Graco 3A0410D manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Graco 3A0410D, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Graco 3A0410D one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Graco 3A0410D. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Graco 3A0410D should contain:
- informations concerning technical data of Graco 3A0410D
- name of the manufacturer and a year of construction of the Graco 3A0410D item
- rules of operation, control and maintenance of the Graco 3A0410D item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Graco 3A0410D alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Graco 3A0410D, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Graco service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Graco 3A0410D.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Graco 3A0410D item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Operation Husky ® 3300 Air -Operated Diaphra gm Pump 3A0410D EN Heavy-duty 3-inc h pump with large flo w paths for fluid transf er applications, inc luding high-viscosity materials. For professional use onl y . See page 4 for model inf ormation, including appr ov als. 125 psi (0.86 MP a, 8.6 bar) Maximu m Wo rking Pressure, Alumin um or Stainless [...]

  • Page 2

    Related Manua ls 2 3A0410D Contents Related M anuals . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 T o Order a New Pump . . . . . . . . . . . . . . . . . . . . . . . 3 T o Order Replacement Parts . . . . . . . . . . . . . . . . . 3 Distributor Note . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Configuration Number Matrix . . .[...]

  • Page 3

    To Find Your Nearest Distributor 3A0410D 3 T o Find Y our Nearest Distrib utor 1. Visit www .graco .com . 2. Click on Where to Buy and use the Distributor Locator . T o Specify the Configuration of a Ne w Pump Please call y our dist ribut or . OR 1. Use the Online Husky Sel ector T ool at wwwd.graco .com/training/husky/inde x .html. 2. If the link [...]

  • Page 4

    Configuration Numb er Matrix 4 3A0410D Configuration Number Matrix Chec k the identification plate (ID) f or the 20-digit Configuration Number of y our pump . Use the follo wing matrix to define the components of y our pump . Sample Configuration Number: 3300A-A01AA1 TP A CTPBN * Models with Buna-N, FKM Flu oroelastomer or TPE se ats do not use o-r[...]

  • Page 5

    Warnings 3A0410D 5 Wa r n i n g s The f ollowing w arnings are fo r the setup , use , grounding, maint enance, and repair of this equipment. The e xclama- tion point symbol ale r ts you to a gener al warning and the hazard symbols ref er to procedure-specific risks. When these symbols appear in the body of this man ual, ref er ba c k to these W ar [...]

  • Page 6

    Warnings 6 3A0410D EQUIPMENT MISUSE HAZARD Misuse can cause death or serious injury . • Do not oper ate the unit when fa tigued or under th e influence of drugs or alcohol. • Do not e xceed the maxim um working pressure or te mperature r ating of the lo west r ated system component. See T echnical Da ta in all equipment man uals. • Use fluids[...]

  • Page 7

    Warnings 3A0410D 7 T O XIC FLUID OR FUMES HAZARD T o xic fluids or fumes can cause serious injur y or death if splashed in the e y es or on skin, inhaled, or swa ll ow e d . • Read MSDSs to kno w the specific hazards of the fluids y ou are using. • Route e x haust a wa y from work area. If diaphr agm ruptures, f luid ma y be e xhausted into t h[...]

  • Page 8

    Installation 8 3A0410D Installation Overview The T ypical Installation shown in F IG . 1 is only a guide f or selecting and installing system components. Contact your Gr aco distributor f or assistance in planning a sys- tem to suit your needs. Reference letters in the text, f or e xample (A), r ef er to the callouts in the figures. Key: Accessorie[...]

  • Page 9

    Installation 3A0410D 9 Tighten F asteners Bef ore mountin g and using the pump f or the first time, chec k and retorq ue all e xternal f asteners . F ollo w T orque Instructio ns , page 14, o r see the torque tag on yo ur pump . After the f irst da y of opera tion retorque the f asteners . Mount the Pump 1. V er ify that the bolts ho lding the pump[...]

  • Page 10

    Installation 10 3A0410D Solvent container s used when flushing: F ollow local code. Use only conductiv e metal containers, placed on a grounde d surf ace. Do not place the container on a non- conductive surface , such as paper or cardboard, which interrupts groun ding continuity . Check yo ur syste m electr ical cont inuity after th e initial insta[...]

  • Page 11

    Installation 3A0410D 11 Air Exhaust V e ntilation . T o provide a remote exhaust: 1. Remov e the muffler (U) from the pu mp air e xhaust por t (K). 2. Install a grou nded air e xhaust hose (S) a nd connect the muff ler (U) to the othe r end of the hose . Use muffler PN 111897, sold separ ately . The minimum size f or the air e xhaust hose is 1 in .[...]

  • Page 12

    Operation 12 3A0410D Operation Pressure Relief Pr ocedure 1. Shut off the air supply to th e pump . 2. Open the dispensing v alv e, if used. 3. Open the fluid dr ain v alv e (F) to relie v e fluid pres- sure. Ha ve a container r eady to catch the dr ainage . Flush the Pump Bef ore Fir st Use The pump w as tested in wa ter . If water could contami- [...]

  • Page 13

    Operation 3A0410D 13 Pump Shutdown At the end of the w ork shift and bef ore y ou chec k, adjust, clean or repair the system, follow the Pressure Relief Pr ocedure , page 12. Maintenance Maintenance Schedule Estab lish a pre v entiv e maintenance schedule ba sed on the pump’ s ser vice histor y . Scheduled maintenance is especially impor tant to [...]

  • Page 14

    Operation 14 3A0410D T or que Instructions See F IG . 5 fo r fluid cov er and air valv e fastener s. See F IG . 6 f or manif old fasten ers. NO TE: Fluid cov er and manifold f asteners on the poly- propylene pumps hav e a thread-locking adhesive patch applied to the threads. If this pa tch is excessiv ely wor n, the f asteners ma y loosen during op[...]

  • Page 15

    Operation 3A0410D 15 F IG . 6. T orque Instructions - Manifold F asteners Polypropylene ti16564a 10 9 11 12 13 14 15 16 17 18 19 20 21 22 23 24 1-8 Aluminum ti16559a 12 11 10 9 14 13 15 16 1-8 12 5 1 4 8 10 11 6 3 2 7 9 Stainless Steel ti17457a[...]

  • Page 16

    Aluminum Pump Dimension s 16 3A0410D Aluminum Pump Dimensions ti16557a ti16558a ti16559a A B D C E F G Air Inlet (opposite side from muffler) H J K L M A 24.50 in. (62. 2 cm) B 28.63 in. (72. 7 cm) C 4.13 in. (10.5 cm) D 32.56 in. (82. 7 cm) E 12.04 in. (30. 6 cm) F 24.08 in. (61. 2 cm) G 19.70 in. (50 .0 cm) H 8.25 in. (21.0 cm) J 16.91 in. (42 .9[...]

  • Page 17

    Polypropylene Pump Dimensi ons 3A0410D 17 P olypr opylene Pump Dimensions ti16562a ti16563a ti16564a A B C D H J K L E F G Air Inle t (opposite side from muffler) M A 36.80 in. (93. 5 cm) B 41.40 in. (105.2 cm) C 45.34 in. (115.2 cm) D 4.60 in. (11.7 cm) E 14.56 in. (37. 0 cm) F 29.12 in. (74. 0 cm) G 26.69 in. (67. 8 cm) H 8.30 in. (21.1 cm) J 16.[...]

  • Page 18

    Stainless Steel Pump Dimension s 18 3A0410D Stainless Steel Pump Dimensions ti17455a ti17456a ti17457a A B C D H J K L E F G M Air Inlet (opposite side from muffler) A 23.8 in. (60.5 cm) B 27.88 in. (70. 8 cm) C 30.5 in. (77.5 cm) D 4.5 in. (11.4 cm ) E 12.34 in. (31. 3 cm) F 24.68 in. (62. 7 cm) G 19.38 in. (49 .2 cm) H 8.25 in. (21.0 cm) J 16.91 [...]

  • Page 19

    Performance Charts 3A0410D 19 Pe r f o r m a n c e C h a r t s T est Conditions: Pump tested in wate r with inlet submerged . A B C D How to Read the Charts 1. Locate fluid f low r ate along bottom of chart. 2. F ollow v er tical line up to intersection with selec ted operating air pressure curve . 3. Follow left to scale to read fluid outlet press[...]

  • Page 20

    Technica l Data 20 3A0410D T echnical Data Husky 3300 US Metric Maxim um fluid w orking pressure Aluminum or Stainle ss Steel with Aluminum Center Sectio n 125 psi 0.86 MPa, 8.6 bar P olypropylene or Stainless Steel with P olypropylen e Center Section 100 psi 0.7 MP a, 7 bar Air pressure operating range** Aluminum or Stainle ss Steel with Aluminum [...]

  • Page 21

    Technical Data 3A0410D 21 Inlet/Outlet Si zes Fluid inlet - P olyprop ylene 3 in. ANSI/DIN flange Fluid inlet - Aluminum 3 in.-8 npt or 3 in. -11 bspt with 3 in. ANSI/DIN flange Fluid inlet - Stainless St eel 3 in.-8 npt or 3 in.-1 1 bspt Air Inlet - all p umps 3/4 in. npt( f) We t t e d p a r t s All pumps Materials chosen f or seat, ball, and dia[...]

  • Page 22

    Technica l Data 22 3A0410D Fluid T emperature Range * Th e maximum tempe rature liste d is based on the A TEX standard f or T4 temperature cla ssification. If y ou are operat ing in a non-e xplosiv e en vironment, FKM f luoroelastomer’ s maximum fluid temper ature in alumin um pumps is 320°F (160°C). NO TICE T emperature limits are ba sed on me[...]

  • Page 23

    Technical Data 3A0410D 23[...]

  • Page 24

    All written and visual data con tained in th is document reflects the late st product information availabl e at the time of publica tion. Graco reserves the right to make changes at any time without notice. Original instructions. This manua l contains English. MM 3A0410 Graco Headquarters: Minneapoli s Internationa l Offices: Belgium, China, Japan,[...]