Go to page of
Similar user manuals
-
Ventilation Hood
GE ZXR7510
12 pages 0.34 mb -
Ventilation Hood
GE GE Monogram ZV750SPSS
2 pages 0.19 mb -
Ventilation Hood
GE STAINLESS STEEL PROFESSIONAL HOOD ZV30RSFSS
4 pages 0.24 mb -
Ventilation Hood
GE GE Profile PVB98SN
3 pages 0.37 mb -
Ventilation Hood
GE JV936
24 pages 0.4 mb -
Ventilation Hood
GE ZV36TSFSS
4 pages 0.09 mb -
Ventilation Hood
GE ZV830
60 pages 1.81 mb -
Ventilation Hood
GE ZVB36SN
4 pages 0.52 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of GE JVB35, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of GE JVB35 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of GE JVB35. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of GE JVB35 should contain:
- informations concerning technical data of GE JVB35
- name of the manufacturer and a year of construction of the GE JVB35 item
- rules of operation, control and maintenance of the GE JVB35 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of GE JVB35 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of GE JVB35, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the GE service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of GE JVB35.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the GE JVB35 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
Us e and Care & Installation G uide Downdraft Vent System Models: JVB34 JVB65 JVB35 JVB93 JVB64 JVB96 GE Appliances Safety Instructions .........................2 Operating Instructions, Tips Canning .............................................................3 Controls .............................................................3 Cooking Tip[...]
-
Page 2
W ARNING—TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJUR Y TO PERSONS, OBSER VE THE FOLLOWING: A. Use this unit only in the manner intended by the manufacturer . If you have questions, contact the manufacturer . B. Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power f[...]
-
Page 3
SER VICING NOTE: BE SURE ELECTRICAL POWER IS OFF BEFORE SER VICING THE UNIT . It may be necessary to remove the downdraft blower system from the cabinet in order to service components such as the blower motor or air vent mechanism. Disconnect power to the cooktop and remove it first. Reverse the steps in the Install the Downdraft section to remove [...]
-
Page 4
Gr ease Filter The efficiency of your downdraft depends on a clean filter . Frequency of cleaning depends on the type of cooking you do. Grease filters should be cleaned at least once a month. Never operate the downdraft without the filters in place. T o r emove: Pull the filters out by grasping them and pulling straight up. T o clean: Soak and the[...]
-
Page 5
5 INST ALLA TION INSTRUCTIONS Before Starting Installation Check the Following Requirements This downdraft blower system is designed to be used to exhaust smoke and odors when cooking with all GE electric and sealed bur ner gas cooktops (not approved for standar d bur ner gas cooktops). It can be mounted in either an island or peninsula location. R[...]
-
Page 6
30 ″ COOKT OPS/DOWNDRAFT UNITS JVB34, JVB35, JVB93 Figure 2 Overall Cutout Dimensions Figure 3 Cutout for Vent Figure 1 Overall Cooktop Dimensions 1 2 3 NOTE: AGAINST -THE-W ALL INST ALLA TIONS ARE LIMITED DUE TO DIMENSION REQUIREMENTS. REFER TO DET AILS BELOW . PLANNING INSTALLATION (Note: 26 ″ deep cabinets required) PREPARING CUTOUT A B C B&[...]
-
Page 7
7 36 ″ COOKT OPS/DOWNDRAFT UNITS JVB64, JVB65, JVB96 Figure 2 Overall Cutout Dimensions Figure 3 Cutout for Vent Figure 1 Overall Cooktop Dimensions 1 2 3 NOTE: AGAINST -THE-W ALL INST ALLA TIONS ARE LIMITED DUE TO DIMENSION REQUIREMENTS. REFER TO DET AILS BELOW . PLANNING INSTALLATION (Note: 26 ″ deep cabinets required) PREPARING CUTOUT A B C [...]
-
Page 8
INST ALLA TION INSTRUCTIONS (continued) 8 Plan the Ductwork 1. This downdraft blower system is designed for use with 3 1 ⁄ 4 ″ x 10 ″ ductwork (can be transitioned to 6 ″ round). Three dif ferent discharge directions ar e available with side--to-side adjustment for accurate alignment of ductwork. 2. For best per for mance: Choose the ductin[...]
-
Page 9
9 Plan the Wiring 1. The downdraft blower system draws 4 AMPS and requires a 120 V AC, 60 Hz cir cuit. 2. The unit has a 2 ft. long power cord with a 3-pronged plug. Plan to provide a gr ounded outlet in a location which will allow the unit’s power cord to r each. The outlet cannot be located on a back wall. The outlet needs to be mounted on the [...]
-
Page 10
10 INST ALLA TION INSTRUCTIONS (continued) Install the Downdraft 1. Set the downdraft into the opening. Extend the leveling brackets to the floor of the cabinet so the downdraft sits straight. ( NOTE: Leveling brackets can be removed and r e-attached in other positions. The bottom flange may have to face inward in tight cabinet installations.) 2. S[...]
-
Page 11
1 1 Adjust the Switch The downdraft is factor y-adjusted for pr oper operation. However , shipping and handling may af fect the positions of the activating switch. T o adjust position of activating switch: 1. If the downdraft is plugged into the electrical outlet, unplug it. 2. Lift the air vent straight up and cock it slightly so it remains in the[...]
-
Page 12
WHA T IS COVERED FULL ONE-YEAR W ARRANTY For one year from date of original purchase, we will provide, free of charge, parts and service labor in your home to repair or replace any part of the downdraft system that fails because of a manufacturing defect. This warranty is extended to the original purchaser and any succeeding owner for products purc[...]