Graham Field AQ1000/AQ2000 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Graham Field AQ1000/AQ2000, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Graham Field AQ1000/AQ2000 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Graham Field AQ1000/AQ2000. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Graham Field AQ1000/AQ2000 should contain:
- informations concerning technical data of Graham Field AQ1000/AQ2000
- name of the manufacturer and a year of construction of the Graham Field AQ1000/AQ2000 item
- rules of operation, control and maintenance of the Graham Field AQ1000/AQ2000 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Graham Field AQ1000/AQ2000 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Graham Field AQ1000/AQ2000, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Graham Field service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Graham Field AQ1000/AQ2000.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Graham Field AQ1000/AQ2000 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    AQ1000 / AQ2000 AL TERNA TING PRESSURE BUBBLE P AD AND PUMP SYSTEM USER MANUAL Impor tant: Do not operate the Mattress System without rst reading and understanding this manual! Save this manual for future use. The latest version of this manual can be found online at www.grahameld.com. AQ1000-INS-LAB-RevC1 1[...]

  • Page 2

    2 AQ1000-INS-LAB-RevC11 CONTENTS INTRODUCTION..................................................................................... 3 INTENDEDUSEOFTHISDEVICE ........................................................ 3 CONTRAINDICA TION ...................................................................... 3 DANGER .........[...]

  • Page 3

    AQ1000-INS-LAB-RevC11 3 INTRODUCTION Use this manual for setup and operation of the Lumex AQ1000 / AQ2000 Alternating Pr essur e Pad and Pump System. Read all instructions befor e using the pad and pump system. Save this manual for futur e r eference. INTENDED USE OF THIS DEVICE The intended use of the Alternating Pr essur e Pad and Pump System,[...]

  • Page 4

    4 AQ1000-INS-LAB-RevC11  CAUTION:Indicatesapotentialhazardorunsafe practicethat,ifnotavoided,couldresultinminoror moderatepersonalinjury . s  NOTICE:Indicatesapotentialhazardorunsafepractice that,ifnotavoided,couldresultinproductorpr[...]

  • Page 5

    AQ1000-INS-LAB-RevC11 5  W ARNING:Neveroperatethisproductif a) ithasadamagedcordorplug. b) itisnotworkingproperly . c) ithasbeendroppedordamaged. d) ithasbeendroppedintowater .  ReturntheproducttoyourGraham-Fieldequipment[...]

  • Page 6

    6 AQ1000-INS-LAB-RevC11 EQUIPMENT SYMBOLS Attention! Consult accompanying documents (this manual) “BF”symbol: Indicates that this product is in accordance with the degree of protection against electric shock for type BF equipment Grounding terminal Class II (for UL only) Disposal of Electrical & Electronic Equipment (WEEE): Do not treat [...]

  • Page 7

    AQ1000-INS-LAB-RevC11 7 PRODUCT DESCRIPTION B UBBLE P AD AND PUMP SY STEM bubble pad and pump system air tubes bubble pad pump PUMP pump (AQ2000 shown) front panel wire hangers fuses (220V only) air tube connectors[...]

  • Page 8

    8 AQ1000-INS-LAB-RevC11 FRONT P ANEL AQ1000 AQ1000 pump front panel ON/OFF switch air tube connectors AQ2000 AQ2000 pump front panel ON/OFF switch pressur e control dial Fr ont panel pr essur e contr ol dial (AQ2000 only) : The pr essur e control dial contr ols the air pr essure output. T o incr ease pr essure, turn the dial clockwise. T o decr [...]

  • Page 9

    AQ1000-INS-LAB-RevC11 9 INST ALLA TION UNP A CKING 1. Befor e unpacking, check for obvious damage to the carton or its contents. If damage is evident, please notify the carrier and your Graham-Field equipment pr ovider . 2. Remove all loose packing fr om the carton. 3. Car efully r emove all components from the carton. 4. Inspect all components.[...]

  • Page 10

    10 AQ1000-INS-LAB-RevC11 5. Connect one end of the air tubes to the bubble pad: slide the ends of the air tubes over the connectors on the top of the foot end of the bubble pad. 6. Connect the other end of the air tubes to the pump connectors; ensur e that the ends of the air tubes ar e rmly tted over the bubble pad and pump connectors bef[...]

  • Page 11

    AQ1000-INS-LAB-RevC11 11 OPERA TION 1. T urn the ON/OFF switch to the ON position. The pump will begin to deliver air into the bubble pad. 2. Replace all sheets, blankets, and pillows on the bed. Info: if the pressure level seems low , check for any leakage in the air tubes or bubble pad. Replace any damaged tubes. If necessar y , contact your G[...]

  • Page 12

    12 AQ1000-INS-LAB-RevC11 MAINTENANCE CLEANING Perform the following cleaning pr ocedur es before use and as necessar y thereafter . Pump W ipe the pump with a clean, damp cloth and mild deter gent, and keep it away from dust. Air dr y . s  NOTICE:Donotusephenolicproductsorcorrosiveor powderedcleanserstoclea[...]

  • Page 13

    AQ1000-INS-LAB-RevC11 13 Fuse replacement (220V system onl y) tool needed: small screwdriver 1. If you suspect a blown fuse, disconnect the plug fr om the wall outlet immediately . fuse location fuse fuse cover 2. Use a small scr ewdriver to r emove the cover of the fuse holder (fuse locations ar e shown in pictur e above). 3. Insert a new fuse [...]

  • Page 14

    14 AQ1000-INS-LAB-RevC11 SPECIFICA TIONS Model AQ1000 (Standard) AQ2000 (Delux e) P ow er Supply 120V : 120V AC, 60 Hz, 1A 220V : 230V AC, 50 Hz, 7W Fuse Rating 120V : N/A 220V : T1A, 250V Pressur e 1.9 psi (13.10 kPa) 1.0 - 2.0 psi (6.89-13.79 kPa) Air Output 120V : 4.5 LPM 120V : 4-5 LPM 220V : 5.0 LPM 220V : 5-6 LPM Cyc le Time 120V : 5 min. [...]

  • Page 15

    AQ1000-INS-LAB-RevC11 15 WARRANTY GF Health Pr oducts, Inc. warrants the Lumex AQ1000 / AQ2000 Alternating Pr essur e Pad and Pump System for defects in workmanship and materials for the terms listed below . Pump: one year Pad: 90 days If a pr oduct is deemed to be under warranty , GF Health Pr oducts, Inc. shall pr ovide, at its option, (1) r e[...]

  • Page 16