Go to page of
Similar user manuals
-
Indoor Fireplace
Hearth and Home Technologies CFL-30NG-C
28 pages 1.31 mb -
Indoor Fireplace
Hearth and Home Technologies 6000GL-IPI-R
70 pages 3.38 mb -
Indoor Fireplace
Hearth and Home Technologies 8000TR-OAK-IPI
70 pages 3.98 mb -
Indoor Fireplace
Hearth and Home Technologies HUDBAY-INS
37 pages 3.34 mb -
Indoor Fireplace
Hearth and Home Technologies CASTILE-GAS-CWL
56 pages 3.22 mb -
Indoor Fireplace
Hearth and Home Technologies TRUE-36
80 pages 5.1 mb -
Indoor Fireplace
Hearth and Home Technologies CNXT4842IT
80 pages 8.84 mb -
Indoor Fireplace
Hearth and Home Technologies Columbia Bay Insert
2 pages 0.37 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Hearth and Home Technologies BIR42-B, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Hearth and Home Technologies BIR42-B one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Hearth and Home Technologies BIR42-B. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Hearth and Home Technologies BIR42-B should contain:
- informations concerning technical data of Hearth and Home Technologies BIR42-B
- name of the manufacturer and a year of construction of the Hearth and Home Technologies BIR42-B item
- rules of operation, control and maintenance of the Hearth and Home Technologies BIR42-B item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Hearth and Home Technologies BIR42-B alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Hearth and Home Technologies BIR42-B, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Hearth and Home Technologies service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Hearth and Home Technologies BIR42-B.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Hearth and Home Technologies BIR42-B item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
1 Owner ’ s Manual Installation and Operation Models: BIR42-B Wood Burning Fireplace DO NOT DISCARD THIS MANUAL NOTICE • Important operating and maintenance instructions included. • Leave this manual with party responsible for use and operation. • Read, understand and follow these instructions for safe installation and operation. DO NOT DIS[...]
-
Page 2
2 Read this manual before installing or operating this replace. Please retain this owner ’ s manual for future reference. Homeowner Reference Information Model Name: Date purchased/installed: Serial Number: Location on replace: Dealership purchased from: Dealer phone: Notes: We recommend that you record the following pertinent information a[...]
-
Page 3
3 Safety Alert Key: • DANGER! Indicates a hazardous situation which, if not avoided will result in death or serious injury . • W ARNING! Indicates a hazardous situation which, if not avoided could result in death or serious injury . • CAUTION! Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury . ?[...]
-
Page 4
4 W arranty 4021-645C 12-29-10 Page 1 of 2 Hearth & Home T echnologies Inc. LIMITED LIFETIME W ARRANTY Hearth & Home T echnologies Inc., on behalf of its hearth brands (”HHT”), extends the following warranty for HHT gas, wood, pellet, coal and electric hearth appliances that are purchased from an HHT authorized dealer . W ARRANTY COVERA[...]
-
Page 5
5 4021-645C 12-29-10 Page 2 of 2 W ARRANTY CONDITIONS: • This warranty only covers HHT appliances that are purchased through an HHT authorized dealer or distributor . A list of HHT authorized dealers is available on the HHT branded websites. • This warranty is only valid while the HHT appliance remains at the site of original installation. • [...]
-
Page 6
6 1 Listing and C ode A ppro vals Notice: This replace is tested and approv ed as a decorative rep lace. It should not be fac tored as a primar y heat sourc e in residentia l heating calculati ons. W ARNING! Risk of Fire! Hearth & Home T echnologies disclaims any responsibility for , and the warranty and agency listing will be voided by t[...]
-
Page 7
7 2 Operating Inst ruct ions W ARNING! DO NOT operate replace before reading and understanding operating instructions. Failure to operate replace according to operating instructions could cause re or injury . User Guide W ARNING Hot screen/mesh and glass doors will cause burns. • Do not touch screen/mesh or glass doors until cooled ?[...]
-
Page 8
8 D. Grate This replace is designed to be used with the grate sup- plied with this unit or one approved by HHT . The grate will deteriorate over time and will need occasional replacement. W ARNING! Risk of Fire! Use only the factory-supplied integral grate. • Keeps logs in place. • Allows proper air circulation around the re. E. Firescree[...]
-
Page 9
9 W ARNING! Risk of Fire and Smoke! Fireplaces equipped with doors should be operated only with doors fully open or doors fully closed. If doors are left partly open, gas and ame may be drawn out of the replace opening. FULL Y OPEN CORRECT P ARTL Y CLOSED INCORRECT P ARTL Y OPEN INCORRECT FULL Y CLOSED CORRECT Figure 2.2 Operating Positions[...]
-
Page 10
10 M. Wood Fuel Hardwood vs Softwood Y our replace performance depends on the quality of the rewood you use. • Seasoned wood contains about 8,000 BTUs per pound . • Hard woods are more dense than soft woods. • Hard woods contain 60% more BTUs than soft woods. • Hard woods require more time to season, burn slower and are harder to igni[...]
-
Page 11
1 1 3 Maintenance and Ser vice A. Disposal of Ashes Frequency: When they reach bottom of grate By: Homeowner B. Chimney Inspection/Cleaning Frequency: At least twice a year during heating season or as recommended by a certied chimney sweep By: Certied chimney sweep Figure 3.1 Chimney & T ermination Cap Cleaning W ARNING! Risk of Fire! Ash[...]
-
Page 12
12 C. Check Firebox Molded Brick Panel Frequency: After each ash removal By: Homeowner D. Inspect Grate Frequency: After each ash removal By: Homeowner Inspect grate for: • W arping or sagging 1-1/2 in. (38 mm) or more • Broken welds • Burn-through of grate bars For safe operation, replace only with the approved grate from Hearth & Homes [...]
-
Page 13
13 4 T rou ble sh ooting Guide Start Fire Problems Possible Cause Solution Can’t get re started Excessive smoke or spillage Burns too slowly Smolders, sizzles Not enough kindling/paper or no kindling/paper Use dry kindling, more paper . Arrange kindling & wood for air movement. Damper closed/not fully open Open damper . Not enough air for [...]
-
Page 14
14 Non-combustible roof flashing maintains minimum clearance around chimney Additional lateral support for chimney above roof (or enclosed in chase) if needed (Section 8.A.) Ceiling firestop on floor of attic (Section 8.D.) Support straps on rafter supports chimney (not shown) T ermination cap (Sections 8.I., 9.D.) Chimney penetrates roof preferabl[...]
-
Page 15
15 B. Design and Installation Considerations Draft is the pressure difference needed to vent replaces successfully . When a replace is drafting successfully , all combustion by-products are exiting the home through the chimney . Considerations for successful draft include: • Preventing negative pressure • Location of replace and chimne[...]
-
Page 16
16 Marginal Location: • Below peak Location NOT recommended: • Not the highest point of the roof • Wind loading possible Multi-level Roofs Windward Leeward Recommended Location: • Above peak Recommended: • Insulated exterior chase in cooler climates Recommended Location: • Above peak • Inside heated space Location NOT recommended: •[...]
-
Page 17
17 Before beginning the installation be sure the following tools and building supplies are available: Reciprocating saw Framing material Pliers Non-combustible sealant Hammer Gloves Phillips screwdriver Framing square Flat blade screwdriver Electric drill and bits Plumb line Safety glasses Level T ape measure 1/2-3/4 in. length, #6 or #8 self-drill[...]
-
Page 18
18 6 F raming & Clearances A F D B C 5/8 in. (16 mm) all configurations 1-1/2 in. min. air space from fireplace to combustible materials. 1/2 in. min. air space at nailing flanges. Note: In an exterior chase or projecting into a garage Across a corner As a room divider Along a wall 84 in. (2134 mm) G B E Note: In addition to these framing dimen[...]
-
Page 19
19 B. Clearances W ARNING! Risk of Fire! Y ou must comply with all minimum air space clearances to combustibles as specied in Fig- ure 6.2. DO NOT pack required air spaces with insulation or other materials. Heatilator • Birmingham BIR42-B • 4059-681• 1 1/1 1 (insulation) Attic Insulation Shield (ceiling) (roof) (attic) (ceiling) Ceiling F[...]
-
Page 20
20 D. Frame the Fireplace Figure 6.4 shows typical framing using combustible materials (2x4 lumber shown). • Observe all required air space clearances to combustible materials as shown in Figure 6.2. 18 1/2 in. [470 mm] 19 3/4 in. [500 mm] 4 in. [102 mm] 50° angle 39° angle 24 in. [610 mm] BRICK FRONT FLUSH FRONT 24 in. [610 mm] 22 3/8 in. [568[...]
-
Page 21
21 7 Installation of F ireplace CAUTION! Risk of Cuts/Abrasions. Wear protective gloves and safety glasses during installation. Sheet metal edges are sharp. A. Things to Consider • Location(s) of outside air kit(s) • Gas line piping B. Position the Fireplace • Place the replace on a continuous at surface. • Follow framing instructions[...]
-
Page 22
22 Outlet placed higher than 3 ft below the termination cap Attic space Garage or combustible liquids storage Outlet blocked by snow , leaves, etc. Clear area outside house or in ventilated crawl space YES NO NO NO NO Factory-built fireplace Use only duct materials specified by manufacturer (preferably with short run or mainly straight duct, except[...]
-
Page 23
23 Outside Air Hood 2 Wire T ies Flexible Duct (not supplied) Figure 7.5 Outside Air Installation E. Install Outside Air Kit • K e e p d u c t r u n s s h o r t a n d s t r a i g h t t o m i n i m i z e restriction. • The outside air kits must be installed on both sides of the replace. W ARNING! Outside air kits must be installed on both sid[...]
-
Page 24
24 Chimney must extend beyond combustible roof structure Maintain minimum height of chimney above roof Additional support for tall chimneys Install roof flashing according to minimum requirements Maintain minimum clearances to combustibles as specified Offsets/returns may not exceed 30° from vertical Lock chimney sections together firmly to resist[...]
-
Page 25
25 A. Chimney Requirements Measure vertical distances from the base of the replace as shown in Figure 8.2. 20 ft (6.10 m) max. pipe between an offset & return Ceiling firestop 35 ft (10.7 m) max. straight unsupported chimney height 18.5 ft (5.64 m) min. height single offset-return 90 ft (27.4 m) max. height 6 ft (1.83 m) max. unsupported chi[...]
-
Page 26
26 T able 8.2 B. Using Offsets/Returns • Use an offset/return to bypass overhead obstructions. • An offset and return can be used as a single entity or separated by chimney section(s). W ARNING! Risk of Fire! DO NOT use offset/returns greater than 30°. Chimney draft will be restricted and could cause overheating and re. • Measure the shif[...]
-
Page 27
27 Figure 8.4 Assembling Chimney Sections • Support the pipe during constructi on and check to be sure inadv ertent loading has not disl odged the chimney secti on from the replace or at any chimney joint. • Attach a straight chimney section or an of fset to the top of the replace. • Place inner ue to the inside of the chimney sectio[...]
-
Page 28
28 ROOM ABOVE (non-insulated ceiling) A TTIC ABOVE (insulated ceiling) B A Ceilng firestop from bottom Ceiling firestop from top Note: Use same dimensional lumber for framing ceiling firestop and joists. Figure 8.5 Installing the Ceiling Firestop • Insta ll a ce iling restop whenev er chim ney pen etrates ceiling/oor . • Mark and cut an [...]
-
Page 29
29 Installation of a ceiling restop is required • Refer to Figures 8.6 - 8.8. • Roll the shield around the chimney (if chimney is already installed) until you have a 3 in. (76 mm) overlap and the three holes on each side match up (large holes on top). • Insert three screws into the matching holes to form a tube. • Bend three tabs on the [...]
-
Page 30
30 G. Complete Installation W ARNING! Risk of Fire! Y ou MUST maintain 2 in. (51 mm) air space to insulation and other combustible ma- terials around the chimney system. Failure to do so could cause overheating and re. • Keep chimney sections from separating or twisting. • Y ou may secure straight chimney sections at the joints with screws n[...]
-
Page 31
31 Slanted Roofs Flat Roofs Chimney must extend 3 ft (.9 m) above the roof Chimney must extend 2 ft (.6 m) above any portion of the roof or adjacent structures within 10 ft (3 m) of the chimney Chimney must extend 3 ft (.9 m) above the roof Chimney must extend 2 ft (.6 m) above any portion of the roof or adjacent structures within 10 ft (3 m) of th[...]
-
Page 32
32 9 Ch ase Inst allations Ceiling Firestop Metal Chase T op Round T ermination Cap False Ceiling Insulation in the outside walls of the chase Attic Insulation Shield Chimney Ceiling Firestop T abs False Ceiling False Ceiling Insulation Insulation Figure 9.1 Chase Assembly 1 2 3 1. Fireplace and chimney enclosed in an exterior chase. 2. Chimney off[...]
-
Page 33
33 Slope Downward (1/4 in. per foot minimum) T urn-down Drip Edge Chase 2 in. (51 mm) Collar on Chase T op .018 (26 ga) min. Galvanized Chase T op Figure 9.3 Chase T op Construction B. Install Fireplace & Chimney Install as per Sections 7 and 8. Heatilator • Birmingham BIR42-B • 4059-681• 1 1/1 1 C. Install Chase T op • Y ou MUST use a [...]
-
Page 34
34 D. Install T ermination Cap Install the chimney sections up through the chase enclo- sure. • Install termination caps following instructions provided with them. W ARNING! Risk of Fire! The minimum overlap of cap to pipe (as shown in the following illustrations) MUST be met or chimney may separate from cap. Separation allows sparks, heat and em[...]
-
Page 35
35 Heatilator • Birmingham BIR42-B • 4059-681• 1 1/1 1 Chimney Pipe Chase T op T ermination Cap Chase Collar 2 in. (51 mm) Minimum Height Remove 2 screws from front & back to lift the top off T ermination cap pipe and chimney section must overlap 1-1/2 in. (38 mm) Place waterproof sealer under each flange of the termination cap and on top[...]
-
Page 36
36 3 in. (76 mm) tall legs Ø 17 1/2 in. (444.5 mm) Round Hole to fit over cap Length x Width to fit inside shroud Figure 10.1 Radiation Shield • Chase top shrouds may be field constructed where permitted by regional building codes. W ARNING! Risk of Fire! Shrouds must be constructed as specied. Improper construction may overheat chase top. NO[...]
-
Page 37
37 3 in. (76 mm) Min. Opening Height Min. Base Dim Min. Height above radiation shield Min. Base Dim 3 in. (76 mm) Min. Radiation Shield Height from top of Chase Min. Opening Width Figure 10.3 Mailbox Style Shroud Dimensions Mailbox Style Shroud (radiation shield required) Roofed Style Shroud (Radiation Shield Required) Minimum Opening Height Minimu[...]
-
Page 38
38 1 1 Installat ion of Molded Brick Panel A. Install Hearth Molded Brick Panel • Place hearth panel into the replace. B. Install Back Molded Brick Panel/T raditional • Remove screen rods • Remove the smokeshield • Refer to Figure 1 1.1. • Set the grate brackets in place, 26.5 in. (673 mm) center to center . • Install the back panel.[...]
-
Page 39
39 Figure 1 1.2 Herringbone Molded Brick Panel D. Install Back Molded Brick Panel - Herring- bone If a gas line is to be installed, remove the knockouts in the inner rebox and in the outer shell on the side of your choice. Refer to dimension drawings for location of knockouts and Section 13.A. for gas provisions. • Refer to Figure 1 1.2. • I[...]
-
Page 40
40 Center of Fireplace Opening Round end of Rod through rings, then into Screen Rod Clip G. Install Mortar (Optional) Figure 1 1.4 Facing Materials and Mortar F . Install Screens • Lay one screen panel at and slide the round end of the rod through the rings starting at the handle side of screen. Leave the last ring off the rod. • Insert the [...]
-
Page 41
41 1 2 F inishing A. Non-combustible Materials • Materials which will not ignite and burn, composed of any combination of the following: - Steel - Iron - Brick - T ile - Concrete - Slate - Glass - Plasters • Materials reported as passing ASTM E 136, Standard T est Method for Behavior of Metals, in a V ertical T ube Furnace at 750° C B. Combust[...]
-
Page 42
42 IMPORT ANT! Hearth ext ension design must be det ermined before installati on of replac e. Floor Non-combustible Framing Material Non-combustible Finishing Material Protective Metal Hearth Strips 1 in. Micore or equivalent insulation & 1/2 in. Durock Bottom of fireplace opening Note: The bottom of the fireplace opening is 3-3/4 in. (95.3m[...]
-
Page 43
43 Non-combustible Sealant After completing the framing and applying the facing mate- rials over the framing, a bead of non-combustible sealant must be used to close off any gaps at the top and sides between the replace and hearth. Non-combustible Sealant Figure 12.7 Flush Hearth Extension Flush Hearth Extension Framing • Fireplace must be rec[...]
-
Page 44
44 These surfaces must be covered with non-combustible material. Non-combustible sealant. D. Finishing Material Refer to Sections 12.A. and Sections 12.B. for combustible/ non-combustible materials. Refer to Figure 12.10 for non- combustible zone. W ARNING! Risk of Fire! Y ou must maintain clearances. • Use only non-combustible framing material b[...]
-
Page 45
45 E. Combustible Mantel • Refer to the shaded areas of Figure 12.1 1 for the location and dimensions of a combustible mantel. • A combustible mantel may be positioned no lower than 22 in. (508 mm) above the top of the replace opening. • A combustible mantel may have a maximum depth of 12 in. (305 mm). • Combustible trim and materials ca[...]
-
Page 46
46 18 1/2 in. [470 mm] 19 3/4 in. [500 mm] 4 in. [102 mm] 50° angle 39° angle 24 in. [610 mm] BRICK FRONT FLUSH FRONT 24 in. [610 mm] 22 3/8 in. [568 mm] 52-7/8 in. (1343 mm) 42 in. [1067 mm] Note: Grid depicts 1 inch squares. F . Sidewalls/Surrounds • Adjacent combustible sidewalls must be located a minimum of 24 in. (305 mm) from the repla[...]
-
Page 47
47 A. Gas Log/Lighter Provision W ARNING! Fire and/or Asphyxiation Risk! Use with solid wood fuel or decorative gas appliance only . Gas re gener- ates fumes. • DO NOT install unvented gas logs • Damper must be locked fully open when gas logs are installed Firebox Repack insulation knockout Combustible materials Maintain air clearance to com[...]
-
Page 48
48 1 4 Reference Materials A. Fireplace Dimensions 37 1/8 in. (943 mm) 74 ° TYP . 1 1 in. (281 mm) 27 1/2 in. (699 mm) 5 in. (129 mm) 16 1/8 in. (408 mm) 1 1 1/8 in. (282 mm) 6 7/8 in. (175 mm) 52 7/8 in. (1343 mm) 42 in. (1067 mm) 54 in. (1372 mm) 38 in. (965 mm) 70 3/4 in. (1797 mm) 74 1/8 in. (1884 mm) 3 3/4 in. (95 mm) 5 in. (129 mm) 6 7/8 in.[...]
-
Page 49
49 B. Optional Components DFG4042 Series Glass Doors (optional) 20 in. (508 mm) 66 in. (1676 mm) 1/2 in. (13 mm) HX4 Hearth Extension DFS4042 Series Screen Doors (optional) ID6 Insulated Duct UD6 Uninsulated Duct 42 in. (1067 mm) 6 in. (152.4 mm) i.d. 42 in. (1067 mm) 6 in. (152.4 mm) i.d. Heatilator • Birmingham BIR42-B • 4059-681• 1 1/1 1 S[...]
-
Page 50
50 C. Chimney Components The following pictures show only those chimney components which may be safely used with this replace. Heatilator • Birmingham BIR42-B • 4059-681 • 1 1/1 1 Catalog # A B in mm in mm SL1 106 6 152 4-3/4 121 SL1 1 12 12 305 10-3/4 273 SL1 1 18 18 457 16-3/4 425 SL1 136 36 914 34-3/4 883 SL1 148 48 1219 46-3/4 1 187 SL[...]
-
Page 51
51 Heatilator • Birmingham BIR42-B • 4059-681• 1 1/1 1 SL1 130 Offset/Return AS10 Straight Attic Insulation Shield Assembled Diameter: 17 in./432 mm Height: 24 in./610 mm JB577 Chimney Joint Band CB576 Chimney Joint Band 13 in. (330 mm) 2 in. (51 mm) 13 in. (330 mm) A B 17 in. (432 mm) Catalog # A B FS538 0-deg. 17 in. 432 mm FS540 30-deg. 26[...]
-
Page 52
52 26 in. 10 3/4 in. Heatilator • Birmingham BIR42-B • 4059-681 • 1 1/1 1 TR1 1 - Round T ermination Cap TR1 1T - Round T elescoping T ermination Cap ST1 175 - Square T ermination Cap TCT1 175 - T erra Cotta Cap 15-3/4 in. (400 mm) 32-3/8 in. (822 mm) 34-3/8 in . (873 mm) 23 in. (584 mm) 19 in. (483 mm) 15-5/8 in. (397 mm) 9-3/8 in. (238 mm) [...]
-
Page 53
53 Heatilator • Birmingham BIR42-B • 4059-681• 1 1/1 1 DTO134 A B C in 34 20 24 mm 864 508 610 DTO146 in 46 22.7 26 mm 1168 576 660 DTS134 in 34 21.18 24 mm 864 538 610 DTS146 in 46 21.18 26 mm 1168 538 660 B C B A C A DTS134 /DTS146 DTO134 / DT O146 Decorative Caps LDS-BV Decorative Shroud E D A C B CT56 Chase T op 72 in. (1829 mm) 36 in. (9[...]
-
Page 54
54 D. Service Parts IMPORT ANT : THIS IS DA TED INFORMA TION. When requesting service or replacement parts for your appliance please provide model number and serial number . All parts listed in this manual may be ordered from an authorized dealer . Stocked at Depot ITEM DESCRIPTION COMMENTS P ART NUMBER T raditional Refractory MMTB42-B 12 Left Pane[...]
-
Page 55
55 – NOTES – E. Contact Information DO NOT DISCARD THIS MANUAL CAUTION • Important operating and maintenance instructions included. • Leave this manual with party responsible for use and operation. • Read, understand and follow these instructions for safe installation and operation. DO NOT DISCARD Heatilator • Birmingham BIR42-B • 405[...]