Go to page of
Similar user manuals
-
Water Pump
Hitachi 232437
20 pages 0.44 mb -
Water Pump
Hitachi 222104
16 pages 0.2 mb -
Water Pump
Hitachi 312350E
24 pages 1.37 mb -
Water Pump
Hitachi 308996J
26 pages 0.4 mb -
Water Pump
Hitachi 236464
28 pages 0.42 mb -
Water Pump
Hitachi 1800
28 pages 1.4 mb -
Water Pump
Hitachi FD2 1590
50 pages 2.72 mb -
Water Pump
Hitachi 210313
16 pages 0.21 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Hitachi 210313, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Hitachi 210313 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Hitachi 210313. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Hitachi 210313 should contain:
- informations concerning technical data of Hitachi 210313
- name of the manufacturer and a year of construction of the Hitachi 210313 item
- rules of operation, control and maintenance of the Hitachi 210313 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Hitachi 210313 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Hitachi 210313, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Hitachi service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Hitachi 210313.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Hitachi 210313 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
Instructions – Parts List GRACO INC.ąP .O. BOX 1441ąMINNEAPOLIS, MNą55440-1441 Copyright 1975, Graco Inc. is registered to I.S. EN ISO 9001 307160R Read warnings and instructions. V iscount R II Pump 1500 psi (10.3 MPa, 103 bar) Maximum Hydraulic Input Pressure 1000 psi (7 MPa, 69 bar) Maximum Pump Outlet Pressure Model 210313, Series D With S[...]
-
Page 2
2 307160 T able of Contents W arnings 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Installation 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Operation 8 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Maintenance 10 . . . . . . . . . . . . . . . . . . . . . . [...]
-
Page 3
3 307160 W ARNING INJECTION HAZARD Spray from the gun/valve, leaks or ruptured components can inject fluid into your body and cause ex- tremely serious injury , including the need for amputation. Fluid splashed in the eyes or on the skin can also cause serious injury . D Fluid injected into the skin might look like just a cut, but it is a serious i[...]
-
Page 4
4 307160 W ARNING FIRE AND EXPLOSION HAZARD Improper grounding, poor ventilation, open flames or sparks can cause a hazardous condition and re- sult in a fire or explosion and serious injury . D Ground the equipment and the object being sprayed. Refer to Grounding on page 5. D If there is any static sparking or you feel an electric shock while usin[...]
-
Page 5
5 307160 Installation General Information NOTE: Reference numbers and letters in parentheses in the text refer to the callouts in the figures and the parts drawing. NOTE: Always use Genuine Graco Parts and Acces- sories, available from your Graco distributor . Grounding W ARNING FIRE AND EXPLOSION HAZARD Before operating the pump, ground the system[...]
-
Page 6
6 307160 Installation Mount the pump to suit the type of installation planned. Pump dimensions and mounting hole layout are shown on page 14. CAUTION The hydraulic supply system must be kept clean at all times to avoid damage to the motor and hydraulic power supply . Blow out all hydraulic lines with air and flush thoroughly with compatible solvent[...]
-
Page 7
7 307160 Installation 0627A KEY A B C D E F G H J K L M N P Q R S T Fluid Hose to Gun Fluid Drain V alve Suction Hose Hydraulic Return Line Hydraulic Return Shutoff V alve Pressure Gauge Flow Control V alve Pressure Reducing V alve Accumulator Drain Line (from pressure reducing valve) Hydraulic Supply Line Hydraulic Power Supply Ground Wire W et-Cu[...]
-
Page 8
8 307160 Operation Pressure Relief Procedure W ARNING INJECTION HAZARD Fluid under high pressure can be in- jected through the skin and cause seri- ous injury . T o reduce the risk of an injury from injection, splashing fluid, or moving parts, fol- low the Pressure Relief Procedure whenever you D Are instructed to relieve the pressure D Stop sprayi[...]
-
Page 9
9 307160 Operation W ARNING COMPONENT RUPTURE HAZARD T o reduce the risk of overpressurizing your system, which could cause compo- nent rupture and serious injury , never exceed the specified Maximum Hydraulic Input Pressure to the pump (see the T echnical Data on page 15). T o prevent overpressurizing the hydraulic motor or its seals, always shut [...]
-
Page 10
10 307160 Maintenance Carefully monitor your fluid supply . If your pump us running too fast, or accelerates quickly , it is probably out of fluid. Shut off the hydraulic power supply imme- diately to prevent damage to the pump. If the fluid supply is empty , and air has entered the fluid lines, be sure to prime the pump again before regular operat[...]
-
Page 11
11 307160 T roubleshooting W ARNING T o reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 8. Before servicing this equipment, always make sure to relieve the pressure. NOTE: Check all possible problems and solutions before disassembling the pump. Problem Cause Solu[...]
-
Page 12
12 307160 Service Fig. 3 06640 1 11 8 7 1 1 12 3 6 5 T 4 9 1 T orque to 40–50 ft-lb (54–68 N S m) NOTE: T o service the displacement pump, refer to manual 308043, supplied. NOTE: T o service the hydraulic motor , refer to manual 308158, supplied. Disassembly (See Fig. 3) W ARNING T o reduce the risk of serious injury whenever you are instructed[...]
-
Page 13
13 307160 Parts 06640 11 8 7 1 1 12 3 6 5 4 9 Ref. No. Part N o. Description Qty . 1 100103 PIN, cott er; 1.5” (38.1 mm) long 2 3 101712 LOCKNUT ; 5/8–1 1; with nylon insert 3 4 101936 NUT , hex, jam; 3/4–10 1 5 158674 O-RING; nitrile rubber 1 6 16791 1 ROD, tie; 7” (177.8 mm) long, shoulder-to-shoulder 3 7 168210 NUT , shouldered 1 8 16821[...]
-
Page 14
14 307160 Dimensions 06641 48.1” (1220 mm) 23.2” (585 mm) 3/4 npt inlet 1” npt outlet 2” npt fluid inlet 1–1/2” npt fluid outlet Mounting Hole Layout 06595 gasket 161806 four 0.437” (1 1.1 mm) holes on 10.5” (267 mm) bolt circle 45 _ 90 _ 1.38” (34.9 mm) radius 4” (102 mm) 9.75” (247.7 mm) diameter[...]
-
Page 15
15 307160 T echnical Data Maximum hydraulic input pressure 1500 psi (10.3 MPa, 103 bar) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Maximum pump outlet pressure 1000 psi (7.0 MPa, 69 bar) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Hydraulic fluid cons[...]
-
Page 16
16 307160 Graco Standard W arranty Graco warrants all equipment manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale by a n authorized Graco distributor to the original purchaser for use. With the exception of any special, extended, or limited warranty published by Graco, Graco will, for[...]