Go to page of
Similar user manuals
-
Air Conditioner
Goodman Mfg R-410A
26 pages 0.48 mb -
Air Conditioner
Goodman Mfg GPG13M
24 pages 1.02 mb -
Air Conditioner
Goodman Mfg GPC14H
32 pages 0.85 mb -
Air Conditioner
Goodman Mfg ARUF496116CA
10 pages 0.25 mb -
Air Conditioner
Goodman Mfg IO - 395
16 pages 0.59 mb -
Air Conditioner
Goodman Mfg AEPT
13 pages 0.3 mb -
Air Conditioner
Goodman Mfg AVPTC313714AA
6 pages 0.14 mb -
Air Conditioner
Goodman Mfg CKLB24-1E
8 pages 0.37 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Goodman Mfg RS6300011, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Goodman Mfg RS6300011 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Goodman Mfg RS6300011. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Goodman Mfg RS6300011 should contain:
- informations concerning technical data of Goodman Mfg RS6300011
- name of the manufacturer and a year of construction of the Goodman Mfg RS6300011 item
- rules of operation, control and maintenance of the Goodman Mfg RS6300011 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Goodman Mfg RS6300011 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Goodman Mfg RS6300011, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Goodman Mfg service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Goodman Mfg RS6300011.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Goodman Mfg RS6300011 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
GPC 14 SEER R-410A Package Air Conditioners with R-410A Copyright © 2009 - 2010 Goodman Manufacturing Company, L.P. RT6322007r6 September 2010 **Note that these tax credits are subject to specific requirements set forth in the American Recovery and Reinvestment Act of 2009 and in the Internal Revenue Code. Goodman recommends that consumers consult[...]
-
Page 2
PRODUCT IDENTIFICA TION 2 The model and manufacturing number are used for positive identification of component parts used in manufacturing. Please use these numbers when requesting service or parts information. WARNING WARNING HIGH VOLTAGE! Disconnect ALL power before servicing or installing this unit. Multiple power sources may be present. Failure[...]
-
Page 3
PRODUCT IDENTIFICA TION 3 The model and manufacturing number are used for positive identification of component parts used in manufacturing. Please use these numbers when requesting service or parts information. GPC1424H41AA GPC1430H41AA GPC1436H41AA GPC1442H41AA GPC1448H41AA GPC1460H41AA The United States Environmental Protection Agency (“EPA”)[...]
-
Page 4
4 PRODUCT DESIGN GPC Package Cooling Units are designed for outdoor instal- lations only in either residential or light commercial applica- tions. The connecting ductwork (Supply and Return) can be con- nected for either horizontal or vertical airflow. In the vertical application a matching Roof Curb is recommended. A return air filter must be inst[...]
-
Page 5
PRODUCT DESIGN 5 36" 36" 24" P L E N U M U N I T P L A T F O R M C U R B Rooftop Installation - Horizontal (H) In installations where the unit is installed above ground level and not serviceable from the ground (Example: Roof Top in- stallations), the installer must provide service platform for ser- vice person with rails or guards i[...]
-
Page 6
6 PRODUCT DIMENSIONS GPC14[24-60]H41A* Ch ass i s M o d el A B GPC 142 4 33 3 0½ GPC 143 0 33 3 0½ GPC 143 6 33 3 5½ GPC 144 2 33 3 5½ GPC 144 8 33 3 8½ GPC 146 0 33 3 8½ Dime n s ion s in i n c he s La rge Sm a l l Me d i u m 34.075 66.5 42 4. 51 2 14 . 0 00 14 . 0 00 SUP PLY 6.50 0 RE TU RN 4.500 BACK VI EW (DUC T OPEN I NGS) A 14 . 0 00 B[...]
-
Page 7
PRODUCT DESIGN 7 HKR ELECTRICAL DA T A All wires and overcurrent protection devices are sized for use with electric heaters only and without refrigeration. If heaters are not installed with above wire size, overheating and fire could occur. See PACKAGE COOLING SPECIFICATIONS section for minimum circuit ampacity and maximum overcurrent protection du[...]
-
Page 8
ACCESSORIES 8 GPC14[24-60]H41A* P ar t N u mb er D esc ri p t i o n O T 18- 60 A O utdoor T her mos ta t Ki t w /Loc ko ut S tat O T /E HR 18 - 60 E me r gen c y Heat Relay Ki t HK R E l ec tr i c Heat K i t P CCP1 01 -103 Roof Cur b P C P101 - 103 Downflow P l enum K i t P C P101 - 103R8 Downfl ow P l enum K i t w / R - 8 Ins ul ation G PCE D1 01-[...]
-
Page 9
BLOWER PERFORMANCE DA T A 9 Dry Coil Data GPC14[24-60]H41A* 0. 1 0 .2 0 .3 0 .4 0 .5 0 .6 0 . 7 0 . 8 C F M 9 34 75 9 75 5 63 8 58 1 4 8 9 - - W A T T S 9 57 77 67 38 39 0 - - C F M 9 90 83 7 80 1 74 4 69 6 6 5 2 6 0 1 - W ATT S 1 07 9 4 10 5 11 0 1 1 9 1 3 3 14 2 - C F M 106 1 9 89 9 47 9 25 8 76 - - - W ATT S 1 26 1 3 4 14 6 15 8 16 9 - - - C F M[...]
-
Page 10
10 BLOWER PERFORMANCE DA T A 30 40 50 60 70 80 90 11 0 1 2 0 100 13 0 14 0 15 0 100 90 80 70 60 50 40 30 20 10 OUT P UT B TU/ H R x 10 00 BT U OUTPUT vs TEMPER AT URE RISE CHART TEMPERAT URE RISE 600 C FM 700 900 1000 1100 1200 140 0 160 0 1800 2000 220 0 240 0 C F M FORMULA S BTU OUTPUT = CFM x 1.08 x RISE RISE = BTU OUTPUT 1.0 8 ÷ CF M 800[...]
-
Page 11
P ACKAGE COOLING SPECIFICA TIONS 11 GPC14[24-30]H41AA IMPORTANT: While this data is presented as a guide, it is important to electrically connect the unit and properly size wires and fuses/circuit breakers in accordance with the National Electrical Code and/or all local codes. Data shown is w/o electric heaters. (1) Maximum Overcurrent Protection D[...]
-
Page 12
P ACKAGE COOLING SPECIFICA TIONS 12 GPC14[36-42]H41AA IMPORTANT: While this data is presented as a guide, it is important to electrically connect the unit and properly size wires and fuses/circuit breakers in accordance with the National Electrical Code and/or all local codes. Data shown is w/o electric heaters. (1) Maximum Overcurrent Protection D[...]
-
Page 13
P ACKAGE COOLING SPECIFICA TIONS 13 IMPORTANT: While this data is presented as a guide, it is important to electrically connect the unit and properly size wires and fuses/circuit breakers in accordance with the National Electrical Code and/or all local codes. Data shown is w/o electric heaters. (1) Maximum Overcurrent Protection Device: MUST use Ti[...]
-
Page 14
14 COOLING PERFORMANCE DA T A GPC1424H41AA MOD E L : G P C 1424H41A * EX PAN DE D P ER FO R MANC E D ATA C OOL I NG OP E R AT I ON De s ign Sub c ooli ng , 9 ± 2°F @ the l i qui d a c c e s s fitting c onn e ct i on A HRI 9 5 te s t c ondi t io ns . Desi gn S upe r he at 5 ± 2 °F @ the c om pr es sor s uct i o n a cce ss fi tti n g co n nect io[...]
-
Page 15
15 COOLING PERFORMANCE DA T A GPC1424H41AA MOD E L : G PC 1424H41A * EX PA N DE D P ER F O R M AN C E D AT A C OOL I NG OP ER AT I ON De s i gn Sub cooli ng , 9 ± 2°F @ the l i qui d acce s s f i tting c onn e ct i on A HRI 9 5 te s t c ondi t i ons . De s i gn S upe r he at 5 ± 2 °F @ the c om pr es sor s u cti on a cce ss fi t ti ng co n nect[...]
-
Page 16
16 COOLING PERFORMANCE DA T A GPC1430H41AA MOD E L : G P C 1430H41A * EX PAN DE D P ER F O R M AN C E D ATA C OOLI NG OP ER ATI ON De s i gn S ubc ooli ng , 1 0 ± 2 °F @ the l i qui d a c ce s s f i tting c onnec tion A RI 9 5 test c ondi tio ns . De s i g n S up e rh e at 1 0 ± 2 °F @ the c o m p r es sor sucti o n acc ess f itt i n g co n n e[...]
-
Page 17
17 COOLING PERFORMANCE DA T A GPC1430H41AA MOD E L : G PC 1430H41A * EX PA N DE D P ER F O R M AN C E D AT A C OOL I NG OP ER AT I ON De s ign S ubc ool i ng , 1 0 ± 2 °F @ the l i qui d a c ce s s f i tting c onne ct i on A R I 9 5 t e st conditio ns . De s i g n Sup e rh e at 1 0 ± 2 °F @ the c o m p r es so r suct i o n acc ess f itt i n g c[...]
-
Page 18
18 COOLING PERFORMANCE DA T A GPC1436H41AA MOD E L : G P C 1436H41A * EX PAN DE D P ER F O R M AN C E D ATA C OOLI NG OP ER ATI ON De s i gn Sub cooli ng , 10 ± 2 °F @ t he l iqui d a cc e ss fitting con ne c t i on A RI 95 te st c onditi ons. De s i gn S uperhe at 9 ± 2 °F @ t he c omp r e ssor su cti o n acc ess f it ti n g co n n e cti o n .[...]
-
Page 19
19 COOLING PERFORMANCE DA T A GPC1436H41AA MOD E L : G PC 1436H41A * EX PA N DE D P ER F O R M AN C E D AT A C OOL I NG OP ER AT I ON De s i gn Sub cooli ng , 10 ± 2 °F @ t he l iqui d a cc e ss fitting con ne c t i on A RI 95 te st cond i tions. De sign S uperhe at 9 ± 2 °F @ t he c omp r e ssor su cti o n acc ess f it ti n g co n n e cti o n [...]
-
Page 20
20 COOLING PERFORMANCE DA T A GPC1442H41AA MOD E L : G P C 1442H 41A * EX PAN DE D P ER FO R M ANC E D AT A C OOLI NG OP E R ATION Desi g n Su b co o l i n g , 8 ± 2 ° F @ th e l i q u i d acc ess f it ti ng co n n e cti o n A H R I 9 5 test c o n d i t i o n s. D esi g n Su p er h ea t 8 ± 2 ° F @ t h e co m p re sso r su ct io n ac ces s fi t[...]
-
Page 21
21 COOLING PERFORMANCE DA T A GPC1442H41AA MOD E L : G PC 1442H41A * EX PA N DE D P ER F O R M AN C E D AT A C OOL I NG OP ER AT I ON Desi g n Su b co o l i n g, 8 ± 2 ° F @ th e l iqu i d acc ess f it ti n g co n n e ct i o n A HR I 9 5 t est c o n d i t i o n s. D esi g n Su p er h ea t 8 ± 2 ° F @ t h e co m pr e s s or suc t i on acce s s f[...]
-
Page 22
22 COOLING PERFORMANCE DA T A GPC1448H41AA MOD E L : G P C 1448H41A * EX PAN DE D P ER F O R M AN C E D ATA C OOLI NG OP ER ATI ON De s i gn Sub cooli ng , 10 ± 2 °F @ the l i qui d a c ce s s f i tting c onne c tion A HRI 95 te s t c ondi ti ons . Desi gn S u pe r he at 1 0 ± 2 °F @ t he c ompr e ss or suc tion ac c es s fi t ti n g c onne c t[...]
-
Page 23
23 COOLING PERFORMANCE DA T A GPC1448H41AA MOD E L : G PC 1448H41A * EX PA N DE D P ER F O R M AN C E D AT A C OOL I NG OP ER AT I ON De s i gn Sub cooli ng , 10 ± 2 °F @ the l i qui d acce s s f i tting c onnec tion A HRI 95 te s t c ondi ti ons . Desi gn S u pe r he a t 10 ± 2 ° F @ t he c o mpr e ss or suc tion a c c e s s fi t tin g c onne [...]
-
Page 24
24 COOLING PERFORMANCE DA T A GPC1460H41AA MOD E L : G P C 1460H41A * EX PAN DE D P ER F O R M AN C E D ATA C OOLI NG OP ER ATI ON Desi g n Su b co o l i n g, 6 ± 2 ° F @ th e l iqu i d acc ess f it ti n g co n n e cti o n A H R I 9 5 t est c on d i t i o n s. D esi g n Su p er h ea t 9 ± 2° F @ th e co m p re s s or s uct io n a cc e s s fit t[...]
-
Page 25
25 COOLING PERFORMANCE DA T A GPC1460H41AA MOD E L : G PC 1460H41A * EX PA N DE D P ER F O R M AN C E D AT A C OOL I NG OP ER AT I ON De s i gn Sub cooli ng , 6 ± 2 °F @ the l i quid ac c es s fi t t i n g co nne c tion AH RI 9 5 t e s t c ond iti ons. De sign S upe r hea t 9 ± 2 °F @ the c ompre s s or sucti o n a c ce s s f itting c onne c ti[...]
-
Page 26
26 COOLING PERFORMANCE DA T A PERFORMANCE TEST All data based upon listed indoor dry bulb temperature. .00 inches external static pressure on coil of outdoor section. Indoo r air cubic feet per minute (CFM) as listed in the Performance Data Sheets: If conditions vary from this, results will change as follows: 1. As indoor dry bulb temperatures incr[...]
-
Page 27
WIRING DIAGRAMS 27 WARN I NG HIGH VOLTAGE! DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS UNIT . MULTI PLE POWE R S OUR CES MAY B E PRESENT . F AILURE TO DO SO MAY CAUSE PROPERTY DAM AGE, PERSONAL INJURY OR DEATH. Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring. GPC14[24-60]H41AA [...]
-
Page 28
28 GPC 14 SEER R-410A 5mm Package Air Conditioners GPC Package Cooling Units are designed for outdoor instal- lations only in either residential or light commercial applica- tions. The connecting ductwork (Supply and Return) can be con- nected for either horizontal or vertical airflow. In the vertical application a matching Roof Curb is recommended[...]
-
Page 29
PRODUCT DESIGN 29 Location and Clearances NOTE: To ensure proper condensate drainage, unit must be installed in a level position. 36" 36" 10" UNIT WALL 36" Outside Slab Installation - Horizontal (H) Minimum clearances are required to avoid air recirculation and keep the unit operating at peak efficiency. 36" 36" 24&quo[...]
-
Page 30
P ACKAGE COOLING SPECIFICA TIONS 30 IMPORTANT: While this data is presented as a guide, it is important to electrically connect the unit and properly size wires and fuses/circuit breakers in accordance with the National Electrical Code and/or all local codes. Data shown is w/o electric heaters. (1) Maximum Overcurrent Protection Device: MUST use Ti[...]
-
Page 31
P ACKAGE COOLING SPECIFICA TIONS 31 IMPORTANT: While this data is presented as a guide, it is important to electrically connect the unit and properly size wires and fuses/circuit breakers in accordance with the National Electrical Code and/or all local codes. Data shown is w/o electric heaters. (1) Maximum Overcurrent Protection Device: MUST use Ti[...]
-
Page 32
32 COOLING PERFORMANCE DA T A GPC1424H41AB 5MM COILS MOD E L : G P C 1424H41A * EX PAN DE D P ER F O R M AN C E D ATA C OOLI NG OP ER ATI ON O ut d o o r A m b i en t T em p er atu r e 65 75 8 5 95 10 5 115 E n t eri n g In d o o r W e t B u lb T em p e r at u r e I D B * A i r f l o w 5 96 36 77 15 9 6 36 77 15 96 36 7 7 15 9 6 3 6 7 7 1 5 96 36 7[...]
-
Page 33
33 COOLING PERFORMANCE DA T A GPC1424H41AB 5MM COILS MOD E L : G P C 1424H41A * EX PAN DE D P ER F O R M AN C E D ATA C OOL ING OP E R AT ION O ut d o o r A m b i en t T em p er atu r e 65 75 8 5 95 10 5 115 E n t e ri n g In d o or W e t B u lb T em p e r at u r e I D B * A i r f l o w 5 96 36 77 15 9 6 36 77 15 96 36 7 7 15 9 6 3 6 7 7 1 5 96 36 [...]
-
Page 34
34 COOLING PERFORMANCE DA T A GPC1430H41AB 5MM COILS MOD E L : G P C 1430H41A * EX PAN DE D P ER F O R MANC E D ATA C OOLING OP ER ATION Ou t doo r A m bi en t Te mpera ture 65 75 8 5 95 10 5 115 E nte r i ng I nd oor We t Bulb T e m pe r a ture I D B * A i r f l o w 5 96 36 77 15 9 6 36 77 15 96 36 7 7 15 9 6 3 6 7 7 1 5 96 36 77 15 9 6 36 77 1 MB[...]
-
Page 35
35 COOLING PERFORMANCE DA T A GPC1430H41AB 5MM COILS MOD E L : G P C 1430H41A * EX PAN DE D P ER F O R M AN C E D ATA C OOL ING OP E R AT ION O ut d o o r A m b i en t T em p er atu r e 65 75 8 5 95 10 5 115 E n t e ri n g In d o or W e t B u lb T em p e r at u r e I D B * A i r f l o w 5 96 36 77 15 9 6 36 77 15 96 36 7 7 15 9 6 3 6 7 7 1 5 96 36 [...]
-
Page 36
36 COOLING PERFORMANCE DA T A GPC1436H41AB 5MM COILS MOD E L : G P C 1436H 41A * EX PAN DE D P ER FO R M ANC E D AT A C OOLI NG OP E R ATION O u t doo r A m bi ent Te mpera ture 65 75 8 5 95 10 5 115 E nte r ing I nd oor We t Bulb T e m pe r a ture I D B * A i r f l o w 5 96 36 77 15 9 6 36 77 15 96 36 7 7 15 9 6 3 6 7 7 1 5 96 36 77 15 9 6 36 77 1[...]
-
Page 37
37 COOLING PERFORMANCE DA T A GPC1436H41AB 5MM COILS MOD E L : G PC1436H41A * EX PA NDE D P ER FO R M AN C E D ATA C OOL ING OPER ATION O ut d o or A m b i en t T em p er atu r e 65 75 8 5 95 10 5 115 E nt eri ng In d oo r W et B ulb T em p er atu re I D B * A i r f l o w 5 96 36 77 15 9 6 36 77 15 96 36 7 7 15 9 6 3 6 7 7 1 5 96 36 77 15 9 6 36 7 [...]
-
Page 38
38 COOLING PERFORMANCE DA T A GPC1442H41AB 5MM COILS MOD E L : G P C 1442H41A * EX PAN DE D P ER F O R M AN C E D ATA C OOLI NG OP ER ATI ON O ut d o o r A m b i en t T em p er atu r e 65 75 8 5 95 10 5 115 E n t eri n g In d o o r W e t B u lb T em p e r at u r e I D B * A i r f l o w 5 96 36 77 15 9 6 36 77 15 96 36 7 7 15 9 6 3 6 7 7 1 5 96 36 7[...]
-
Page 39
39 COOLING PERFORMANCE DA T A GPC1442H41AB 5MM COILS MOD E L : G P C 1442H41A * EX PAN DE D P ER F O R M ANC E D ATA C OOLIN G OPE R A TION Ou t doo r A mbi e nt Te m pera ture 65 75 8 5 95 10 5 115 E nte r i ng I nd oor Wet Bulb T e m pe r a ture I D B * A i r f l o w 5 96 36 77 15 9 6 36 77 15 96 36 7 7 15 9 6 3 6 7 7 1 5 96 36 77 15 9 6 36 77 1 [...]
-
Page 40
40 COOLING PERFORMANCE DA T A GPC1448H41AB 5MM COILS MOD E L : G P C 1448H41A B EX PA N DE D P ER FO R MANC E D ATA C OOLI NG OP ER ATI ON O ut d o o r A m b i en t T em p er atu r e 65 75 8 5 95 10 5 115 E n t eri n g In d o o r W e t B u lb T em p e r at u r e I D B * A i r f l o w 5 96 36 77 15 9 6 36 77 15 96 36 7 7 15 9 6 3 6 7 7 1 5 96 36 77 [...]
-
Page 41
41 COOLING PERFORMANCE DA T A GPC1448H41AB 5MM COILS MOD E L : G P C 1448H41A B EX PA N DE D P ER F O R M AN C E D ATA C OOL ING OP ER ATI ON O ut d o o r A m b i en t T em p er atu r e 65 75 8 5 95 10 5 115 E n t e ri n g In d o o r W et B u lb T em p er at u re I D B * A i r f l o w 5 96 36 77 15 9 6 36 77 15 96 36 7 7 15 9 6 3 6 7 7 1 5 96 36 77[...]
-
Page 42
42 COOLING PERFORMANCE DA T A PERFORMANCE TEST All data based upon listed indoor dry bulb temperature. .00 inches external static pressure on coil of outdoor section. Indoo r air cubic feet per minute (CFM) as listed in the Performance Data Sheets: If conditions vary from this, results will change as follows: 1. As indoor dry bulb temperatures incr[...]
-
Page 43
WIRING DIAGRAMS 43 WARN I NG HIGH VOLTAGE! DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS UNIT . MULTI PLE POWE R S OUR CES MAY B E PRESENT . F AILURE TO DO SO MAY CAUSE PROPERTY DAM AGE, PERSONAL INJURY OR DEATH. Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring. GPC14[24-48]H41AB [...]