GE 600 - 1500 VA manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of GE 600 - 1500 VA, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of GE 600 - 1500 VA one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of GE 600 - 1500 VA. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of GE 600 - 1500 VA should contain:
- informations concerning technical data of GE 600 - 1500 VA
- name of the manufacturer and a year of construction of the GE 600 - 1500 VA item
- rules of operation, control and maintenance of the GE 600 - 1500 VA item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of GE 600 - 1500 VA alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of GE 600 - 1500 VA, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the GE service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of GE 600 - 1500 VA.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the GE 600 - 1500 VA item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    NetPro 19" Uninterruptible Power Supply 600 - 1500 VA Manufactured by: GE Digital Energy General Electric Company Tel ephone +41 (0)91 / 850 51 51 CH – 6595 Riazz ino (Locarno) Fax +41 (0)91 / 850 51 44 Swi tz er la n d W eb s it e www. gedigitalenergy.com GE Digital Energy Techno logy for t he Digital Wo rld. ver 3.0 - GB NetPro 19" UP[...]

  • Page 2

    OPM _NPE_19X_600_1K5_2GB_V030 1 GE DE N etPro 19” 600-1500: User manual 3.0 (GB) g GE Digital Energy USER MA NUA L NetPro 19" Uninterruptible Po wer Supply Uninterruptible Po wer Supply Uninterruptible Po wer Supply Uninterruptible Po wer Supply 600 - 1500 VA 600 - 1500 VA 600 - 1500 VA 600 - 1500 VA Please read these instructions caref ully[...]

  • Page 3

    OPM _NPE_19X_600_1K5_2GB_V030 2 GE DE N etPro 19” 600-1500: User manual 3.0 (GB) g GE Digital Energy 1.1 Introduction The Gen eral Electric (GE) Digit al Energy NetPro 19” UPS , a truly on-line uninterruptible power supply, protects your equipm ent from all f orm s of power inter ferenc e, including com plete power failure s. 1.2 Safety Rules x[...]

  • Page 4

    OPM _NPE_19X_600_1K5_2GB_V030 3 GE DE N etPro 19” 600-1500: User manual 3.0 (GB) g GE Digital Energy 2.2 Installation Procedure 1. Remove the tr ansport sc rews (A, fig. 1) and store them in the f ree holes (B, f ig.1). Mount the NetPro 19” UPS in the 19” rack . The m odule m ust be suppor ted by m ounting rails, do not m ount it by using the[...]

  • Page 5

    OPM _NPE_19X_600_1K5_2GB_V030 4 GE DE N etPro 19” 600-1500: User manual 3.0 (GB) g GE Digital Energy Please ref er to figure 6. 3.1 Start-up 3.1.1 Start-up, main s available 1 Press k eypad 'I' (14, fig. 6) br iefly; LED ‘on’ (already blinking) will illuminate continuous ly now. 2 The equipm ent connec ted to the UPS can now be swit[...]

  • Page 6

    OPM _NPE_19X_600_1K5_2GB_V030 5 GE DE N etPro 19” 600-1500: User manual 3.0 (GB) g GE Digital Energy 3.3 Use: Status and A larm Indications o status indic ations : the operating m ode ! low priority alarm s : abnorm al oper ating situations !! high priority alarms : situations in which the actual output voltage of the UPS is no longer guaranteed [...]

  • Page 7

    OPM _NPE_19X_600_1K5_2GB_V030 6 GE DE N etPro 19” 600-1500: User manual 3.0 (GB) g GE Digital Energy 3.3.1 Charger on The batteries are charging, s ee 2.2 step 7. 3.3.2 On line: norma l operation See 3.2.1. 3.3.3 On bat tery The UPS us es the energy stored in the batteries: see c hapter 7 ‘Batteries - r untime’. The UPS will shutdown x after [...]

  • Page 8

    OPM _NPE_19X_600_1K5_2GB_V030 7 GE DE N etPro 19” 600-1500: User manual 3.0 (GB) g GE Digital Energy 3.3.8 High temperatu re The LED Indic ation is the sam e as dur ing overload (see 3.3.7), but if k eypad 'I' is m om entarily pressed to obtain a load indic ation the red LED will go out. Overtem perature c an be caused by: x extrem e en[...]

  • Page 9

    OPM _NPE_19X_600_1K5_2GB_V030 8 GE DE N etPro 19” 600-1500: User manual 3.0 (GB) g GE Digital Energy 3.5 Battery Management Maxim um battery life and reliability are obtained by the following features: x x x x Quick battery test The quick battery test checks whether the batteries and their wiring are healthy. If a quick battery test shows that th[...]

  • Page 10

    OPM _NPE_19X_600_1K5_2GB_V030 9 GE DE N etPro 19” 600-1500: User manual 3.0 (GB) g GE Digital Energy 4.1 RS232 Port (fig. 8) The RS 232 Port is a plug-in interf ace port ( 9-pin, Sub-D, m ale) which enables advanced com m unication between the UPS and the computer (UPS sof tware required). T he interf ace port is operative as s oon as the ma ins [...]

  • Page 11

    OPM _NPE_19X_600_1K5_2GB_V030 10 GE DE N etPro 19” 600-1500: User manual 3.0 (GB) g GE Digital Energy Apart fr om the options described in 4.2 and 4.3 the f ollowing options are poss ible: 5.1 Extended Runtime (N etPro 19” 1000) Extended runtim e can be obtained by connecting a separate battery extension pack to the UPS. In this case the UPS mu[...]

  • Page 12

    OPM _NPE_19X_600_1K5_2GB_V030 11 GE DE N etPro 19” 600-1500: User manual 3.0 (GB) g GE Digital Energy Battery replacement pro cedure Refer to the label on the battery drawer. 1. Be sure that the transport screws (A, f ig. 1) have been rem oved. 2. Remove the f ront panel of the battery com partm ent. Use a scr ew driver or pen as a lever . 3. Rem[...]

  • Page 13

    OPM _NPE_19X_600_1K5_2GB_V030 12 GE DE N etPro 19” 600-1500: User manual 3.0 (GB) g GE Digital Energy W henever a malf unction oc curs, f irst c heck external fa ctors ( e.g connections, tem per ature, hum idity or load) to determ ine whether the problem is caus ed by the unit itself or by its environment. Subs equently check the therm al circ ui[...]

  • Page 14

    OPM _NPE_19X_600_1K5_2GB_V030 13 GE DE N etPro 19” 600-1500: User manual 3.0 (GB) g GE Digital Energy NetPro 19” model : 600 1000 1500 Ratings Voltage Amperes (VA) : 600 1000 1500 with computer ty pe load W atts (W ) : 360 600 900 with resistiv e load Input thermal circuit breaker (A) : 5 5 7 Input fuse (A) : 8 8 10 Input converter AC input vol[...]