Heat & Glo LifeStyle BE-41IPIC manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Heat & Glo LifeStyle BE-41IPIC, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Heat & Glo LifeStyle BE-41IPIC one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Heat & Glo LifeStyle BE-41IPIC. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Heat & Glo LifeStyle BE-41IPIC should contain:
- informations concerning technical data of Heat & Glo LifeStyle BE-41IPIC
- name of the manufacturer and a year of construction of the Heat & Glo LifeStyle BE-41IPIC item
- rules of operation, control and maintenance of the Heat & Glo LifeStyle BE-41IPIC item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Heat & Glo LifeStyle BE-41IPIC alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Heat & Glo LifeStyle BE-41IPIC, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Heat & Glo LifeStyle service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Heat & Glo LifeStyle BE-41IPIC.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Heat & Glo LifeStyle BE-41IPIC item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Heat & Glo • BE-41C / LP , BE-41IPIC / LP • 2105-900 Rev . P • 6/09 1 Models: BE-41C BE-41LPC BE-41IPIC BE-41IPILPC • DO NOT store or use gasoline or other fl am- mable vapors and liquids in the vicinity of this or any other appliance. • What to do if you smell gas - DO NOT try to light any appliance. - DO NOT touch any electrical sw[...]

  • Page 2

    Heat & Glo • BE-41C / LP , BE-41IPIC / LP • 2105-900 Rev . P • 6/09 2 Listing Label Information/Location Model Name: ___________________________________________ Date purchased/installed: __________________ Serial Number: __________________________________________ Location on fi replace: _____________________ Dealership purchased from: __[...]

  • Page 3

    Heat & Glo • BE-41C / LP , BE-41IPIC / LP • 2105-900 Rev . P • 6/09 3 Safety Alert Key: • DANGER! Indicates a hazardous situation which, if not avoided will result in death or serious injury . • W ARNING! Indicates a hazardous situation which, if not avoided could result in death or serious injury . • CAUTION! Indicates a hazardous [...]

  • Page 4

    Heat & Glo • BE-41C / LP , BE-41IPIC / LP • 2105-900 Rev . P • 6/09 4 Î = Contains updated information. 13 Finishing A. Mantel and Wall Projections . . . . . . . . . . . . . . . . . . . . . . . 51 B. Facing Material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51 C. Doors . . . . . . . . . . . . . . . . . . . . . . .[...]

  • Page 5

    Heat & Glo • BE-41C / LP , BE-41IPIC / LP • 2105-900 Rev . P • 6/09 5 B. Limited Lifetime W arranty Î[...]

  • Page 6

    Heat & Glo • BE-41C / LP , BE-41IPIC / LP • 2105-900 Rev . P • 6/09 6 B. Limited Lifetime W arranty (continued) Î[...]

  • Page 7

    Heat & Glo • BE-41C / LP , BE-41IPIC / LP • 2105-900 Rev . P • 6/09 7 B. T empered Glass Speci fi cations Hearth & Home T echnologies appliances manufactured with tempered glass may be installed in hazardous loca- tions such as bathtub enclosures as de fi ned by the Con- sumer Product Safety Commission (CPSC). The tempered glass has[...]

  • Page 8

    Heat & Glo • BE-41C / LP , BE-41IPIC / LP • 2105-900 Rev . P • 6/09 8 H. Requirements for the Commonwealth of Massachusetts For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, including those owned or operated by the Commonwealth a[...]

  • Page 9

    Heat & Glo • BE-41C / LP , BE-41IPIC / LP • 2105-900 Rev . P • 6/09 9 Figure 2.1 General Operating Parts B. Y our Fireplace W ARNING! DO NOT operate fi replace before read- ing and understanding operating instructions. Failure to operate fi replace according to operating instructions could cause fi re or injury . DECORA TIVE DOORS (NOT[...]

  • Page 10

    Heat & Glo • BE-41C / LP , BE-41IPIC / LP • 2105-900 Rev . P • 6/09 10 D. Clear Space W ARNING! DO NOT place combustible objects in front of the fi replace or block louvers. High temperatures may start a fi re. See Figure 2.2. Avoid placing candles and other heat-sensitive objects on mantel or hearth. Heat may damage these objects. Figu[...]

  • Page 11

    Heat & Glo • BE-41C / LP , BE-41IPIC / LP • 2105-900 Rev . P • 6/09 1 1 I. Lighting Instructions (IPI) The IPI system may be operated with two D-cell batteries. When using batteries, unplug the transformer . T o prolong battery life, remove them when using the transformer . 1. Turn off all electric power to the appliance. 2. This applianc[...]

  • Page 12

    Heat & Glo • BE-41C / LP , BE-41IPIC / LP • 2105-900 Rev . P • 6/09 12 J. Lighting Instructions (Standing Pilot) 1. Turn of f all electric power to the appliance if ser- vice is to be performed. 2. Open control access panel. 3. Move switch to “OFF” position. 4. Push in gas control knob slightly and turn clock- wise to OFF”. DO NOT f[...]

  • Page 13

    Heat & Glo • BE-41C / LP , BE-41IPIC / LP • 2105-900 Rev . P • 6/09 13 Initial Break-in Procedure • The fireplace should be run three to four hours continuously on high. • T urn the fi replace off and allow it to completely cool. • Remove fi xed glass assembly . See Section 14.G. • Clean fi xed glass assembly . See Section 3. ?[...]

  • Page 14

    Heat & Glo • BE-41C / LP , BE-41IPIC / LP • 2105-900 Rev . P • 6/09 14 Glass Cleaning Frequency: Seasonally By: Homeowner T ools Needed : Protective gloves, glass cleaner , drop cloth and a stable work surface. CAUTION! Handle fi xed glass assembly with care. Glass is breakable. • Avoid striking, scratching or slamming glass • Avoid [...]

  • Page 15

    Heat & Glo • BE-41C / LP , BE-41IPIC / LP • 2105-900 Rev . P • 6/09 15 V enting Frequency: Seasonally By: Homeowner T ools needed: Protective gloves and safety glasses. • Inspect venting and termination cap for blockage or obstruction such plants, bird nests, leaves, snow , debris, etc. • V erify termination cap clearance to subsequen[...]

  • Page 16

    Heat & Glo • BE-41C / LP , BE-41IPIC / LP • 2105-900 Rev . P • 6/09 16 (Either cobrahead or SIT) Figure 3.1 IPI Pilot Flame Patterns Figure 3.2 Standing Pilot Flame Patterns[...]

  • Page 17

    Heat & Glo • BE-41C / LP , BE-41IPIC / LP • 2105-900 Rev . P • 6/09 17 A. T ypical Appliance System NOTICE: Illustrations and photos re fl ect typical installations and are for design purposes only . Illustrations/diagrams are not drawn to scale. Actual product may vary from pictures in manual Figure 4.1 T ypical System CEILING FIRESTOP [...]

  • Page 18

    Heat & Glo • BE-41C / LP , BE-41IPIC / LP • 2105-900 Rev . P • 6/09 18 B. Design and Installation Considerations Heat & Glo direct vent gas appliances are designed to operate with all combustion air siphoned from outside of the building and all exhaust gases expelled to the outside. No additional outside air source is required. Instal[...]

  • Page 19

    Heat & Glo • BE-41C / LP , BE-41IPIC / LP • 2105-900 Rev . P • 6/09 19 5 5 F raming and Clearances A. Selecting Appliance Location When selecting a location for the appliance it is important to consider the required clearances to walls (see Figure 5.1). W ARNING! Risk of Fire or Burns! Provide adequate clearance around air openings and fo[...]

  • Page 20

    Heat & Glo • BE-41C / LP , BE-41IPIC / LP • 2105-900 Rev . P • 6/09 20 B. Constructing the Appliance Chase A chase is a vertical box-like structure built to enclose the gas appliance and/or its vent system. In cooler climates the vent should be enclosed inside the chase. NOTICE: T reatment of ceiling fi restops and wall shield fi restop[...]

  • Page 21

    Heat & Glo • BE-41C / LP , BE-41IPIC / LP • 2105-900 Rev . P • 6/09 21 D. Mantel and W all Projections W ARNING! Risk of Fire! Comply with all minimum clear- ances as speci fi ed. Framing or fi nishing material closer than the minimums listed must be constructed entirely of noncom- bustible materials (i.e., steel studs, concrete board, [...]

  • Page 22

    Heat & Glo • BE-41C / LP , BE-41IPIC / LP • 2105-900 Rev . P • 6/09 22 A. V ent T ermination Minimum Clearances Roof Pitch H (Min.) Ft. Flat to 6/12...........................................................1.0* Over 6/12 to 7/12 .................................................1.25* Over 7/12 to 8/12 .....................................[...]

  • Page 23

    Heat & Glo • BE-41C / LP , BE-41IPIC / LP • 2105-900 Rev . P • 6/09 23 O N P R Q V = VENT TERMINAL X = AIR SUPPL Y INLET = AREA WHERE TERMINAL IS NOT PERMITTED Figure 6.3 Minimum Clearances for T ermination A = 12 inches................. clearances above grade, ver anda, porch, deck or balcony B = 12 inches................. clearances to [...]

  • Page 24

    Heat & Glo • BE-41C / LP , BE-41IPIC / LP • 2105-900 Rev . P • 6/09 24 A. Approved Pipe This appliance is approved for use with Hearth & Home T echnologies DVP or SLP venting systems. Refer to Sec- tion 16B for vent component information. DO NOT mix pipe, fi ttings or joining methods from differ- ent manufacturers. The pipe is tested[...]

  • Page 25

    Heat & Glo • BE-41C / LP , BE-41IPIC / LP • 2105-900 Rev . P • 6/09 25 INST ALLED HORIZONT ALL Y H 1 H 2 V 1 H 1 V 1 Figure 7.3 Figure 7.4 T op V ent - Horizontal T ermination T op V ent - Horizontal T ermination One Elbow T wo Elbows Note: For corner installations: A 6 inch (152 mm) section of straight pipe may need to be attached to the[...]

  • Page 26

    Heat & Glo • BE-41C / LP , BE-41IPIC / LP • 2105-900 Rev . P • 6/09 26 Figure 7.5 T op V ent - Horizontal T ermination - (continued) Three Elbows H 2 H 1 V 2 V 1 V 1 Min. H 1 Max. V 2 Min. H 2 Max. Elbow only 2 ft. 610 mm 0 in. 0 mm 1 ft. 305 mm 6 in. 152 mm 3 ft 914 mm 6 in. 152 mm 2 ft. 610 mm 1 ft. 305 mm 6 ft. 1.8 m 1 ft. 305 mm 6 ft.[...]

  • Page 27

    Heat & Glo • BE-41C / LP , BE-41IPIC / LP • 2105-900 Rev . P • 6/09 27 EXHAUST SHIELD FLUE RESTRICTOR T op V ent - V ertical T ermination No Elbow Figure 7.6 Note: If installing a vertical vent/ termination off the top of the ap- pliance, the fl ue restrictor should be used. V 1 V 1 = 40 ft. Max. (12.4 m) V 1 = 3 ft. Min. (914 mm) Flue R[...]

  • Page 28

    Heat & Glo • BE-41C / LP , BE-41IPIC / LP • 2105-900 Rev . P • 6/09 28 H 1 V 1 V 2 T op V ent - V ertical T ermination (continued) Figure 7.1 1 T wo Elbows Figure 7.10 4. Center the Flue Restrictor on vent and secure in place by using two self-tapping screws (see Figure 7.10). 5. Reinstall the Exhaust Shield. 3. Match the amount of vertic[...]

  • Page 29

    Heat & Glo • BE-41C / LP , BE-41IPIC / LP • 2105-900 Rev . P • 6/09 29 Figure 7.12 T op V ent - V ertical T ermination - (continued) Three Elbows INST ALLED HORIZONT ALL Y H 1 H 2 V 1 V 2 V 1 H 1 + H 2 V 2 V 1 + V 2 Minimum H 1 + H 2 Maximum Elbow only 1 ft. 305 mm * * * 1 ft. 305 mm 6 in. 152 mm 2 ft. 610 mm * * * 2 ft. 610 mm 1 ft. 305 [...]

  • Page 30

    Heat & Glo • BE-41C / LP , BE-41IPIC / LP • 2105-900 Rev . P • 6/09 30 Rear V ent - Horizontal T ermination Figure 7.13 Figure 7.14 No Elbow One 45º Elbow H 1 H 1 H 1 = 16 in. (406 mm) Maximum Do not use a 45º elbow in corner installations. Use two 90º elbows instead.[...]

  • Page 31

    Heat & Glo • BE-41C / LP , BE-41IPIC / LP • 2105-900 Rev . P • 6/09 31 INSTALLED HORIZONTALLY H 3 H 1 H 2 V 1 Rear V ent - Horizontal T ermination - (continued) T wo Elbows Figure 7.15 Figure 7.16 Three Elbows H 1 H 2 V 1 H 1 Maximum V 1 Minimum H 2 H 1 + H 2 Maximum 1 ft. 305 mm Back to Back 90º Elbows 1 ft. 305 mm 2 ft. 610 mm 2 ft. 61[...]

  • Page 32

    Heat & Glo • BE-41C / LP , BE-41IPIC / LP • 2105-900 Rev . P • 6/09 32 Rear V ent - V ertical T ermination One Elbow Figure 7.17 T wo Elbows Figure 7.18 H 1 V 1 INST ALLED HORIZONT ALL Y H 1 H 2 V 2 V 1 Minimum H 1 Maximum 6 in. 152 mm 2 ft. 610 mm 1 ft. 305 mm 3 ft. 914 mm 2 ft. 610 mm 5 ft. 1.5 m 3 ft. 914 mm 7 ft. 2.1 m 4 ft. 1.2 m 8 f[...]

  • Page 33

    Heat & Glo • BE-41C / LP , BE-41IPIC / LP • 2105-900 Rev . P • 6/09 33 Rear V ent - V ertical T ermination - (continued) Three Elbows Figure 7.19 Three Elbows Figure 7.20 INST ALLED HORIZONT ALL Y H 3 H 1 H 2 V 1 V 2 V 1 H 2 H 1 H 1 H 2 H 3 V 1 Minimum H 1 + H 2 + H 3 Maximum *** 8 ft. 2.4 m 6 ft. 1.8 m *** 9 ft. 2.7 m 7 ft. 2.1 m *** 10 [...]

  • Page 34

    Heat & Glo • BE-41C / LP , BE-41IPIC / LP • 2105-900 Rev . P • 6/09 34 A* B* 10 in. 12 in. C D 10 in. 12 in. A. Pipe Clearances to Combustibles W ARNING! Risk of Fire! Maintain air space clearance to vent. DO NOT pack insulation or other combustibles: • Between ceiling fi restops • Between wall shield fi restops • Around vent syst[...]

  • Page 35

    Heat & Glo • BE-41C / LP , BE-41IPIC / LP • 2105-900 Rev . P • 6/09 35 C. Install the Ceiling Firestop A ceiling fi restop MUST be used between fl oors and attics. • DVP pipe only - Frame an opening 10 in. by 10 in. (254 mm by 254 mm) whenever the vent penetrates a ceiling/ fl oor (see Figure 8.3). • SLP pipe only - Frame opening 9[...]

  • Page 36

    Heat & Glo • BE-41C / LP , BE-41IPIC / LP • 2105-900 Rev . P • 6/09 36 D. Install Attic Insulation Shield W ARNING! Fire Risk. DO NOT allow loose materials or insulation to touch vent. Hearth & Home T echnologies Inc. requires the use of an attic shield. The National Fuel Gas Code ANSI Z223.1 and NFPA 54 requires an attic shield const[...]

  • Page 37

    Heat & Glo • BE-41C / LP , BE-41IPIC / LP • 2105-900 Rev . P • 6/09 37 CAUTION! Risk of Cuts, Abrasions or Flying Debris. Wear protective gloves and safety glasses during instal- lation. Sheet metal edges are sharp. NOTICE: Once appliance is set up for top or rear venting, it CANNOT be changed at a later time. A. T op V ent 9 9 Appliance [...]

  • Page 38

    Heat & Glo • BE-41C / LP , BE-41IPIC / LP • 2105-900 Rev . P • 6/09 38 B. Rear V ent CAUTION! Risk of Cuts, Abrasions or Flying Debris. Wear protective gloves and safety glasses during instal- lation. Sheet metal edges are sharp. NOTICE: Once appliance is set up for top or rear venting, it CANNOT be changed at a later time. Figure 9.6 T o[...]

  • Page 39

    Heat & Glo • BE-41C / LP , BE-41IPIC / LP • 2105-900 Rev . P • 6/09 39 Figure 9.12 Non-combustible Board C. Installing the Non-combustible Board The factory supplied non-combustible board spans the distance from the top of the fi replace to the center of the framing header . This board must be used. See Figure 9.12. HEADER HEADER D. Secu[...]

  • Page 40

    Heat & Glo • BE-41C / LP , BE-41IPIC / LP • 2105-900 Rev . P • 6/09 40 1 0 10 Inst all ing V ent Pipe (D VP and SLP P ipe ) A. Assemble V ent Sections (DVP Pipe Only) Attach V ent to the Firebox Assembly Note: Th e end of the pipe sec tions with t he lanced ta bs will face toward the applianc e. Attach the fi rst pipe section to the star[...]

  • Page 41

    Heat & Glo • BE-41C / LP , BE-41IPIC / LP • 2105-900 Rev . P • 6/09 41 B. Assemble V ent Sections (SLP Pipe Only) T o attach the fi rst vent component to the starting collars of the appliance: • Attach a DVP-2SL or DVP-SLP24 adapter to the starting collar of the appliance. • Lock the vent components into place by sliding the pipe sec[...]

  • Page 42

    Heat & Glo • BE-41C / LP , BE-41IPIC / LP • 2105-900 Rev . P • 6/09 42 120º Figure 10.8 Securing V ertical Pipe Sections 120º Figure 10.9 Securing Horizontal Pipe Sections E. Disassemble V ent Sections • Rotate either section (see Figure 10.10) so the seams on both pipe sections are aligned as shown in Figure 10.1 1. • Pull carefull[...]

  • Page 43

    Heat & Glo • BE-41C / LP , BE-41IPIC / LP • 2105-900 Rev . P • 6/09 43 F . Install Decorative Ceiling Components (SLP only) A decorative ceiling thimble can be installed on a fl at ceil- ing through which the vent passes. The decorative ceiling thimble is used to cover the fi restop. • Seal the gap between the vent pipe and fi restop[...]

  • Page 44

    Heat & Glo • BE-41C / LP , BE-41IPIC / LP • 2105-900 Rev . P • 6/09 44 G. Install Metal Roof Flashing • See minimum vent heights for various pitched roofs (Figure 10.14) to determine the length of pipe to extend through the roof. • Slide the roof fl ashing over the pipe sections extending through the roof as shown in Figure 10.15. Ro[...]

  • Page 45

    Heat & Glo • BE-41C / LP , BE-41IPIC / LP • 2105-900 Rev . P • 6/09 45 SCREWS CAULK STORM COLLAR (1 of 3) Figure 10.18 Figure 10.18 TERMINA TION CAP I. Install V ertical T ermination Cap • Attach the vertical termination cap by sliding the inner collar of the cap into the inner fl ue of the pipe section while placing the outer collar o[...]

  • Page 46

    Heat & Glo • BE-41C / LP , BE-41IPIC / LP • 2105-900 Rev . P • 6/09 46 Figure 10.20 Venting through the wall INTERIOR HEA T SHIELD OR EXTENDED HEA T SHIELD W ALL SHIELD FIRESTOP HEA T SHIELD 1-1/2 IN. (38 MM) MIN. OVERLAP SHEA THING VENT DEPTH FROM BACK OF APPLIANCE T O OUTSIDE SURF ACE OF EXTERIOR W ALL (SEE CHART BELOW) SLIP SECTION CAN[...]

  • Page 47

    Heat & Glo • BE-41C / LP , BE-41IPIC / LP • 2105-900 Rev . P • 6/09 47 A. Fuel Conversion • Make sure the appliance is compatible with available gas types. • Conversions must be made by a qualified service technician using Hearth & Home T echnologies speci fi ed and approved parts. B. Gas Pressure • Optimum appliance performanc[...]

  • Page 48

    Heat & Glo • BE-41C / LP , BE-41IPIC / LP • 2105-900 Rev . P • 6/09 48 Figure 12.1 Ignitor Button C. Standing Pilot Ignition System Wiring • The standing pilot ignition system wiring does not require a 1 10 V AC supply to operate. See Figure 12.3 • A 1 10 V AC junction box MUST be installed for use with a fan or remote control. See Fi[...]

  • Page 49

    Heat & Glo • BE-41C / LP , BE-41IPIC / LP • 2105-900 Rev . P • 6/09 49 E. Electrical Service and Repair W ARNING! Risk of Shock! Label all wires prior to dis- connection when servicing controls. Wiring errors can cause improper and dangerous operation. V erify proper operation after servicing. Figure 12.2 IntelliFire Pilot Ignition (IPI) [...]

  • Page 50

    Heat & Glo • BE-41C / LP , BE-41IPIC / LP • 2105-900 Rev . P • 6/09 50 G. W all Switch Installation for Fan (Optional) If the box is being wired to a wall mounted switch for use with a fan (See Figure 12.5): • The power supply for the appliance must be brought into a switch box. • The power can then be supplied from the switch box to [...]

  • Page 51

    Heat & Glo • BE-41C / LP , BE-41IPIC / LP • 2105-900 Rev . P • 6/09 51 1 3 13 Fi nishing A. Mantel and W all Projections W ARNING! Risk of Fire! Comply with all minimum clear- ances as speci fi ed. Framing closer than the minimums list- ed must be constructed entirely of noncombustible materials (i.e., steel studs, concrete board, etc.).[...]

  • Page 52

    Heat & Glo • BE-41C / LP , BE-41IPIC / LP • 2105-900 Rev . P • 6/09 52 C. Doors Only doors certi fi ed for use with this appliance model may be used. Contact your dealer for a list of doors that may be used. Once you have determined what kind of door and fi nishing material is going to be used on the fi replace, you may use the table b[...]

  • Page 53

    Heat & Glo • BE-41C / LP , BE-41IPIC / LP • 2105-900 Rev . P • 6/09 53 A. Remove Fixed Glass Assembly See Section 14.G. B. Remove the Shipping Materials Remove shipping materials from inside or underneath the fi rebox. C. Clean the Appliance Clean/vacuum any sawdust that may have accumulated inside the fi rebox or underneath in the cont[...]

  • Page 54

    Heat & Glo • BE-41C / LP , BE-41IPIC / LP • 2105-900 Rev . P • 6/09 54 F . Install the Log Assembly LOG ASSEMBL Y : LOGS-6000BE 1. Release four glass clips and set the glass assembly aside. NOTE: See Step 9 when replacing the log set in an existing fi replace. 2. Carefully cut the cable tie holding the log assembly in place and discard t[...]

  • Page 55

    Heat & Glo • BE-41C / LP , BE-41IPIC / LP • 2105-900 Rev . P • 6/09 55 5. The grate is located in the lower cavity . Remove the screw holding the grate in place and discard the screw . 6. Position the grate into the cutout in the refractory . Hook the grate into position using the tabs on the bottom of the grate. Make sure the grate is pu[...]

  • Page 56

    Heat & Glo • BE-41C / LP , BE-41IPIC / LP • 2105-900 Rev . P • 6/09 56 Figure 14.2 Fixed Glass Assembly G. Fixed Glass Assembly W ARNING! Risk of Asphyxiation! Handle fi xed glass assembly with care. Inspect the gasket to ensure it is undamaged and inspect the glass for cracks, chips or scratches. • DO NOT strike, slam or scratch glass[...]

  • Page 57

    Heat & Glo • BE-41C / LP , BE-41IPIC / LP • 2105-900 Rev . P • 6/09 57 A. Standing Pilot Ignition System 1 5 15 T roubleshooting With proper installation, operation, and maintenance your gas appliance will provide years of trouble-free service. If you do experience a problem, this troubleshooting guide will assist a quali fi ed service t[...]

  • Page 58

    Heat & Glo • BE-41C / LP , BE-41IPIC / LP • 2105-900 Rev . P • 6/09 58 T roubleshooting (continued) Symptom Possible Cause Corrective Action 3. (Continued) C. V alve. T urn the valve knob to the ON position. Place the ON/ OFF switch in the ON position. T ake a reading with a millivolt meter at the thermopile terminals. The millivolt meter[...]

  • Page 59

    Heat & Glo • BE-41C / LP , BE-41IPIC / LP • 2105-900 Rev . P • 6/09 59 B. IntelliFire Ignition System Symptom Possible Cause Corrective Action 1. Pilot won’t light. The ignitor/module makes noise, but no spark. A. Incorrect wiring. V erify “S” wire (white) for sensor and “I” wire (orange) for ignitor are connected to correct ter[...]

  • Page 60

    Heat & Glo • BE-41C / LP , BE-41IPIC / LP • 2105-900 Rev . P • 6/09 60 IntelliFire Ignition System - (continued) Symptom Possible Cause Corrective Action 4. Pilot lights but contin- ues to spark, and main burner will not ignite. (If the pilot continues to spark after the pilot fl ame has been lit, fl ame recti fi cation has not occurre[...]

  • Page 61

    Heat & Glo • BE-41C / LP , BE-41IPIC / LP • 2105-900 Rev . P • 6/09 61 1 6 16 Reference Materials A. Appliance Dimension Diagram Dimensions are actual appliance dimensions. Use for reference only . For framing dimensions and clearances refer to Section 5. Figure 16.1 Appliance Dimensions A D B C H ELECTRICAL ACC ESS G F E GAS LINE ACC ESS[...]

  • Page 62

    Heat & Glo • BE-41C / LP , BE-41IPIC / LP • 2105-900 Rev . P • 6/09 62 B. V ent Components Diagrams Figure 16.2 DVP vent components 10-1/2 in. (267 mm) 10-7/8 in. (276 mm) 45 ° 7-3/8 in. (187 mm) 11-3/8 in. (289 mm) 1-1/4 in. (32 mm) 9-1/4 in. (235 mm) 13-1/4 in. (337 mm) 1/2 in. TYP DVP90ST (90° Elbow) 10 in. (254 mm) 10 in. (254 mm) 1[...]

  • Page 63

    Heat & Glo • BE-41C / LP , BE-41IPIC / LP • 2105-900 Rev . P • 6/09 63 DVP-HPC1 DVP-HPC2 DVP-TRAP1 DVP-TRAP2 DVP-TRAPK2 DVP-TRAPK1 DVP-TRAP Horizontal T ermination Cap 15-1/8 in. (384 mm) 12 in. (305 mm) 8 in. (203 mm) Max Effective Length Note: Heat shields MUST overlap by a minimum of 1-1/2 in. (38 mm). The heat shield is designed to be[...]

  • Page 64

    Heat & Glo • BE-41C / LP , BE-41IPIC / LP • 2105-900 Rev . P • 6/09 64 13-1/4 in. (367 mm) 24-5/8 in. (625 mm) 27-1/2 in. (127 mm) RF6M Roof Flashing Multi-pak 31 in. (787 mm) 24-5/8 in. (625 mm) 13-1/4 in. (367 mm) RF12M Roof Flashing Multi-pak BEK Trap Ca p Brick Extension 13-3/4 in. (349 mm) 5 in. (127 mm) 13-3/4 in. (349 mm) Cap Shiel[...]

  • Page 65

    Heat & Glo • BE-41C / LP , BE-41IPIC / LP • 2105-900 Rev . P • 6/09 65 DVP-TB1 BasementVent Cap 12 in. (305 mm) 1-1/2 in. (38 mm) 7-3/8 in. (187 mm) 14 in. (356 mm) 17-3/4 in. (451 mm) 7-1/4 in. 12 in. 305 mm (184 mm) 5-1/4 in. (133 mm) 12-1/2 in. (318 mm) DVP-TVHW VerticalTermination Cap (Highwind) PVK-80 (For use with IPI and DSI applia[...]

  • Page 66

    Heat & Glo • BE-41C / LP , BE-41IPIC / LP • 2105-900 Rev . P • 6/09 66 B. V ent Components Diagrams (continued) DVP-HRC-SS DVP-HRC-ZC-SS HORIZONT AL TERMINA TION CAP 13 in. (330 mm) 15 in. (381 mm) 8-1/8 in. (206 mm) 10-7/8 in. 276 mm 10-1/2 in. 267 mm 3° 87° Effective Length 5-3/4 to 8-3/8 in. 146 to 213 mm 5-1/2 in. 140 mm 8-3/8 in. 2[...]

  • Page 67

    Heat & Glo • BE-41C / LP , BE-41IPIC / LP • 2105-900 Rev . P • 6/09 67 B. V ent Components Diagrams (continued) Figure 16.7 SLP Series V ent Components Effective Height/Length Pipe inches mm SLP4 4 102 SLP6 6 152 SLP12 12 305 SLP24 24 610 SLP36 36 914 SLP48 48 1219 SLP6A 2 - 6 51 - 152 SLP12A 2 - 12 51 - 305 8-3/4 in. 222 mm 6-1/2 in. 165[...]

  • Page 68

    Heat & Glo • BE-41C / LP , BE-41IPIC / LP • 2105-900 Rev . P • 6/09 68 B. V ent Components Diagrams (continued) Figure 16.8 SLP Series V ent Components SLP-SNKD Snorkel T ermination Cap SLP-TVHW Ve r t i c a l T ermination Cap SLP-CCS-BK Cathedral Ceiling Support Box-Black SLP-DCF-BK Ceiling Firestop Black SLP-WT - BK W all Thimble-Black [...]

  • Page 69

    Heat & Glo • BE-41C / LP , BE-41IPIC / LP • 2105-900 Rev . P • 6/09 73 Heat & Glo, a brand of Hearth & Home T echnologies Inc. 7571 215 th Street West, Lakeville, MN 55044 www .heatnglo.com D. Contact Information Please contact your Heat & Glo dealer with any questions or concerns. For the location of your nearest Heat & G[...]