Go to page of
Similar user manuals
-
Gas Heater
Heat & Glo LifeStyle 8000TV-OAK
46 pages 2.56 mb -
Gas Heater
Heat & Glo LifeStyle 350TRSILP-AUF
80 pages 12.12 mb -
Gas Heater
Heat & Glo LifeStyle 350TRSI-AUF
80 pages 12.12 mb -
Gas Heater
Heat & Glo LifeStyle 6000XLSB
25 pages 0.94 mb -
Gas Heater
Heat & Glo LifeStyle 7000XLS
25 pages 0.94 mb -
Gas Heater
Heat & Glo LifeStyle CERONA-36
62 pages 3.71 mb -
Gas Heater
Heat & Glo LifeStyle 8000TVLP-OAKIPI
46 pages 2.56 mb -
Gas Heater
Heat & Glo LifeStyle TIARAP-BR
56 pages 5.15 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Heat & Glo LifeStyle 8000TVLP-OAKIPI, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Heat & Glo LifeStyle 8000TVLP-OAKIPI one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Heat & Glo LifeStyle 8000TVLP-OAKIPI. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Heat & Glo LifeStyle 8000TVLP-OAKIPI should contain:
- informations concerning technical data of Heat & Glo LifeStyle 8000TVLP-OAKIPI
- name of the manufacturer and a year of construction of the Heat & Glo LifeStyle 8000TVLP-OAKIPI item
- rules of operation, control and maintenance of the Heat & Glo LifeStyle 8000TVLP-OAKIPI item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Heat & Glo LifeStyle 8000TVLP-OAKIPI alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Heat & Glo LifeStyle 8000TVLP-OAKIPI, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Heat & Glo LifeStyle service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Heat & Glo LifeStyle 8000TVLP-OAKIPI.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Heat & Glo LifeStyle 8000TVLP-OAKIPI item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
1 Heat & Glo • 8000TV -OAK, 8000TV -OAK-IPI, 8000TVLP-OAKIPI • 2058-900 Rev . L • 08/08 Models: 8000TV -OAK 8000TV -OAK-IPI 8000TVLP-OAKIPI In the Commonwealth of Massachusetts: • installation must be performed by a licensed plumber or gas fi tter; • a CO detector shall be installed in the room where the appliance is installed. • D[...]
-
Page 2
2 Heat & Glo • 8000TV -OAK, 8000TV -OAK-IPI, 8000TVLP-OAKIPI • 2058-900 Rev . L • 08/08 Congratulations Listing Label Information/Location Model Name: ___________________________________________ Date purchased/installed: __________________ Serial Number: __________________________________________ Location on appliance: ___________________[...]
-
Page 3
3 Heat & Glo • 8000TV -OAK, 8000TV -OAK-IPI, 8000TVLP-OAKIPI • 2058-900 Rev . L • 08/08 Î = Contains updated information. T able of Contents 1 Listing and Code Approvals A. Appliance Certi fi cation . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 B. Glass Speci fi cations . . . . . . . . . . . . . . . . . . . . . . . . . . . [...]
-
Page 4
4 Heat & Glo • 8000TV -OAK, 8000TV -OAK-IPI, 8000TVLP-OAKIPI • 2058-900 Rev . L • 08/08 MODELS: 8000TV-OAK, 8000TV-OAK-IPI, 8000TVLP-OAKIPI LABORATORY: Underwriters Laboratories, Inc. (UL) TYPE: B-Vent Decorative STANDARD: ANSI Z21.50-2002 • CGA2.2 B. Glass Speci fi cations Hearth & Home T echnologies appliances manufactured with t[...]
-
Page 5
5 Heat & Glo • 8000TV -OAK, 8000TV -OAK-IPI, 8000TVLP-OAKIPI • 2058-900 Rev . L • 08/08 E. Non-Combustible Materials Speci fi cation Material which will not ignite and burn. Such materials are those consisting entirely of steel, iron, brick, tile, concrete, slate, glass or plasters, or any combination thereof. Materials that are reported[...]
-
Page 6
6 Heat & Glo • 8000TV -OAK, 8000TV -OAK-IPI, 8000TVLP-OAKIPI • 2058-900 Rev . L • 08/08 A. Design and Installation Considerations Heat & Glo B-type vent gas appliances are designed to operate with all exhaust gases expelled to the outside of the building, and combustion air pulled from the room. When planning an appliance installation[...]
-
Page 7
7 Heat & Glo • 8000TV -OAK, 8000TV -OAK-IPI, 8000TVLP-OAKIPI • 2058-900 Rev . L • 08/08 Recommended Location Marginal Location Location Not Recommended Recommended Location Location NOT Recommended Multi-level Roofs Windward Leeward Figure 2.1 B. Negative Pressure Draft is the pressure difference needed to vent fi replaces successfully .[...]
-
Page 8
8 Heat & Glo • 8000TV -OAK, 8000TV -OAK-IPI, 8000TVLP-OAKIPI • 2058-900 Rev . L • 08/08 D. Inspect Appliance and Components C. T ools and Supplies Needed Before beginning the installation be sure that the following tools and building supplies are available. Reciprocating saw Framing material Pliers Hi temp caulking material Hammer Gloves [...]
-
Page 9
9 Heat & Glo • 8000TV -OAK, 8000TV -OAK-IPI, 8000TVLP-OAKIPI • 2058-900 Rev . L • 08/08 AB C D E F G Inches 55-7/8 1/2 79 49 Min. 1 37-3/8 22 Millimeters 1419 13 2007 1245 25 949 559 Figure 3.1 Appliance Locations In addition to these framing dimensions, also reference the following sections: • Clearances and Mantel Projections (Section[...]
-
Page 10
10 Heat & Glo • 8000TV -OAK, 8000TV -OAK-IPI, 8000TVLP-OAKIPI • 2058-900 Rev . L • 08/08 CLEARANCES TO COMBUSTIBLES AB C D E F G H I J Rough Opening (V ent Pipe) Rough Opening (Height) Rough Opening (Depth) Rough Opening (Width) Clearance to Ceiling Combustible Floor Combustible Flooring Behind Appliance Sides of Appliance Front of Applia[...]
-
Page 11
11 Heat & Glo • 8000TV -OAK, 8000TV -OAK-IPI, 8000TVLP-OAKIPI • 2058-900 Rev . L • 08/08 D. Mantel Projections 1/2 INCH (13 mm) 32 IN. (813 mm) TOP OF HOOD 12 IN. (305 mm) NON-COMBUSTIBLE MA TERIAL ONL Y 13 IN. (330 mm) CEILING TOP FRONT EDGE OF FIREPLACE Note: Clearance from opening to perpendicular wall. 1 in. MIN. 3 in. MIN. 3 ft. MAX.[...]
-
Page 12
12 Heat & Glo • 8000TV -OAK, 8000TV -OAK-IPI, 8000TVLP-OAKIPI • 2058-900 Rev . L • 08/08 Roof Pitch H (Min.) Ft. Flat to 6/12...........................................................1.0* Over 6/12 to 7/12 .................................................1.25* Over 7/12 to 8/12 .................................................1.5* Over 8[...]
-
Page 13
13 Heat & Glo • 8000TV -OAK, 8000TV -OAK-IPI, 8000TVLP-OAKIPI • 2058-900 Rev . L • 08/08 MET AL PLUMBER’S STRAP 9 FEET MINIMUM VENT SUPPORTS ARE PER VENT MANUF ACTURER’S SPECIFICA TIONS MINIMUM CLEARANCES ARE PER VENT MANUF ACTURER’S SPECIFICA TIONS MET AL PLUMBERS' STRAP MAXIMUM HORIZONTAL RUN IS 50% OF VERTICAL. HORIZONTAL RU[...]
-
Page 14
14 Heat & Glo • 8000TV -OAK, 8000TV -OAK-IPI, 8000TVLP-OAKIPI • 2058-900 Rev . L • 08/08 Fire Risk. Explosion Risk. Insulation and other combustibles must not infringe on clearances. • AL WA YS maintain speci fi ed clearances around venting and fi restop systems. • Install fi restops as speci fi ed. Failure to keep insulation or o[...]
-
Page 15
15 Heat & Glo • 8000TV -OAK, 8000TV -OAK-IPI, 8000TVLP-OAKIPI • 2058-900 Rev . L • 08/08 Note: This product MUST terminate vertically . Follow vent pipe manufacturer ’s instructions for all clear- ances around pipe. B. V ertical Penetration Framing Use B-vent manufacturer ’s fi restops to provide adequate clearances. Fire Hazard Keep[...]
-
Page 16
16 Heat & Glo • 8000TV -OAK, 8000TV -OAK-IPI, 8000TVLP-OAKIPI • 2058-900 Rev . L • 08/08 A. Installing Outside Air Kit Damper Assembly Asphyxiation Risk. Fire Risk. Do NOT draw outside combustion air from: • W all, fl oor or ceiling cavity . • Enclosed space such as an attic or garage. • Close proximity to exhaust vents or chimneys[...]
-
Page 17
17 Heat & Glo • 8000TV -OAK, 8000TV -OAK-IPI, 8000TVLP-OAKIPI • 2058-900 Rev . L • 08/08 Figure 7.3 Proper Positioning, Leveling and Securing of a Appliance NAILING T ABS (BOTH SIDES) Fire Risk. • AL WA YS maintain speci fi ed clearances around the appliance. • Do NOT notch into the framing around the appliance spacers. Failure to ke[...]
-
Page 18
18 Heat & Glo • 8000TV -OAK, 8000TV -OAK-IPI, 8000TVLP-OAKIPI • 2058-900 Rev . L • 08/08 A. Assembly of V ent Sections This appliance requires a 6-inch B-vent double-wall pipe. Follow the pipe manufacturer ’ s installation guidelines when installing the unit. This will ensure proper operation and prevent safety hazards. Fire Risk Exhaus[...]
-
Page 19
19 Heat & Glo • 8000TV -OAK, 8000TV -OAK-IPI, 8000TVLP-OAKIPI • 2058-900 Rev . L • 08/08 Note: Have the gas supply line installe d in acco rdance w i t h l o c a l b u i l d i n g c o d e s , i f a n y . I f n o t , f o l l o w A N S I 223. 1 . Installation shou ld b e done b y a quali fi ed installer approv ed and/or licensed as requ ir[...]
-
Page 20
20 Heat & Glo • 8000TV -OAK, 8000TV -OAK-IPI, 8000TVLP-OAKIPI • 2058-900 Rev . L • 08/08 Fire hazard. Do NOT change the valve settings. • This valve has been preset at the factory . • Changing valve settings may result in fi re hazard or bodily injury . HIGH AL TITUDE INST ALLA TIONS U.L. Listed gas appliances are tested and approved[...]
-
Page 21
21 Heat & Glo • 8000TV -OAK, 8000TV -OAK-IPI, 8000TVLP-OAKIPI • 2058-900 Rev . L • 08/08 • This appliance MUST be used with a wall switch or a remote control. • This unit is not for use with thermostats. • Keep wire lengths short as possible by removing any excess wire length. • Low voltage and 1 10 V AC voltage cannot be shared w[...]
-
Page 22
22 Heat & Glo • 8000TV -OAK, 8000TV -OAK-IPI, 8000TVLP-OAKIPI • 2058-900 Rev . L • 08/08 C. Intelli fi re Ignition System Wiring This appliance requires a 1 10 V AC supply to the appliance junction box for operation. A wiring diagram is shown in Figure 10.2. This appliance is equipped with an Intelli fi re control valve which operates o[...]
-
Page 23
23 Heat & Glo • 8000TV -OAK, 8000TV -OAK-IPI, 8000TVLP-OAKIPI • 2058-900 Rev . L • 08/08 D. Standing Pilot Ignition System Wiring This s tanding pilot ignition system wiring does not require a 110 VAC supply to operate. Figure 10.3 Standing Pilot Ignition Wiring Diagram Figure 10.2 Intelli fi re Pilot Ignition (IPI) W iring Diagram NOTE:[...]
-
Page 24
24 Heat & Glo • 8000TV -OAK, 8000TV -OAK-IPI, 8000TVLP-OAKIPI • 2058-900 Rev . L • 08/08 If the box is being wired from the appliance: • Remove the screw attaching the junction box to the outer shell, rotate the junction box inward to disengage it from the outer shell (see Figure 10.4). • Pull the electrical wires from outside the app[...]
-
Page 25
25 Heat & Glo • 8000TV -OAK, 8000TV -OAK-IPI, 8000TVLP-OAKIPI • 2058-900 Rev . L • 08/08 Fire Risk Explosion Risk • Facing and/or finishing materials must never overhang into the glass opening. • Overhanging materials may ignite. • May interfere with proper operation of glass assembly . Figure 1 1.3 Noncombustible Facing Diagram A. [...]
-
Page 26
26 Heat & Glo • 8000TV -OAK, 8000TV -OAK-IPI, 8000TVLP-OAKIPI • 2058-900 Rev . L • 08/08 Ember material is shipped with this gas appliance. T o place the ember material: • When placing Glowing Embers ® onto the burner care should be taken so that the ports are not covered. Place the dime-size ember pieces about 1/2 inch apart near port[...]
-
Page 27
27 Heat & Glo • 8000TV -OAK, 8000TV -OAK-IPI, 8000TVLP-OAKIPI • 2058-900 Rev . L • 08/08 Log Assembly: LOGS-8OAK F . Positioning the Logs If the gas logs have been factory installed they should not need to be positioned. If the logs have been packaged separately , refer to the following instructions. CAUTION: Carefully remove the logs fro[...]
-
Page 28
28 Heat & Glo • 8000TV -OAK, 8000TV -OAK-IPI, 8000TVLP-OAKIPI • 2058-900 Rev . L • 08/08 STEP 5: (SR V2057-723): Mate the top of log 4 with the right metal tab on log 3. The bottom of log 4 should touch the inside face of the right grate tine. 2 3 1 2 3 1 5 4 2 3 5 6 STEP 7: (SR V2057-725): Place log 6 on log 2 as shown. The left end of l[...]
-
Page 29
29 Heat & Glo • 8000TV -OAK, 8000TV -OAK-IPI, 8000TVLP-OAKIPI • 2058-900 Rev . L • 08/08 H. Screen Mesh The screen mesh is a protective barrier and must be at- tached. I. Grilles and T rim Install optional marble and brass trim surround kits as de- sired. Marble, brass, brick, tile, or other non-combustible materials can be used to cover [...]
-
Page 30
30 Heat & Glo • 8000TV -OAK, 8000TV -OAK-IPI, 8000TVLP-OAKIPI • 2058-900 Rev . L • 08/08 Before operating this appliance have a qualified technician: • Remove all shipping materials from inside and/or underneath the fi rebox. • Review proper placement of logs, rockwool, lava rock, and vermiculite. • Check the wiring. • Check the [...]
-
Page 31
31 Heat & Glo • 8000TV -OAK, 8000TV -OAK-IPI, 8000TVLP-OAKIPI • 2058-900 Rev . L • 08/08 C. Lighting Appliance 1. T urn off all electric power to the appliance. 2. This appliance is equipped with an ignition device which automatically lights the burner . Do not try to light the burner by hand. 3. Wait fi ve (5) minutes to clear out any g[...]
-
Page 32
32 Heat & Glo • 8000TV -OAK, 8000TV -OAK-IPI, 8000TVLP-OAKIPI • 2058-900 Rev . L • 08/08 Standing Pilot Ignition 1. T urn off all electric power to the appliance if service is to be performed. 2. Open control access panel. 3. Move switch to “OFF” position. 4. Push in gas control knob slightly and turn clock- wise to OFF”. Do not for[...]
-
Page 33
33 Heat & Glo • 8000TV -OAK, 8000TV -OAK-IPI, 8000TVLP-OAKIPI • 2058-900 Rev . L • 08/08 Initial Break-in Procedure When you light the appliance, you may notice that it pro- duces heat which does have an associated odor or smell. If you feel this odor is excessive it may require the initial three to four hour continuous burn on high follo[...]
-
Page 34
34 Heat & Glo • 8000TV -OAK, 8000TV -OAK-IPI, 8000TVLP-OAKIPI • 2058-900 Rev . L • 08/08 A. Standing Pilot Ignition System 1 4 14 T roubleshooting With proper installation, operation, and maintenance your gas appliance will provide years of trouble-free service. If you do experience a problem, this troubleshooting guide will assist a qual[...]
-
Page 35
35 Heat & Glo • 8000TV -OAK, 8000TV -OAK-IPI, 8000TVLP-OAKIPI • 2058-900 Rev . L • 08/08 T roubleshooting (continued) Symptom Possible Cause Corrective Action 3. Continued c. Defective valve. T urn the valve knob to the ON position. Place the ON/OFF switch in the ON position. Check the millivolt meter a the thermopile terminals. The milli[...]
-
Page 36
36 Heat & Glo • 8000TV -OAK, 8000TV -OAK-IPI, 8000TVLP-OAKIPI • 2058-900 Rev . L • 08/08 B. Intelli fi re Ignition System Sympton Possible Cause Corrective Action 1. The ignitor/module makes noise, but no spark. a. Incorrect wiring. V erify “S” wire (white) for sensor and “I” wire (orange) for ignitor are connected to correct ter[...]
-
Page 37
37 Heat & Glo • 8000TV -OAK, 8000TV -OAK-IPI, 8000TVLP-OAKIPI • 2058-900 Rev . L • 08/08 Intelli fi re Ignition System - (continued) Symptom Possible Cause Corrective Action 3. (Continued) Pilot lights but continues to spark, and main burner will not ignite. (If the pilot contin- ues to spark after the pilot fl ame has been lit, fl ame[...]
-
Page 38
38 Heat & Glo • 8000TV -OAK, 8000TV -OAK-IPI, 8000TVLP-OAKIPI • 2058-900 Rev . L • 08/08 1 5 15 Maintaining and Ser vicing Appliance Although the frequency of appliance servicing and maintenance will depend on use and the type of installation, a quali fi ed service technician should perform an appliance checkup at the beginning of each h[...]
-
Page 39
39 Heat & Glo • 8000TV -OAK, 8000TV -OAK-IPI, 8000TVLP-OAKIPI • 2058-900 Rev . L • 08/08 Inspect Maintenance T asks Doors, Surrounds and Fronts 1. Assess condition of screen and replace as necessary . Recommend addition of screen if one is not present. 2. Inspect for scratches, dents or other damage and repair as necessary . 3. V erify no[...]
-
Page 40
40 Heat & Glo • 8000TV -OAK, 8000TV -OAK-IPI, 8000TVLP-OAKIPI • 2058-900 Rev . L • 08/08 1 6 16 R eference Materials ELECTRICAL ACCESS A B C D E F G I GAS LINE ACCESS J K L M O P Q R H N A. Appliance Dimension Diagram Dimensions are actual appliance dimensions. Use for reference only. Fo r framing dimensions and clearances refer to Sectio[...]
-
Page 41
41 Heat & Glo • 8000TV -OAK, 8000TV -OAK-IPI, 8000TVLP-OAKIPI • 2058-900 Rev . L • 08/08 Service Parts Service Parts Diagram 8000TV-OAK, 8000TV-OAK-IPI Beginning Manufacturing Date: Feb. 2005 Ending Manufacturing Date: ______ 8 9 10 11 12 13 7 Log Set Assembly Part number list on following page. 6 3 5 1 4 2[...]
-
Page 42
42 Heat & Glo • 8000TV -OAK, 8000TV -OAK-IPI, 8000TVLP-OAKIPI • 2058-900 Rev . L • 08/08 IMPORT ANT : THIS IS DA TED INFORMA TION, When requesting service or replacement parts for your appliance please provide model number and serial number . All parts listed in this manual may be ordered from an authorized dealer . Stocked at Depot ITEM [...]
-
Page 43
43 Heat & Glo • 8000TV -OAK, 8000TV -OAK-IPI, 8000TVLP-OAKIPI • 2058-900 Rev . L • 08/08 Service Parts V alve Assembly Parts List 8000TV-OAK-IPI Beginning Manufacturing Date: Feb. 2005 Ending Manufacturing Date: ______ 6 7 8 1 5 9 3 2 4 IPI V alve Assembly IMPORT ANT : THIS IS DA TED INFORMA TION, When requesting service or replacement pa[...]
-
Page 44
44 Heat & Glo • 8000TV -OAK, 8000TV -OAK-IPI, 8000TVLP-OAKIPI • 2058-900 Rev . L • 08/08 Service Parts V alve Assembly Parts List 8000TV -OAK Beginning Manufacturing Date: Feb. 2005 Ending Manufacturing Date: ______ Standing Pilot V alve Assembly 1 2 3 4 5 6 7 8 9 IMPORT ANT : THIS IS DA TED INFORMA TION, When requesting service or replac[...]
-
Page 45
45 Heat & Glo • 8000TV -OAK, 8000TV -OAK-IPI, 8000TVLP-OAKIPI • 2058-900 Rev . L • 08/08 © 2007 Hearth & Home T echnologies Inc. LIMITED LIFETIME W ARRANTY HEA T & GLO GAS APPLIANCE PRODUCTS 060-981E 10/07 C. Limited Lifetime W arranty BASIC ONE-YEAR W ARRANTY . HEA T & GLO, a brand of HEARTH & HOME TECHNOLOGIES INC., loc[...]
-
Page 46
46 Heat & Glo • 8000TV -OAK, 8000TV -OAK-IPI, 8000TVLP-OAKIPI • 2058-900 Rev . L • 08/08 Heat & Glo, a brand of Hearth & Home T echnologies Inc. 20802 Kensington Boulevard, Lakeville, MN 55044 www .heatnglo.com D. Contact Information Please contact your Heat & Glo dealer with any questions or concerns. For the location of your[...]