Goodman Mfg SS-CPH90-150 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Goodman Mfg SS-CPH90-150, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Goodman Mfg SS-CPH90-150 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Goodman Mfg SS-CPH90-150. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Goodman Mfg SS-CPH90-150 should contain:
- informations concerning technical data of Goodman Mfg SS-CPH90-150
- name of the manufacturer and a year of construction of the Goodman Mfg SS-CPH90-150 item
- rules of operation, control and maintenance of the Goodman Mfg SS-CPH90-150 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Goodman Mfg SS-CPH90-150 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Goodman Mfg SS-CPH90-150, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Goodman Mfg service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Goodman Mfg SS-CPH90-150.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Goodman Mfg SS-CPH90-150 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    SS-CPH90-150 ww w .goodmanmfg.c om 6/11 Supersedes 3/11 Standard Featur es • R-410Achlorine -freerefrigerant • High- eciencyscrollcompressor • Coppertube/aluminumncoils • Contactorwithlugs • High- capacity,st eel- casedlterdryer • Single -pointentry • 24-volt?[...]

  • Page 2

    P roduCt S PeCifiCa tionS P roduCt S PeCifiCa tionS 2 ww w .goodmanmfg.c om SS-CPH90-150 n omenCla ture  C P H 090 045 3 B X X X           Brand F actoryInstalledOp<ons      ?[...]

  • Page 3

    P roduCt S PeCifiCa tionS P roduCt S PeCifiCa tionS SS-CPH90-150 ww w .goodmanmfg.c om 3 P roduCt S PeCifiCa tionS — 7½ t onS CPH090 ***3B*** CPH090 ***4B*** CPH090 ***7B*** Cooling Cap a city T otal BTU/h 90,000 90,000 90,000 Sensible BTU/h 65,700 65,700 65,700 EER / IEER 11.5 / 11.2 11.5 / 11.2 11.5 / 11.2 IPL V 12.30 12.30 12.30 Decibels 83 8[...]

  • Page 4

    P roduCt S PeCifiCa tionS P roduCt S PeCifiCationS 4 ww w .goodmanmfg.c om SS-CPH90-150 P roduCt S PeCifiCa tionS — 8½ t onS CPH102 ***3B*** CPH102 ***4B*** CPH102 ***7B*** Cooling Cap acity T otal, BTU/h 102,000 102,000 102,000 Sensible BTU/h 73,440 73,440 73,440 EER / IEER 11.1 / 11.2 11.1 / 11.2 11.1 / 11.2 Decibels 83 83 83 ARI Ref erence #s[...]

  • Page 5

    P roduCt S PeCifiCa tionS P roduCt S PeCifiCationS SS-CPH90-150 ww w .goodmanmfg.c om 5 P roduCt S PeCifiCa tionS — 1 0 t onS CPH120 ***3B*** CPH120 ***4B*** CPH120 ***7B*** Cooling Cap acity T otal BTU/h 118,000 118,000 118,000 Sensible BTU/h 87,300 87,300 87,300 EER / IEER 11.5 / 11.5 11.5 / 11.5 11.5 / 11.5 Decibels 83 83 83 Hea ting Cap acity[...]

  • Page 6

    P roduCt S PeCifiCa tionS P roduCt S PeCifiCationS 6 ww w .goodmanmfg.c om SS-CPH90-150 P roduCt S PeCifiCa tionS — 12½ t onS CPH150XXX 3BXXX CPH150XXX 4BXXX CPH150XXX 7BXXX Cooling Cap acity T otal, BTU/h 146,000 146,000 146,000 Sensible BTU/h 102,200 102,200 102,200 EER / IPL V 10.8 / 11.2 10.8 / 11.2 10.8 / 11.2 Decibels 83 83 83 ARI Ref eren[...]

  • Page 7

    P roduCt S PeCifiCa tionS P roduCt S PeCifiCationS SS-CPH90-150 ww w .goodmanmfg.c om 7 e xP anded H eating d a ta CPH090 Outdoor Ambient Temper a ture 65 60 55 50 47 45 40 35 30 25 20 17 15 10 5 0 -5 -10 MBh 114.4 108.3 101.9 95.3 91.0 88.2 81.9 75.5 70.5 65.0 59.9 56.6 54.5 48.9 43.3 37.8 32.2 26.4 T/ R 35.3 33.4 31.5 29.4 28.1 27.2 25.3 23.3 21.[...]

  • Page 8

    P roduCt S PeCifiCa tionS P roduCt S PeCifiCationS 8 ww w .goodmanmfg.c om SS-CPH90-150 e xP anded C ooling d at a — 7½ t onS Outdoor Ambient Temper a ture 65 75 85 95 105 115 Entering Indoor Wet Bulb Temper a ture IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 70 3375 MBh 88.2 91.4 100.2 - 86.1 89.3 97.8 - 8[...]

  • Page 9

    P roduCt S PeCifiCa tionS P roduCt S PeCifiCationS SS-CPH90-150 ww w .goodmanmfg.c om 9 e xP anded C ooling d at a — 7½ t onS ( Cont .) Outdoor Ambient Temper a ture 65 75 85 95 105 115 Entering Indoor Wet Bulb Temper a ture IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 80 3375 MBh 91.3 93.3 99.7 106.5 89.2 [...]

  • Page 10

    P roduCt S PeCifiCa tionS P roduCt S PeCifiCationS 10 ww w .goodmanmfg.c om SS-CPH90-150 e xP anded C ooling d at a — 8½ t onS Outdoor Ambient Temper a ture 65 75 85 95 105 115 Entering Indoor Wet Bulb Temper a ture IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 70 3820 MBh 100.0 103.6 113.5 - 97.6 101.2 110.[...]

  • Page 11

    P roduCt S PeCifiCa tionS P roduCt S PeCifiCationS SS-CPH90-150 ww w .goodmanmfg.c om 11 e xP anded C ooling d at a — 8½ t onS ( Cont .) Outdoor Ambient Temper a ture 65 75 85 95 105 115 Entering Indoor Wet Bulb Temper a ture IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 80 3820 MBh 103.5 105.7 112.9 120.7 1[...]

  • Page 12

    P roduCt S PeCifiCa tionS P roduCt S PeCifiCationS 12 ww w .goodmanmfg.c om SS-CPH90-150 e xP anded C ooling d at a — 1 0 t onS Outdoor Ambient Temper a ture 65 75 85 95 105 115 Entering Indoor Wet Bulb Temper a ture IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 70 4500 MBh 115.6 119.8 131.3 - 112.9 117.1 128[...]

  • Page 13

    P roduCt S PeCifiCa tionS P roduCt S PeCifiCationS SS-CPH90-150 ww w .goodmanmfg.c om 13 e xP anded C ooling d at a — 1 0 t onS ( Cont .) Outdoor Ambient Temper a ture 65 75 85 95 105 115 Entering Indoor Wet Bulb Temper a ture IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 80 4500 MBh 119.7 122.3 130.7 139.7 1[...]

  • Page 14

    P roduCt S PeCifiCa tionS P roduCt S PeCifiCationS 14 ww w .goodmanmfg.c om SS-CPH90-150 e xP anded C ooling d at a — 12½ t onS Outdoor Ambient Temper a ture 65 75 85 95 105 115 Entering Indoor Wet Bulb Temper a ture IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 70 4725 MBh 143.1 148.3 162.5 - 139.7 144.8 15[...]

  • Page 15

    P roduCt S PeCifiCa tionS P roduCt S PeCifiCationS SS-CPH90-150 ww w .goodmanmfg.c om 15 e xP anded C ooling d at a — 12½ t onS ( Cont .) Outdoor Ambient Temper a ture 65 75 85 95 105 115 Entering Indoor Wet Bulb Temper a ture IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 80 4725 MBh 148.1 151.3 161.7 172.8 [...]

  • Page 16

    P roduCt S PeCifiCa tionS P roduCt S PeCifiCationS 16 ww w .goodmanmfg.c om SS-CPH90-150 a irfl ow d a ta — 7½ t onS St andard Bel t Drive — Down Sho t ESP , In H 2 O T urns Open 012345 CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP 0.1 3617 704 1.07 3293 653 0.84 0.3 3541 749 1.15 3179 704 0.88 2757 656 0.66 0.5 3447 [...]

  • Page 17

    P roduCt S PeCifiCa tionS P roduCt S PeCifiCationS SS-CPH90-150 ww w .goodmanmfg.c om 17 a irfl ow d a ta — 8½ t onS St andard Bel t Drive — Down Sho t ESP , In H 2 O T urns Open 012345 CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP 0.1 3467 701 1.04 3143 650 0.81 0.3 3391 746 1.12 3029 701 0.85 2607 653 0.63 0.5 3297 [...]

  • Page 18

    P roduCt S PeCifiCa tionS P roduCt S PeCifiCationS 18 ww w .goodmanmfg.c om SS-CPH90-150 a irfl ow d a ta — 1 0 t onS St andard Bel t Drive — Down sho t ESP , In H 2 O T urns Open 012345 CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP 0.2 4629 774 1.76 4269 733 1.42 0.4 4539 824 1.86 4198 781 1.53 3797 735 1.21 0.6 4511 [...]

  • Page 19

    P roduCt S PeCifiCa tionS P roduCt S PeCifiCationS SS-CPH90-150 ww w .goodmanmfg.c om 19 a irfl ow d a ta — 12½ t onS St andard Bel t Drive --- Down Sho t ESP (in W .C.) T urns Open 0 1 2 3 4 5 CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP 0.2 5378 2.35 4967 1.92 4710 1.59 4512 1.33 0.4 5514 2.92 5349 2.56 4750 1.97 4583 1.71 4319 1.40 4030 1.[...]

  • Page 20

    P roduCt S PeCifiCa tionS P roduCt S PeCifiCationS 20 ww w .goodmanmfg.c om SS-CPH90-150 H ea t k it e leCtriCal d a t a — 7½ t onS m inimum a irflow for e leCtriC H ea t Hea ter Size (kW) Minimum CFM 15 3,000 30 3,000 43 3,000 kW Correction F actor f or 3-Phase Units Suppl y Vol t age 240 230 220 210 208 Correction F actor 1 0.93 0.82 0.78 0.76[...]

  • Page 21

    P roduCt S PeCifiCa tionS P roduCt S PeCifiCationS SS-CPH90-150 ww w .goodmanmfg.c om 21 H ea t k it e leCtriCal d a t a — 8½ t onS Model and Hea t Kit Usage MCA¹ a t 240V MOP² (amps) a t 240V Actu al kW a t 240V Recommended Airflow Range (Downsho t) Recommended Airflow Range (Horizont al) CPH102***3B*** 43 50 EHK3-16 88 90 15 3400 - 3825 CFM [...]

  • Page 22

    P roduCt S PeCifiCa tionS P roduCt S PeCifiCationS 22 ww w .goodmanmfg.c om SS-CPH90-150 H ea t k it e leCtriCal d a t a — 1 0 t onS k w C orreCtion f aCt or kW Corre ction Fa ctor (for 1- & 3-Pha se Units) Supply V oltage 240 230 220 210 208 Correcon F actor 1 0.93 0.82 0.78 0.76 kW Corre ction Fa ctor for 480V Unit s Actual V oltage 460 [...]

  • Page 23

    P roduCt S PeCifiCa tionS P roduCt S PeCifiCationS SS-CPH90-150 ww w .goodmanmfg.c om 23 H ea t k it e leCtriCal d a t a — 12½ t onS kW Corre ction Fa ctor for 1- & 3-Pha se Units Suppl y V ol t age 240 230 220 210 208 Corre ction Fa ctor 1 0.93 0.82 0.78 0.76 kW Corre ction Fa ctor for 480V Unit s Suppl y V ol t age 460 440 430 Corre ction [...]

  • Page 24

    P roduct S Pecifica tionS P roduct S PecificationS 24 ww w .goodmanmfg.c om SS-CPH90-150 d imenSionS 20 APPENDIX C UNIT DIMENSIONS Horizontal Discharge Vertical Discharge (Bottom of Unit) RETURN SUPPL Y 13 7/ 8” 28 3/ 8” 7 3/8” 12 5/ 8” 6 1/4 ” 36 3/ 8” 5 7/8 ” RETURN SUP PL Y 5 3/8” 7 1/2” 6 1/2” 99 1/ 8” 61 3/ 4” Y NOTE Fo[...]

  • Page 25

    P roduct S Pecifica tionS P roduct S PecificationS SS-CPH90-150 ww w .goodmanmfg.c om 25 48” 36” Min. 48” 48” 75” u nit c learanceS e lectrical e ntrance l oca tionS 11⅝” 10 3 / 16 ” 3” Low -V oltage Entr ance High-V oltage En trance Dimples Mark Drill Locaons Maintain an adequate clearance around the unit for saf ety, service,[...]

  • Page 26

    P roduct S Pecifica tionS P roduct S PecificationS 26 ww w .goodmanmfg.c om SS-CPH90-150 r oof c urb i nSt alla tion — r igging Pr ovisions for forks hav e been included in the unit base frame. No other fork locations are appr oved. • Unit must be lifted by the four lifting holes located at the base frame corners. • Lifting cables shoul[...]

  • Page 27

    P roduCt S PeCifiCa tionS P roduCt S PeCifiCationS SS-CPH90-150 ww w .goodmanmfg.c om 27 r oof C urB i nSt alla tion ( Cont .) Curb installations must comply with local codes and should follow the establishedguidelinesoftheNationalRoongContractorsAssociation. Pr operunit installation[...]

  • Page 28

    P roduCt S PeCifiCa tionS P roduCt S PeCifiCationS 28 ww w .goodmanmfg.c om SS-CPH90-150 w iring d ia gram — CPH090- 120***3B/ 4B ( for modelS witH Serial numBerS 090 7 and Below ) Wiring is subject to change. Alwa ys ref er to the wiring diagram or the unit for the most up-t o-date wiring. ⚠ W arning High Volt age:  [...]

  • Page 29

    P roduCt S PeCifiCa tionS P roduCt S PeCifiCationS SS-CPH90-150 ww w .goodmanmfg.c om 29 w iring d ia gram — CPH090- 120***3B/ 4B ( Cont .) ( for modelS witH Serial numBerS 090 7 and Below ) Wiring is subject to change. Alwa ys ref er to the wiring diagram or the unit for the most up-t o-date wiring. ⚠ W arning High Volt age:  ?[...]

  • Page 30

    P roduCt S PeCifiCa tionS P roduCt S PeCifiCationS 30 ww w .goodmanmfg.c om SS-CPH90-150 w iring d ia gram — CPH090- 120***3B/ 4B/ 7B*** TB1 OR BR REPLACE JUMP ER WI TH SMOKE/FIRE DETECTOR RD C 3 BL 1 PK 240 460 BL OR RD GR BK OR RD OR RD RD RD 6 GND COM HVDR R DFT1 L3 BK T3 YL NOTE 3 PLF NC NO BK UP RD GR BK 2 C WH C 8 L2 K1 BK BR DF2 C YL SPEED[...]

  • Page 31

    P roduCt S PeCifiCa tionS P roduCt S PeCifiCationS SS-CPH90-150 ww w .goodmanmfg.c om 31 w iring d ia gram — CPH090- 120***3B/ 4B/ 7B*** ( Cont .) R EBTDR BC R HVDR Y RVC1 SEE UNIT RATING PLATE FOR TYPE AND SIZE 5 OF OVER CU RRENT PROTECTION 4 BLOW ER CONTACTOR COMPRESSOR CONTACTOR CONDENSER MOT OR CONDENSER M OTOR CONTACTOR COMPRESSOR DEFROST CO[...]

  • Page 32

    P roduCt S PeCifiCa tionS P roduCt S PeCifiCationS 32 ww w .goodmanmfg.c om SS-CPH90-150 TB1 OR BR REPLACE JUMP ER WITH SMOKE/FIRE DE TECTOR RD C 3 BL 1 PK 240 460 BL OR RD GR BK OR RD OR RD RD RD 6 GND COM HVDR R DFT1 L3 BK T3 YL NOTE 3 PLF NC NO BK UP RD GR BK 2 C WH C 8 L2 K1 BK BR DF2 C YL SPEED R RVC1 DC BK RD YL L1 O 5 7 BL K1 BK M1 LPS2 XFMR[...]

  • Page 33

    P roduCt S PeCifiCa tionS P roduCt S PeCifiCationS SS-CPH90-150 ww w .goodmanmfg.c om 33 w iring d ia gram — CPH1 50***3B/ 4B/ 7B*** ( Cont .) R EBTDR BC R HVDR Y RVC1 SEE UNIT RATING PLATE FOR TYPE AN D SIZE 5 OF OVER CUR RENT PROTECTION 4 BLOW ER CONTACTOR COMPRESSOR CO NTACTOR CONDENSER MOTOR CONDENSER MO T OR CONTACTOR COMPRESSOR DEFROST CONT[...]

  • Page 34

    P roduCt S PeCifiCa tionS P roduCt S PeCifiCationS 34 ww w .goodmanmfg.c om SS-CPH90-150 a CCeSSorieS Item # Description Fits Model Sizes 14CURB90150 Roof Curb 14" T all 7½-12½ tons 25FD90150 25% Manual Fresh Air Damper 7½-12½ tons 25MFD90150 25% Motoriz ed Fresh Air Damper 7½-12½ tons BRD3672 Horizontal Bar ometric Relief Damper (two r [...]

  • Page 35

    P roduCt S PeCifiCa tionS P roduCt S PeCifiCationS SS-CPH90-150 ww w .goodmanmfg.c om 35 n o teS[...]

  • Page 36

    P roduct S Pecifica tionS P roduct S PecificationS 36 ww w .goodmanmfg.c om SS-CPH90-150 Goodman Manufacturing Company, L.P ., reser ves the right to discontinue, or change at an y time, specications or designs without noticeorwithoutincurringobligations.©2010•GoodmanManufacturingCompany,L.P .•?[...]