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Gaggenau AW 200-790 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
Operating and Assembly Instructions AW 200-790 AW 201-790 Extractor Hood[...]
-
Page 2
1 AW 200-790 AW 201-790 Preface Safety notes Page 3 1. Important notes Page 4-5 1.1 F or your safety Page 4 1.2 Operating for the first time Page 5 1.3 About use Page 5 2. F eatures Page 6 3. Operation Page 7-9 4. Cleaning and care Page 10-1 1 5. Maintenance Page 12 6. Assembly instructions Page 13-18 6.1 T echnical data Page 13 6.2 Installation Pa[...]
-
Page 3
2 Preface With your new extractor hood, working in the kitchen will be even more fun. The appliance offers you a number of advantages: – a good extraction capacity with low noise values, – a large number of control functions, – optimum illumination of the cooking surface by a dimmable halogen light. To ensure that you will be able to use this[...]
-
Page 4
W ARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJUR Y TO PERSONS, OBSER VE THE FOLLOWING: a.) Use this unit only in the manner intended by the manufacturer . If you have questions, contact the manufacturer . b.) Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power[...]
-
Page 5
4 1.1 F or your safety – Damaged appliances must not be operated. – The appliance must only be connected by an authorised specialist , paying attention to the relevant regulations of the power supply companies and the regional construction regulations. Also observe the assembly instructions! – Connecting cables must not come into contact with[...]
-
Page 6
1.2 Operating for the first time Before operating the appliance for the first time, please pay attention to the following notes: – The appliance must be installed and connected by a specialist before it is operated for the first time. – Conscientiously read through the operating and assembly instructions before operating the appliance for the f[...]
-
Page 7
6 2. F eatures 1 V entilation duct 2 Control panel 3 Grease filters 4 Lighting Installation accessories for exhaust air mode Stainless steel-design ventilation duct: LK 010-012 for ceiling heights of 7 ´ ´ 4 ´ ´ - 8 ´ ´ 6 ´ ´ LK 010-022 for ceiling heights of 8 ´ ´ 6 ´ ´ -9 ´ ´ 9 ´ ´ Aluminium-design ventilation duct: LK 01 1-012 fo[...]
-
Page 8
7 3. Operation After they have been pressed, all functions selection keys except 0 (“Motor off”) are backlit in green. Light The lighting can be switched on or off, regardless of whether the wall extractor is in operation, by pressing the key (see Fig. 4). When you briefly press the key , the lighting is increased up to the maximum level. Y ou [...]
-
Page 9
8 The Int key for the intensive level should be pressed when browning and frying in an open pan (see Fig. 6). If you have switched on the hood by selecting the intensive level, it will be switched off again automatically after 5 minutes. If you press the Int key while the hood is running at fan level 1, 2 or 3 , the electronic control will switch b[...]
-
Page 10
9 Special functions: Intensive time: Y ou can set the intensive level running time to 3, 5 or 10 minutes by simultaneously pressing the Int key and the 1, 2 or 3 key and you can store this setting (see Fig. 9). When delivered, the appliance is set to five minutes, i.e. the combination of the Int key and the key 2 . Delayed shut-off: Delayed shut-of[...]
-
Page 11
10 Cleaning the grease filters The grease filter saturation display F flashes after an operating time of 30 hours to you indicate to you that you should clean the grease filter (see Fig. 3). The grease filters can of course be cleaned at any time, even if the grease filter saturation display has not started to flash. The stainless steel grease filt[...]
-
Page 12
11 Cleaning the extractor hood Clean the exterior of your extractor hood with a soft cloth and mild detergent solution. Do not use any strong, caustic or abrasive cleaning agents. Do not use any abrasive sponges or brushes either . Clean the stainless-steel extractor hood (A W 200) with stainless steel cleaner . Do not place any objects with sharp-[...]
-
Page 13
The appliance must be disconnected from the power supply during all repair work. If the appliance does not function correctly , check the fuses first. If the power supply is functioning correctly , but your appliance still does not work, please contact your Gaggenau dealer who will provide you with the address and telephone number of your nearest m[...]
-
Page 14
13 W ARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJUR Y TO PERSONS, OBSER VE THE FOLLOWING: a.) Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction. b.) Sufficient air is needed for proper combustion end exhausting of gases [...]
-
Page 15
14 6.2 Installation The applicable regulations of the energy supply companies and the regional construction regulations must be observed when installing the hood. This hood has been approved for installations as low as 30 ´ ´ and as high as 36 ´ ´ above the cooktop. The hood can be used in the exhaust or circulating air mode . The exhaust air c[...]
-
Page 16
15 Flexible aluminium pipes, corrosion-protected sheet metal pipes and exhaust air pipes whose material conforms to fire B1 in accordance with DIN 4102 can be used. Exhaust air pipes should have a nominal diameter of 6 ´´ / 150 mm. P ay particular attention to ensuring that – the exhaust air ducts and pipes are kept as short as possible – the[...]
-
Page 17
16 Proceed as follows: – From the bottom edge of the hood, mark a center line on the wall. – With the aid of the drilling template, mark the positions of the screws on the wall (Fig. 19). Note: this hood has been approved for installations as low as 30 ´ ´ and as high as 36 ´ ´ above the cooktop. – Using the drilling template, drill the 6[...]
-
Page 18
– Secure the hood on the wall with the four screws b (Fig. 21 and 22). F or exhaust air mode proceed as follows: – Establish the pipe connection. – Establish the electrical connection. – Stainless steel chimney only (LK 010-012/022): pull the protective film off the chimney’s trims. Note: avoid damaging the sensitive metal surfaces. – F[...]
-
Page 19
F or circulating air mode use the installation set included with the ventilation ducts LK 010-1 12/122 und LK 01 1-1 12/122. Y ou also need an activated charcoal filter (KF 001-010). Proceed as follows: – Slightly loosen the screws of the retaining bracket for the chimney paneling. Hang the angle pieces onto the screws and tighten the screws. –[...]
-
Page 20
EN 780 DEDHAM STREET CANTON, MA 02021 USA Y 800.828.9165 www.gaggenau-usa.com GAGGENAU HAUSGERÄTE GMBH CARL-WERY-STR. 34 · 81739 MÜNCHEN GERMANY Y (0 89) 45 90 - 03 FAX (0 89) 45 90 - 23 47[...]