Go to page of
Similar user manuals
-
Air Conditioner
Goodman Mfg CKLB24-1G
8 pages 0.37 mb -
Air Conditioner
Goodman Mfg DSXC16
32 pages 0.77 mb -
Air Conditioner
Goodman Mfg IO-354B
27 pages 0.59 mb -
Air Conditioner
Goodman Mfg ARPT
13 pages 0.3 mb -
Air Conditioner
Goodman Mfg Air Handler with Painted Cabinet
8 pages 0.69 mb -
Air Conditioner
Goodman Mfg 10.3 EER
12 pages 0.55 mb -
Air Conditioner
Goodman Mfg SS-CE120
8 pages 0.26 mb -
Air Conditioner
Goodman Mfg ATUF
20 pages 0.33 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Goodman Mfg GPC14H, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Goodman Mfg GPC14H one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Goodman Mfg GPC14H. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Goodman Mfg GPC14H should contain:
- informations concerning technical data of Goodman Mfg GPC14H
- name of the manufacturer and a year of construction of the Goodman Mfg GPC14H item
- rules of operation, control and maintenance of the Goodman Mfg GPC14H item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Goodman Mfg GPC14H alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Goodman Mfg GPC14H, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Goodman Mfg service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Goodman Mfg GPC14H.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Goodman Mfg GPC14H item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
SS-GPC14H www .goodmanmfg.com 7/11 Supersedes 6/11 Product Featur es • Energ y-efcientcompressor withinternalrelief valve • EEMblowermotor • Quiethorizontaldischarge • Coppertube/aluminumncoil • T otall yenclosed,permanentlylubricated condenserfanmotor ?[...]
-
Page 2
P RoDUcT S PeciFicA TionS P RoDUcT S PeciFicA TionS 2 www .goodmanmfg.com SS-GPC14H n omenclA TURe Brand Engineering G Goodman Minor Revision or Distinctions™ Product Category Engineering P Packaged Unit Major Revision Type Voltage Designator H Heat Pump 1 208-230/1/60 C Air Conditioner 3 208-230/3/60 4 460/3/60 Efficiency Refrigerant 13 13 SEER [...]
-
Page 3
P roduct S Pecifica tionS P roduct S Pecifica tionS SS-GPC14H www .goodmanmfg.com 3 S Pecifica tionS Models GPC14 24H41AC GPC14 30H41AA GPC14 30H41AC GPC14 36H41AA GPC14 36H41AC Cooling Cap acity Cooling Capacity (BTU/h) 24,600 28,400 28,400 35,600 35,600 Sensible BTU/h 18,200 21,600 21,600 27,100 27,100 SEER / EER 14.5 / 12.1 14.0 / 12.1 14.0 / 12[...]
-
Page 4
P RoDUcT S PeciFicA TionS P RoDUcT S PeciFicA TionS 4 www .goodmanmfg.com SS-GPC14H S PeciFicA TionS Models GPC14 42H41AA GPC14 42H41AC GPC14 48H41AA GPC14 48H41AC GPC14 60H41A* Cooling Cap acity Cooling Capacity (BTU/h) 40,000 40,000 46,500 46,500 57,500 Sensible BTU/h 30,400 30,400 35,300 35,300 40,800 SEER / EER 14.2 / 12.0 14.2 / 12.0 14.5 / 12[...]
-
Page 5
P RoDUcT S PeciFicA TionS P RoDUcT S PeciFicA TionS SS-GPC14H www .goodmanmfg.com 5 A iRFl ow D A T A Model Speed V ol ts E.S.P . (In. of H₂O) 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 GPC14 24H41** T1 230 CFM 934 759 755 638 581 489 - - 95 77 76 73 83 90 - - T2, T3 230 CFM 990 837 801 744 696 652 601 - 107 94 105 110 119 133 14[...]
-
Page 6
P RoDUcT S PeciFicA TionS P RoDUcT S PeciFicA TionS 6 www .goodmanmfg.com SS-GPC14H e xP AnDeD c ooling D A TA — gPc1 424H4 1Ac Outdoor Ambient Temper a ture 65 75 85 95 105 115 Entering Indoor Wet Bulb Temper ature IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 70 920 MBh 24.1 25.0 27.4 - 23.5 24.4 26.7 - 23.[...]
-
Page 7
P RoDUcT S PeciFicA TionS P RoDUcT S PeciFicA TionS SS-GPC14H www .goodmanmfg.com 7 e xP AnDeD c ooling D A TA — gPc1 424H4 1Ac ( conT .) Outdoor Ambient Temper a ture 65 75 85 95 105 115 Entering Indoor Wet Bulb Temper ature IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 80 920 MBh 25.0 25.5 27.2 29.1 24.4 24[...]
-
Page 8
P RoDUcT S PeciFicA TionS P RoDUcT S PeciFicA TionS 8 www .goodmanmfg.com SS-GPC14H e xP AnDeD c ooling D A TA — gPc1 430H4 1AA Outdoor Ambient Temper a ture 65 75 85 95 105 115 Entering Indoor Wet Bulb Temper ature IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 70 1180 MBh 27.8 28.8 31.6 - 27.2 28.2 30.9 - 26[...]
-
Page 9
P RoDUcT S PeciFicA TionS P RoDUcT S PeciFicA TionS SS-GPC14H www .goodmanmfg.com 9 e xP AnDeD c ooling D A TA — gPc1 430H4 1AA ( conT .) Outdoor Ambient Temper a ture 65 75 85 95 105 115 Entering Indoor Wet Bulb Temper ature IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 80 1180 MBh 28.8 29.4 31.4 33.6 28.1 2[...]
-
Page 10
P RoDUcT S PeciFicA TionS P RoDUcT S PeciFicA TionS 10 www .goodmanmfg.com SS-GPC14H e xP AnDeD c ooling D A TA — gPc1 430H4 1Ac Outdoor Ambient Temper a ture 65 75 85 95 105 115 Entering Indoor Wet Bulb Temper ature IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 70 1145 MBh 27.8 28.8 31.6 - 27.2 28.2 30.9 - 2[...]
-
Page 11
P RoDUcT S PeciFicA TionS P RoDUcT S PeciFicA TionS SS-GPC14H www .goodmanmfg.com 11 e xP AnDeD c ooling D A TA — gPc1 430H4 1Ac ( conT .) Outdoor Ambient Temper a ture 65 75 85 95 105 115 Entering Indoor Wet Bulb Temper ature IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 80 1145 MBh 28.8 29.4 31.4 33.6 28.1 [...]
-
Page 12
P RoDUcT S PeciFicA TionS P RoDUcT S PeciFicA TionS 12 www .goodmanmfg.com SS-GPC14H e xP AnDeD c ooling D A TA — gPc1 436H4 1AA Outdoor Ambient Temper a ture 65 75 85 95 105 115 Entering Indoor Wet Bulb Temper ature IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 70 1349 MBh 34.9 36.2 39.6 - 34.1 35.3 38.7 - 3[...]
-
Page 13
P RoDUcT S PeciFicA TionS P RoDUcT S PeciFicA TionS SS-GPC14H www .goodmanmfg.com 13 e xP AnDeD c ooling D A TA — gPc1 436H4 1AA ( conT .) Outdoor Ambient Temper a ture 65 75 85 95 105 115 Entering Indoor Wet Bulb Temper ature IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 80 1349 MBh 36.1 36.9 39.4 42.1 35.3 [...]
-
Page 14
P RoDUcT S PeciFicA TionS P RoDUcT S PeciFicA TionS 14 www .goodmanmfg.com SS-GPC14H e xP AnDeD c ooling D A TA — gPc1 436H4 1Ac Outdoor Ambient Temper a ture 65 75 85 95 105 115 Entering Indoor Wet Bulb Temper ature IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 70 1350 MBh 35.8 37.1 40.7 - 35.0 36.3 39.8 - 3[...]
-
Page 15
P RoDUcT S PeciFicA TionS P RoDUcT S PeciFicA TionS SS-GPC14H www .goodmanmfg.com 15 e xP AnDeD c ooling D A TA — gPc1 436H4 1Ac ( conT .) Outdoor Ambient Temper a ture 65 75 85 95 105 115 Entering Indoor Wet Bulb Temper ature IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 80 1350 MBh 37.1 37.9 40.5 43.3 36.2 [...]
-
Page 16
P RoDUcT S PeciFicA TionS P RoDUcT S PeciFicA TionS 16 www .goodmanmfg.com SS-GPC14H Outdoor Ambient Temper a ture 65 75 85 95 105 115 Entering Indoor Wet Bulb Temper ature IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 70 1461 MBh 39.7 41.1 45.1 - 38.8 40.2 44.0 - 37.8 39.2 43.0 - 36.9 38.3 41.9 - 35.1 36.4 39.[...]
-
Page 17
P RoDUcT S PeciFicA TionS P RoDUcT S PeciFicA TionS SS-GPC14H www .goodmanmfg.com 17 Outdoor Ambient Temper a ture 65 75 85 95 105 115 Entering Indoor Wet Bulb Temper ature IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 80 1461 MBh 41.1 42.0 44.8 47.9 40.1 41.0 43.8 46.8 39.2 40.0 42.8 45.7 38.2 39.0 41.7 44.6 3[...]
-
Page 18
P RoDUcT S PeciFicA TionS P RoDUcT S PeciFicA TionS 18 www .goodmanmfg.com SS-GPC14H e xP AnDeD c ooling D A TA — gPc1 442H41A c Outdoor Ambient Temper a ture 65 75 85 95 105 115 Entering Indoor Wet Bulb Temper ature IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 70 1432 MBh 39.8 41.3 45.2 - 38.9 40.3 44.1 - 3[...]
-
Page 19
P RoDUcT S PeciFicA TionS P RoDUcT S PeciFicA TionS SS-GPC14H www .goodmanmfg.com 19 e xP AnDeD c ooling D A TA — gPc1 442H41A c ( conT .) Outdoor Ambient Temper a ture 65 75 85 95 105 115 Entering Indoor Wet Bulb Temper ature IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 80 1432 MBh 41.2 42.1 45.0 48.1 40.2 [...]
-
Page 20
P RoDUcT S PeciFicA TionS P RoDUcT S PeciFicA TionS 20 www .goodmanmfg.com SS-GPC14H e xP AnDeD c ooling D A TA — gPc1 448H41AA Outdoor Ambient Temper a ture 65 75 85 95 105 115 Entering Indoor Wet Bulb Temper ature IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 70 1800 MBh 45.6 47.2 51.7 - 44.5 46.1 50.5 - 43[...]
-
Page 21
P RoDUcT S PeciFicA TionS P RoDUcT S PeciFicA TionS SS-GPC14H www .goodmanmfg.com 21 e xP AnDeD c ooling D A TA — gPc1 448H41AA ( conT .) Outdoor Ambient Temper a ture 65 75 85 95 105 115 Entering Indoor Wet Bulb Temper ature IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 80 1800 MBh 47.2 48.2 51.5 55.0 46.1 4[...]
-
Page 22
P RoDUcT S PeciFicA TionS P RoDUcT S PeciFicA TionS 22 www .goodmanmfg.com SS-GPC14H e xP AnDeD c ooling D A TA — gPc1 448H41A c Outdoor Ambient Temper a ture 65 75 85 95 105 115 Entering Indoor Wet Bulb Temper ature IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 70 1777 MBh 46.1 47.8 52.4 - 45.1 46.7 51.2 - 4[...]
-
Page 23
P RoDUcT S PeciFicA TionS P RoDUcT S PeciFicA TionS SS-GPC14H www .goodmanmfg.com 23 e xP AnDeD c ooling D A TA — gPc1 448H41A c ( conT .) Outdoor Ambient Temper a ture 65 75 85 95 105 115 Entering Indoor Wet Bulb Temper ature IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 80 1777 MBh 47.7 48.8 52.1 55.7 46.6 [...]
-
Page 24
P RoDUcT S PeciFicA TionS P RoDUcT S PeciFicA TionS 24 www .goodmanmfg.com SS-GPC14H e xP AnDeD c ooling D A TA — gPc1 460H41A * Outdoor Ambient Temper a ture 65 75 85 95 105 115 Entering Indoor Wet Bulb Temper ature IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 70 1800 MBh 56.3 58.4 64.0 - 55.0 57.0 62.5 - 5[...]
-
Page 25
P RoDUcT S PeciFicA TionS P RoDUcT S PeciFicA TionS SS-GPC14H www .goodmanmfg.com 25 e xP AnDeD c ooling D A TA — gPc1 460H41A * ( conT .) Outdoor Ambient Temper a ture 65 75 85 95 105 115 Entering Indoor Wet Bulb Temper ature IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 80 1800 MBh 58.3 59.6 63.7 68.1 57.0 [...]
-
Page 26
P RoDUcT S PeciFicA TionS P RoDUcT S PeciFicA TionS 26 www .goodmanmfg.com SS-GPC14H H eA T k iT e lecTRicAl D AT A (B loweR o nl y , H eA T m oDe ) Model and Hea t Kit Usage Cir cuit #1 Circuit #2 A c tual kW / BTU@ 240V MCA¹ MOD² MCA¹ MOD² GPC1424H41* 1.5 / 1.5 -- -- -- -- HKR-05*, HKR-05C* 24 / 27 30 / 30 -- -- 4.75 / 16,200 HKR-08*, HKR-08C[...]
-
Page 27
P RoDUcT S PeciFicA TionS P RoDUcT S PeciFicA TionS SS-GPC14H www .goodmanmfg.com 27 D imenSionS m inimAl c leARAnceS A Dimensions Model Chassis Size Height GPC1424 GPC1430 GPC1436 GPC1442 GPC1448 GPC1460 38¾ A[...]
-
Page 28
P RoDUcT S PeciFicA TionS P RoDUcT S PeciFicA TionS 28 www .goodmanmfg.com SS-GPC14H w iRing D iA gRAm — gPc1 42 4-60H4 1AA Wiring is subject to change. Always refer to the wiring diagram or the unitforthe mostup-to-datewiring . ⚠ W arninG High V oltage: Disconnect all power bef[...]
-
Page 29
P RoDUcT S PeciFicA TionS P RoDUcT S PeciFicA TionS SS-GPC14H www .goodmanmfg.com 29 w iRing D iA gRAm — gPc1 42 4-48H4 1A c Wiring is subject to change. Always refer to the wiring diagram or the unitforthe mostup-to-datewiring . ⚠ W arninG High V oltage: Disconnect all power be[...]
-
Page 30
P RoDUcT S PeciFicA TionS P RoDUcT S PeciFicA TionS 30 www .goodmanmfg.com SS-GPC14H A cceSSoRieS Item Descrip tion OT /EHR18-60 Emergency Heat R elay kit OT18-60A Out door Thermostat Kit with Lock out Stat PCCP102/103 Roof Curb f or for Medium/Large Chassis PCE102/103 Downow Ec onomizer for f or Medium/Large Chassis PCEF102/103 Elbow & Flas[...]
-
Page 31
P RoDUcT S PeciFicA TionS P RoDUcT S PeciFicA TionS SS-GPC14H www .goodmanmfg.com 31 n o TeS[...]
-
Page 32
P RoDUcT S PeciFicA TionS P RoDUcT S PeciFicA TionS 32 www .goodmanmfg.com SS-GPC14H Goodman Manufacturing Company , L.P ., reserves the right to discontinue, or change a t any time, specications or desig ns without notice or without incurring obligations. © 2011 • Goodman Manufacturing Company , L.P . • Houston, T exas • Printed in the U[...]