The rules should oblige the seller to give the purchaser an operating instrucion of Greenheck Fan 474118, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Greenheck Fan 474118 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Greenheck Fan 474118. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Greenheck Fan 474118 should contain:
- informations concerning technical data of Greenheck Fan 474118
- name of the manufacturer and a year of construction of the Greenheck Fan 474118 item
- rules of operation, control and maintenance of the Greenheck Fan 474118 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Greenheck Fan 474118 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Greenheck Fan 474118, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Greenheck Fan service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Greenheck Fan 474118.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Greenheck Fan 474118 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    1 V ektor -ERS Energy Recovery Plenum Laboratory Exhaust Installation, Operation and Maintenance Manual Please read and save these instructions. Read car efully before attempting to assemble, install, operate or maintain the product described. Pr otect yourself and others by observing all safety information. Failure to comply with instructions coul[...]

  • Page 2

    2 V ektor ERS-MD Energy Recovery Plenum Laboratory Exhaust Remove any accumulations of dirt, water , ice or snow and wipe dry before moving to indoor storage. T o avoid “sweating” of metal parts allow cold parts to reach r oom temperature. T o dry parts and packages use a portable electric heater to get rid of any moisture build up. Leave cover[...]

  • Page 3

    3 V ektor ERS-MD Energy Recovery Plenum Laboratory Exhaust Removing from Storage As fans are r emoved from storage to be installed in their final location, they should be protected and maintained in a similar fashion, until the fan equipment goes into operation. Prior to assembly and installation of the V ektor fan and system components, inspect t[...]

  • Page 4

    4 V ektor ERS-MD Energy Recovery Plenum Laboratory Exhaust CAUTION When installing an ERS plenum cabinet, ensure the proper protective devices are used to protect personnel from moving parts and other hazards. Check local codes to ensure compliance for all protective devices. ERS plenum cabinet with coil section should be lifted/ hoisted by lifting[...]

  • Page 5

    5 V ektor ERS-MD Energy Recovery Plenum Laboratory Exhaust Plenum Service Clearances and Access Locations ERS plenum cabinet and V ektor fan bypass air plenum (BAP) requir e minimum clearances for access on three sides for routine maintenance. Filter r eplacement, drain pan inspection and cleaning, coil inspection, damper actuator adjustments and i[...]

  • Page 6

    6 V ektor ERS-MD Energy Recovery Plenum Laboratory Exhaust 5. Set the Vektor fan bypass air plenum Before moving the V ektor fan BAP into position, gasketing must be installed to seal the plenum sections against leakage. This gasketing is attached to the ERS plenum cabinet prior to shipment. V erify that it is in place and not damaged or missing pr[...]

  • Page 7

    7 V ektor ERS-MD Energy Recovery Plenum Laboratory Exhaust Duct Connections Plenum Bottom Inlet Opening Plenum Side Inlet Duct Dimension Cabinet Size Length (inches) Width (inches) 020 86 25 030 120 25 040 172 25 060 236 25 Cabinet Size Length (inches) Height (inches) 020 86 30 030 120 30 040 172 30 060 236 30 Length Gasket or Sealant (by others) G[...]

  • Page 8

    8 V ektor ERS-MD Energy Recovery Plenum Laboratory Exhaust Drain T rap Coils are pr ovided with a stainless steel drain pan with 1 1/4-inch male NPT drain connection. A drain trap must be connected to the drain connection to allow excess water to flow out of the drain pan. More importantly though, due to the negative internal static pressur e of t[...]

  • Page 9

    9 V ektor ERS-MD Energy Recovery Plenum Laboratory Exhaust Coil Installation Checklist Use the following checklist to verify that all necessary installation procedur es have been completed. 1 . Coil s ar e inst a lled w ith a ir flow in sa me dir ec tion as in dica ted on th e coil n ame plate o r cas ing. 2. Con den sate dr a in pa ns an d pipin [...]

  • Page 10

    10 V ektor ERS-MD Energy Recovery Plenum Laboratory Exhaust V ektor Field Coating T ouch-up Pr ocedure for Scratched Areas Standard coating and color for the V ektor laboratory exhaust system is Greenheck’ s LabCoat™ – Industrial Gray (041). The procedur e below details the correct method for repairing minor scratches in the coating. 1. Scuff[...]

  • Page 11

    11 V ektor ERS-MD Energy Recovery Plenum Laboratory Exhaust Routine Maintenance CAUTION Use caution when removing access panels or other unit components, especially while standing on a ladder or other potentially unsteady base. Access panels and unit components can be heavy and serious injury may occur. Once the unit has been put into operation, a [...]

  • Page 12

    12 474118 •ModelVKERS-MDIOM,Rev .1,April2011 Copyright 2011 © Greenheck Fan Corp. Greenheck warrants this equipment to be fr ee from defects in material and workmanship for a period of one year from the shipment date. Any units or parts which prove defective during the warranty period will be r eplaced at our option when [...]