Go to page of
Similar user manuals
-
Power Supply
GE 500
10 pages 0.35 mb -
Power Supply
GE 20
88 pages 2.42 mb -
Power Supply
GE 40
88 pages 2.42 mb -
Power Supply
GE 300
38 pages 3.89 mb -
Power Supply
GE 1000-1500-2000-3000 VA
20 pages 0.48 mb -
Power Supply
GE 700
10 pages 0.35 mb -
Power Supply
GE LP11U
48 pages 3.24 mb -
Power Supply
GE GEK-106465A
43 pages 0.66 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of GE 1000-1500-2000-3000 VA, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of GE 1000-1500-2000-3000 VA one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of GE 1000-1500-2000-3000 VA. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of GE 1000-1500-2000-3000 VA should contain:
- informations concerning technical data of GE 1000-1500-2000-3000 VA
- name of the manufacturer and a year of construction of the GE 1000-1500-2000-3000 VA item
- rules of operation, control and maintenance of the GE 1000-1500-2000-3000 VA item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of GE 1000-1500-2000-3000 VA alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of GE 1000-1500-2000-3000 VA, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the GE service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of GE 1000-1500-2000-3000 VA.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the GE 1000-1500-2000-3000 VA item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
User manual Digital Energy GT Series Uninterruptible Power Supply 1000 - 1500 - 2000 - 3000 VA UL - version Manufactured by: GE Consumer & Industrial General Electric Company Telephone 903 640 - 7900 2501 Pecan Street Fax 90 3 640 - 0535 Bonham, TX Website www.geindustrial.com Technology for the Digital World. ver 1.2 - US GT Series UPS TM[...]
-
Page 2
OPM_GTU_TWR_1K0_3K0_XUS_V015 1 DE GT Series: User manual rev date 8 - 11 - 04 Digi tal Energy ™ GT Series g USER MANUAL Digital Energy ™ GT Series Uninterruptible Power Supply 1000 – 1500 - 2000 - 3000 VA UL - version The GE (General Electric) Digital Energy™ GT Series UPS , an uninterruptible power supply, protects your equipment from all [...]
-
Page 3
OPM_GTU_TWR_1K0_3K0_XUS_V015 2 DE GT Series: User manual rev date 8 - 11 - 04 Digi tal Energy ™ GT Series g CONTENTS 1 IMPORTANT SAFETY INSTRUCTIONS ................................ ................. 3 1.1 Save these instructions 1.2 General 1.3 Installation 1.4 Batteries 1.5 Transport/storage 1.6 FCCIS Inter ference statements 2 INSTALLATION ...[...]
-
Page 4
OPM_GTU_TWR_1K0_3K0_XUS_V015 3 DE GT Series: User manual rev date 8 - 11 - 04 Digi tal Energy ™ GT Series g 1.1 Save these instructions This manual contains important instructions for the Digital Energy™ GT Series - UL UPS that should be followed during installation and maintenance of the UPS and the batteries. Before attempting to install and [...]
-
Page 5
OPM_GTU_TWR_1K0_3K0_XUS_V015 4 DE GT Series: User manual rev date 8 - 11 - 04 Digi tal Energy ™ GT Series g 1.4 Batteries • NOTE : Servicing of batteries should be performed or supervised by personnel knowledgeable of batteries and the required precautions. Keep unauthorized personnel away from batteries. • When replacing the batteries, use o[...]
-
Page 6
OPM_GTU_TWR_1K0_3K0_XUS_V015 5 DE GT Series: User manual rev date 8 - 11 - 04 Digi tal Energy ™ GT Series g 1.6 FCC IS Interference Statements 1 kVA MODEL Federal Communications Commission Interference Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. T[...]
-
Page 7
OPM_GTU_TWR_1K0_3K0_XUS_V015 6 DE GT Series: User manual rev date 8 - 11 - 04 Digi tal Energy ™ GT Series g 1000VA 7 9 5 8 6 3 2 1 3 3 8 5 9 7 6 2 1 1500 / 2000 / 3000 VA 2.1 Package contents The packing box contains a Digit al Energy™ GT Series - UL UPS , an RS232 data cable, a CD ROM and this manual. Carefully inspect the packing box and its [...]
-
Page 8
OPM_GTU_TWR_1K0_3K0_XUS_V015 7 DE GT Series: User manual rev date 8 - 11 - 04 Digi tal Energy ™ GT Series g 2.4 Installation The unit should be installed by service personnel. IMPORTANT : Before making any connection and switching on the UPS, please check the following conditions: • your mains supply is 100/110/120 Volts and 50/60Hz, • the to[...]
-
Page 9
OPM_GTU_TWR_1K0_3K0_XUS_V015 8 DE GT Series: User manual rev date 8 - 11 - 04 Digi tal Energy ™ GT Series g 2.4.3 Connecting the RS232/dry contact interface Connect t he interface signal cable between the RS - 232/dry contact port on the rear panel of UPS and COM1 or COM2 of your computer if necessary. See fig. 2.4. Refer to chapter 4 for more in[...]
-
Page 10
OPM_GTU_TWR_1K0_3K0_XUS_V015 9 DE GT Series: User manual rev date 8 - 11 - 04 Digi tal Energy ™ GT Series g Though the batteries (the internal energy reserve) were fully charged when the UPS left the factory, they might have lost some energy during transport and/or storage. It is recommended to allow the UPS to recharge the batteries for at least[...]
-
Page 11
OPM_GTU_TWR_1K0_3K0_XUS_V015 10 DE GT Series: User manual rev date 8 - 11 - 04 Digi tal Energy ™ GT Series g 8 13 12 11 10 5 3 6 4 1 9 7 2 3.1 Operation Panel 1 Switch ‘I/TEST’ - Switches on the UPS - In ‘ON - LINE’ mode it starts the battery test - In ‘ON BATTERY’ mod e it mutes the buzzer 2 Off switch Switches off the UPS 3 LED ‘B[...]
-
Page 12
OPM_GTU_TWR_1K0_3K0_XUS_V015 11 DE GT Series: User manual rev date 8 - 11 - 04 Digi tal Energy ™ GT Series g 3.2 Start - up 3.2.1 Start - up, utility power available 1 Push the ‘I/TEST’ - button (1) and hold for 3 seconds until a short beep is heard. The bypass LED will shortly light up. When the LED ‘On Line’ lights up, the UPS is runnin[...]
-
Page 13
OPM_GTU_TWR_1K0_3K0_XUS_V015 12 DE GT Series: User manual rev date 8 - 11 - 04 Digi tal Energy ™ GT Series g 3.3.4 Silencing the buzzer When the UPS is in ‘ON BATTERY’ mode the buzzer can be turned on or off by pressing the ‘I/TEST’ - button (1). 3.3.5 Switching off 1 To switch off the UPS push the OFF - button (2) until a short beep is h[...]
-
Page 14
OPM_GTU_TWR_1K0_3K0_XUS_V015 13 DE GT Series: User manual rev date 8 - 11 - 04 Digi tal Energy ™ GT Series g 3.4.4 Bypass operation If the UPS is unable to deliver the demanded output power due to overload or over - temperature, the load is switched directly to the utility supply. The LED ‘Bypass’ will light, and the buzzer will sound continu[...]
-
Page 15
OPM_GTU_TWR_1K0_3K0_XUS_V015 14 DE GT Series: User manual rev date 8 - 11 - 04 Digi tal Energy ™ GT Series g 4.1 Description The GT Series UPS is equipped with a communications interface, providing RS232 and dry contact protocols in one sub - D 9 - pin female connector located at the rear of the unit. The communication port on the UPS can be conn[...]
-
Page 16
OPM_GTU_TWR_1K0_3K0_XUS_V015 15 DE GT Series: User manual rev date 8 - 11 - 04 Digi tal Energy ™ GT Series g 4.2 RS232 The RS - 232 communication port provides the following functions: 1 - Monitoring charger status 2 - Monitoring battery status and conditio n 3 - Monitoring inverter status 4 - Monitoring UPS status 5 - Monitoring the AC utility p[...]
-
Page 17
OPM_GTU_TWR_1K0_3K0_XUS_V015 16 DE GT Series: User manual rev date 8 - 11 - 04 Digi tal Energy ™ GT Series g 4.4 SNMP Plug - in Card (optional) SNMP (Simple Network Management Protocol) is the most popular protocol in the network. Via NMS (Network Management Station) you can detect the status of all facilities in the network. An SNMP Interface Ca[...]
-
Page 18
OPM_GTU_TWR_1K0_3K0_XUS_V015 17 DE GT Series: User manual rev date 8 - 11 - 04 Digi tal Energy ™ GT Series g Apart from the SNMP - option described in 4.4 the following options are possible: 5.1 Extended Runtime Extended runtime can be obta ined by connecting a separate battery extension module to the UPS. The additional batteries increase the ru[...]
-
Page 19
OPM_GTU_TWR_1K0_3K0_XUS_V015 18 DE GT Series: User manual rev date 8 - 11 - 04 Digi tal Energy ™ GT Series g Whenever a malfunction occurs, first check external factors (e.g. connections, temperature, humidity or load) to determine whether the problem is caused by th e unit itself or by its environment. Subsequently check the thermal circuit brea[...]
-
Page 20
OPM_GTU_TWR_1K0_3K0_XUS_V015 19 DE GT Series: User manual rev date 8 - 11 - 04 Digi tal Energy ™ GT Series g GT Model 1000T UL 1500 T UL 2000T UL 3000T UL Capacity 1kVA/800W 1.5kVA/ 1200 W 2kVA/1600W 3kVA/2400W Rated Voltage 100V, 110V, 120V Voltage Range 80V ~ 138V ( full load ) ; 65 V~ 80 V (70% load ) Frequency 50Hz / 60Hz (± 4.8 Hz) Input Po[...]