Graco 230993 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Graco 230993, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Graco 230993 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Graco 230993. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Graco 230993 should contain:
- informations concerning technical data of Graco 230993
- name of the manufacturer and a year of construction of the Graco 230993 item
- rules of operation, control and maintenance of the Graco 230993 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Graco 230993 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Graco 230993, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Graco service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Graco 230993.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Graco 230993 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Instructions – Parts List GRACO INC.ąP .O. BOX 1441ąMINNEAPOLIS, MNą55440-1441 Copyright 1985, Graco Inc. is registered to I.S. EN ISO 9001 55 GALLON SUPPL Y PUMPS 3:1 President r , 4:1 President r , and 2:1 Monark r With drum cover and agitator Model 220575, Series B with 3:1 Ratio President Pump 500 psi (3.5 MPa, 35 bar) MAXIMUM FLUID WORKIN[...]

  • Page 2

    2 307745 T able of Contents W arnings 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Setup Grounding 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Positioning the Unit 5 . . . . . . . . . . . . . . . . . . . . . . . . . . System Accessories 5 . . . . . . . . . . . . . . . . . . . . . . . . . Co[...]

  • Page 3

    307745 3 W ARNING MOVING P ARTS HAZARD D The air motor piston can pinch or amputate your fingers. D The rotating blades of the agitator can pinch or amputate your fingers or other body parts and can cause splashing in the eyes or on the skin. D Always shut off the agitator and disconnect the air line before adjusting the angle of the agitator , rem[...]

  • Page 4

    4 307745 W ARNING FIRE AND EXPLOSION HAZARD Improper grounding, poor ventilation, open flames or sparks can cause a hazardous condition and result in a fire or explosion and serious injury . D Ground the equipment and the object being sprayed. Refer to Grounding on page 5. D If there is any static sparking or you feel an electric shock while using [...]

  • Page 5

    307745 5 Setup NOTES: D Reference numbers and letters in parentheses in the text refer to the callouts in the figures and the parts drawing. D Accessories are available from your Graco repre- sentative. If you supply your own accessories, be sure they are adequately sized and pressure-rated to meet the system’s requirements. Grounding FIRE AND EX[...]

  • Page 6

    6 307745 Setup The installation shown in Fig. 2 is only a guide for selecting and installing system components and accessories. Contact your Graco representative for assistance in designing a system to suit your particular needs. Connecting the Unit and Accessories D Ground the unit as described in Grounding on page 5. D The main air supply must in[...]

  • Page 7

    307745 7 Operation Pressure Relief Procedure W ARNING PRESSURIZED EQUIPMENT HAZARD The system pressure must be manually relieved to prevent the system from starting or spraying acci- dentally . T o reduce the risk of an injury from acci- dental spray from the gun, splashing fluid, or moving parts, follow the Pressure Relief Proce- dure whenever you[...]

  • Page 8

    8 307745 Operation 8. Shut off the air to the pump, open the bleed–type master air valve, and open the drain valve (K). Leave the solvent in the system overnight or , if possible, all weekend. 9. Start the pump and circulate it again for 30 min- utes. Raise the pump out of the solvent and let it dry to force out the solvent. Drain solvent from al[...]

  • Page 9

    307745 9 Operation Shutdown and Care of the Pump W ARNING T o reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 7. Never allow paint to dry in the pump and lines. T o shutdown the system 1. Relieve the pressure. Stop the agitator , and lubricate it. 2. If using a G[...]

  • Page 10

    10 307745 Parts Drawing c Fig. 3 1 or 5 2 3 6 (MONARK PUMP SHOWN) 10 9 8 11 Model 230993, Series B 2:1 Ratio Monark Carbon Steel 55 Gallon Drum System Includes items 2 to 6, and 1 1 Model 230992, Series B 4:1 Ratio President Carbon Steel 55 Gallon Drum System Includes items 1 to 4, and 6 to 12 7 12[...]

  • Page 11

    307745 1 1 Parts List Model 230992, Series B 4:1 Ratio President Carbon Steel 55 Gallon Drum System Includes items 1 to 4, and 6 to 12 Model 230993, Series B 2:1 Ratio Monark Carbon Steel 55 Gallon Drum System Includes items 2 to 6, and 1 1 Ref. No. Part No. Description Qty . 1 223183 4:1 RA TIO PRESIDENT PUMP; See 307986 for parts. 1 2 237307 COVE[...]

  • Page 12

    12 307745 Parts Drawing 7679A Model 220575, Series B 3:1 Ratio President Stainless Steel 55 Gallon Drum System Includes items 1–35 Ref No. 6 includes items 6a–6d. Ref No. 5 includes items 5a–5c. 1 2 5a 35 3 6a 6b,6c 6d 4 1 2 Remove and discard 1/2 x 3/8 npt nipple from outlet of air regulator (5a), and replace with 1/2 npt nipple (5c). Then c[...]

  • Page 13

    307745 13 Parts List Model 220575, Series B 3:1 Ratio President Stainless Steel 55 Gallon Drum System Ref Part No. No. Description Qty 1 220564 PUMP , President See 308793 for parts 1 2 237309 COVER, drum, 55 gal. (200 liter) See 308466 for parts 1 3 222698 AGIT A TOR See 306840 for parts 1 4 220580 RISER TUBE KIT See 307837 for parts 1 5 223180 AI[...]

  • Page 14

    14 307745 Notes[...]

  • Page 15

    307745 15 T echnical Data Category Model 220575 Model 230992 Model 230993 Ratio 3:1 4:1 2:1 Maximum fluid working pressure 500 psi (3.5 MPa, 35 bar) 400 psi (2.8 MPa, 28 bar) 200 psi (1.4 MPa, 14 bar) Maximum air input pressure 166 psi (1.2 MPa, 1 1.6 bar) 100 psi (0.7 MPa, 7 bar) 100 psi (0.7 MPa, 7 bar) Pump cycles per 1 gallon (3.8 liters) 6.3 8[...]

  • Page 16

    16 307745 Graco Standard W arranty Graco warrants all equipment manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twelve months from the [...]