Greenheck Fan LFC manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Greenheck Fan LFC, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Greenheck Fan LFC one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Greenheck Fan LFC. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Greenheck Fan LFC should contain:
- informations concerning technical data of Greenheck Fan LFC
- name of the manufacturer and a year of construction of the Greenheck Fan LFC item
- rules of operation, control and maintenance of the Greenheck Fan LFC item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Greenheck Fan LFC alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Greenheck Fan LFC, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Greenheck Fan service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Greenheck Fan LFC.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Greenheck Fan LFC item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Only qualified personnel should install this unit. Personnel should have a clear understanding of these instructions and should be aware of general safety precautions. Impr oper installation can result in electric shock, possible injury due to coming in contact with moving parts, as well as other potential hazards. Other considerations may be requ[...]

  • Page 2

    2 Model LFC Low-Profile Fan Coil ® The unit should be stored at least 3½ in. (89 mm) of f the floor on wooden blocks covered with moistur e proof paper or polyethylene sheathing. Aisles between parts and along all walls should be provided to permit air circulation and space for inspection. Inspection and Maintenance during Storage While in stora[...]

  • Page 3

    3 Model LFC Low-Profile Fan Coil ® T able of Contents Installation U n i t L a y o u t .............................. . 3 Lifting / Hanging Instructions ................ 3 Dimensions / Weights ...................... 4 Filter Sizes / Quantity . . . . . . . . . . . . . . . . . . . . . . 4 C o i l D i m e n s i o n s ......................... 5 - 6 S[...]

  • Page 4

    4 Model LFC Low-Profile Fan Coil ® Unit Dimensions Unit Size I J K Width Inlet Outlet w/o Filter w/ 2 in. Filter w/ 4 in. Filter Height Width Height Width 15 40 42 44 8.0 11.0 38 9.0 36 4.0 6.75 20 40 42 44 11.0 14.0 38 12.0 36 6.5 6.75 25 40 42 44 13.0 16.0 38 14.0 36 8.0 8.5 30 45 47 49 15.5 18.5 38 16.5 36 9.0 9.0 45 45 47 49 14.25 18.5 50 16.5[...]

  • Page 5

    5 Model LFC Low-Profile Fan Coil ® Coil Dimensions NOTE Fluid enters the coil from the bottom connection (Inlet) and exits from the top (Outlet). Hot W ater • 1 and 2 Row Unit Size A B 15 7.63 0.75 20 10.13 0.75 25 12.63 0.875 30 15.13 0.875 45 15.13 0.875 50 17.63 1.125 65 22.63 1.375 85 22.63 1.375 All dimensions are in inches. B Copper Sweat [...]

  • Page 6

    6 Model LFC Low-Profile Fan Coil ® Unit Size A B 4 row 6 row 8 row CDCDCD 30 12.00 7.00 0.625 0.625 0.625 0.875 0.625 0.875 45 12.00 7.00 0.625 0.625 0.625 0.875 0.625 0.875 50 13.50 7.75 0.625 0.625 0.625 0.875 0.625 1.125 65 17.00 9.50 0.875 0.875 0.875 1.125 0.875 1.125 85 17.00 9.50 0.875 0.875 0.875 1.125 0.875 1.125 All dimensions are in inc[...]

  • Page 7

    7 Model LFC Low-Profile Fan Coil ® System Start-Up For proper unit function and safety , follow everything in this start-up procedur e in the order pr esented. This is to be done after the electrical connections are complete. PRE-ST ART CHECK LIST 1. Disconnect and lock-out all power switches to fan. 2. Check all fasteners, set screws and locking [...]

  • Page 8

    8 Model LFC Low-Profile Fan Coil ® Symptom Possible Cause Corrective Action Blower fails to operate Blown fuse or open circuit br eaker Replace fuse or reset cir cuit breaker and check amps Broken fan belt Replace Defective motor or capacitor Replace Motor starter overloaded Reset starter and check amps Motor overamps Airflow too high Check airflo[...]

  • Page 9

    9 Model LFC Low-Profile Fan Coil ® Hot W ater , Chilled W ater Coils 1. Piping should be in accordance with accepted industry standards. Pipework should be supported independently of the coils. Water pipes are copper with sweat connections. USE WET TOWEL TO AVOID BURNING COIL CONNECTION GROMMETS. When installing coupling, do not apply undue stress[...]

  • Page 10

    10 Model LFC Low-Profile Fan Coil ® Steam Coils, General - continued 3. Standard steam coils are pitched in the casings when installed for horizontal airflow. The casing must be level after the unit is installed for proper condensate drainage. If condensate is not removed, the coil will suffer from water hammering and will have a shortened life. O[...]

  • Page 11

    11 Model LFC Low-Profile Fan Coil ® Y early Bearings — Most bearings are permanently lubricated and requir e no further lubrication under normal use. Normal use being considered -20ºF to 120ºF and in a relatively clean envir onment. Some bearings are r elubricatable and will need to be regr eased depending on fan use. Check your bearings for g[...]

  • Page 12

    12 Model LFC Low-Profile Fan Coil ® Coil Maintenance Start-Up Documentation CAUTION Fin edges are sharp. Coils must be clean to obtain maximum performance. Check once a year under normal operating conditions and, if dirty , brush or vacuum clean. Soiled fins reduce the capacity of the coil, demand more energy fr om the fan, and create an envir on[...]

  • Page 13

    13 Model LFC Low-Profile Fan Coil ® Maintenance Log Date __________________ Time _____________ AM/PM Notes:___________________________________________ _________________________________________________ _________________________________________________ _________________________________________________ ________________________________________________[...]

  • Page 14

    14 Model LFC Low-Profile Fan Coil ® Maintenance Log Date __________________ Time _____________ AM/PM Notes:___________________________________________ _________________________________________________ _________________________________________________ _________________________________________________ ________________________________________________[...]

  • Page 15

    15 Model LFC Low-Profile Fan Coil ® Maintenance Log Date __________________ Time _____________ AM/PM Notes:___________________________________________ _________________________________________________ _________________________________________________ _________________________________________________ ________________________________________________[...]

  • Page 16

    16 464496 • LFC, Rev . 1, August 2004 Copyright 2004 © Greenheck Fan Corporation Greenheck warrants this equipment to be fr ee from defects in material and workmanship for a period of one year fr om the shipment date. Any units or parts which prove defective during the warranty period will be r eplaced at our option when returned to our factory [...]