Graco 15V534 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Graco 15V534, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Graco 15V534 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Graco 15V534. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Graco 15V534 should contain:
- informations concerning technical data of Graco 15V534
- name of the manufacturer and a year of construction of the Graco 15V534 item
- rules of operation, control and maintenance of the Graco 15V534 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Graco 15V534 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Graco 15V534, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Graco service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Graco 15V534.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Graco 15V534 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    313212A ENG Instr uctions-P ar ts 15V534 Gun Flush Bo x Interface Kit Interfaces a Graco Gun Flush Bo x with a ProMix ® 2KS Electr onic Pr opor tioner using a RoboMix Fluid Station. For prof essional use only . Appro ved f or use in explosive atmospheres onl y when used in conju nction with ProMix 2KS Electronic Pr oportioners. 100 psi (0.7 M P a,[...]

  • Page 2

    Related Manua ls 2 313212A Contents Related M anuals . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Mount the [...]

  • Page 3

    Installation 313212A 3 Installation Location Install the gun flush box mod ule enclosure (1) within 15 ft (4.5 m) of the RoboM ix, to ensur e that the c able (23) will reach the RoboMix. The mo dule is approv ed f or use in a hazardous loca tion. See F IG . 1. Mount the Enc losure 1. See Dimensions , pag e 13. 2. Ensure that the w all and mounting [...]

  • Page 4

    Installation 4 313212A Install the Cable 1. Loosen the capt ive scre ws and remo ve the front cov er from the en closure. 2. The ca ble (23) has bare wires at both end s. Thread the shor test end ( 4 in. [102 mm ]) into the en closure through the str ain relief bushing (7) . See F IG . 2. 3. Connect the ca ble wires to the left side of the termi- n[...]

  • Page 5

    Installation 313212A 5 Install the Air Flow Switc h NO TE: The GFB Interf ace Module Kit does not include an air flow s witch (AFS). The AFS is supplied with the gun flush bo x kit. Install th e AFS in the interf ace module as follo ws. 1. Each gun flush bo x kit includes one air flo w s witch (AFS). The G FB interf ace module can accommo- date 1 o[...]

  • Page 6

    Installation 6 313212A Install the Pressure Switch NO TE: The GFB Interf ace Mo dule Kit does not include a pressure s witch (PS). The pressu re swit ch is supplied with the gun flush bo x kit. In stall the pressure s witch in the interf ace module as f ollows. 1. Each gun flush bo x kit includes one pressure switch (PS). The GFB interf ace module [...]

  • Page 7

    Installation 313212A 7 Install the Solenoid NO TE: The GFB Interf ace Mo dule Kit does not include a solenoid (SO). The solenoid is supplied with the gun flush bo x kit. Install the solenoid in the interf ace module as follo ws. 1. Each gun flush bo x kit includes one so lenoid (SO). The GFB interf ace modu le can accommodate 1 or 2 solenoids. Inst[...]

  • Page 8

    Installation 8 313212A Connect the Cable to the RoboMix Contr ol Boar d 1. See the ProMix 2KS Repair-P ar ts manual. Open the RoboMix to access the cont rol board. 2. Conne ct the 10 position conn ector (24) to J1 on th e control board. See F IG . 9. 3. Connect the 6 posit ion connector (25) to J8 on t he control board. See F IG . 10 NO TICE T o a [...]

  • Page 9

    Installation 313212A 9 Connect the Gun Flush Bo x NO TE: Use 5/32 in. (4 mm) OD tubi ng to connect the gun flush bo x air ports to the interf ace module air ports, as f ollows. See F IG . 12. 1. F rom the P por t to the air sup ply . 2. F rom the A por t to the pressu re s witch a ir input. 3. F rom the C por t to the gun flush bo x solenoid out - [...]

  • Page 10

    Installation 10 313212A[...]

  • Page 11

    Parts 313212A 11 Pa r t s 1 2 3 4 5 6 7 8 9 10 11 12 AIR FL OW SWITCH #1 + (BLK) AIR FL OW SWITCH #1 - ( WHT ) AIR FL OW SWITCH #2 + (RED) AIR FL OW SWITCH #2 - (GRN) PRESSURE SWITCH #1 + ( ORG) PRESSURE SWITCH #1 - (BL U) PRESSURE SWITCH #2 + (WHT/BLK ) PRESSURE SWITCH #2 - (RED/BLK) SOLENOID #1 +12 (GRN/BLK) SOLENOID #1 COM (ORG/BLK) SOLENOID #2 [...]

  • Page 12

    Connect a Booth Control to the RoboM ix (to operate as a manual system) 12 313212A Connect a Booth Contr ol to the RoboMix (to operate as a manual system) T o use the RoboMix as a ma nual system, order t he 15V350 Booth Control Kit and connect as f ollo ws. The kit includes a booth control module , wall br ack et, and 50 ft (15.25 m ) cable. 1. See[...]

  • Page 13

    Dimensions 313212A 13 Dimensions Te c h n i c a l D a t a TI14276a TI14278a 6.75 in. (171.5 mm) 7.50 in. (190.5 mm) 6.28 in. (159.5 mm) 4.00 in. (101.6 mm) 4.00 in. (101.6 mm) Mounting Holes Maximum Air Inpu t Pressure . . . . . . . . . . . . . . . . . . . . . 100 psi (0.7 MP a, 7 bar) Air Inlet S ize . . . . . . . . . . . . . . . . . . . . . . . .[...]

  • Page 14

    All written and visual data con tained in th is document reflects the late st product information available at the time of pu blica tion. Graco reserves the right to make changes at any time without notice. This manual contains English. MM 313212 Graco Headquarters: Minneapoli s Internationa l Offices: Belgium, China, Japan, Ko rea GRACO INC. P.O. [...]