A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Gateway MG1-1000, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Gateway MG1-1000 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Gateway MG1-1000. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Gateway MG1-1000 should contain:
- informations concerning technical data of Gateway MG1-1000
- name of the manufacturer and a year of construction of the Gateway MG1-1000 item
- rules of operation, control and maintenance of the Gateway MG1-1000 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Gateway MG1-1000 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Gateway MG1-1000, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Gateway service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Gateway MG1-1000.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Gateway MG1-1000 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    MicroGate™ Online Kitchen™ Gateway User Guide MG1-1000 January 2005 Part Number: 4911000-010 Revision Number: A3 MicroGate™ User Manual 1[...]

  • Page 2

    TABLE OF CONTENTS I. INTRODUCTION ............................................................................................................................... 3 II. FEATURES AND SPECIFICATI ONS ............................................................................................. 5 A RCHITECTURE ...........................................[...]

  • Page 3

    I. Introduction • Everything you need for full NAFEM protocol compliance • Translates and organizes your legacy equipment' s data into the NAFEM Data Protocol framework • Supports all of the MIBs defined by the NAFEM Data Protocol Group • Built-In Web Server • Optional Modem for installations without a network infrastructure • Conn[...]

  • Page 4

    Total Online Kitchen™ Solution Package Coupled with E-Control Systems' enterp rise Raptor W eb Software™, equipment manufacturers, systems integrators, and IT professionals have a total Online Kitchen™ system to help manage a fully integrated re staurant. Never before has there been such a synergy between all aspects of the restaurant. M[...]

  • Page 5

    II. Features and Specifications Architecture CPU: Advanced High Performance Motorola 32-bit embedded PowerPC ™ Network Processor with 66 MIPS at 50 MHz Memory: 16 Mbytes of SDRAM (expandable to 64 Mbytes) 2 Mbytes of Flash (expandable to 16 Mbytes) 512 Kbytes of battery-backed SRAM (optional) Real time clock with battery backup Serial Interface P[...]

  • Page 6

    With Modem: Input Current (25 MHz Clock): 490mA max Input Current (50 MHz Clock): 610mA max Environmental Operating: 0 C to 70 C (32 F to 158 F) Storage: -40 C to 85 C (-40 F to 185 F) Humidity: Maximum 95% Relati ve Humidity, non-condensing Altitude: 10,000 ft (3048 m) m ax Physical Specifications TOL ERANCES .010 Inches 4701000A 1 Figure 1 Withou[...]

  • Page 7

    III. Hardware Description The MicroGate™ is meant to be con nected between a local network/inter net (using the LAN Port) and the equipment(s) (using any of the serial interfaces ). The MicroGate ™ also includes 4 LED indicators to simplify in stallation and network troubleshooting. The following figure shows the components/connectors of the ga[...]

  • Page 8

    LED Indicators Table 2 - LED Indicators Designator Name Condition Status On The Ethernet Port has esta blished a valid network connection DS1 Link (green) Off Network connection does not exist, or bad cable. DS2 Activity (green) Flashing The Ethernet Port is transmitting or receiving traffic DS3 Heartbeat (green) Flashing (1 sec rate) Gateway is al[...]

  • Page 9

    RS232 Serial Port Pin Assignment Table 5 - J4 (RS232 Channel #1) or J9 (Channel #2) Pin Number Name Description Type 1 CD Carrier Detect Input 2 DSR Data Set Ready Input 3 RX Receive Input 4 RTS Request To Send Output 5 TX Transmit Output 6 CTS Clear To Send Input 7 DTR Data Terminal Ready Output 8 RI Ring Indicator Input 9 Ground Ground Power 10 +[...]

  • Page 10

    Table 7 - J7 RS485 Channel #2 Pin Number Name Description Type 2 RS485_RX+ Non-Inverting Receiver Input (Full Duplex Mode) Input 4 RS485_RX- Inverting Receiver Input (Full Duplex Mode) Input 6 RS485_GND RS485 Ground (Not signal Ground!!!) Power RS485_TX+ Non-Inverting Driver Output (Full Duplex mode) Output 8 RS485_TX/RX+ Non-Inverting Receiver Inp[...]

  • Page 11

    Ethernet (RJ45) Cable Specifications and Pin Assignments Figure 3 Table 8 - Cable Specification Cable Type Max. Length Connector 10BASE-T Cat. 3, 4, 5 100-ohm UTP 100 m (328 ft) RJ45 Table 9 - J1 Ethernet Pin Number MDI Signal Name MDI-X Signal Name 1 Transmit Data (TD+) Receive Data (RD+) 2 Transmit Data (TD-) Receive Data (RD-) 3 Receive Data (RD[...]

  • Page 12

    IV. Inst allation and Configuration System Requirements You must meet the fo llo wing requirements to install and configure the MicroGate™: • Static IP address, Subnet Mask, and Gateway Address to assign the MicroGate™ • A computer equipped with a 10 Mb ps, 100 Mbps, or 10/100 Mbps Fast Ethernet Card, or USB-to-Ethernet converter. Computer [...]

  • Page 13

    Basic Network Confi guration Procedure 1. Start the Discovery Utility by selecting Start > Programs > Raptor Web Software > ECSDiscovery – This utility might reside in a different location depending on how it was installed. Figure 4 2. Click on Start Discovery (see Figure 4 , note #1) to start looking for E-Control Systems’ units on yo[...]

  • Page 14

    Figure 6 4. Once the row corresponding to the u nit to be configured is highlighted, click on Edit Unit (see Figure 6 , note #1) to bring up the Unit’s Properties Figure 7 MicroGate™ User Manual 14[...]

  • Page 15

    5. Change the IP Address, Subnet Mask, and Gateway Address as needed and then click on Update (see Figure 7 , note #1) to send confi guration to the unit. To quit without updating the unit, click on the X (see Figure 7 , note #2) 6. Writing the configuration a nd restarting the unit can ta ke as long as 2 m inutes. In that time you will see DS3 sto[...]

  • Page 16

    V. Part Number Selection See Figure 8 for configuration options and sugge stions. For custom configurations please consult E-Control Systems. Functional Options Connector Options L No add-on modules A None M 33.6 Kbps Modem Module B Header only C Shrd/Keyed Conne ctor for wire or ribbon type mat ing cables* S Standard (no options) B Battery backup [...]

  • Page 17

    VI. Limited W arranties E-Control Systems' Limi ted Warranty Statement Limited Warranty Statement: E-Control Systems ("ECS") warrants its products to be free from defects in workmanship and materials, under norma l use and service, for the applicable warranty term. All ECS products carry a standard 1 year limited warranty from the da[...]

  • Page 18

    ADVISED OF THE POSSIBILITY OF SUCH DAM AGES. SOME COUNTRIES DO NOT ALLOW THE EXCLUSION OF IMPLIED WARRANTIES OR THE LIMITATION OF INCIDENTAL OR CONSEQUENTI AL DAMAGES FOR CONSUMER PRODUCTS, SO THE ABOVE LIMITATIONS AND EXCLUS IONS MAY NOT APPLY TO YOU. THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS, WHICH MAY VARY FROM COUNTRY TO COUNTRY. NOTH ING I[...]