Go to page of
Similar user manuals
-
Paint Sprayer
Graco Inc. ti13107a
8 pages 0.57 mb -
Paint Sprayer
Graco Inc. 308870
26 pages 0.99 mb -
Paint Sprayer
Graco Inc. 255113
56 pages 3.11 mb -
Paint Sprayer
Graco Inc. ti5641a
30 pages 2.08 mb -
Paint Sprayer
Graco Inc. 233670
32 pages 0.47 mb -
Paint Sprayer
Graco Inc. 289251
36 pages 1.44 mb -
Paint Sprayer
Graco Inc. 24F060
36 pages 1.44 mb -
Paint Sprayer
Graco Inc. 289308
36 pages 1.44 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Graco Inc. 306706, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Graco Inc. 306706 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Graco Inc. 306706. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Graco Inc. 306706 should contain:
- informations concerning technical data of Graco Inc. 306706
- name of the manufacturer and a year of construction of the Graco Inc. 306706 item
- rules of operation, control and maintenance of the Graco Inc. 306706 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Graco Inc. 306706 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Graco Inc. 306706, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Graco Inc. service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Graco Inc. 306706.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Graco Inc. 306706 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
Instructions–Parts List 306706W ST A TIONAR Y AIRLESS P AINT SPRA YER 30:1 President R Hydra–Spray R Used for airless spray application of paints and other coatings from a 50–gallon drum. 3000 psi (21.0 MPa, 210 bar) Maximum Working Pressure 100 psi (0.7 MPa, 7 bar) Maximum Air Input Pressure Important Safety Instructions Read all warnings an[...]
-
Page 2
2 306706 T able of Contents W arnings 3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Installation Grounding 6 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Positioning the Unit 6 . . . . . . . . . . . . . . . . . . . . . . . . . . System Accessories 6 . . . . . . . . . . . . . . . . . . . . . . .[...]
-
Page 3
306706 3 W ARNING INSTRUCTIONS EQUIPMENT MISUSE HAZARD Equipment misuse can cause the equipment to rupture or malfunction and result in serious injury . D This equipment is for professional use only . D Read all instruction manuals, tags, and labels before operating the equipment. D Use the equipment only for its intended purpose. If you are not su[...]
-
Page 4
4 306706 W ARNING SKIN INJECTION HAZARD Spray from the gun, leaks, or ruptured components can inject fluid into your body and cause extremely serious injury , including the need for amputation. Fluid splashed in the eyes or on the skin can also cause serious injury . D Fluid injected into the skin might look like just a cut, but it is a serious inj[...]
-
Page 5
306706 5 W ARNING FIRE AND EXPLOSION HAZARD Improper grounding, poor ventilation, open flames or sparks can cause a hazardous condition and result in a fire or explosion and serious injury . D Ground the equipment and the object being sprayed. Refer to Grounding on page 6. D If there is any static sparking or you feel an electric shock while using [...]
-
Page 6
6 306706 Installation NOTES: D Reference numbers and letters in parentheses in the text refer to the callouts in the figures and the parts drawing. D Accessories are available from your Graco repre- sentative. If you supply your own accessories, be sure they are adequately sized and pressure-rated to meet the system’s requirements. Grounding Prop[...]
-
Page 7
306706 7 Installation The installation shown in Fig. 2 is only a guide for selecting and installing system components and accessories. Contact your Graco distributor for assistance in designing a system to suit your particular needs. Connecting the Unit and Accessories D Ground the unit as described in Grounding on page 6. D Connect a 1/2 in. (13 m[...]
-
Page 8
8 306706 Operation/Maintenance Pressure Relief Procedure SKIN INJECTION HAZARD The system pressure must be manually relieved to prevent the system from starting or spraying accidentally . Fluid under high pressure can be injected through the skin and cause serious injury . T o reduce the risk of an injury from injection, splashing fluid, or moving [...]
-
Page 9
306706 9 Operation/Maintenance 3. Push in on the air valve knob to lower the elevator , so the cover (A) rests on the top lip of the drum. The support clamp (K) recesses must be tight against the elevator riser tube. The pump intake valve feet (B) must contact and support the perfo- rated plate (9) as shown in Fig. 2. 4. Raise the elevator 1/4” ([...]
-
Page 10
10 306706 Parts Drawing Model 231063, Series C, 30:1 President R Hydra-Spray R A A A 06218A 31 19 06218 1 2 3 4 5 6a 6b 6c 6d 6e 7 8 9 10 11 12 43, 44 15 46 20 45 21 23 24 25 26 28 29 30 48 31 32 34 35 36 37 38 39 40 42 43 44 45 46 47 49 51 23 70 52 71 69 74 75 76 98 104[...]
-
Page 11
306706 1 1 Parts List Model 231063, Series C, 30:1 President R Hydra-Spray R Ref. No. Part No. Description Qty . 1 202295 V AL VE, push-pull See 306287 for parts. 1 2 203743 V AL VE, restrictor See 306287 for parts. 1 3 204385 ELEV A TOR See 306287 for parts. 1 4 204940 SWIVEL See 306861 for parts. 1 5 204995 AGIT A TOR See 306459 for parts. 1 6 20[...]
-
Page 12
12 306706 Notes[...]
-
Page 13
306706 13 T echnical Data Ratio 30:1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Maximum fluid working pressure 3000 psi (21 MPa, 207 bar) . . . . . . . . . . . . . . . . . . . Maximum air input pressure 100 psi (0.7 MPa, 7 bar) . . . . . . . . . . . . . . . . . . . .[...]
-
Page 14
14 306706 Graco Standard W arranty Graco w arrants all equipment manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty published by Graco, Graco w ill, for a period of twelve months from th[...]