Go to page of
Similar user manuals
-
Camping Equipment
Graham Field 753003
9 pages 0.1 mb -
Camping Equipment
Graham Field 750000
20 pages 0.46 mb -
Camping Equipment
Graham Field AQ1000/AQ2000
16 pages 0.35 mb -
Camping Equipment
Graham Field ALTADYNE 753003
9 pages 0.1 mb -
Camping Equipment
Graham Field 753004
9 pages 0.1 mb -
Camping Equipment
Graham Field 765000
24 pages 0.64 mb -
Camping Equipment
Graham Field 760000-INS-LAB-RevA08
16 pages 0.99 mb -
Camping Equipment
Graham Field 763400A
15 pages 0.27 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Graham Field 763400A, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Graham Field 763400A one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Graham Field 763400A. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Graham Field 763400A should contain:
- informations concerning technical data of Graham Field 763400A
- name of the manufacturer and a year of construction of the Graham Field 763400A item
- rules of operation, control and maintenance of the Graham Field 763400A item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Graham Field 763400A alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Graham Field 763400A, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Graham Field service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Graham Field 763400A.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Graham Field 763400A item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
O O p p e e r r a a t t o o r r s s M M a a n n u u a a l l GF0500067REV A05 L o w Air L oss T her ap y Matt r ess Repla cement S y stem Model # 763400A P P l l e e a a s s e e r r e e a a d d t t h h e e m m a a n n u u a a l l b b e e f f o o r r e e u u s s e e[...]
-
Page 2
Contents Important Safeguards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 Product Description . . . . . . . . . . . . . . . . . . . . . . . . .[...]
-
Page 3
2 IMPORT ANT SAFEGUARDS READ ALL INSTRUCTIONS BEFORE USING DANGER - T o reduce the risk of electrocution: 1. Always unplug this product immediately after using. 2. Do not use while bathing. 3. Do not place or store product where it can fall or be pulled into a tub or sink. 4. Do not place in or drop into water or other liquid. 5. Do not reach for a[...]
-
Page 4
3 1. Introduction This manual should be used for initial set up of the system and for reference purposes. 1.1 General Information LumexAir systems use most advanced technologies and mattress materials to deliver the best quality , comfort and whisper-quiet operations to you and your customers. Most systems in LumexAir are recommended for prevention[...]
-
Page 5
4 2. Product Description 2.1 Pump and Mattress System 1. Mattress 2. Pump unit 3. Air tube connector 4. Control Panel The system consists of a high volume airflow blower and numerous large air loss holes on the mattress to achieve the true low air loss therapy . It also provides excellent ventilation and keeps patients dry from humidity . The 10 in[...]
-
Page 6
5 3. Installation 3.1 Unpacking The pump unit and mattress are packaged in a separate box to secure its contents inside. Unpacking these boxes to remove the pump unit and mattress and check for any damage, which may have occurred in shipping. If there are damages, please contact your dealer immediately . 1. Place the mattress on top of the bed fram[...]
-
Page 7
6 4. Plug into main electrical outlet. NOTE 1. Make sure the pump unit is suitable for the local power voltage. 2. The plug also serves as the disconnect device CAUTION: The pump can only be applied to the mattress recommended by the manufacturer . Do not use it for any other purpose. 5 Then turn the main power switch ON. The power switch is locate[...]
-
Page 8
7 4. Operation NOTE: Always read the operating instructions before use. 4.1 Function Description: Control Button Function Description POWER T wo conditions: 1. T o turn on control unit. It takes approximately 1 minute to inflate the mattress. The default setting is at a comfort range, level 6, for the quickest inflation time. 2. T o turn off Power [...]
-
Page 9
8 Control Button Function Description AUTOFIRM For maximum inflation of mattress. All other functions are disabled unless this button is pressed again. This mode will last for 20 minutes and then it will return to default setting automatically . ST A TIC For true low air-loss therapy mode, similar to a regular air mattress with very low air pressur[...]
-
Page 10
9 4.2 Operating Instruction 1. Press the POWER button on the display panel to start the system. 2. For faster inflation, the AUTOFIRM function can be activated. This mode will last for 20 minutes and then it will return to default setting automatically . 3. After the mattress is fully inflated, user can change the setting according to their prefere[...]
-
Page 11
10 NOTE: If the pressure level is consistently low , check for any leakage at air cells or connecting tubes. If necessary , replace any damaged cells or tubes or contact local qualified dealer for repair . If the control unit is equipped without audible alarm feature, the Low Pressure Indicator will flash until the low-pressure fault condition is s[...]
-
Page 12
11 6. Storage 1. Pull the CPR tags and make sure all cells are deflated. 2. Lay the mattress out flat and upside down. 3. Protect the air tube coupler by putting it in the inner side of mattress. 4. Roll the mattress from the head end towards the foot end. 5. Foot-end straps can then be stretched around the rolled mattress to prevent unrolling. 7. [...]
-
Page 13
12 Problem Solution Power is not ON • Check if the plug is connected to main power . • Check if there is any blown fuse. Alarm is on (audible & visual) • Check if the connection between air tube connector to pump unit is tightly secured. • Check if the CPR is sealed. • Check if there are any leakage on air cells. • Check if all tubi[...]
-
Page 14
13 Pump Specification Power Supply ( Note: See rating label on the product) 120V AC 60Hz, 1A (For 120V system) 230V AC 50Hz, 7W ( For 230V system) Fuse Rating 5A (For 120V system), T3A ( For 230V system) Dimension 37 x 27 x 13 (cm) or 14.4" x 10.5" x 5" Weight 4.5 kg or 9.9 lb Environment T emperature Operation:10° C to 40° C (50°[...]
-
Page 15
U.S.A., Corporate Headquar ters: Graham-Field Health Pr oducts 2935 Northeast Parkway Atlanta, Geor gia 30360 telephone: 800-347-5678, 770-447-1609 fax: 800-726-0601, 678-291-3232 http://www .grahamfield.com[...]