Go to page of
Similar user manuals
-
Heat Pump
Graco 260580
16 pages 1 mb -
Heat Pump
Graco 308738C
16 pages 1.43 mb -
Heat Pump
Graco 24J398
18 pages 1.11 mb -
Heat Pump
Graco 24J399
18 pages 1.11 mb -
Heat Pump
Graco 24J397
18 pages 1.11 mb -
Heat Pump
Graco 246781
18 pages 1.17 mb -
Heat Pump
Graco 24K466
18 pages 1.11 mb -
Heat Pump
Graco 233500
26 pages 0.43 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Graco 256714, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Graco 256714 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Graco 256714. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Graco 256714 should contain:
- informations concerning technical data of Graco 256714
- name of the manufacturer and a year of construction of the Graco 256714 item
- rules of operation, control and maintenance of the Graco 256714 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Graco 256714 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Graco 256714, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Graco service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Graco 256714.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Graco 256714 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
Instructions–Parts List 3081 18N EN SEVERE-DUTY , UHMWPE/PTFE P ACKED Stainless Steel Pumps 55 gallon (200 liter) drum size, with bung adapter . For transfer and supply of solventborne and waterborne finishing materials. For professional use only . Important Safety Instructions Read all warnings and instructions in this manual. Save these instruc[...]
-
Page 2
2 308118 T able of Contents W arnings 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Installation 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Operation 9 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . T roubleshooting 13 . . . . . . . . . . . . . . . . . . . .[...]
-
Page 3
3 308118 W ARNING SKIN INJECTION HAZARD Spray from the gun/valve, hose leaks, or ruptured components can inject fluid into your body and cause extremely serious injury , including the need for amputation. Fluid splashed in the eyes or on the skin can also cause serious injury . Fluid injected into the skin might look like just a cut, but it is [...]
-
Page 4
4 308118 W ARNING FIRE AND EXPLOSION HAZARD Improper grounding, poor ventilation, open flames or sparks can cause a hazardous condition and result in a fire or explosion and serious injury . Ground the equipment and the object being sprayed. Refer to Grounding on page 5. If there is any static sparking or you feel an electric shock while us[...]
-
Page 5
5 308118 Installation Grounding W ARNING FIRE AND EXPLOSION HAZARD Before operating the pump, ground the system as explained below . Also read the section FIRE AND EXPLOSION HAZARD on page 4. T o reduce the risk of static sparking, ground the pump. Check your local electrical code for detailed grounding instructions for your area and type of equipm[...]
-
Page 6
6 308118 Installation KEY A Pump B Pump Runaway V alve C Air Line Lubricator D Bleed–T ype Master Air V alve (required, for pump) E Pump Air Regulator F Air Line Filter G Bleed–T ype Master Air V alve (for accessories) H Air Supply Hose J Fluid Drain V alve (required) K Fluid Filter L Fluid Supply Hose M Spray Gun N Pump Bung Adapter Y Ground W[...]
-
Page 7
7 308118 Installation NOTE: Reference numbers and letters in parentheses in the text refer to the callouts in the figures and the Parts Drawing. NOTE: Contact you Graco distributor for available Graco accessories. If you supply your own accesso- ries, be sure they are adequately sized and pressure- rated to meet the system’s requirements. The T y[...]
-
Page 8
8 308118 Notes[...]
-
Page 9
9 308118 Operation Pressure Relief Procedure W ARNING SKIN INJECTION HAZARD Fluid under high pressure can be in- jected through the skin and cause serious injury . T o reduce the risk of an injury from injection, splashing fluid, or moving parts, follow the Pressure Relief Procedure whenever you: are instructed to relieve the pressure, stop[...]
-
Page 10
10 308118 Operation Starting and Adjusting the Pump W ARNING T o reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 9. See the T ypical Installation on page 6. Be sure the air regulator (E) and bleed-type master air valve (D) are closed. Do not install the spray tip[...]
-
Page 11
11 308118 Operation Fig. 2 AIR MOTOR PLA TE 14 0200A[...]
-
Page 12
12 308118 Notes[...]
-
Page 13
13 308118 T roubleshooting W ARNING T o reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 9. Before servicing this equipment always make sure to relieve the pressure . Check all possible problems and solutions before disassembling the pump. Problem Cause Solution P[...]
-
Page 14
14 308118 Service Disconnecting the Displacement Pump W ARNING T o reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 9. 1. Flush the pump, if possible. Stop the pump at the bottom of its stroke. Relieve the pressure. 2. Disconnect the air and fluid hoses. Remove th[...]
-
Page 15
15 308118 Service Displacement Pump Service Disassembly When disassembling the pump, lay out all removed parts in sequence to ease reassembly . See Fig. 4. NOTES Standard Repair Kit 224403 (UHMWPE/PTFE packings) is available. For the best results, use all the new parts in the kit. Parts included in the kit are denoted with one asterisk, for exa[...]
-
Page 16
16 308118 Service Displacement Pump Service Reassembly 1. Lubricate the throat packings and install them in the outlet housing (5) one at a time as follows, with the lips of the v-packings facing down: the male gland (4*), one UHMWPE v-packing (3*), two PTFE v-packings (25*), one UHMWPE v-packing (3*), and the female gland (2*). Apply thread lubric[...]
-
Page 17
17 308118 Service 0193B Fig. 4 LIPS OF V–P ACKINGS MUST F ACE UP 13 27 *26 *28 *29 *30 *29 *31 14 SEE DET AIL A 14 2* 3* 25* 3* 4* LIPS OF V–P ACKINGS MUST F AC E DOWN 5 SEE DET AIL B 5 6 7 15 8 1 9 11 * 12* 17* *18 19 21 *16 27 13 10 20 1 2 Apply sealant and torque to 50–70 ft-lb (68–95 N m) 1 1 1 Apply thread lubricant 2 2 2 DET AIL B[...]
-
Page 18
18 308118 Parts Model 224348, Series C 10:1 Ratio President Pump Model 256713, Series A 10:1 Ratio President Pump (1.5 in. Female Inlet) Includes items 101–1 12 REF P ART NO. NO. DESCRIPTION QTY 101 224349 } DISPLACEMENT PUMP ASSY See pages 20 and 21 for parts 1 256712* DISPLACEMENT P UMP ASSY , 1.5 in. female inlet See pages 20 and 21 fo[...]
-
Page 19
19 308118 Parts Model 224350, Series C 5:1 Ratio Monark Pump Model 256714, Series A 5:1 Ratio Monark Pump (1.5 in. Female Inlet) Includes items 101–1 12 109† 106 101 11 2 102 REF P ART NO. NO. DESCRIPTION QTY 101 224349 } DISPLACEMENT PUMP ASSY See pages 20 and 21 for parts 1 256712 * DISPLACEMENT PUMP ASSY , 1.5 in. female inlet See pa[...]
-
Page 20
20 308118 Parts Model 224349, Series C Severe–Duty , Stainless Steel Displacement Pump Model 256712, Series A Severe–Duty , Stainless Steel Displacement Pump (1.5 in. Female Inlet) Includes items 1–34 1 *2 *3 *4 5 †6 7 8 9 10 11 * 12* 14 15 16* 17* 18* 19† 20 21 *25 26* 28* 29* 30* 31* *3 13 27 30* 33 34 0192B 35 36 37 38 39 256712 Base 2[...]
-
Page 21
21 308118 Parts Model 224349, Series C Severe–Duty , Stainless Steel Displacement Pump Includes items 1–35 Model 256712, Series A Severe–Duty , Stainless Steel Displacement Pump (1.5 in. Female Inlet) Includes items 1–16, 22–39 REF P ART NO. NO. DESCRIPTION QTY 1 24C506 ROD, displacement; stainless steel 1 2* 186988 GLAND, throat, female;[...]
-
Page 22
22 308118 T echnical Data (10:1 President) Category Data Maximum fluid working pressure 1800 psi (12.4 MPa, 124 bar) Maximum air input pressure 180 psi (1.25 MPa, 12.5 bar) Pump cycles per 1 gallon (3.8 liters) 20 Fluid flow at 60 cpm 3 gallon (1 1.4 liters) Recommended speed for optimum pump life 15–25 cycles/min; 0.75–1.25 gpm (2.84 to 4.73 l[...]
-
Page 23
23 308118 T echnical Data (10:1 President) Fluid Outlet Pressure Chart 0 200 400 600 800 1000 1200 1400 1600 1800 012345 PUMP DELIVER Y (T est Fluid: No. 10 Motor Oil) PUMP OUTLET PRESSURE 100 20 40 60 CPM 80 3.8 7.6 1 1.4 15.2 19.0 GPM l/min A B C 7.0, 70 4.2, 42 PSI 5.6, 56 2.8, 28 8.4, 84 1 1.0, 1 10 MPa, BAR 9.6, 96 12.5, 125 T o find Outlet Pr[...]
-
Page 24
24 308118 T echnical Data (5:1 Monark) Category Data Maximum fluid working pressure 900 psi (6.3 MPa, 63 bar) Maximum air input pressure 180 psi (1.25 MPa, 12.5 bar) Pump cycles per 1 gallon (3.8 liters) 24 Fluid flow at 60 cpm 2.5 gallon (9.46 liters) Recommended speed for optimum pump life 15–25 cycles/min; 0.63–1.04 gpm (2.38 to 3.94 liters/[...]
-
Page 25
25 308118 T echnical Data (5:1 Monark) Fluid Outlet Pressure Chart 0 200 400 600 800 012345 PUMP DELIVER Y (T est Fluid: No. 10 Motor Oil) PUMP OUTLET PRESSURE 120 24 48 72 CPM 96 3.8 7.6 1 1.4 15.2 19.0 GPM l/min A B C 4.2, 42 PSI 5.6, 56 2.8, 28 MPa, BAR T o find Outlet Pressure (MPa/bar/psi) at a specific delivery (liter/min or gpm) and operatin[...]
-
Page 26
26 308118 Pump Model A B C 224348 57.31 in. 14.63 in. 42.68 in. (1456 mm) (372 mm) (1084 mm) 256713 58.19 in. 14.63 in. 43.56 in. (1478 mm) (372 mm) (1 106 mm) 224350 54.28 in. 1 1.60 in. 42.68 in. (1379 mm) (295 mm) (1084 mm) 256714 55.16 in. 1 1.60 in. 43.56 in. (1401 mm) (295 mm) (1 106 mm) Model 224348 Shown A C Model 224348: 3/8 npsm(f); Model[...]
-
Page 27
27 308118 Notes[...]
-
Page 28
28 308118 Graco Standard W arranty Graco w arrants all equipment manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty published by Graco, Graco w ill, for a period of twelve months from th[...]